Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter wavelengths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A large-scale cosmic microwave background anisotropy measurement at millimeter and submillimeter wavelengths

A balloon-borne experiment to measure the anisotropy of the cosmic microwave background radiation at angular scales of 4 deg or greater is reported. The instrument simultaneously measures in four spectral bands centered on 5.6, 8.7, 15.8, and 22.5/cm. Three results are presented: (1) the 95-percent confidence limit for monochromatic anisotropies is 0.0001 or less on angular scales of 10 deg; (2) the Galactic plane dust emission at l = 42 deg is consistent with a nu-squared emissivity law at frequencies above 15/cm, with excess emission below 15/cm; and (3) atmospheric ozone at an altitude of 35 km may form clumps as large as Delta emissivity/emissivity = 0.002.

Page, Lyman A.↗

Slot antenna SIS mixers for submillimeter wavelengths

We are developing improved versions of a slot antenna SIS mixer which we have previously described. The initial work demonstrated a double sideband noise temperature of 420 K for a 500 GHz quasi-optical SIS mixer employing a twin-slot antenna on a quartz dielectric substrate. A quartz hyperhemispherical lens is used to focus the incoming radiation onto the twin-slot antenna. The advantages of a twin-slot antenna include a low impedance (35 omega) and a clean, symmetric beam pattern into the dielectric with a 70 percent efficiency. In our original mixer, the radiation was coupled from the two slot antennas onto superconducting microstrip lines which fed the SIS junction. By performing an impedance transformation using tapered lines and by feeding the radiation from the two slots to the junction in parallel, the effective (real) impedance seen by the junction was reduced to just 4 omega. This very low impedance allowed a junction area of 2.3 sq micron to be used at 500 GHz, which was manufactured using optical lithography. However, no attempt was made to tune out the junction capacitance. We estimate that this capacitance reduces the impedance coupling efficiency to eta(sub Z) approx. equals 0.23, for our junction with omega R(sub N) C = 5.3 at 500 GHz. The recent development of techniques using electron-beam lithography to manufacture junctions with very small areas (approx. equals 0.1 sq microns) now allows considerably more flexibility in the design of SIS mixer circuits. We have redesigned the slot-antenna mixer to take advantage of this possibility. In particular, we have included a novel circuit which allows the junction capacitance to be tune out over a broad bandwidth. For instance, mixers designed for 800 GHz using NbN/MgO/NbN junctions with realistic parameters achieve a 3 dB impedance bandwidth of nearly 400 GHz. Furthermore, our circuit uses only short lengths of microstrip and should be less sensitive to RF losses than other designs. The improved impedance match should give a large reduction in noise temperature as compared to our previous mixer. The new devices are currently under fabrication. Further details of the design and any available experimental results are discussed.

Zmuidzinas, Jonas↗

Submillimeter-wavelength heterodyne spectroscopy and remote sensing of the upper atmosphere

Remote sensing by means of heterodyne spectroscopy at sub-mm wavelengths, which are rich in the spectral lines of atmospheric molecules, can furnish measurements for monitoring changes and studying processes in the earth's upper atmosphere. An experiment for this purpose, covering spectral bands near 63, 183, and 205 GHz, has become operational on the NASA Upper Atmosphere Research Satellite; an experiment whose spectral bands reach to 2.5 THz is under study for future earth observations.

Waters, Joe W.↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Progress by investigators at the Georgia Institute of Technology in the development of techniques for passive microwave retrieval of water vapor, cloud, and precipitation parameters using millimeter- and sub-millimeter wavelength channels is reviewed. Channels of particular interest are in the tropospheric transmission windows at 90, 166, 220, 340, and 410 GHz and centered around the water vapor lines at 183 and 325 GHz. Collectively, these channels have potential application in high-resolution mapping (e.g., from geosynchronous orbit), remote sensing of cloud and precipitation parameters, and retrieval of water vapor profiles. During the period from 1 Jan. 1993 through 30 Jun. 1993 the Millimeter-wave Imaging Radiometer (MIR) completed data flights during a two-month long deployment in conjunction with TOGA/COARE. Coincident data was collected from several other ground-based, airborne, and satellite sensors, including the NASA/MSFC AMPR, MIT MTS, DMSP SSM/T-2 satellite, collocated radiosondes, ground- and aircraft-based radiometers and cloud lidars, airborne infrared imagers, solar flux probes, and airborne cloud particle sampling probes.

Gasiewski, A. J.↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Presented in this study are the results of controlled partially polarimetric measurements of thermal emission at 91.65 GHz from a striated water surface as corroborated by a geometrical optics radiative model. The measurements were obtained outdoors using a precision polarimetric radiometer which directly measured the first three modified Stokes' parameters. Significant variations in these parameters as a function of azimuthal water wave angle were found, with peak-to-peak variations in T(sub u) of up to approximately 10 K. The measurements are well corroborated by the GO model over a range of observations angles from near nadir up to approximately 65 degrees from nadir. The model incorporates both multiple scattering and a realistic downwelling background brightness field.

Gasiewski, Albin J.↗

Planar Schottky technology for submillimeter wavelengths

Work carried out in relation to the development of planar integrated Schottky diodes with the aim of increasing the sensitivity, reliability and efficiency of spaceborne heterodyne receivers, is reported. The results of this work include a planar diode mixer at 585 GHz with a total receiver noise temperature of 2,380 K double side band, and planar diode multipliers. The prospects for further integration of circuit elements with the GaAs diodes are discussed.

Crowe, Thomas W.↗

Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

Bolometer Mixers↗

Array of Bolometers for Submillimeter- Wavelength Operation

A feed-horn-coupled monolithic array of micromesh bolometers is undergoing development for use in a photometric camera. The array is designed for conducting astrophysical observations in a wavelength band centered at 350 m. The bolometers are improved versions of previously developed bolometers comprising metalized Si3N4 micromesh radiation absorbers coupled with neutron- transmutation-doped Ge thermistors. Incident radiation heats the absorbers above a base temperature, changing the electrical resistance of each thermistor. In the present array of improved bolometers (see figure), the thermistors are attached to the micromesh absorbers by indium bump bonds and are addressed by use of lithographed, vapor-deposited electrical leads. This architecture reduces the heat capacity and minimizes the thermal conductivity to 1/20 and 1/300, respectively, of earlier versions of these detectors, with consequent improvement in sensitivity and speed of response. The micromesh bolometers, intended to operate under an optical background set by thermal emission from an ambient-temperature space-borne telescope, are designed such that the random arrival of photons ("photon noise") dominates the noise sources arising from the detector and readout electronics. The micromesh is designed to be a highly thermally and optically efficient absorber with a limiting response time of about 100 s. The absorber and thermistor heat capacity are minimized in order to give rapid speed of response. Due to the minimization of the absorber volume, the dominant source of heat capacity arises from the thermistor.

Bock, James↗

Measurement of CH3D on Titan at Submillimeter Wavelengths

We present the first radio/submillimeter detection of monodeuterated methane (CH3D) in Titan's atmosphere, using archival data from of the Atacama Large Millimeter/submillimeter Array (ALMA). The J (sub K) equals 2 (sub 1) minus 1 (sub 1) and J (sub K) equals 2 (sub 0) minus 1 (sub 0) transitions at 465.235 and 465.250 gigahertz (approximately 0.644 millimeters) were measured at significance levels of 4.6 sigma and 5.7 sigma, respectively. These two lines were modeled using the Non-linear optimal Estimator for MultivariatE spectral analySIS (NEMESIS) radiative transfer code to determine the disk-averaged CH3D volume mixing ratio equals 6.157 times 10 (sup minus 6) in Titan's stratosphere (at altitudes greater than 130 kilometers). By comparison with the CH4 vertical abundance profile measured by Cassini-Huygens mass spectrometry, the resulting value for D/H in CH4 is (1.033 plus or minus 0.081) times 10 (sup minus 4). This is consistent with previous ground-based and in situ measurements from the Cassini-Huygens mission, though slightly lower than the average of the previous values. Additional CH3D observations at higher spatial resolution will be required to determine a value truly comparable with the Cassini-Huygens CH4 measurements, by measuring CH3D with ALMA close to Titan's equator. In the post-Cassini era, spatially resolved observations of CH3D with ALMA will enable the latitudinal distribution of methane to be determined, making this an important molecule for further studies.

Thelen, Alexander E.↗

Probing Galaxy Formation and Submillimeter Surveys

Multiwavelength observations of galaxies have revealed that a significant fraction of the their stellar or accretion luminosity is absorbed and reradiated by dust at far-infrared (FIR) and submillimeter (submm) wavelengths. Submillimeter (850 micron) surveys conducted by the SCUBA instrument on the JCMT have detected a population of high redshift (z approximately equal to 1-4) ultraluminous infrared galaxies, that dominate the luminosity densities at those redshifts. Their cumulative contribution to the cosmic infrared background (CIB) detected by the COBE satellite is comparable to the observations, suggesting that at 850 microns the CIB is resolved into its constituent sources. This suggests that the early universe was much more dust enshrouded than the present one. FIR and submm surveys can therefore address fundamental questions regarding the early processes of galaxy formation and their evolution in number and luminosity over cosmic history. The scientific information that can be obtained from such surveys depend on a number of parameters, the most important of which are the diameter of the telescope and the wavelengths of the survey. We summarize the effect of these parameters on the scientific return from such surveys.

Dwek, Eli↗

Subaru Imaging of Asymmetric Features in a Transitional Disk in a Transitional Disk in Upper Scorpius

We report high-resolution (0.07 arcsec) near-infrared polarized intensity images of the circumstellar disk around the star 2MASS J16042165−2130284 obtained with HiCIAO mounted on the Subaru 8.2 m telescope. We present our H-band data, which clearly exhibit a resolved, face-on disk with a large inner hole for the first time at infrared wavelengths.We detect the centrosymmetric polarization pattern in the circumstellar material as has been observed in other disks. Elliptical fitting gives the semimajor axis, semiminor axis, and position angle (P.A.) of the disk as 63 AU, 62 AU, and −14◦, respectively. The disk is asymmetric, with one dip located at P.A.s of ∼85◦. Our observed disk size agrees well with a previous study of dust and CO emission at submillimeter wavelength with Submillimeter Array. Hence, the near-infrared light is interpreted as scattered light reflected from the inner edge of the disk. Our observations also detect an elongated arc (50 AU) extending over the disk inner hole. It emanates at the inner edge of the western side of the disk, extending inward first, then curving to the northeast. We discuss the possibility that the inner hole, the dip, and the arc that we have observed may be related to the existence of unseen bodies within the disk

protoplanetary disks↗

On-Wafer Measurement of a Silicon-Based CMOS VCO at 324 GHz

The world s first silicon-based complementary metal oxide/semiconductor (CMOS) integrated-circuit voltage-controlled oscillator (VCO) operating in a frequency range around 324 GHz has been built and tested. Concomitantly, equipment for measuring the performance of this oscillator has been built and tested. These accomplishments are intermediate steps in a continuing effort to develop low-power-consumption, low-phase-noise, electronically tunable signal generators as local oscillators for heterodyne receivers in submillimeter-wavelength (frequency > 300 GHz) scientific instruments and imaging systems. Submillimeter-wavelength imaging systems are of special interest for military and law-enforcement use because they could, potentially, be used to detect weapons hidden behind clothing and other opaque dielectric materials. In comparison with prior submillimeter- wavelength signal generators, CMOS VCOs offer significant potential advantages, including great reductions in power consumption, mass, size, and complexity. In addition, there is potential for on-chip integration of CMOS VCOs with other CMOS integrated circuitry, including phase-lock loops, analog- to-digital converters, and advanced microprocessors.

Samoska, Lorene↗

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗