Search NASA⌕ Search

SEARCH · Search NASA

Results for “stroke”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

Evaluation of the pulse-contour method of determining stroke volume in man.

The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.

Alderman, E. L.↗

Electric field intensity of the lightning return stroke.

From an examination of about 1000 electric field wave forms produced by lightning return strokes in 16 storms at distances between 20 and 100 km from an observation site at the Kennedy Space Center, Florida, a typical return stroke current wave form is derived. For this current wave form, the electric field intensity at distances between 0.5 and 100 km is computed for three values of return stroke velocity. The resultant curves for close lightning are compared with measured field wave forms. The transmission line return stroke model is used in all calculations since, as discussed, the Bruce-Golde model cannot account for the observed electric field characteristics.

Uman, M. A.↗

Tortuosity of lightning return stroke channels

Data obtained from photographs of lightning are presented on the tortuosity of return stroke channels. The data were obtained by making piecewise linear fits to the channels, and recording the cartesian coordinates of the ends of each linear segment. The mean change between ends of the segments was nearly zero in the horizontal direction and was about eight meters in the vertical direction. Histograms of these changes are presented. These data were used to create model lightning channels and to predict the electric fields radiated during return strokes. This was done using a computer generated random walk in which linear segments were placed end-to-end to form a piecewise linear representation of the channel. The computer selected random numbers for the ends of the segments assuming a normal distribution with the measured statistics. Once the channels were simulated, the electric fields radiated during a return stroke were predicted using a transmission line model on each segment. It was found that realistic channels are obtained with this procedure, but only if the model includes two scales of tortuosity: fine scale irregularities corresponding to the local channel tortuosity which are superimposed on large scale horizontal drifts. The two scales of tortuosity are also necessary to obtain agreement between the electric fields computed mathematically from the simulated channels and the electric fields radiated from real return strokes. Without large scale drifts, the computed electric fields do not have the undulations characteristics of the data.

Levine, D. M.↗

Three unusual strokes in a triggered lightning flash

Time-resolved photographic records of three strokes of a triggered lightning flash are examined. These strokes exhibit several examples of novel behavior that include (1) the abrupt transformation of dart leaders to stepped leaders and (2) the partial 'reflection' of dart leader luminosity back up the channel. Both phenomena are associated with an apparent discontinuity in channel characteristics between the natural and artificial (wire) sections of the channel. We estimate the ratio of characteristic impedances for these sections to have an upper bound of about a factor of 3. Analysis of one of the dart leader 'reflections' yields a propagation speed of 9.6 x 10 to the 7th m/s whereas the dart leader and return stroke speeds (two-dimensional) over the same channel section are 1.7 x 10 to the 7th and 13 x 10 to the seventh m/s, respectively. Also, one of the return strokes reveals the occurrence of two distinct waves of luminosity that are separated by only 5 microns and that travel up nearly identical channels that differ only in the channel terminus.

Idone, V. P.↗

Plotting Lightning-Stroke Data

Data on lightning-stroke locations become easier to correlate with cloudcover maps with aid of new graphical treatment. Geographic region divided by grid into array of cells. Number of lightning strokes in each cell tabulated, and value representing density of lightning strokes assigned to each cell. With contour-plotting routine, computer draws contours of lightning-stroke density for region. Shapes of contours compared directly with shapes of storm cells.

Tatom, F. B.↗

Characteristics of return stroke electric fields produced by lightning flashes at distances of 1 to 15 kilometers

Electric field derivative signals from single and multiple lightning strokes are presented. For about 25 pct. of all acquired waveforms, produced by return strokes, stepped leaders or intracloud discharges, type and distance of the signal source are known from the observations by an all sky video camera system. The analysis of the electric field derivative waveforms in the time domain shows a significant difference in the impulse width between return stroke signals and those of stepped leaders and intracloud discharges. In addition, the computed amplitude density spectrum of return stroke waveforms lies by a factor of 10 above that of stepped leaders and intracloud discharges in the frequency range from 50 to 500 kHz.

Hopf, CH.↗

Effect of surface conductivity on the peak magnetic field radiated by first return strokes in cloud-to-ground lightning

The effect of surface conductivity on the peak magnetic field radiated by the first return stroke in cloud-to-ground lightning was investigated by comparing the peak magnetic fields from return strokes that struck water with those that struck land. The data were obtained from a network of three gated, wideband magnetic direction finders (DFs) at the NASA Kennedy Space Center during the summer of 1985. Two geographical areas that were equidistant from two of the direction finders were compared where the flash distances ranged from approximately 40 to 60 km. An unbiased data set was obtained by correcting site errors, equalizing differences in sensor gain, eliminating directional biases in DF triggering, and keeping differences in signal attenuation over the two surfaces to a minimum. When a statistical analysis was performed on the frequency distributions of the signal amplitudes, there was no statistically significant difference in the peak amplitudes of first return strokes over land (lambda = 8.2 x 10(exp -3) mho/m) and over water (lambda = 4 mho/m). Therefore we infer that the conductivity of the underlying surface does not significantly affect the magnitude of the peak magnetic field, and hence the peak current, in the first return stroke of a cloud-to-ground lightning flash.

Tyahla, Lori J.↗

A Method to Estimate the Probability That Any Individual Cloud-to-Ground Lightning Stroke Was Within Any Radius of Any Point

A new technique has been developed to estimate the probability that a nearby cloud-to-ground lightning stroke was within a specified radius of any point of interest. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even within the location error ellipse. This technique is adapted from a method of calculating the probability of debris collision with spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force station.

Huddleston, Lisa L.↗

A Method to Estimate the Probability that Any Individual Cloud-to-Ground Lightning Stroke was Within Any Radius of Any Point

A new technique has been developed to estimate the probability that a nearby cloud-to-ground lightning stroke was within a specified radius of any point of interest. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even within the location error ellipse. This technique is adapted from a method of calculating the probability of debris collision with spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force station. Future applications could include forensic meteorology.

Huddleston, Lisa↗

A Method to Estimate the Probability that any Individual Cloud-to-Ground Lightning Stroke was Within any Radius of any Point

A new technique has been developed to estimate the probability that a nearby cloud to ground lightning stroke was within a specified radius of any point of interest. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even with the location error ellipse. This technique is adapted from a method of calculating the probability of debris collision with spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force Station. Future applications could include forensic meteorology.

Huddleston, Lisa L.↗

Highly efficient 6-stroke engine cycle with water injection

A six-stroke engine cycle having improved efficiency. Heat is recovered from the engine combustion gases by using a 6-stroke engine cycle in which combustion gases are partially vented proximate the bottom-dead-center position of the fourth stroke cycle, and water is injected proximate the top-dead-center position of the fourth stroke cycle.

42 ENGINEERING↗

Causal control design for wave energy converters with finite stroke

Control design is of central importance in the optimization of power generation from ocean wave energy converters (WECs). The problem is made challenging by the fact that the resource is vibratory and stochastic, with a low quality factor. It has recently been shown that when constrained to causality, the optimal feedback controller for a WEC is solvable in closed-form as a sign-indefinite LQG problem, for the case in which the WEC exhibits linear dynamics and quadratic power transmission dissipation. However, most WECs exhibit stroke limits, which must be explicitly accounted for in control design to avoid end-stop collisions. This is important because such collisions lead to damage, and also because the introduction of unmodeled stroke limits can actually destabilize the otherwise-optimal closed loop. We illustrate a control design technique to address this issue, which consists of two design steps. In the first step, LMI techniques are used to optimize the mean power harvested from waves with a known power spectral density, subject to several competing objectives. In the second step, the controller is augmented via a nonlinear passivity-based outer-loop design which guarantees to prevent stroke saturation while also guaranteeing to preserve closed-loop stability. Furthermore, the technique is illustrated using a model of a simple heaving point absorber, and verified in simulation.

16 TIDAL AND WAVE POWER↗

A Surgeon's View on Endarterectomy and Stenting in 2011: Lest We Forget, It's All About Preventing Stroke

It has been nearly 60 years since Felix Eastcott published his seminal paper on carotid reconstruction, which paved the way for carotid endarterectomy (CEA) and then carotid artery stenting (CAS) to assume prominent roles in the prevention of stroke. Yet the ensuing 60 years has witnessed repeated cycles of challenges to practice, professional mistrust, conflicts of interest, dogmatic retention of traditional management strategies, inappropriate corporate interventions, and a general failure to adapt to new evidence. Even the performance of large-scale randomised trials has been associated with rancour and a lack of consensus. This article reviews the history of invasive interventions in the treatment of carotid disease and makes a plea to both the surgical and interventional communities that the fundamental priority must always be the prevention of stroke. It concludes with an appeal for colleagues to collaborate to determine how best to treat patients during the hyperacute period after the onset of symptoms and to identify a smaller cohort of asymptomatic patients who are truly at high risk for stroke in whom to target CAS or CEA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spontaneous Solitaire™ AB Thrombectomy Stent Detachment During Stroke Treatment

Spontaneous Solitaire™ stent retriever detachment is a rarely defined entity seen during stroke treatment, which can result in a disastrous clinical outcome if it cannot be solved within a critical stroke treatment time window. Two solutions to this problem are presented in the literature. The first is to leave the stent in place and apply angioplasty to the detached stent, while the second involves surgically removing the stent from the location at which it detached. Here, we present a case of inadvertent stent detachment during stroke treatment for a middle cerebral artery M1 occlusion resulting in progressive thrombosis. The detached stent was removed endovascularly by another Solitaire stent, resulting in the recanalization of the occluded middle cerebral artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Stroke Therapy with a Novel 6-French Aspiration Catheter

Background and Purpose: Direct thrombus aspiration is increasingly used as a first-line therapy in acute ischemic stroke with large vessel occlusion. We assessed the performance and safety of a novel aspiration catheter available: the 6-French AXS Catalyst catheter. Materials and Methods: We conducted a cohort study from a prospective clinical registry of consecutive stroke patients treated by mechanical thrombectomy between March 2016 and July 2016. Baseline clinical and imaging characteristics, recanalization rates, complications, and clinical outcomes were analyzed. Results: Among the 60 patients included, 30 were treated using aspiration alone, 14 were treated using aspiration and then stent retriever as a rescue therapy, and 16 were treated using aspiration combined with a stent retriever straightaway. Successful recanalization (mTICI2b/3) was achieved in 85% patients and functional independence in 48.3%. We observed one intracranial perforation and one vertebral artery dissection. Symptomatic intracranial hemorrhage occurred in 5% and mortality in 21.7%. Conclusion: Endovascular stroke therapy using the AXS Catalyst catheter seems safe and effective, with similar performance than other reperfusion catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long non-coding RNA RMST silencing protects against middle cerebral artery occlusion (MCAO)-induced ischemic stroke

Highlights: • RMST expression is significantly up-regulated ischemic brain. • RMST silencing protects hippocampal neurons against OGD-induced stress. • RMST silencing protects against ischemic brain injury in vivo. • RMST silencing improves neurological function. Long non-coding RNAs (lncRNAs) have emerged as major regulators in neurological diseases, and clarifying their roles in cerebral ischemic injury may provide novel targets for treating ischemic stroke. In this study, we mainly studied the role of lncRNA-RMST in middle cerebral artery occlusion (MCAO)-induced mouse brain injury. We showed that RMST expression level was significantly up-regulated in oxygen-glucose deprivation (OGD)-treated primary hippocampal neuron, MCAO-induced injured brain, and the plasma of patients with ischemic stroke. RMST silencing protected against MCAO-induced ischemic brain injury in vivo and OGD-induced primary hippocampal neuron injury in vitro. Intracerebroventricular injection of RMST shRNA significantly decreased brain RMST expression, reduced brain infarct size, and improved neurological function. Collectively, this study provides evidence that lncRNA is involved in the pathogenesis of ischemic brain injury, and suggests a promising approach of RMST inhibition in treating ischemic stroke.

60 APPLIED LIFE SCIENCES↗

An optimization method for flexural bearing design for high-stroke high-frequency applications

A method for optimization of a high-stroke, high-frequency flexural bearing was completed. The main goal was to design a flexural bearing system as the energy restoration component of a one kW free piston linear engine alternator (LEA) operating at 90 Hz and maximum targeted displacement of 22 mm. Defined electricity output of 1 kW, with more than 30% efficiency, required engine operation under high speed and high stroke conditions. Under such challenging stroke and frequency requirements, a method of design was required to select between a wide range of parameters in flexural bearing design. A parametric CAD model was prepared and used in the optimization package of a finite element analysis (FEA) software. Four main parameters of flexural bearing geometry were identified and included the outer diameter, thickness, number of arms, and sweep angle of spiral cuts. Other design parameters including spiral gap width, shape factor and spiral start points angle were shown to be less important compared to these four main parameters in primary design and were examined separately. A neural network algorithm was used to investigate the interactions and effects of design parameters. The sensitivity of each parameter on output criteria such as maximum stress and natural frequency was examined and design charts developed. Methods for further modification of the spiral curve at end points were introduced to reduce the maximum stress level by up to 20%. Several steel alloys and a titanium-based alloy were identified as proper material candidates for high cycle applications and the final designed spring was manufactured and tested to validate the FEA results of axial stiffness and strain level throughout the flexure arms. The percent of the flexure’s moving mass was estimated to be 29% with FEA analysis and compared well with the experimental value of 31%. The stress/strain results of the FEA analysis matched with the experimental results – within ±5%.

42 ENGINEERING↗