Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Plasma Wake Downstream of Lunar Topographic Obstacles: Preliminary Results from 2D Particle Simulations

Anticipating the plasma and electrical environments in permanently shadowed regions (PSRs) of the moon is critical in understanding local processes of space weathering, surface charging, surface chemistry, volatile production and trapping, exo-ion sputtering, and charged dust transport. In the present study, we have employed the open-source XOOPIC code [I] to investigate the effects of solar wind conditions and plasma-surface interactions on the electrical environment in PSRs through fully two-dimensional pattic1e-in-cell simulations. By direct analogy with current understanding of the global lunar wake (e.g., references) deep, near-terminator, shadowed craters are expected to produce plasma "mini-wakes" just leeward of the crater wall. The present results (e.g., Figure I) are in agreement with previous claims that hot electrons rush into the crater void ahead of the heavier ions, fanning a negative cloud of charge. Charge separation along the initial plasma-vacuum interface gives rise to an ambipolar electric field that subsequently accelerates ions into the void. However, the situation is complicated by the presence of the dynamic lunar surface, which develops an electric potential in response to local plasma currents (e.g., Figure Ia). In some regimes, wake structure is clearly affected by the presence of the charged crater floor as it seeks to achieve current balance (i.e. zero net current to the surface).

Zimmerman, Michael I.↗

Electric Field’s Dueling Effects through Dehydration and Ion Separation in Driving NaCl Nucleation at Charged Nanoconfined Interfaces

Investigating nucleation in charged nanoconfined environments under electric fields is crucial for many scientific and engineering applications. Here we study the nucleation of NaCl from aqueous solution near charged surfaces using machine-learning-augmented enhanced sampling molecular dynamics simulations. Our simulations successfully drive phase transitions between the liquid and solid phases of NaCl. The solid phase is stabilized under electric fields, particularly at an intermediate surface charge density. We examine which physical characteristics drive the nucleation of NaCl from aqueous solutions and find that the removal of solvent water from Cl– at the solid precursor surface plays a more critical role than the accumulation of ions. Our simulations reveal the competing effects of electric fields on nucleation processes: they facilitate the removal of water, promoting nucleation, but also promote the separation of ion pairs, thereby hindering nucleation. Here, this work provides a framework for studying nucleation processes in nanoconfined environments under electric fields and provides physical insights for the design of electrochemistry materials.

Electric fields↗

Sustainable lead management in halide perovskite solar cells

Despite the rapid development of perovskite solar cells (PSCs) toward commercialization, the toxic lead (Pb) ions in PSCs pose a potential threat to the environment, health and safety. Managing Pb via recycling represents a promising approach to mitigating its toxicity. However, managing Pb from commonly used organic solvents has been challenging due to the lack of suitable Pb adsorbents. Here, we report a new adsorbent for both separation and recovery of Pb from PSC pollutants. The synthesized iron-incorporated hydroxyapatite possesses a strongly negatively charged surface that improves electrostatic interaction through surface-charge delocalization, thus leading to enhanced Pb adsorption. Finally, we demonstrate the feasibility of a complete Pb management process, including the purification of Pb-containing non-aqueous solvents below 15 parts per 10 9 , a level compliant with the standards of the US Environmental Protection Agency, as well as recycling of 99.97% of Pb ions by forming lead iodide.

14 SOLAR ENERGY↗

NASA Charging Analyzer Program - A computer tool that can evaluate electrostatic contamination

The data from the ATS-5 and -6 Auroral Particles Experiments have shown that the environment at geosynchronous orbit can charge spacecraft surfaces to appreciable negative values. Such surface charges could have undesirable effects on satellite equipment and the data obtained in satellite experiments. A computer program, the NASA Charging Analyzer Program (NASCAP), has, in this connection, been developed to determine the surface charging of spacecraft when encountering geomagnetic substorm conditions. Once a model of a spacecraft has been developed in the NASCAP code, the surface charging can be computed for any environmental input flux. On the basis of the obtained information regarding the surface charging, charged particle trajectories can be computed to determine if it is possible for a particle to return to a satellite surface. It is pointed out that the computer runs conducted with the NASCAP code represent the first attempts to use a self-consistent program to study the behavior of spacecraft surfaces experiencing a geomagnetic substorm condition.

Stevens, N. J.↗

An Investigation of Low Earth Orbit Internal Charging

Low Earth orbit is usually considered a relatively benign environment for internal charging threats due to the low flux of penetrating electrons with energies of a few MeV that are encountered over an orbit. There are configurations, however, where insulators and ungrounded conductors used on the outside of a spacecraft hull may charge when exposed to much lower energy electrons of some 100's keV in a process that is better characterized as internal charging than surface charging. For example, the minimal radiation shielding afforded by thin thermal control materials such as metalized polymer sheets (e.g., aluminized Kapton or Mylar) and multilayer insulation may allow electrons of 100's of keV to charge underlying materials. Yet these same thermal control materials protect the underlying insulators and ungrounded conductors from surface charging currents due to electrons and ions at energies less than a few keV as well as suppress the photoemission, secondary electron, and backscattered electron processes associated with surface charging. We investigate the conditions required for this low Earth orbit "internal charging" to occur and evaluate the environments for which the process may be a threat to spacecraft. First, we describe a simple one-dimensional internal charging model that is used to compute the charge accumulation on materials under thin shielding. Only the electron flux that penetrates exposed surface shielding material is considered and we treat the charge balance in underlying insulation as a parallel plate capacitor accumulating charge from the penetrating electron flux and losing charge due to conduction to a ground plane. Charge dissipation due to conduction can be neglected to consider the effects of charging an ungrounded conductor. In both cases, the potential and electric field is computed as a function of time. An additional charge loss process is introduced due to an electrostatic discharge current when the electric field reaches a prescribed breakdown strength. For simplicity, the amount of charge lost in the discharge is treated as a random percentage of the total charge between a set maximum and minimum amount so a user can consider partial discharges of insulating materials (small loss of charge) or arcing from a conductor (large loss of charge). We apply the model to electron flux measurements from the NOAA-19 spacecraft to demonstrate that charging can reach levels where electrostatic discharges occur and estimate the magnitude of the discharge.

NeergaardParker, Linda↗

Humidity-Dependent Electrostatic Charge Decay on Dielectric Surface in Enclosed Volumes

Electrostatic surface charge decay is investigated to determine loss mechanisms, the effect of humidity, enclosure size, and material. This work focuses on charging dielectric and metal surfaces close to the electrical breakdown threshold in atmospheric air under humid and dry conditions. After initial charging to a maximum potential of roughly 30 kV, the associated surface charge is allowed to decay because of recombining with ions from the natural background, resulting in decay times ranging from minutes to hours to days. Spheres with a radius of 50 mm consisting of varying materials (PTFE and metal as referenced later) are charged and tested at relative humidity levels, RH, of 10%, 35%, and 64%. It was found that the ion-ion pair production rate and the enclosure size affected the measured charge decay rate. The impact of air convection on charge decay in the open air (no enclosure) is discussed. The humidity increased the rate of charge decay on the metal and dielectric spheres. For example, in the first 25 minutes after charging, the total charge on the PTFE sphere decreased to 66%or 50% from its initial value in the 10% and 35% RH tests, respectively. An equivalent generation rate is found for the ions in the enclosure, with 10 and 24 ion pairs cm −3 s −1 being generated at a 5% and 49% relative humidity, respectively.

42 ENGINEERING↗

The Influence of Particle Charge on Heterogeneous Reaction Rate Coefficients

The effects of particle charge on heterogeneous reaction rates are presented. Many atmospheric particles, whether liquid or solid are charged. This surface charge causes a redistribution of charge within a liquid particle and as a consequence a perturbation in the gaseous uptake coefficient. The amount of perturbation is proportional to the external potential and the square of the ratio of debye length in the liquid to the particle radius. Previous modeling has shown how surface charge affects the uptake coefficient of charged aerosols. This effect is now included in the heterogeneous reaction rate of an aerosol ensemble. Extension of this analysis to ice particles will be discussed and examples presented.

Aikin, A. C.↗

Thunderstorm and Fair-weather Quasi-Static Electric Fields Over Land and Ocean

Natural lightning and the associated clouds are known to behave differently over land and ocean, but many questions remain. We expand the related observational datasets by obtaining simultaneous quasi-static electric field observations over coastal land, near-shore water, and deep ocean regions during both fair-weather and thunderstorm periods. Oceanic observations were obtained using two 3-m NOAA buoys that were instrumented with Campbell Scientific electric field mills to measure the quasi-static electric fields. These data were compared to selected electric field records from the existing on-shore electric field mill suite of 31 sensors at Kennedy Space Center (KSC). Lightning occurrence times, locations and peak current estimates for both onshore and ocean were provided by the U.S. National Lightning Detection Network. The buoy instruments were first evaluated on-shore at the Florida coast, and the first system was calibrated for field enhancements and to confirm proper behavior of the system in elevated-field environments. The buoys were then moored 20 mi and 120 mi off the coast of KSC in February (20 mi) and August (120 mi) 2014. Diurnal fair-weather fields at both ocean sites matched will with each other and with those found during the Carnegie cruise, but mean values were 33% smaller, due at least in-part to constraints on the calibration procedure. Diurnal fair-weather fields variations at coastal and inland sites were a poorer match than offshore, likely because the offshore environment is “cleaner” with limited variations in local space charge, lower surface aerosol densities, little surface heating to disturb the surface charge layer during fair weather, and fewer local radioactive sources to modulate the near-surface electrical conductivity. Storm-related static fields were 4-5× larger at both oceanic sites than over land, likely due to decreased screening by near-surface space charge produced by corona current. The time-evolution of the electric field and field changes during storm approach are sufficiently different over land and ocean to warrant further study. This work shows the quality, accuracy, and reliability of these data, and has demonstrated the practicality of off-shore electric field measurements for safety- and launch-related decision making at KSC.

Lightning↗

Simulation of Charge Collection to Spacecraft Surfaces: Freja Satellite

As spacecraft travel through plasma, spacecraft surfaces become charged by the collection of charged particles. This process is referred to as Surface Charging. These charges can be detrimental to the vehicle's electronic subsystems as they present a threat of electrostatic discharge (ESD) to onboard circuitry. The process of Surface Charging is complex and is affected by many elements. The charging of each surface is unique. The potential of an individual surface is dependent upon many variables including but not limited to the surface's geometry, material and its location. Each surface also has unique interactions with the surrounding plasma. Other factors that play large roles in the charging process is the density and temperature of plasma ions and electrons. Using Nascap-2k, a model of the Freja satellite has been constructed, and its auroral plasma environment has been imitated to simulate surface charging characteristics. The charging process of the Freja satellite has been modeled iteratively with incremental changes in both the Maxwellian electron temperature (eV) as well as the Gaussian electron energy (eV). This study provides an analysis of the sensitivity between spacecraft surface charging and these two primary variables of electron differential flux.

Wolfley, Olivia H.↗

Simulation of Charge Collection to Spacecraft Surfaces: Freja Satellite

As spacecraft travel through space plasma, spacecraft surfaces become charged by the collection of charged particles. This process is referred to as Surface Charging. These charges can be detrimental to the vehicle's electronic subsystems as they present a threat of electrostatic discharge (ESD) to onboard circuitry. The process of Surface Charging is complex and is affected by many elements. The charging of each surface is unique. The potential of an individual surface is dependent upon many variables including but not limited to the surface's geometry, material and its location. Each surface also has unique interactions with the surrounding plasma. Other factors that play large roles in the charging process is the density and temperature of plasma ions and electrons. Using Nascap-2k, a model of the Freja satellite has been constructed, and its auroral plasma environment has been imitated to simulate surface charging characteristics. The charging process of the Freja satellite has been modeled iteratively with incremental changes in both the Maxwellian electron temperature (eV) as well as the Gaussian electron energy (eV). This study provides an analysis of the sensitivity between spacecraft surface charging and these two primary variables of electron differential flux.

Wolfley, Olivia Hope↗

Controlling protein adsorption modes electrostatically

Protein adsorption on surfaces is ubiquitous in biology and in biotechnology. There are various forces required for controlling protein adsorption. Here, we introduce an explicit ion coarse-grained molecular dynamics simulation approach for studying the effects of electrostatics on protein adsorption, and 2D protein assembly on charged surfaces. Our model accounts for the spatial distribution of protein charges. We use catalase as our model protein. We find that the preferential adsorption mode of proteins at low protein concentration on a charged surface is “standing up”. When the protein concentration in a solution increases to reach a critical density on the surface, the adsorption mode switches from “standing up” to a mixed state “flat on” and “standing up”, which increases the lateral correlations among the adsorbed proteins. As such, the changes in the adsorption mode arise from the protein adsorption that cancel the surface charge and the protein–protein repulsion. This correlated surface structure melts as the salt concentration increases because the charged surface is cancelled by the salt ions and the proteins de-adsorb. For the case of strongly charged surfaces the “standing up” conformation remains more favorable even at high protein adsorption at low salt concentrations since in that conformation the surface charge is cancelled more effectively, generating an even more laterally correlated structure. We elucidate the effects of parameters such as surface charge density, salt concentration, and protein charges on the different adsorption modes and the structure and organization of proteins on the charged surfaces. Finally, this study provides a guide for controlling protein assembly on surfaces.

59 BASIC BIOLOGICAL SCIENCES↗

The electrokinetic behavior of calcium oxalate monohydrate in macromolecular solutions

Electrophoretic mobilities were measured for calcium oxalate monohydrate (COM) in solutions containing macromolecules. Two mucopolysaccharides (sodium heparin and chrondroitin sulfate) and two proteins (positively charged lysozyme and negatively charged bovine serum albumin) were studied as adsorbates. The effects of pH, calcium oxalate surface charge (varied by calcium or oxalate ion activity), and citrate concentration were investigated. All four macromolecules showed evidence for chemical adsorption. The macromolecule concentrations needed for reversing the surface charge indicated that the mucopopolysacchrides have greater affinity for the COM surface than the proteins. The amount of proteins that can chemically adsorb appears to be limited to approximately one monomolecular layer. When the surface charge is high, an insufficient number of proteins can chemically adsorb to neutralize or reverse the surface charge. The remaining surface charge is balanced by proteins held near the surface by longer range electrostatic forces only. Citrate ions at high concentrations appear to compete effectively with the negative protein for surface sites but show no evidence for competing with the positively charged protein.

Curreri, P. A.↗

Electrical Responses of Modified Mineral Surfaces as Observed With Spectral Induced Polarization and Atomic Force Microscopy

Abstract Atomic force microscopy (AFM) and spectral induced polarization (SIP) are widely used to investigate the electrical properties of mineral surfaces at vastly different scales of measurement. We compare AFM and SIP measurements made on two different materials (glass beads and silica gel) subjected to etching, deposition of iron oxide particles, and inclusion of calcite grains. We found that the treatments produced qualitatively consistent behaviors in the AFM and SIP data. Direct AFM measurements of surface charge density for silica and calcite surfaces were quantitatively compared to values estimated from the SIP results using a grain polarization model. No statistically significant difference (at a 95% confidence level) was found between the surface charge density of silica estimated by AFM (2.3 ± 6.6 mC/m 2 for glass beads and 1.6 ± 0.1 mC/m 2 for silica gel) versus SIP (5.4 ± 4.4 mC/m 2 for glass beads and 1.6 ± 0.5 mC/m 2 for silica gel). The surface charge density for calcite determined by AFM (43.5 ± 12.9 mC/m 2 ) was approximately 19 times higher than that found for silica. While the charge density of calcite surfaces determined by SIP was also generally higher than that found for silica, different treatments produced significantly different values between 4.7 and 258 mC/m 2 (with a maximum 95% CI of ±8.7 mC/m 2 ). Several possible explanations exist for the range of the observed SIP measurements, including aging of the calcite surfaces. Overall, this study suggests the potential for the complementary use of AFM and SIP measurements to constrain future investigations of polarization mechanisms in porous media.

Geochemistry & Geophysics↗

Modeling salt adsorption in electrical double layer for capacitive deionization

Abstract This work presents an electrical double layer (EDL) model for capacitive deionization (CDI) by intercorrelating the salt adsorption, the electrode voltage, and the surface charge density. The counterion condensation is considered a crucial contribution to salt adsorption because of the high surface charge density in the charged micropores. The counterions condense when the surface charge density exceeds a critical value, which is predicted by the counterion condensation theory. The EDL model accurately correlates the NaCl salt adsorption and electrode voltage with various surface charge densities and well predicts the salt adsorption in a wide range of external salt concentrations. The EDL model reproduces the non‐monotonic relationship between the salt adsorption and the specific surface area observed in experiments and provides an explanation from the modeling perspective. Exhibiting superior accuracy and predictability for salt adsorption, the EDL model could serve as an enabling tool contributing to the development of CDI processes.

Lin, Yu‐Jeng↗

Electrokinetic comparison of CaF 2 and AgCl from a MDS perspective

CaF 2 has limited electrokinetic sensitivity to fluoride ions in solution and the positive CaF 2 surface charge is not reversed at high fluoride ion concentration. Similar insensitivity of surface charge to high fluoride ion concentration has been observed for other alkali and alkaline earth fluoride salts. On the contrary, chloride ions act as potential determining ions for AgCl and reverse the surface charge, as expected. FTIR-IRS results indicate that the AgCl/water interface has a water structure-breaking tendency, whereas the CaF 2 /water interface has a structure-making tendency. Here, it is speculated that the strong hydrogen bonding between fluoride ions and water prevents the accommodation of excess fluoride ions at surface lattice sites of fluorite, and therefore explains the low sensitivity of the fluorite surface charge sign and magnitude to fluoride ion concentration. However, this speculation has not been examined at the molecular level and is evaluated by molecular dynamics simulations (MDS) in the research presented in this paper. Higher hydrogen bond density at the CaF 2 mineral/water interface confirms that the water structure has stronger hydrogen bonding at both the CaF 2 mineral surface and with the F - ion in solution. In this way, the interaction of the F - ion with the CaF 2 surface is inhibited.

36 MATERIALS SCIENCE↗

Atomistic Insight into Cation Effects on Binding Energies in Cu-Catalyzed Carbon Dioxide Reduction

Electrolyte properties in general and electrolyte ions in particular have been shown to have significant effects on the kinetics of electrochemical CO 2 and CO reduction at metal electrodes, but these effects have not yet been fully understood. Here, we investigate the effects of cations at the aqueous electrolyte–Cu(211) interface on adsorbate binding energies and the electrolyte structure using density functional theory (DFT). Charging the interface via explicit Na + has systematic effects on adsorbate–electrolyte interactions and conformations. We describe specific local adsorbate–ion interactions, including direct alkali ion–adsorbate coordination and hydrogen bonding via ion-coordinated water molecules. The relative importance of these specific interactions and purely electrostatic field–adsorbate interactions is investigated by comparing the DFT-calculated ion effects to those predicted by purely electrostatic models of the interface and the adsorbates. We find that the trend in ion effects among different adsorbates at constant surface charge density is well explained by a purely electrostatic interaction model. The binding energy of OCCHO is found to depend strongly on the surface charge density as well as the spatial distribution of ions at constant surface charge density. These effects are also explained by a purely electrostatic local electrostatic field–adsorbate model. This indicates that alkali ion effects can be mainly attributed to purely electrostatic field interactions and that the local field at ion-stabilized active sites can depend significantly on both the overall charge density and on the spatial distribution of ions at constant charge density. This work provides new insight on alkali ion effects on a variety of adsorbates relevant to the CO 2 and CO reduction reactions by describing specific local ion–adsorbate interactions, systematic changes in adsorbate–electrolyte interactions induced by explicit surface charge, and comparisons of the calculated effects on binding energies to simple electrostatic field–adsorbate models to explain trends among various adsorbates and at varying surface charge densities and supercell configurations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Steady-State Solution of a Solar Wind-Generated Electron Cloud in a Lunar Crater

We formulate an analytic description of a steady-state electron cloud and affiliated surface charge, formed in the plasma wake generated as the solar wind flows horizontally over a lunar crater. The solution is complementary to the well-known self-similar plasma expansion formulation, which breaksdown at the plasma wake front and thus fails to capture a substantial region of the crater interior. The present model establishes a theoretical basis for existing simulation results, which suggest that the cavity formed below the wake front is populated mainly by electrons, resulting in a substantial negative surface charge. The electrostatic potential throughout this subwake region is determined by solving Poisson'sequation for a Maxwellian electron cloud, bounded above by the self-similar plasma expansion front and below by the electrostatically charged surface.

Rhodes, Dov J.↗

MECA/Electrometer

The commercially available electrometers are typically used to survey for ESD (Electrostatic Discharge) prone materials in electronic component assembly areas. These instruments operate using either DC (direct current) or AC (alternating current). This description is concerned with a DC electrometer. The critical components are the detecting electrode, the input capacitance, operation amplifier (op amp), a shorting switch used to zero the instrument, and the charged surface. DC Instruments are used to measure the change in charge placed in front of the instruments detecting electrode after instrument is zeroed. These instruments -have the feature that the input voltage will drift with time. This drift is typically hours in duration and depends on the op amp input current. The conventional ESD survey instrument. During a measurement, the conventional electrometer is held at a known distance from a charged surface. The now DC electrometer, is used in a different manner than ESD survey instrument. In the new instrument, triboelectric materials are placed in contact with the surface to be measured, rubbed against the surface, removed from the surface, and the triboelectrically-induced charge measured. Thus, the distance between the charged surface and the detecting electrode is a known distance leading to a direct measure of the electric field and deposited charge.

Buehler, Martin↗