Search NASA⌕ Search

SEARCH · Search NASA

Results for “sub-micron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effect of micron-scale manufacturing flaws on the tensile response of centimeter sized two-photon polymerization microlattices

Two-photon polymerization (TPP) is a unique fabrication technique that enables sub-micron scale resolution. Herein, we report on uniaxial tensile tests on millimeter-sized TPP log-pile structures that were fabricated using a recently developed interdigitated stitching strategy. As expected, the Young’s modulus increased with laser intensity, however elastic modulus, ultimate strength and strain-at-failure varied widely, even for nominally identical samples. Post-mortem analysis revealed a series of print defects resulting from various sources including misalignments, resin shrinkage, laser beam shadowing, and local depletion of the oxygen inhibitor. While some of the defects can be eliminated, such as misalignments due to insufficient precision of the mechanical stage, others are more intrinsic to TPP and thus more difficult to address.

36 MATERIALS SCIENCE↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

RESONANT MATCHING SECTION FOR CEBAF ENERGY UPGRADE

In order to prevent emittance growth during long stores of the proton beam at the future Electron-Ion Collider (EIC), we need to have some mechanism to provide fast cooling of the dense proton beams. One promising method is coherent electron cooling (CeC), which uses an electron beam to both ?measure? the positions of protons within the bunch and then apply energy kicks which tend to reduce their longitudinal and transverse actions. In this work, we discuss the under- lying physics of this process. We then discuss simulations which constrain the electrons to move only longitudinally in order to perform fast optimizations and long-term track- ing of the bunch evolution, and benchmark these results against fully 3D codes. Additionally, we discuss practical challenges, including the necessity of a high-quality elec- tron beam and sub-micron alignment of the electrons and protons.

Deitrick, K.↗

Storage and Diffusion of Carbon and Nitrogen in Crustal Materials

Nitrogen is a primary constituent of Earth’s atmosphere and an essential component of many biological processes. Recent developments in understanding N incorporation into silicate minerals suggest that the solid earth and lithosphere could provide a substantial reservoir for the planetary N budget. Furthermore, determining the concentration and distribution of low abundances of N in silicates presents a significant challenge in microanalysis. We tested capabilities for high spatial resolution quantification of low levels of N using EPMA with the goal of developing standards to be used in coupled N and noble gas analyses of silicate minerals. We investigated the concentration and distribution of N in a suite of ammonium-bearing silicate minerals that reflect the dominant N-bearing phases of the lithosphere: tobelite, buddingtonite, ammonioleucite, tsaregorodtsevite, and hyalophane. These minerals form during NH 4 -rich alteration of K-bearing silicate minerals, and the bonding environment of N in each mineral is likely to differ based on crystal structure. Using an optimized analytical routine for N quantification enables sensitivity approaching 0.02 weight% N and high-resolution quantitative mapping of sub-micron variations in N contents.

58 GEOSCIENCES↗

Fundamentals of Spark-Plasma Sintering (Final Report)

This project was focused on the development of the general theory of spark-plasma sintering (SPS) taking into account the role of both thermal and non-thermal factors in the acceleration of SPS mass transport. SPS is a particular kind of field-assisted sintering, which provides potentially revolutionary capabilities to the processing of materials into configurations previously unattainable. This approach significantly improves the processing time- and quality-wise. It carries the potential of maintaining the nano and sub-micron structure in nano-powder-based materials after consolidation. SPS gains particular prominence in connection with its exceptional potential of rapid and ultra-rapid processing of very hard-to-deform materials, which would typically require lengthy consolidation times at significantly elevated temperatures under conditions of conventional powder pressing or sintering. The achievement of the ultimate goal of the formulation of the general theory of spark plasma sintering required the identification of the contributions of all the thermal and non-thermal factors in the enhancement of mass transport under SPS processing conditions. As our research indicated, this enhancement is mostly reduced to the creation of the conditions of controlled non-equilibrium, which is especially important in ultra-rapid field-assisted sintering techniques. Thus, the main project objective was the analysis of the SPS physical basis at multiple scales specifically exploring the role of electric current in the acceleration of mass transport and with an emphasis on the conditions of controlled non-equilibrium.

36 MATERIALS SCIENCE↗

Solid Phase Processing of Lead-Free Brass with Carbon Additives

Currently, “lead-free” brass alloys (like C27450/C27451/C6930), used extensively in drinking water fixtures and automotive, electrical, and electronic applications contain maximum 0.25% lead to maintain mechanical performance and machinability. Adding graphite to brass as an alternative to lead, using casting, powder metallurgy, and extrusion methods, has been explored previously. However, all these methods have proven to be energy-, time-, and resource-intensive, while not enabling performance equivalent to that of C36000 brass. In this project, we developed a one-step approach using friction extrusion and ShAPE to make lead-free brass/graphite components such as wires, rods and tubes with mechanical performance equivalent to commercial lead-free brass alloys. Manufacturing temperatures were maintained ~550-730 °C with feed rates ranging between 4 – 25 mm/min. Results show larger grains at the center of the rods and wires with smaller grains developing at the edges. Graphite particles were sheared in the direction of extrusion with higher strains observed towards the edges. Hardness of the brass/graphite samples was over 25% higher than that of the corresponding brass-only samples (rods and wires), also friction extruded. Our results show that the sub-micron graphite plays an important role in limiting process temperature and restraining grain growth during friction extrusion, thus reducing grain size in composites.

36 MATERIALS SCIENCE↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of carbonaceous aerosols during TRACER-CAT

Absorbing aerosols (AA) have an important impact on the global radiation budget and cloud properties. The composition and properties of AA can vary substantially throughout the atmosphere, depending on the particle source and the influence of chemical aging. Uncertainties associated with the radiative effects of AA remain substantial. A key contributor to this uncertainty is understanding the extent to which coatings in general, and water uptake especially, alters absorption by AA particles and how this depends on particle composition. We deployed new and existing experimental tools during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, TX as part of the Carbonaceous Aerosols Thrust (CAT) to provide detailed characterization of aerosol optical, chemical, and physical properties. Our TRACER-CAT measurements complemented and expanded on the planned TRACER instrumentation, allowing for more detailed characterization of aerosol properties of relevance to cloud development (a core focus of TRACER), such as the composition of particles that can act as cloud condensation nuclei, than would otherwise be available. Our measurements have allowed for assessment of the relationship(s) between AA optical properties (with a focus on absorption) and the chemical and physical characteristics (including the mixing state of black carbon (BC) containing particles). These field observations occurred in collaboration with Los Alamos National Laboratory in summer 2022 during the TRACER intensive operating period. The instrumentation we co-deployed provided for measurement of (i) multi-wavelength dry aerosol absorption, scattering, and extinction, (ii) the size-dependent composition and abundance of sub-micron aerosol, differentiating between those particles that do and do not contain BC, (iii) BC-specific concentrations and size distributions, (iv) particle size, and (v) the first field measurements at an ARM site of the influence of RH on multi-wavelength absorption by ambient AA. We have leveraged the natural variability of the atmosphere and of aerosol sources in the Houston region to (i) specifically disentangle contributions to light absorption from BC, absorbing organic carbon (brown carbon), and coatings on BC, (ii) characterize the mixing state of BC and assess the factors that give rise to compositional differences between BC-containing and BC-free aerosol, and (iii) establish how water uptake influences absorption and how any such effect depends on particle composition and BC mixing state. Overall, our study contributed to the mission of the Atmospheric System Research program in multiple ways. Through the deployment of complementary, advanced instrumentation for characterization of a wide range of aerosol properties our work helped to maximize the scientific impact of the TRACER campaign. Our work also allowed for development of new insights into the relationship(s) between aerosol composition, hygroscopicity, and the mixing state of BC with aerosol optical properties. Through this, our work has provided knowledge that can improve understanding and model representation of aerosol processes as they affect the Earth’s radiation budget.

54 ENVIRONMENTAL SCIENCES↗

Detection and Aggregation of Listeria Monocytogenes Using Polyclonal Antibody Gold-Coated Magnetic Nanoshells Surface-Enhanced Raman Spectroscopy Substrates

Magnetic nanoshells with tailored surface chemistry can enhance bacterial detection and separation technologies. This work demonstrated a simple technique to detect, capture, and aggregate bacteria with the aid of end-functionalized polyclonal antibody gold-coated magnetic nanoshells (pAb-Lis-AuMNs) as surface-enhanced Raman spectroscopy (SERS) probes. Listeria monocytogenes were used as the pathogenic bacteria and the pAb-LisAuMNs, 300 nm diameter, were used as probes allowing facile magnetic separation and aggregation. An optimized covalent bioconjugation procedure between the magnetic nanoshells and the polyclonal antibody was performed at pH six via a carbodiimide crosslinking reaction. Spectroscopic and morphological characterization techniques confirmed the fabrication of stable pAb-Lis-AuMNs. The resulting pAb-Lis-AuMNs acted as a SERS probe for L. monocytogenes based on the targeted capture via surface binding interactions and magnetically induced aggregation. Label-free SERS measurements were recorded for the minimum detectable amount of L. monocytogenes based on the SERS intensity at the 1388 cm -1 Raman shift. L. monocytogenes concentrations exhibited detection limits in the range of 10 4 –10 7 CFU ml -1 , before and after aggregation. By fitting these concentrations, the limit of detection of this method was ~10 3 CFU ml -1 . Using a low-intensity magnetic field of 35 G, pAb-LisAuMNs aggregated L. monocytogenes as demonstrated with microscopy techniques, including SEM and optical microscopy. Overall, this work presents a label-free SERS probe method comprised of a surface-modified polyclonal antibody sub-micron magnetic nanoshell structures with high sensitivity and magnetic induced separation that could lead to the fabrication of multiple single-step sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effects of Focused Ion Beam Lithography on La 2– x Sr x CuO 4 Single Crystals

Focused ion beam (FIB) milling is a mask-free lithography technique that allows the precise shaping of 3D materials on the micron and sub-micron scale. The recent discovery of electronic nematicity in La 2–x Sr x CuO 4 (LSCO) thin films triggered the search for the same phenomenon in bulk LSCO crystals. With this motivation, we have systematically explored FIB patterning of bulk LSCO crystals into micro-devices suitable for longitudinal and transverse resistivity measurements. We found that several detrimental factors can affect the result, ultimately compromising the possibility of effectively using FIB milling to fabricate sub-micrometer LSCO devices, especially in the underdoped regime.

36 MATERIALS SCIENCE↗

Advances in 3D Gel Printing for Enzyme Immobilization

Incorporating enzymes with three-dimensional (3D) printing is an exciting new field of convergence research that holds infinite potential for creating highly customizable components with diverse and efficient biocatalytic properties. Enzymes, nature’s nanoscale protein-based catalysts, perform crucial functions in biological systems and play increasingly important roles in modern chemical processing methods, cascade reactions, and sensor technologies. Immobilizing enzymes on solid carriers facilitates their recovery and reuse, improves stability and longevity, broadens applicability, and reduces overall processing and chemical conversion costs. Three-dimensional printing offers extraordinary flexibility for creating high-resolution complex structures that enable completely new reactor designs with versatile sub-micron functional features in macroscale objects. Immobilizing enzymes on or in 3D printed structures makes it possible to precisely control their spatial location for the optimal catalytic reaction. Combining the rapid advances in these two technologies is leading to completely new levels of control and precision in fabricating immobilized enzyme catalysts. The goal of this review is to promote further research by providing a critical discussion of 3D printed enzyme immobilization methods encompassing both post-printing immobilization and immobilization by physical entrapment during 3D printing. Especially, 3D printed gel matrix techniques offer mild single-step entrapment mechanisms that produce ideal environments for enzymes with high retention of catalytic function and unparalleled fabrication control. Examples from the literature, comparisons of the benefits and challenges of different combinations of the two technologies, novel approaches employed to enhance printed hydrogel physical properties, and an outlook on future directions are included to provide inspiration and insights for pursuing work in this promising field.

3D printing↗

Efficiency Studies of Fast Neutron Tracking Using MCNP

Fast neutron identification and spectroscopy is of great interest to nuclear physics experiments. Using the neutron elastic scattering, the fast neutron momentum can be measured. Wang and Morris introduced the theoretical concept that the initial fast neutron momentum can be derived from up to three consecutive elastic collisions between the neutron and the target, including the information of two consecutive recoil ion tracks and the vertex position of the third collision or two consecutive elastic collisions with the timing information. Here, we also include the additional possibility of measuring the deposited energies from the recoil ions. In this paper, we simulate the neutron elastic scattering using the Monte Carlo N-Particle Transport Code (MCNP) and study the corresponding neutron detection and tracking efficiency. The corresponding efficiency and the scattering distances are simulated with different target materials, especially natural silicon (92.23%28Si, 4.67%29Si, and 3.1%30Si) and helium-4 (4He). The timing of collision and the recoil ion energy are also investigated, which are important characters for the detector design. We also calculate the ion traveling range for different energies using the software, “The Stopping and Range of Ions in Matter (SRIM)”, showing that the ion track can be most conveniently observed in 4He unless sub-micron spatial resolution can be obtained in silicon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement and Simulation of Ultra-Low-Energy Ion–Solid Interaction Dynamics

Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here, we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low-energy ion implants can be achieved by either lowering the column voltage or decelerating ions using bias while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found, which is due to lattice enrichment with high-stopping-power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way towards much lower implantation energies while maintaining high spatial resolution.

36 MATERIALS SCIENCE↗

Using Multigrain Crystallography to Explore the Microstructural Evolution of the α-Olivine to γ-Ringwoodite Transformation and ε-Mg2SiO4 at High Pressure and Temperature

The introduction of multigrain crystallography (MGC) applied in a laser-heated diamond anvil cell (LH-DAC) using synchrotron X-rays has provided a new path to investigate the microstructural evolution of materials at extreme conditions, allowing for simultaneous investigations of phase identification, strain state determination, and orientation relations across phase transitions in a single experiment. Here, we applied this method to a sample of San Carlos olivine beginning at ambient conditions and through the α-olivine → γ-ringwoodite phase transition. At ambient temperatures, by measuring the evolution of individual Bragg reflections, olivine shows profuse angular streaking consistent with the onset of yielding at a measured stress of ~1.5 GPa, considerably lower than previously reported, which may have implications for mantle evolution. Furthermore, γ-ringwoodite phase was found to nucleate as micron to sub-micron grains imbedded with small amounts of a secondary phase at 15 GPa and 1000 °C. Using MGC, we were able to extract and refine individual crystallites of the secondary unknown phase where it was found to have a structure consistent with the ε-phase previously described in chondritic meteorites.

36 MATERIALS SCIENCE↗

Development of mesopores in superfine grain graphite neutron-irradiated at high fluence

Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.

I. Contescu, Cristian↗

Characterizing the performance of a POPS miniaturized optical particle counter when operated on a quadcopter drone

We first validate the performance of the Portable Optical Particle Spectrometer (POPS), a small light-weight and high sensitivity optical particle counter, against a reference scanning mobility particle sizer (SMPS) for a month-long deployment in an environment dominated by biomass burning aerosols. Subsequently, we examine any biases introduced by operating the POPS on a quadcopter drone, a DJI Matrice 200 V2. We report the root mean square difference (RMSD) and mean absolute difference (MAD) in particle number concentrations (PNCs) when mounted on the UAV and operating on the ground and when hovering at 10 m. When wind speeds are low (less than 2.6 m s –1 ), we find only modest differences in the RMSDs and MADs of 5 % and 3 % when operating at 10 m altitude. When wind speeds are between 2.6 and 7.7 m s –1 the RMSDs and MADs increase to 26.2 % and 19.1 %, respectively, when operating at 10m altitude. No statistical difference in PNCs was detected when operating on the UAV in either ascent or descent. We also find size distributions of aerosols in the accumulation mode (defined by diameter, d, where 0.1 ≤ d ≤ 1 µm) are relatively consistent between measurements at the surface and measurements at 10 m altitude, while differences in the coarse mode (here defined by d > 1 µm) are universally larger. Our results suggest that the impact of the UAV rotors on the POPS PNCs are small at low wind speeds, but when operating under a higher wind speed of up to 7.6 m s –1 , larger discrepancies occur. In addition, it appears that the POPS measures sub-micron aerosol particles more accurately than super-micron aerosol particles when airborne on the UAV. These measurements lay the foundations for determining the magnitude of potential errors that might be introduced into measured aerosol particle size distributions and concentrations owing to the turbulence created by the rotors on the UAV.

47 OTHER INSTRUMENTATION↗