Search NASASearch

SEARCH · Search NASA

Results for “superconducting quantum interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters

Atomic Layer Deposition Josephson Junctions for Cryogenic Circuit Applications

Superconducting-insulating-superconducting (SIS) trilayers have been produced for Josephson Junction fabrication by thermal atomic layer deposition (ALD) processes. The trilayers are composed of alternating layers of Ti0.4N0.6/Al2O3/ Ti0.4N0.6, deposited at 450°C, in a thermal ALD reactor on Al2O3-coated silicon. The conformal nature of the ALD process provides excellent step coverage of superconducting and insulating films. The film thickness of a single ALD cycle being one mono-layer, allows us to precisely control the tunnel-barrier insulator thickness by counting the number of ALD cycles during the insulator deposition step. Tunnel-junctions with critical current 500 A/cm2 are reported. Fabrication of Josephson Junctions and progress toward development of a single-element ALD Superconducting Quantum Interference Device (SQUID) will be discussed

Atomic Layer Definition

Microwave SQUID Multiplexing for the Lynx X-Ray Microcalorimeter

The Lynx x-ray microcalorimeter (LXM) is an imaging spectrometer for the Lynx satellite mission, an x-ray telescope being considered by NASA to be a new flagship mission. Lynx will enable unique astrophysical observations into the x-ray universe due to its high angular resolution and large field of view. The LXM consists of an array of over 100,000 pixels and poses a significant technological challenge to achieve the high degree of multiplexing required to read out these sensors. We discuss the details of microwave superconducting quantum interference device (SQUID) multiplexing and describe why it is ideally suited to the needs of the LXM. This case is made by summarizing the current and predicted performance of microwave SQUID multiplexing and describing the steps needed to optimize designs for all the LXM arrays. Finally, we describe our plan to advance the technology readiness level (TRL) of microwave SQUID multiplexing of the LXM microcalorimeters to TRL-5 by 2024.

Bennett, Douglas A.

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 sq. m of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

Simon R. Bandler

Accelerating the Deployment of Space-Based Quantum Sensors

Quantum sensors rely on quantum mechanical properties, such as wave-particle duality, atomic energy levels, or entanglement, to measure physical, optical, or electromagnetic information from a target. Examples include Rydberg sensors, nitrogen-vacancy magnetometers, HOM (Hong-Ou-Mandel) interferometers, and SQUIDs (Superconducting Quantum Interference Devices). In general, as quantum sensors rely on interrogation at the atomic and photonic level rather than on classical mechanical measurements, these technologies promise advantages over their traditional counterparts in sensitivity, accuracy, and SWaP (Size, Weight, and Power). Conceptually, the use of quantum sensors unlocks the new phenomenology of sensor entanglement. While an ultra-low TRL (Technology Readiness Level) prospect for most sensor types, multi-sensor entanglement is a high risk, high reward strategy with a potential for exquisite sensitivity and SWaP improvements entirely inaccessible to classical sensors.

Grace Caroline Wusk

QUPITER -- Space Quantum Sensors for Jovian-Bound Dark Matter

We propose utilizing space quantum sensors to detect ultralight dark matter (ULDM) bound to planetary bodies, focusing on Jupiter as the heaviest planet in the solar system. Leveraging Jupiter's deep gravitational potential and the wealth of experience from numerous successful missions, we present strong sensitivity projections on the mass and couplings of scalar ULDM. Future space missions offer unique opportunities to probe the ULDM interactions using quantum sensors, including superconducting quantum interference device (SQUID) magnetometers. By measuring dark matter-induced magnetic field oscillations, we expect to achieve sensitivity orders of magnitude beyond the terrestrial probes and significantly improve detection prospects of theoretically motivated ULDM candidates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Superconducting (Ba,K)Fe 2 As 2 epitaxial films on single and bicrystal SrTiO 3 substrates

The realization of single crystal and bicrystal films of superconducting materials is of great interest because they allow the investigation of the intragrain performance as well as the understanding of potential limitations in the grain boundary transparency. For many years, the realization of a high-quality (Ba,K)Fe 2 As 2 film has been challenging. Here, the realization of (Ba,K)Fe 2 As 2 epitaxial thin films on single crystal SrTiO 3 (001) and [001]-tilt-type SrTiO 3 bicrystal substrates with high superconducting properties is demonstrated. The epitaxial growth of (Ba,K)Fe 2 As 2 was enabled by implementing an undoped BaFe 2 As 2 buffer layer between the SrTiO 3 substrate and (Ba,K)Fe 2 As 2 film. The film exhibits a high T c of 38.0 K and an extremely high J c of 14.3 MA/cm 2 at 4.2 K. Artificial grain boundaries of (Ba,K)Fe 2 As 2 were also successfully achieved on bicrystals with misorientation angles up to 36.8° by the same preparation methods. The artificial grain boundaries exhibited an identical T c of 38.0 K and an excellent transfer of the grain orientation from the bicrystal substrates with high crystallinity comparable to that of the high-quality Ba(Fe,Co) 2 As 2 films. Furthermore, this enables the investigation of the intrinsic (Ba,K)Fe 2 As 2 grain boundary nature, which will clarify its potential for superconducting applications, like Josephson junctions, wires, and magnets.

(Ba,K)Fe2As2

Ultra-Stable Superconducting-Maser Oscillator

Unprecedented stability of frequency in superconducting, triple-cavity ruby maser oscillator achieved by incorporation of amplitude-control subsystem. New design enhances ultra-stable measurements of time by reducing fluctuations to 2 X 10 to negative 19th power routinely, and to as little as 10 to negative 20th power in exceptional cases. Currents induced in superconducting pickup coil by changes in magnetic field in ruby. Currents from coil fed to superconducting quantum-interference device (SQUID) magnetometer, output used to generate control signal for electronically variable attenuator. Attenuator varies pump-signal amplitude in response to magnetic-field fluctuations in ruby. Very high feedback-loop gain used for sensitivity of control and adequate compensation of fluctuations.

Strayer, Donald M.

Recent Results of a New Microwave SQUID Multiplexer

We are developing a proof-of-concept microwave SQUID multiplexer containing four SQUIDs coupled to GHz frequency resonant circuits and fed with a single microwave readout line. The resonators are half-wave coplanar waveguide sections and are similar to the structures used for the microwave kinetic inductance detectors developed in our group. Optimal values for the interdigital gap capacitors were determined to maximize the sensitivity of the transmitted and reflected microwave signal with respect to changes in the dynamic resistance of the SQUID. The dc current-bias line for the SQUID has an in-line inductive high frequency filter to minimize coupling between the bias line and resonator. A high frequency modulation scheme is proposed to eliminate the need for individual flux biasing of the SQUIDs, which extends the dynamic range of the readout. In this scheme a common modulation signal is imposed on each SQUID and the received signal is demodulated at one and two times the modulation frequency to maintain sensitivity at any flux state. We present the recent results of the microwave SQUID multiplexer system operating at a readout frequency range of 10 - 11GHz.

superconducting quantum interference device (SQUID

Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays

Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.

Transition-edge sensors

Magnetic flux penetration into superconducting thin films.

The quantum-interference technique developed by Meservey (1965) is used to measure directly the absolute value of the penetration depth in lead in tin superconducting thin films. The technique assumes that the change in phase of the superconducting wave function around any contour within the superconductor must be 2 pi n, where n is a nonnegative integer. Results show that the critical current of a superconducting interferometer with two parallel junctions is not strictly periodic in the applied magnetic flux with a period equal to the flux quantum because of the magnetic field dependence of the critical currents of the junctions.

Peabody, G. E.

Discovery of an unconventional quantum echo by interference of Higgs coherence

Detecting photon echoes from superconducting Higgs modes is challenging due to the necessity of preserving and retrieving phase coherence encoded in multiple Higgs and quasiparticle (QP) excitations. Here, we demonstrate the emergence of a Higgs echo in niobium superconductors. This approach disentangles unique quantum pathways involving the Higgs mode and QP excitations. Using Higgs echo spectroscopy, we also uncover unconventional echo formation caused by inhomogeneous broadening and “soft” QP bands, which dynamically evolve under terahertz (THz) driving. Specifically, THz pulse pairs modulate the superconducting gap, imprinting coherence and forming a temporal “Higgs grating.” This grating produces echoes with distinctive characteristics: (i) echo rephasing spectral peaks at superconducting gap frequencies, (ii) asymmetric echo formation delays unlike those observed in atoms or semiconductors, and (iii) negative-time echo signals stemming from Higgs-QP anharmonic interactions. Combined with advanced time-frequency analysis, these findings distinguish Higgs from QP responses and clarify their intricate interactions in THz-driven superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Self-Field-Induced Josephson Diode Effect

Josephson diodes are of interest for nonlinear superconducting circuit elements, which have many applications such as in solid-state qubit readout and coupling. Many different mechanisms can give rise to Josephson diode effects (JDEs). In this work, we investigate JDEs generated by the self-field of the supercurrent in the junction. To this end, we experimentally investigate JDEs in the supercurrent quantum interference patterns of planar hybrid Josephson junctions, composed of a cadmium arsenide thin film interfaced with a conventional superconductor. A model that includes the supercurrent self-field accurately describes the experimental observations. We show that self-field-induced JDEs are generally expected in planar junctions in perpendicular magnetic fields, even in cases of symmetric and uniform junctions, as long as they exhibit sufficiently large critical currents. Here, we discuss the tunability of self-field-induced JDEs via the supercurrent density and other parameters.

Josephson diode

Atomic-scale frustrated Josephson coupling and multicondensate visualization in FeSe

In a Josephson junction involving multiband superconductors, competition between interband and interjunction Josephson couplings gives rise to frustration and spatial disjunction of superfluid densities among superconducting condensates. Such frustrated coupling manifests as the quantum interference of Josephson currents from different tunnelling channels and becomes tunable if channel transparency can be varied. To explore these unconventional effects in the prototypical s ± -wave superconductor FeSe, we use atomic-resolution scanned Josephson tunnelling microscopy for condensate-resolved imaging and junction tuning—capabilities unattainable in macroscopic Josephson devices with fixed characteristics. We quantitatively demonstrate frustrated Josephson tunnelling by examining two tunnelling inequalities. The relative transparency of two parallel tunnelling pathways is found tunable, revealing a tendency towards a 0–π transition with decreasing scanned Josephson tunnelling microscopy junction resistance. Here, the simultaneous visualization of both superconducting condensates reveals anticorrelated superfluid modulations, highlighting the role of interband scattering. Our study establishes scanned Josephson tunnelling microscopy as a powerful tool enabling new research frontiers of multicondensate superconductivity.

Scanning probe microscopy

Momentum space AC Josephson effect and intervalley coherence in multilayer graphene

Electron transport driven by the phase coherence and interference of quantum many-body wavefunctions is a fascinating phenomenon with potential technological significance. Superconductivity, for example, enables dissipationless transport through macroscopic phase twisting, while charge-density waves show broadband noise and AC-DC interference once their phase is depinned. We identify an analogous phase-coherent dynamics in the intervalley-coherent (IVC) state frequently observed in rhombohedral multilayer graphene. We show that a static magnetic field drives an oscillating intervalley current, which produces an oscillating orbital magnetization and thereby a detectable AC Hall response. This mechanism is similar to the Josephson effect observed in superconductors but now happening in momentum space. In this analogy, the static magnetic field acts as the DC voltage, while the oscillating intervalley current is the AC Josephson current. We provide microscopic calculations of all the phase-number free-energy parameters in rhombohedral trilayer graphene, establishing this effect as an experimental signature of IVC order.

electronic properties and materials

Unconventional polaronic ground state in superconducting LiTi 2 O 4

Geometrically frustrated lattices can display a range of correlated phenomena, ranging from spin frustration and charge order to dispersionless flat bands due to quantum interference. One particularly compelling family of such materials is the half-valence spinel LiB 2 O 4 materials. On the B-site frustrated pyrochlore sublattice, the interplay of correlated metallic behavior and charge frustration leads to a superconducting state in LiTi 2 O 4 and heavy fermion behavior in LiV 2 O 4 . To date, however, LiTi 2 O 4 has primarily been understood as a conventional BCS superconductor despite a lattice structure that could host more exotic ground states. Here, we present a multimodal investigation of LiTi 2 O 4 , combining ARPES, RIXS, proximate magnetic probes, and ab-initio many-body theoretical calculations. Our data reveals a novel mobile polaronic ground state with spectroscopic signatures that underlie co-dominant electron-phonon coupling and electron-electron correlations also found in the lightly doped cuprates. The cooperation between the two interaction scales distinguishes LiTi 2 O 4 from other superconducting titanates, suggesting an unconventional origin to superconductivity in LiTi 2 O 4 . Our work deepens our understanding of the rare interplay of electron-electron correlations and electron-phonon coupling in unconventional superconducting systems. In particular, our work identifies the geometrically frustrated, mixed-valence spinel family as an under-explored platform for discovering unconventional, correlated ground states.

36 MATERIALS SCIENCE