Search NASA⌕ Search

SEARCH · Search NASA

Results for “superconducting RF cavities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

On forced RF generation of CW magnetrons for SRF accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost of RF power per Watt than used traditionally klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain to start up reliably with self-excitation even if the tube is powered by a DC power supply. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a signal PLock ≤ -20 dB or less then of the magnetron power PMag. Then the magnetron generates the injection locked oscillations and generates noise. This may preclude use of standard CW magnetrons in some SRF accelerators. We developed briefly described below a mode for forced coherent RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

Kazakevich, G.↗

On forced RF generation of CW magnetrons for accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a quite large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally, an injection locking by a small signal is used for stabilization of magnetrons. In this case CW magnetrons with the injection-locked oscillations generate a high level of noise. This may preclude use of standard CW magnetrons in this operating mode in the Superconducting RF (SRF) accelerators. In this article we described a method developed for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The method is most suitable for powering high Q-factor cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum-Enhanced Dark-Matter Sensing with Large Photon Number Fock States in a High-Q SRF Cavity

Wave-like dark matter candidates such as axions or dark photons in the microwave frequency range can be probed using resonant superconducting cavities. We demonstrate a quantum-enhanced sensing approach based on a multimode, high-Q superconducting RF (SRF) cavity, where a large Fock state is prepared in the storage mode via sideband transitions mediated by a transmon ancilla and a measurement-based feedforward protocol, achieving high-fidelity Fock states [1]. The prepared |n⟩ state induces stimulated emission from the dark-matter field, providing an (n + 1) enhancement in transition probability and proportional boost in signal rate [2]. A secondary cavity mode functions as an in-situ reference to calibrate noise. We present the control sequence, noise-referencing strategy, and projected sensitivity improvements for axion and dark-photon detection. This multimode architecture combines large Fock state preparation with noise calibration, offering a practical path to increased scan rate in cavity-based dark-matter searches.

Kim, Taeyoon↗

On Forced RF Generation of CW Magnetrons for SRF Accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a quite small signal. Then the magnetron except the injection locked oscillations may generate noise. This may preclude use of standard CW magnetrons in some SRF accelerators. Recently we developed briefly described below a mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

43 PARTICLE ACCELERATORS↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗

Key directions for research and development of superconducting radio frequency cavities

Radio frequency superconductivity is a cornerstone technology for many future HEP particle accelerators and experiments from colliders to proton drivers for neutrino facilities to searches for dark matter. While the performance of superconducting RF (SRF) cavities has improved significantly over the last decades, and the SRF technology has enabled new applications, the proposed HEP facilities and experiments pose new challenges. To address these challenges, the field continues to generate new ideas and there seems to be a vast room for improvements. In this paper we discuss the key research directions that are aligned with and address the future HEP needs.

43 PARTICLE ACCELERATORS↗

591 MHz SRF Cavity Design for the EIC ESR

The Electron-Ion Collider (EIC) is a next generation particle accelerator to be built at Brookhaven National Laboratory, in partnership with Thomas Jefferson National Accelerator Facility. The Electron Storage Ring (ESR) of RIC requires a 10 MW RF storage system to restore beam power lost by a 2.5 A electron beam. The RF system will use 18 single-cell 591 MHz Superconducting RF (SRF) cavities. Effective damping of higher-order-modes (HOMs) is critical to ensure beam stability. This paper presents the design of the single-cell 591 MHz cavity, including cavity geometry optimization, multipacting evaluation, and HOM damping analysis.

43 PARTICLE ACCELERATORS↗

Impedance and wakefield studies of the EIC RCS 591 MHz five-cell cavity

The Electron-Ion Collider (EIC) is a next-generation accelerator complex designed to enable high-luminosity collisions between highly polarized electrons and light ions (e.g., He-3). A central component of its Electron Injection System (EIS) is the Rapid Cycling Synchrotron (RCS), which accelerates a single 28 nC electron bunch from 750 MeV to 5, 10, or 18 GeV using an array of 591 MHz five-cell superconducting RF (SRF) cavities—eight at the current design stage. To ensure stable acceleration of high-charge bunches, we conducted detailed impedance and wakefield studies of the SRF cavity structure using both frequency- and time-domain methods. Wakefield solvers (ECHO3D, ECHO1D, CST), eigenmode analysis, and multi-particle tracking with ELEGANT were employed to evaluate longitudinal and transverse impedance effects and to determine instability thresholds. These studies provide critical input for the cavity design and operating parameters required to preserve beam quality and stability in the RCS.

Accelerator Physics↗

SRF Levitation and Trapping of Nanoparticles Experiment

The levitation and trapping of micro particles using lasers is not a new accomplishment and has been applied in containerless processing and spectroscopy of microparticles. Recent developments in the field of optomechanics have achieved levitating nanoparticles such that quantum phenomena was observed which would have relevance in quantum science and technology. This two-year project sought to levitate and trap mesoscopic particles using radio frequency (RF) fields in a resonating superconducting RF (SRF) cavity. By exploiting the intrinsic characteristics of an SRF resonating cavity, the project was to explore overcoming a major limit faced by current laser trapping techniques. The goal was to establish a foundation to enable the observation of quantum phenomena of an isolated mechanical oscillator interacting with microwave fields. If successful the experiment could establish its ground-breaking relevance to quantum information science and technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nb$^{3}$Sn Technology for Low-beta linacs

Nb3Sn is the most advanced potential successor for niobium in superconducting RF accelerator cavities. Nb3Sn has a significantly higher critical temperature (18.3 K) compared to that of niobium (9.2 K). This has a large effect on the BCS surface resistance, and therefore, on the dynamic RF losses at 4.5 K. The higher critical temperature allows two important changes for cavity and cryomodule design. First, the lower BCS losses allow the designer to use a higher frequency, translating to physically smaller cavities and cryomodules. Second, the low dynamic losses allow the use of stand-alone cryocoolers instead of complex helium refrigerators and distribution systems. Fabrication of a prototype 218 MHz cavity, test results, and continuing challenges are discussed.

43 PARTICLE ACCELERATORS↗

A Novel Technique for Pulsed Operation of Magnetrons without Modulation of Cathode Voltage

Modern pulsed superconducting accelerators of megawatt beams require efficient RF sources controllable in phase and power. For each Superconducting RF (SRF) cavity is desirable a separate RF source with power up to hundreds of kW with pulse duration in the millisecond range. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) is lower than that of the magnetrons, while the cost of a unit of RF power is much higher. Therefore the magnetron-based RF sources would significantly reduce the capital and operation costs in comparison with the traditional RF sources. A recently developed an innovative technique makes possible the pulsed generation of magnetrons powered below the self-excitation threshold voltage. This technique does not require pulse modulators to form RF pulses. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in pulsed modes with large duty factor. The developed technique and its experimental verification are considered and discussed.

43 PARTICLE ACCELERATORS↗

ERL-Based Compact X-Ray FEL

We propose to develop an energy-recovery-linac (ERL)-based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗

SRF Levitation and Trapping of Nanoparticles

A proposal has been conceived to levitate and trap mesoscopic particles using radio frequency (RF) fields in a superconducting RF(SRF) cavity. Exploiting the intrinsic characteristics of an SRF cavity, this proposal aims at overcoming a major limit faced by state-of-the-art laser trapping techniques. The goal of the proposal is to establish a foundation to enable observation of quantum phenomena of an isolated mechanical oscillator interacting with microwave fields. An experiment supported by LDRD funding at JLab has started to address R&D issues relevant to these new research directions using existing SRF facilities at JLab. The success of this experiment would establish its groundbreaking relevance to quantum information science and technology, which may lead to applications in precision force measurement sensors, quantum memories, and alternative quantum computing implementations with promises for superior coherence characteristics and scalability well beyond the start-of-the-art. In this contribution, we will introduce the proposal and basic consideration of the experiment.

Geng, R. L.↗

First Experience with Liquid Nitrogen Cleaning

Field emission caused by microscopic particulate contamination is a limiting factor for the performance of superconducting RF (SRF) cavities. In an SRF based accelerator, particulates may be transported over the surface of an operational SRF cavity, becoming field emitters and consequentially degrading the performance of the SRF cavity. The most commonly used method for removing particulates from cavity surfaces is high-pressure ultra-pure water rinsing. We are developing a novel high-pressure liquid nitrogen cleaning technique that may possibly enable superior cleaning power and particulate removal from cavities in a cryomodule without taking apart the cryomodule components. This technique provides cleaning mechanisms beyond what are accessible by its high-pressure water rinsing counterpart and leaves no residues on the cleaned surface.

Ruber, R.J.M.Y.↗

Large Scale Simulations of Quantum Systems on HPC with Analytics for HEP Algorithms

The objective of this work is to combine HEP simulation experience with HPC quantum systems simulations to provide an environment for executing large-scale experiments with advanced analysis capabilities for studying multi-qubit and multi-level reduced-noise, long coherence time quantum systems such as 3D Superconducting RF (SRF) cavities integrated with transmon qubits.

97 MATHEMATICS AND COMPUTING↗

LLRF System Analysis for the Fermilab PIP-II LINAC

Developing long-lived quantum processing units (QPUs) capable of supporting high-fidelity quantum operations is a crucial challenge on the path toward fault-tolerant quantum computing. TESLA-shaped superconducting RF (SRF) cavities, known for photon relaxation times on the order of seconds, provide an excellent foundation for 3D QPUs and quantum memory. This talk presents a novel design that leverages TESLA cavity modes coupled to ancillary transmon qubits, optimized to preserve coherence and control. By carefully engineering the package geometry, optimizing Hamiltonian parameters, and minimizing lossy participation ratios, we achieve photon relaxation times of over 16 ms and 20 ms for the two cavity modes, representing a significant improvement over previous multimode quantum memories. Despite the reduced coupling between the qubit and cavity modes, which is necessary to preserve long lifetimes, the platform supports robust and universal control schemes that are not limited by low coupling strength. We will also discuss how this architecture can lead to scalable, modular quantum computing systems.

Varghese, P. [Fermilab]↗

Effect of Electropolishing on Nitrogen Doped and Undoped Niobium Surfaces

Cold electropolishing (EP) of a nitrogen-doped (N-doped) niobium (Nb) superconducting RF (SRF) cavity was found to improve its quality factor. In order to understand the effect of EP temperature on N-doped and undoped surfaces, a systematic EP study was conducted with 2/0 N-doped and heat-treated Nb samples in a beaker. The Nb samples were electropolished at different surface temperatures ranging from 0 to 42 C. The results showed that the doped surface was susceptible to the sample temperature during EP. EP resulted in the surface pitting on the doped samples where the number density of pits increased at a higher temperature. The surface results were compared with the surface of cutouts from a 9-cell cavity which was 2/0 N-doped and electropolished. This paper shows de-tailed surface features of the N-doped and undoped Nb surfaces electropolished at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗