Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Comptonization model for the submillimeter background

A new measurement of the submillimeter portion of the cosmic microwave background by Matsumoto et al. (1988) indicates that there may be a large excess of energy over that of a blackbody spectrum of temperature 2.74 K. Several models are presented with cosmological heat sources which produce Compton y-distortions large enough to fit the submillimeter background. The models adopt generic forms for these heat sources in terms of the expansion rate and the energy density of other forms of matter in the universe. A specific realization of the models in terms of a decaying vacuum is presented. Unique thermal histories are predicted in which the universe does not globally recombine. A rise in the spectrum at long wavelengths due to free-free emission of the hot intergalactic medium is predicted, and the accompanying mu-distortions are estimated.

Bartlett, James G.↗

Fabrication and optimization of a whiskerless Schottky barrier diode for submillimeter wave applications

The following accomplishments were made towards the goal of an optimized whiskerless diode chip for submillimeter wavelength applications. (1) Surface channel whiskerless diode structure was developed which offers excellent DC and RF characteristics, reduced shunt capacitance and simplified fabrication compared to mesa and proton isolated structures. (2) Reliable fabrication technology was developed for the surface channel structure. The new anode plating technology is a major improvement. (3) DC and RF characterization of the surface channel diode was compared with whisker contacted diodes. This data indicates electrical performance as good as the best reported for similar whisker contacted devices. (4) Additional batches of surface channel diodes were fabricated with excellent I-V and reduced shunt capacitance. (5) Large scale capacitance modelinng was done for the planar diode structure. This work revealed the importance of removing the substrate gallium arsenide for absolute minimum pad capacitance. (6) A surface channel diode was developed on quartz substrate and this substrate was completely removed after diode mounting for minimum parasitic capacitance. This work continues with the goal of producing excellent quality submillimeter wavelength planar diodes which satisfy the requirements of easy handling and robustness. These devices will allow the routine implementation of Schottky receivers into space-based applications at frequencies as high as 1 THz, and, in the future, beyond.

Bishop, W.↗

Excitation of millimeter and submillimeter water masers

The excitation of maser emission in millimeter and submillimeter transitions of interstellar and circumstellar water is considered. An escape probability method is used to determine the equilibrium populations in 349 rotational states of both ortho- and para-water under varying conditions of gas temperature, density, water abundance, and radiation field. It is shown that, under those conditions believed to prevail around late-type stars and within star-forming regions, strong millimeter and submillimeter water maser emission can be generated by collisional excitations by H2. Several maser transitions can have strengths close to that of the 22 GHz line. The water maser line which can be observed from mountaintop facilities and those which will require air- or space-borne platforms are indicated. The exact portion of parameter space in which each maser transition exhibits peak emission is shown.

Neufeld, David A.↗

Planar Schottky barrier mixer diodes for space applications at submillimeter wavelengths

Available planar diodes for space-based applications at submillimeter wavelengths have not achieved either the required low junction capacitance or the low series resistance-junction capacitance product. Here, the development of a novel planar diode structure that overcomes both of these difficulties is outlined. The characteristics of these Schottky barrier mixer diodes are presented and electron micrographs are shown. The diode structure will allow planar technology to be extended throughout the submillimeter wavelength range.

Bishop, W. L.↗

The Precision Segmented Reflector program - On-orbit thermal behavior of the Submillimeter Imager and Line Survey telescope

The Precision Segmented Reflector program and the Submillimeter Imager and Line Survey mission are overviewed. The temperature requirements, thermal design and environment, as well as the on-orbit thermal performance of a 3.65-m-diameter passively-cooled submillimeter-wavelength telescope are discussed, and focus is placed on the geometric and thermal mathematical models employed in the study. Attention is given to an inflatable space-rigidized sunshade protecting the primary mirror thermally and the highly elliptical orbit chosen to reduce heat input from the earth. Primary-reflector temperature predictions are shown to indicate that a large spatial gradient can exist and the magnitude of the gradient is a strong function of the telescope pitch angle. It is suggested that the cryostat outer-shell temperature may be further lowered with the introduction of a rectangular shield between a solar array and the cryostat.

Tsuyuki, G.↗

A wide-band monolithic quasi-optical power meter for millimeter- and submillimeter-wave applications

A novel monolithic power meter has been developed for submillimeter-wave applications (100 GHz to 10 THz). The detector is a large-area bismuth bolometer integrated on a 1.2-micron-thick dielectric membrane. This approach results in a wide-band, high-responsivity detector. The power meter is simple to fabricate, is inexpensive, and can be easily calibrated using a low-frequency network. Quasi-optical measurements at 90, 140, and 240 GHz show that the bolometer is polarization-independent and could be modeled by a simple transmission line model. Absolute power measurements at 90, 140, and 240 GHz show a + or - 5 percent accuracy and agree well with a calibrated Anritsu power meter at 90 GHz. Potential application areas are power calibration, antenna coupling efficiency measurements, and absolute power measurements from solid-state devices and far-infrared lasers at submillimeter wavelengths. Absolute output power measurements on a 220-280 GHz tripler using the quasi-optical power meter are presented as an application example.

Ling, Curtis C.↗

Radiative transfer in planetary atmospheres: Submillimeter-wave spectroscopy of comets

During 1990, a significant step was made in asertaining the molecular composition of comets by our Planetary Astronomy group at the University of Massachusetts. We obtained several exciting new detections of submillimeter wave spectral lines from molecules in the coma of Comet Levy (1990c) using the 10m telescope of the Caltech Submillimeter Observatory, located on Mauna Kea. The molecules HCN, formaldahyde, and methanol were all detected in abundances that make them important minor constituents of the nucleus. Moreover, the emission was so strong that, for the first time, it was possible to map the distribution of these species in the coma and study their behavior as they flow outwards from the nucleus.

Schloerb, F. Peter↗

Applications of submillimeter wave technology for SDI

This paper examines the potential use of using submillimeter wave technology (actually 3 mm to 100 microns, or frequencies between 100 GHz and 3 THz) for SDI applications, especially for endo-KEW systems. The requirements and functions for a multipurpose weapon sensor are considered. The emphasis is on active sensors, but certain elements of passive sensors are mentioned that could play an important role. The rest of the paper provides information on the state-of-the-art in submillimeter wave technology, especially current component activity, and future plans.

Kile, J. N.↗

Space-qualified submillimeter radiometer

The purpose of this research was to develop a reliable submillimeter wave spectrometer for space-borne high frequency spectral line work. The emphasis was on improving the efficiency of frequency multipliers to limit the system components to rugged, low power consumption solid-state devices. This research has allowed Millitech to develop increased efficiency and performance in Millitech's existing line of submillimeter components and systems. Millitech has fabricated and tested a complete solid-state spectrometer front end for use at 560 GHz (the 1(sub 10) to 1(sub 01) transition of water vapor). The spectrometer was designed with the rigors of flight conditions in mind. The spectrometer uses a phase-locked, solid-state Gunn diode oscillator as the local oscillator, employing a tripler to produce about 3 mW of power at 285 GHz, and a low noise second harmonic waveguide mixer which requires less than 2 mW of LO power. The LO (and the signal) is injected into the mixer by means of a quasioptical diplexer. The measured system noise temperature is 2800 K (DSB) over 400 MHz. The whole spectrometer front end is compact (21 cm by 21 cm by 24 cm), light (7.4 kg), and has a power consumption of less than 8 W. Other topics explored in this work include compact frequency agile phase lock loops, optical filters, and InP Gunn oscillators for low noise applications. As a result of this research, the improvement in the design of multipliers and harmonic mixers will allow their use as the LO power for a variety of satellite-borne receivers operating in the 200 to 600 GHz frequency range.

Huguenin, G. R.↗

Submillimeter molecular line observations of cometary Levy (1990c)

Observations of HCN and H2CO in Comet Levy (1990c) obtained at the Caltech Submillimeter Observatory during August 1990 are presented. The HCN J=3-2 rotational line was measured at high spectral resolution (0.1 km/s) and mapped at 13 points over a region of approximately 1.5 arcmin. Analysis of the line profile and the map suggest only slight deviations from the distribution expected for isotropic outgassing of HCN from the nucleus at a velocity of 0.7 plus or minus 0.1 km/s. Observations of the HCN J=4-3 and H2CO5(sub 15)4(sub 14) transitions were obtained simultaneously on two days following the HCN J=3-2 measurements. These transitions are the first submillimeter spectral lines to be detected in a comet. Five point maps of the emission show good consistency between the J=3-2 and J=4-3 HCN observations for an HCN production rate of 2 x 10(exp 26) and a rotational temperature of approximately 30 K. The map of H2CO emission indicates that it is more extended than the prediction of models in which H2CO originates entirely from the nucleus. H2CO may also originate from an extended source in the coma.

Schloerb, F. Peter↗

A fixed tuned broadband matching structure for submillimeter SIS receivers

We have designed, fabricated, and tested a quasi-optical spiral antenna mixer with a Nb/AlO(x)/Nb tunnel junction. This design incorporates a hybrid antenna fed by a planar logarithmic spiral antenna to couple to the radiation field, as previously done with Pb based devices, as well as a newly designed matching circuit. This matching circuit is a relatively complex structure requiring several layers of photolithographic processing on top of the actual tunneling device. Computer modeling of the device predicted the measured bandwidth to within 8 percent, making scale model measurements unnecessary. We have obtained a good match from 210 GHz to 460 GHz between the antenna and a relatively large area (1.25 by 1.25 sq microns) tunnel junction with omega R(sub N) C approx. = 2 - 4.4. This compares to simple inductive stubs that attain only a few percent of total bandwidth in the submillimeter band or inductively tuned SIS arrays with an upper limit of operating frequencies well below the submillimeter band. Noise temperatures were measured at 345 GHz, 426 GHz, and 492 GHz yielding double sideband noise temperatures at 200 K, 220 K, and 500 K, respectively.

Buettgenbach, Thomas H.↗

Silicon micromachined waveguides for millimeter and submillimeter wavelengths

The majority of radio receivers, transmitters, and components operating at millimeter and submillimeter wavelengths utilize rectangular waveguides in some form. However, conventional machining techniques for waveguides operating above a few hundred GHz are complicated and costly. This paper reports on the development of silicon micromachining techniques to create silicon-based waveguide circuits which can operate at millimeter and submillimeter wavelengths. As a first step, rectangular WR-10 waveguide structures have been fabricated from (110) silicon wafers using micromachining techniques. The waveguide is split along the broad wall. Each half is formed by first etching a channel completely through a wafer. Potassium hydroxide is used to etch smooth mirror-like vertical walls and LPCVD silicon nitride is used as a masking layer. This wafer is then bonded to another flat wafer using a polyimide bonding technique and diced into the U-shaped half wavelengths. Finally, a gold layer is applied to the waveguide walls. Insertion loss measurements show losses comparable to those of standard metal waveguides. It is suggested that active devices and planar circuits can be integrated with the waveguides, solving the traditional mounting problems. Potential applications in terahertz instrumentation technology are further discussed.

Yap, Markus↗

A fixed tuned broadband matching structure for submillimeter SIS receivers

The authors have designed, fabricated, and tested a quasi-optical submillimeter wave receiver with an Nb/AlO(x)/Nb tunnel junction. This design incorporates a hybrid antenna fed by a planar logarithmic spiral structure in order to couple to the radiation field from the telescope. The novel matching circuit requires several layers of photolithographic processing on top of the actual tunneling device. Computer modeling of the device correctly predicted the measured bandwidth and the characteristic frequencies to within 8 percent. A good match has been obtained from 200 to 475 GHz between the antenna and a relatively large area (1 sq mm) tunnel junction with omega(R(n))C about 2-4. Noise measurements at 318 GHz, 395 GHz, 426 GHz, and 492 GHz yielded uncorrected double sideband receiver noise temperatures of 200 K, 230 K, 220 K, and 500 K, respectively. Using the same optics, coupling efficiencies between the receiver and the Caltech Submillimeter Telescope were found to have values approaching those achieved by the best waveguide-horn-based receiver systems.

Buttgenbach, Thomas H.↗

Optically pumped submillimeter laser heterodyne receivers - Astrophysical observations and recent technical developments

NASA's prospective sub-mm-wave astrophysical missions encompass the Small Explorer Submillimeter Wave Astronomy Satellite, scheduled for launch in 1995, the Submillimeter Intermediate Mission, and the Large Deployable Reflector; until these are operational, sub-mm observations will be conducted at mountain sites and aboard aircraft platforms. Attention is presently given to the technical challenges faced by terahertz-range receiver developers, and it is noted that optically pumped sub-mm lasers furnish the only practical local oscillation source for heterodyne receivers in the 600-3000 GHz range. An account is given of ground-based and airborne astrophysical applications of heterodyne receivers.

Chin, Gordon↗

Generating Submillimeter-Wave Frequencies From Laser Pulses

Semiconductor photoconductive switches generate electrical pulses containing submillimeter-wavelength carrier signals (frequency between 300 and 3,000 GHz) and harmonics thereof when illuminated with short-rise-time pulses from lasers. Device of this type used as local oscilator in heterodyne submillimeter-wave receiver. Electrical output of device coupled via transmission line, waveguide, or antenna to mixer circuitry of receiver. Phase delays between optically activated semiconductor switches determine output carrier frequencies. N electrical pulses generated by each laser pulse. Thus, fundamental output frequency is N times laser-pulse-repetition rate.

Spencer, Michael G.↗

A monolithic Si bolometer array for the Caltech Submillimeter Observatory

We are developing a submillimeter continuum camera for the Caltech Submillimeter Observatory (CSO) located on Mauna Kea. The camera will employ a monolithic Si bolometer array which was developed by Moseley et al. at the NASA Goddard Space Flight Center (GSFC). The camera will be cooled to a temperature of about 300 mK in a He-3 cryostat, and will operate primarily at wavelengths of 350 and 450 micrometers. We plan to use a bolometer array with 1x24 directly illuminated pixels, each pixel of dimension 1x2 sq mm, which is about half of the F/4 beam size at these wavelengths. Each pixel is 10 to 12 micrometers thick and is supported only by four thin Si legs formed by wet chemical etch. The pixels are doped n-type by phosphorus implantation, compensated by boron implantation. Signals from the bolometer pixels are first amplified by cryogenically cooled FET's. The signals are further amplified by room-temperature amplifiers and then separately digitized by 16 bit A/D converters with differential inputs. The outputs of the A/D converters are fed into a digital signal processing board via fiber-optic cables. The electronics and data acquisition system were designed by the Goddard group. We will report the status of this effort.

Wang, Ning↗

Optically-switched submillimeter-wave oscillator and radiator having a switch-to-switch propagation delay

A submillimeter wave-generating integrated circuit includes an array of N photoconductive switches biased across a common voltage source and an optical path difference from a common optical pulse of repetition rate f sub 0 providing a different optical delay to each of the switches. In one embodiment, each incoming pulse is applied to successive ones of the N switches with successive delays. The N switches are spaced apart with a suitable switch-to-switch spacing so as to generate at the output load or antenna radiation of a submillimeter wave frequency f on the order of N f sub 0. Preferably, the optical pulse has a repetition rate of at least 10 GHz and N is of the order of 100, so that the circuit generates radiation of frequency of the order of or greater than 1 Terahertz.

Spencer, Michael G.↗

Submillimeter heterodyne spectroscopy and remote sensing of the upper atmosphere

Submillimeter-wavelength heterodyne spectroscopy by microwave limb sounding (MLS) from orbiting satellite is a measurement technique for studying Earth's stratosphere, mesosphere and lowerr thermosphere on a global scale. Development and deployment of such tools are timely, as stratospheric ozone shileds life from solar ultraviolet radiation but is depleted by pollution from industrial activities. MLS experiments on NASA's Upper Atmosphere Research Satellite (UARS) and Earth Observing System (EOS) are now being developed and implementend for global monitoring. Atmospheric thermal-emission spectra at millimeter and submillimeter wave-lengths are measured as the instrument field of view (FOV) is scanned through the limb from above. Atmospheric profiles of molecular abundances, temperature, pressure, wind and magnetic field can be determined from the measured emission spectra. Intensity of the emission can provide abundance and temperature. Measured linewidths, and emission from temperature-insensitive O2 lines, can provide pressure. Differentitaion of measured pressure with repsect ot measured height differential (obtaiend from the instrument FOV scan encoder) can also provide temperature through atmospheric hydrostatic equilibrium (which relates temperature to pressure and height differential). Doppler shifts of spectral lines can provide wind, and Zeeman splitting of the magnetic-dipole lines of O2 can provide magnetic field.

Waters, J. W.↗