Search NASA⌕ Search

SEARCH · Search NASA

Results for “subcritical experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Health Assessment and Performance Monitoring of Large Machine Diagnostics

Presentation to be given at the CCS-6 Statistical Seminar Series. Regularly maintained and operated diagnostic machines are a backbone of data collection and are a vital component of the Stockpile Stewardship Program’s efforts to better understand nuclear physics. The Cygnus X-ray machine, stationed at the Nevada National Security Site’s U1a underground facility, is one such diagnostic that provides a radiographic capability for the subcritical experiment program. Component failures within Cygnus can result in catastrophic downtime for the diagnostic, affecting performance, schedules, and cost. However, over the years various measurements have been collected on the two Cygnus axes, including voltage and current measurements at different locations, which we believe have predictive power to indicate machine health. We will share preliminary insight into this data and the machine learning approaches we are taking to assess Cygnus’ health, observe declining performance, and predict failures.

97 MATHEMATICS AND COMPUTING↗

Briefing Book: Office of Experimental Sciences

Key to OES science is the advancement of experimental capabilities and vibrant partnerships with other elements of NNSA’s Defense Programs. OES fosters an experimental portfolio that spans the space from small scale studies utilizing tabletop instruments through complex and dynamic high energy density; hydrodynamic; and subcritical experiments on flagship national facilities like Los Alamos Neutron Science Center (LANSCE), National Ignition Facility (NIF), Z machine at Sandia National Laboratories, Dual Axis Radiographic Hydrodynamic Test (DARHT), and the U1a Complex in Nevada. Essential to meeting the deterrence challenges that drive OES is a functional strategy for integration of OES with Defense Programs pursuits in modeling and simulation, engineering and technology maturation, and stockpile and production modernization.

42 ENGINEERING↗

Design of a 7-MV Linear Transformer Driver (LTD) for down-hole flash x-ray radiography.

Pulsed power driven flash x-ray radiography is a valuable diagnostic for subcritical experiments at the Nevada Test Site. The existing dual-axis Cygnus system produces images using a 2.25 MV electron beam diode to produce intense x-rays from a small source. Future hydrodynamic experiments will likely use objects with higher areal mass, requiring increased x-ray dose and higher voltages while maintaining small source spot size. A linear transformer driver (LTD) is a compact pulsed power technology with applications ranging from pulsed power flash x-ray radiography to high current Z-pinch accelerators. This report describes the design of a 7-MV dual-axis system that occupies the same lab space as the Cygnus accelerators. The work builds on a design proposed in a previous report [1]. This new design provides increased diode voltage from a lower impedance accelerator to improve coupling to low impedance diodes such as the self magnetic pinch (SMP) diode. The design also improves the predicted reliability by operating at a lower charge voltage and removing components that have proven vulnerable to failure. Simulations of the new design and experimental results of the 1-MV prototype are presented.

43 PARTICLE ACCELERATORS↗

Additive Manufactured Materials Studies

The production of additively manufactured (AM) materials, is a growing technology that potentially offers more cost effective ways to produce metallic components for various uses. Mechanical properties of some AM metals have been studied, but more work is needed to better understand their dynamic properties as a function of orientation. Due to the melting and reheating of molten metal during fabrication, these materials tend to have internal porosity and slightly different microstructures along the weldments and normal to the weldments that may cause the materials to behave differently than their forged counterparts. The AM process builds up a part layer by layer, which provides opportunities to tailor geometry and optimize structural performance in addition to minimizing the amount of material waste for oddly shaped parts, thereby reducing cost. These advanced materials hold great promise for revolutionizing design, fabrication, and assembly of engineered components and could be used for many NNSA-specific applications including armoring complex elements of nuclear weapons, and customized diagnostic components in subcritical experiments. We have conducted materials studies in collaboration with the University of Nevada, Las Vegas (UNLV) as well as Los Alamos National Laboratory (LANL) under our Site-Directed Research and Development program and the Nevada Science Initiative. We are currently placing emphasis on quantifying how dynamic properties are affected by directionality and porosity of the material. A study of dynamic failure events in forged, layered, and additive manufactured (AM) titanium alloy subject to hypervelocity impact was conducted in collaboration with UNLV. Experiments were conducted using a two stage light-gas gun, 0.22-caliber Lexan projectiles, and different types of titanium target plates. A four-channel Photonic Doppler Velocimetry (PDV) system was used to study the free surface velocities to provide an understanding of the different failure mechanisms in these materials. The experimental measurements were used to validate computational simulations, which describe the behavior of these materials under shock. It was determined that AM, forged titanium, and multi-layered stacks produce similar velocity profiles during the early stage of impact, with the AM targets exhibiting spall at lower velocities and the multi-layered stacks exhibiting vibrations between plates. Simulations of solid and layered forged materials provide a good match to experimental data.

36 MATERIALS SCIENCE↗

Health Assessment and Performance Monitoring of Large Machine Diagnostics

Diagnostic machines are a crucial component of the Stockpile Stewardship Program for data collection, toward the ultimate goal of improving our understanding of nuclear physics. These systems consist of interactions between many complex components, and require regular maintenance for acceptable performance. The Cygnus X-ray diagnostic located at the Nevada National Security Site's U1a underground facility which provides radiographic data for subcritical experiments, is a prime example of these systems. Component degradation and failures within Cygnus can result in system downtime and data loss, affecting schedules and increasing experiment costs. To evade such failures, years worth of data on machine performance has been collected on the two Cygnus axes in the form of voltage and current measurements of Cygnus' various components. Using these as input, we have developed machine learning techniques for assessing the health of Cygnus, with the ultimate goal of predicting declining performance and machine failure.

97 MATHEMATICS AND COMPUTING↗

Development of a thermal neutron scattering law for polyethylene using molecular dynamics simulations

Polyethylene is an organic polymer that has been used as a neutron moderator and reflector material in various assemblies designed to perform critical and subcritical experiments. Neutrons that are produced within an assembly containing polyethylene will interact with its various atomic components (especially hydrogen) to slow down and eventually reach thermal energies. In this work, the thermal neutron scattering cross sections are generated in support of criticality safety analysis of neutronic assemblies that utilize polyethylene. Polyethylene is composed of ethylene (C{sub 2}H{sub 4}) monomers that are attached in long molecular chains producing the polymer structure. The principle neutron scatterer in this material is hydrogen. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Criticality Eigenvalue Simulations for Subcritical Benchmark Evaluations

Subcritical multiplication experiments and simulations are important for a variety of applications including nonproliferation, safeguards, and criticality safety monitoring. Recently, subcritical experiments have been evaluated for inclusion in the International Criticality Safety Benchmark Evaluation Process (ICSBEP). In addition, new subcritical experiments have recently been designed. In these experiments, list-mode data (a list of each absorption in the neutron detector) is recorded and neutron noise analysis is used to determine the leakage multiplication (ML) of each configuration. One downside to the simulation of these types of experiments is that they are computationally expensive. This is because analog Monte Carlo with no variance reduction must be performed in order to maintain the time accuracy required in the measurement analysis. This work demonstrates that criticality eigenvalue simulations can be used to estimate sensitivities and uncertainties for three parameters: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), and leakage multiplication (M{sub L}). This will provide a useful aid both in the design and evaluation of new subcritical measurements. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical and Subcritical 0-Power Experiment at Rensselaer (CaSPER)

This report discusses the 0-power experiment at Rensselaer Polytechnic Institute (CaSPER). K eff simulation results, list-mode multiplication results, and related work are included. The aim of the work is subcritical measurements for code and nuclear data validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Current Status of the DOE/NNSA Nuclear Criticality Safety Program Hands-on Criticality Safety Training Courses

In 2011, the US Department of Energy/National Nuclear Security Administration (DOE/NNSA) Nuclear Criticality Safety Program (NCSP) developed and piloted a 2-week nuclear criticality safety (NCS) practitioner course to support training and qualification of new NCS staff. The course was developed in accordance with the American National Standard Institute/American Nuclear Society (ANSI/ANS) standard for NCS training and qualifications (ANSI/ANS-8.26-2007). In 2013, an NCS manager’s course was developed for process supervisors, managers, regulators, and other professionals with NCS-related responsibilities. These courses consist of classroom education, facility training, and hands-on subcritical and critical experiments training. Each course is currently offered twice per year. The 2-week practitioner course offers a week of classroom training, with practical workshops and exercises focused on teaching students how to perform an NCS evaluation. The second week of training involves hands-on critical and subcritical experiments and measurements. The first week is offered in Las Vegas, Nevada, at the DOE Nevada Field Office or the National Atomic Testing Museum. Depending on the student’s clearance level, the second week is offered at Sandia National Laboratory (SNL) (uncleared and L-cleared students) or at the National Criticality Experiments Research Center (NCERC) (Q-cleared students). The 1-week manager’s course is offered at SNL or NCERC, depending on clearance or interest, and includes classroom and hands-on critical and subcritical experiments and measurements. This paper provides an overview and status report for the DOE/NNSA NCSP training courses in NCS and provides information about future course offerings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments Execution Plan (IER-518 CED-3a)

As part of the experiment design and planning, the critical experiment design team (CEDT), as well as additional stakeholders, convened a series of meetings to discuss the goals and requirements of execution for this experiment. The slides from these meetings are attached in Appendix A. The following sections summarize the outcome of those discussions and present the planned experimental configurations and measurements. The stated goals of this experiment are as follows: 1) Measure time-tagged list-mode data for configurations exceeding neutron multiplication of 100; 2) Provide intercomparison between LLNL, LANL, and IRSN detector systems and methodologies; 3) Generate experiment execution report(s) useful to a fundamental physics benchmark for the ICSBEP; 4) Leverage existing critical experiment and detector system benchmarks to limit required modeling and uncertainty analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Subcritical Copper-Reflected-α-phase Plutonium (SCRαP) Integral Experiment Design

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)

42 ENGINEERING↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Integral Experiment Execution (CED-3b Report)

This report documents the experimental configurations and measurements for IER-518: Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments. These measurements involved a series of subcritical configurations at the Sandia Critical Experiments (SCX) facility at Sandia National Laboratories (SNL). The purpose of these measurements was to produce time tagged neutron count data of configurations that exceed a subcritical multiplication of 20, which is the high end of the fundamental physics benchmarks currently available in the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP). These measurements leverage experimental configurations 1 and detector systems 2 from previously accepted ICSBEP benchmark evaluations, allowing evaluations of these measurements to be performed at greatly reduced cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Current Status of the DOE/NNSA Nuclear Criticality Safety Program Hands-On Criticality Safety Training [Abstract]

The U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) Nuclear Criticality Safety Program (NCSP) has conducted two-week Nuclear Criticality Safety (NCS) Practitioner courses since 2011 to support the training and qualification of new NCS staff. The course was developed in accordance with the American National Standard Institute/American Nuclear Society (ANSI/ANS) standard for NCS training and qualifications (ANSI/ANS-8.26-2007). In 2013, an NCS Manager’s course was developed for process supervisors, managers, regulators, and other professionals with NCS-related responsibilities. This course was revised in 2019 for Criticality Safety Officers (CSOs) based on an NCSP Criticality Safety Support Group tasking (2018-01). This course was piloted at the Nevada Field Office and the National Criticality Experiments Research Center (NCERC) in June 2021. These courses consist of the following training components: classroom education, facility training, and hands-on subcritical and critical experiments training. The two-week Practitioner course offers a week of classroom training, with practical workshops and exercises focused on teaching students how to perform an NCS evaluation. The second week of training involves hands-on critical and subcritical experiments and measurements. The first week is offered in Las Vegas, Nevada, at the DOE Nevada Field Office or the National Atomic Testing Museum. Depending on the student’s clearance level, the second week is offered at Sandia National Laboratory (SNL) (uncleared and L-cleared students) or at the National Criticality Experiments Research Center (Q-cleared students). The one-week Manager’s course is offered at SNL or NCERC, depending on clearance or interest, and includes classroom and hands-on critical and subcritical experiments and measurements. This paper provides an overview and status report for the DOE/NNSA NCSP training courses in NCS and to provide information about future course offerings. This paper will also discuss the challenges associated with executing the training courses during the COVID-19 pandemic. The 2-week Practitioner and 1-week manager courses are currently offered twice per year and adjustments are made based upon demand.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Cygnus Dual Beam Radiographic Facility Refurbishment completed at U1A tunnel in Nevada NNSS meeting Level 2 milestone (P-23 Highlights 6/10/12)

A moratorium was placed on U.S. underground nuclear testing in 1992. In response, the Stockpile Stewardship Program was created to maintain readiness of the existing nuclear inventory through several efforts such as computer modeling, material analysis, and subcritical nuclear experiments (SCEs). As in the underground test era, the Nevada National Security Site (NNSS), formerly the Nevada Test Site, provides a safe and secure environment for SCEs by the nature of its isolated and secure facilities. A major tool for SCE diagnosis installed in the 05 drift laboratory is a high energy x-ray source used for time resolved imaging. This tool consists of two identical sources (Cygnus 1 and Cygnus 2) and is called the Cygnus Dual Beam Radiographic Facility (Figs. 2-6). Each Cygnus machine has 5 major elements: Marx Generator, Pulse Forming Line (PFL), Coaxial Transmission Line (CTL), 3-cell Inductive Voltage Adder (IVA), and Rod Pinch Diode. Each machine is independently triggered and may be fired in separate tests (staggered mode), or in a single test where there is submicrosecond separation between the pulses (dual mode). Cygnus must operate as a single shot machine since on each pulse the diode electrodes are destroyed. The diode is vented to atmosphere, cleaned, and new electrodes are inserted for each shot. There is normally two shots per day on each machine. Since its installation in 2003, Cygnus has participated in: 4 Subcritical Experiments (Armando, Bacchus, Barolo A, and Barolo B), a 12 shot plutonium physics series (Thermos), and 2 plutonium step wedge calibration series (2005, 2011), resulting in well over 1000 shots. Currently the Facility is in preparation for 2 SCEs scheduled for this calendar year - Castor and Pollux. Cygnus has performed well during 8 years of operations at NNSS. Many improvements in operations and performance have been implemented during this time. Throughout its service at U1a, major maintenance and replacement of many hardware items were delayed due to programmatic requirements. It is anticipated that Cygnus will be in service at U1a for another 5 years. With this assumption, it was realized that significant resources and effort should be allotted to bring the hardware back to its original condition, or even to improve elements when appropriate. The Cygnus Refurbishment and Enhancement Project started in April, 2011 with the intent to encompass a major overhaul of Cygnus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current Status of the DOE/NNSA Nuclear Criticality Safety Program Hands-On Criticality Safety Training

The U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) Nuclear Criticality Safety Program (NCSP) has conducted two-week Nuclear Criticality Safety (NCS) Practitioner courses since 2011 to support the training and qualification of new NCS staff. The course was developed in accordance with the American National Standard Institute/American Nuclear Society (ANSI/ANS) standard for NCS training and qualifications (ANSI/ANS-8.26-2007). In 2013, an NCS Manager’s course was developed for process supervisors, managers, regulators, and other professionals with NCS-related responsibilities. This course was revised in 2019 for Criticality Safety Officers (CSOs) based on an NCSP Criticality Safety Support Group tasking (2018-01). This course was piloted at the Nevada Field Office and the National Criticality Experiments Research Center (NCERC) in June 2021. These courses consist of the following training components: classroom education, facility training, and hands-on subcritical and critical experiments training. The two-week Practitioner course offers a week of classroom training, with practical workshops and exercises focused on teaching students how to perform an NCS evaluation. The second week of training involves hands-on critical and subcritical experiments and measurements. The first week is offered in Las Vegas, Nevada, at the DOE Nevada Field Office or the National Atomic Testing Museum. Depending on the student’s clearance level, the second week is offered at Sandia National Laboratory (SNL) (uncleared and L-cleared students) or at the National Criticality Experiments Research Center (Q-cleared students). The one-week Manager’s course is offered at SNL or NCERC, depending on clearance or interest, and includes classroom and hands- on critical and subcritical experiments and measurements. This paper provides an overview and status report for the DOE/NNSA NCSP training courses in NCS and to provide information about future course offerings. This paper discusses the challenges associated with executing the training courses during the COVID-19 pandemic. The 2-week Practitioner and 1-week manager courses are currently offered twice per year and adjustments are made based upon demand.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗