Search NASA⌕ Search

SEARCH · Search NASA

Results for “surveillance systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Proper use of HHDRIFT in surveillance and production conditions

With higher quality optics, newer benchtop DRIFT (diffuse reflectance infrared Fourier transform) spectroscopy systems with modern electronic circuitries should be the preferred choice if detection sensitivity, intensity, and reliability are top priorities. However, when space consideration or other restrictions require the use of a HHDRIFT (handheld DRIFT), it is possible to convert the measurements of the HHDRIFT to those obtained from any benchtop DRIFT and vice versa. In this report, the conversion of the measurements between a HHDRIFT and a benchtop DRIFT at LLNL (Lawrence Livermore National Laboratory) are shown to be linear in both production and surveillance conditions. A similar methodology can be used to obtain the measurement correlations between any HHDRIFT and any benchtop DRIFT at other sites.

36 MATERIALS SCIENCE↗

14 Steps to Creating Value in Cost and Schedule Resources for Nuclear Waste Management - 20188

While Waste Management budgets are shrinking, DOE required cost and schedule controls are becoming increasingly stringent. At the same time, there is a scarcity of adept, qualified, and competent projects controls staff who both understand nuclear waste management and are capable of addressing today's cost and schedule challenges. In response, we have developed a systematic approach to training and mentoring project controls staff. The approach is based on the observations and lessons learned on projects, both successful and unsuccessful, over the past 20 years. During that time, we evaluated staff development and used that experience to design a program that progresses the maturity, knowledge and experience of the individual. The program is based on the unique needs of cost and schedule specialists while incorporating the best leadership and managerial applications. The system is not limited to developing individual software skills, which is a primary focus of many project controls training programs. Instead, our system develops an individual's soft and hard skill sets. The system develops the user's skill, talent, attitude, and drive to do the best job possible. It focuses on all aspects of becoming a more productive technical team while accepting responsibility for individual growth. It also enhances the project controls team by setting up checks and balances that everyone is aware of and participates in. The system is based on 14 steps of increasing complexity in knowledge and application. The system clarifies roles, responsibilities and expectations. It helps eliminate uncertainty and reduces stress on staff and managers. It contains everyday routine actions and is simple to implement. It allows the development of a consistent rhythm to staff growth and development. Mastering the steps will allow the user to achieve excellence in cost and schedule control. The 14 steps are: 1 - Key Performance Objectives, 2 - Check Lists, 3 - Desktop Guides, 4 - System Description, 5 - Procedures, 6 - Software and On the Job Training (OTJ), 7 - Traceability Checks, 8 - Surveillances, 9 - 32 Criteria, 10 - The Contract, 11 - Customer/Government Guidance, 12 - Training and Mentoring Others, 13 - Master your weekly and daily schedules, 14 - Improving your interpersonal skills. Application and mastery of this system will produce better cost and schedule control results. Your project controls staff will write better reports, analyze data better, make better use of their time, and be more valuable to decision makers. If followed rigorously, our system will produce a great project controls team, which is invaluable to the success of each project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guide for Joint Participation in a DOE Complex Wide SAVY-4000 Surveillance Program

This document describes LANL Storage Program best practices when working with other User Sites to implement DOE M441.1-1 Manual requirements through the use of the SAVY nuclear material packaging system. It is a Manual directive for Field Element Managers to review and approve the SAVY-4000 container series design (with supporting technical basis) as a packaging system for use at their respective sites. This review and approval incorporates an evaluation of the User Site methodology for SAVY surveillance and the process for documenting its nuclear materials storage program. This document aims to assist the Field Element Mangers and User Sites in the processes necessary to credit LANL SAVY surveillance for key elements of the User Site surveillance plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated Pest Management (IPM) for Early Detection Algal Crop Protection. Final Report

During large-scale, outdoor algal biomass growth, production strain(s) are subject to attack by pathogens, predators, and non-productive competitors, compromising the biomass yield. The project team at UCSD developed and demonstrated the effectiveness of Volatile Organic Compound, VOC, analysis via mass spectrometry (MS) as an early detection system for the presence of production algal ponds infection. The MS detection can then trigger high-resolution melt analysis (HRMA) and enhanced quantitative PCR (qPCR) to identify predatory or pathogenic species precisely. This study gathered the foundational data informing how wholly automated systems monitor the health of production ponds. By detecting the presence of low molecular weight VOCs in the air space above ponds, the instrument was able to mimic “sniffing” the health of the algae pond. This early warning system will be free growers from time-consuming and costly regular surveillance of ponds with the current techniques, such as qPCR and flow-cam assays, which are slower, less sensitive, and not easily fully automated, resulting in increased production efficiency through the reduction of crop loss. This project demonstrated that Chemical Ionization Mass Spectrometry, CIMS, could serve as a real-time monitor of ponds health tracking up to 100 different VOCs simultaneously for continuous periods up to 60 days without interruption, signaling infection within an algal crop 24 to 36 hours prior to techniques such as qPCR and microscopy. While mass spectrometry is an expensive tool, this simple VOC sampling system proved not only to be sensitive and robust but could to multiplexed to monitor several ponds, lowering the overall cost serially. This technology demonstrated a reduction in biomass production cost by approximately 50% compared to growers not employing any detection methodology.

09 BIOMASS FUELS↗

Wide Area 3D Measurement System for Analysis of 3013 Inner Container Closure Weld Region

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR, a laser confocal microscope (LCM) is used to perform close visual examination of the surface and to measure corrosion features on the surface. However, in FY20, the introduction of the Wide Area 3D Measurement System (WAMS) was tested as a method for faster inspection of the ICCWR. Optimization of the WAMS parameters for data collection was carried out using a generic tear-drop type sample containing large and fine Stress Corrosion Cracking (SCC) fractures and high resolution images were compared to the image obtained with the LCM. Although the image with the LCM shows higher resolution than the WAMS images, the small features can be still identified in the WAMS images. The advantage of collecting data for the full circumference using the WAMS is that it can take about a week to complete, which represents 1/16 of the time needed with the LCM. Nonetheless, both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS can be utilized to obtain images for faster screening or identification of corrosion features on the surface while the LCM can be utilized to obtain higher resolution images of those areas identified by the WAMS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of Margin-Based Methods to Assess System Health

Health management of complex systems such as nuclear power plants is an essential task to guarantee system reliability. This task can be greatly enhanced by constantly monitoring asset status and performances and process such data (through anomaly detection, diagnostic, and prognostic computational algorithms) to identify asset degradation trends and faulty states. While such information and data are typically available for many of the assets, they are not propagated from the asset to the system level in order to identify the most critical assets and prioritize maintenance and surveillance activities. The main reason is driven by the fact that current reliability modeling techniques are inadequate to process such information/data. This is due to the nature of these techniques which are based on the concept of failure rate/probability that do not serve an operational context where quantitative asset health information is available. Simply stated, current reliability techniques serve a run-to-failure operational setting and not a predictive maintenance one where the goal is to perform maintenance and surveillance activities only when they are needed based on asset health. The risk informed asset management (RIAM) project is focusing on the development of a different kind of reliability modeling techniques designed to adequately serve a predictive operational setting. Such reliability techniques move aways from a failure rate/probability to a margin-based mindset where margin is here used as a metric to quantify asset health based only on current and past operational experience of the asset under consideration. In addition, margin-based reliability techniques are able to propagate asset health information from the component to system level and provide importance measure to each asset. This report summarizes a recent activity performed in collaboration with plant modernization pathway designed to integrate monitoring data into margin-based reliability models. Such activity focuses on a specific system of an existing nuclear power plant where large amount of historic monitoring data is used to monitor asset and system health.

97 MATHEMATICS AND COMPUTING↗

Technical Performance and Cost Optimization of Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) for Wide-area Surveillance and Identification of Marine Life at Marine Energy Installations

Florida Atlantic University developed an underwater optical monitoring system prototype - Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) - suitable for marine energy full project lifecycle observation (baseline, commissioning, and decommissioning), with an automated real-time classification of marine animals. With precursor 2014 DOE funding (award DE-EE0006787), a prototype UMSLI was demonstrated in a controlled laboratory environment and achieved a TRL 6. This EERE DE-EE0007828 award aimed to both increase the TRL of the UMSLI by improving the technology performance (e.g., increase distance of marine animal target detection capability, add additional species classification capabilities, improve the system performance during the day, etc.) and reduce the cost. The UMSLI presents a novel application of underwater distributed Light Detection And Ranging (LiDAR), an advanced remote sensing method that uses light in the form of laser pulses for an application, this paired with an algorithm provides 360 degrees underwater detection, imaging, and classification of marine life. This solution for underwater monitoring of biota preserves the advantages of traditional optical and acoustic solutions while overcoming many associated disadvantages for marine energy site environmental monitoring, such as difficulties in species detection and classification in low light or night and turbid environments. This new approach is a purposefully designed, reconfigurable adaptation of an existing class 3B laser technology into one UMSLI instrument that can be easily mounted on or around different classes of marine energy equipment, such as devices to capture ocean current energy or wave energy. The system uses relatively low average power, utilizes far-red (> 635nm) laser illumination to be invisible and eye-safe to marine animals, is compact, and cost-effective. The equipment is designed for long-term, maintenance-free operations (i.e., current design is targeting more than 7 days continuous operation), to inherently generate a sparse primary dataset that only includes detected anomalies, and to allow robust real-time automated animal classification and identification with a low data bandwidth requirement. The technology’s overarching goal for application, is a system that can be deployed to collect pre-installation baseline species observations at a proposed marine energy deployment site with minimal post-processing overhead. The envisioned system will also produce high-resolution imagery of marine animals through a wide range of conditions and support automated tracking and notification of the presence of managed animals within established perimeters of marine energy equipment to satisfy deployed marine energy projects’ endangered and threatened species monitoring requirements. Through the current project, we demonstrated the UMSLI prototype in an operational environment and increased the UMSLI’s Technology Readiness Level from 6 to 7. The project resulted in many novel technologies, including: 1) an eye-safe red laser based, low-cost LiDAR system that can detect targets up to 10 meters distance; 2) the GAN-based machine learning underwater LiDAR image enhancement technique (this is the first known application of GAN technique in underwater LiDAR); 3) LiDAR-based real-time automated detection capabilities; and 4) a template matching based automated classification tool. These technologies build a solid foundation for future efforts to develop an extended range electro-optical monitoring system suitable for marine energy deployments. In addition to technology development, a key lesson learned is that addressing regulatory and safety requirements must be front and center in any marine energy monitoring applications.

16 TIDAL AND WAVE POWER↗

A Novel N Staging System for Predicting Survival in Patients with Medullary Thyroid Cancer

Introduction: Despite the crucially prognostic value of lymph node metastasis (LNM) in patients with medullary thyroid cancer (MTC), only the LNM compartment alone was reflected in the 8th edition of the American Joint Committee on Cancer (AJCC) system. Objective: This study aimed to incorporate the metastatic lymph node number and metastatic lymph node ratio to generate a more accurate and appropriate N staging system for patients with MTC based on recursive partitioning analysis. Design, Setting, and Patients: Two cohorts were included in the analysis, including 1374 MTC patients from the Surveillance, Epidemiology, and End Results database as the derivation cohort, and 164 patients from Fudan University Shanghai Cancer Center as the validation cohort. The predictive performance of the alternative proposed N staging system was compared with that of the 8th AJCC system by using the Harrell concordance index (C-index) and the area under the receiver operating characteristic curve (AUC). Results: In the derivation cohort, the C-index and the AUC at 10 years were 0.778 and 0.789, respectively, for the novel N staging system, and 0.749 and 0.741, respectively, for the 8th AJCC N staging system. Similar trends were also observed in the validation cohort. The proposed N staging system had a better prognostic performance. Conclusion: With some improvements, the novel N staging system for MTC suggested from this research may be assessed for potential adoption in the next edition of the AJCC N staging system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Stage N3 of the Eighth Edition AJCC Staging System for Nasopharyngeal Carcinoma

Objectives To validate stage nodal (N)3 of the 8th edition American Joint Committee on Cancer (AJCC) staging system for nasopharyngeal carcinoma (NPC). Methods This retrospective cohort study extracted NPC patients from the Surveillance, Epidemiology, and End Results database between 2004 and 2016. Pathologically confirmed patients with complete data of level IV, N3a, and N3b lymph node metastasis were investigated. The included patients were divided into level IV, N3a, and N3b groups. Five‐year overall survival (OS) and cancer‐specific survival (CSS) were compared among the three groups. Results A total of 693 patients were included: 285 (41.13%) patients in the level IV group, 124 (17.89%) patients in the N3a group, and 284 (40.98%) patients in the N3b group. The 5‐year OS (57.1%, 55.0%, and 55.2%) and CSS (64.4%, 63.5%, and 64.4%) were not different among the level IV, N3a, and N3b groups. Multivariate regression analysis revealed that N stage was not an independent prognostic factor for OS (hazard ratio [HR] = 1.03, 95% confidence interval [CI]: 0.91–1.17; P = .65) or CSS (HR = 1.03, 95% CI: 0.89–1.19; P = .70). Conclusion Stage N3 of the 8th edition AJCC staging system for NPC is reasonable. Level of Evidence III Laryngoscope , 131:535–540, 2021

Pan, Xin‐Bin↗

Remote Sensing Low Signal-to-Noise-Ratio Target Detection Enhancement

In real-time remote sensing application, frames of data are continuously flowing into the processing system. The capability of detecting objects of interest and tracking them as they move is crucial to many critical surveillance and monitoring missions. Detecting small objects using remote sensors is an ongoing, challenging problem. Since object(s) are located far away from the sensor, the target’s Signal-to-Noise-Ratio (SNR) is low. The Limit of Detection (LOD) for remote sensors is bounded by what is observable on each image frame. In this paper, we present a new method, a “Multi-frame Moving Object Detection System (MMODS)”, to detect small, low SNR objects that are beyond what a human can observe in a single video frame. This is demonstrated by using simulated data where our technology-detected objects are as small as one pixel with a targeted SNR, close to 1:1. We also demonstrate a similar improvement using live data collected with a remote camera. The MMODS technology fills a major technology gap in remote sensing surveillance applications for small target detection. Our method does not require prior knowledge about the environment, pre-labeled targets, or training data to effectively detect and track slow- and fast-moving targets, regardless of the size or the distance.

47 OTHER INSTRUMENTATION↗

Enhancing Camera Calibration for Traffic Surveillance with an Integrated Approach of Genetic Algorithm and Particle Swarm Optimization

Recent advancements in sensor technologies, coupled with signal processing and machine learning, have enabled real-time traffic control systems to effectively adapt to changing traffic conditions. Cameras, as sensors, offer a cost-effective means to determine the number, location, type, and speed of vehicles, aiding decision-making at traffic intersections. However, the effective use of cameras for traffic surveillance requires proper calibration. This paper proposes a new optimization-based method for camera calibration. In this approach, initial calibration parameters are established using the Direct Linear Transformation (DLT) method. Then, optimization algorithms are applied to further refine the calibration parameters for the correction of nonlinear lens distortions. A significant enhancement in the optimization process is achieved through the integration of the Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) into a combined Integrated GA and PSO (IGAPSO) technique. The effectiveness of this method is demonstrated through the calibration of eleven roadside cameras at three different intersections. The experimental results show that when compared to the baseline DLT method, the vehicle localization error is reduced by 22.30% with GA, 22.31% with PSO, and 25.51% with IGAPSO.

47 OTHER INSTRUMENTATION↗

Antimicrobial resistance of enteric pathogens in the Military Health System, 2009 – 2019

Abstract Background Acute diarrhea (AD) can have significant impacts on military troop readiness. Medical providers must understand current trends of enteropathogen antimicrobial resistance (AMR) in service members (SMs) to inform proper, timely treatment options. However, little is known of enteric pathogen profiles across the Military Health System (MHS). The primary objectives of this study were to identify gaps in enteric pathogen surveillance within the MHS, describe the epidemiology of AMR in enteric pathogens, and identify trends across the MHS both within the Continental United States (CONUS) and outside of the Continental United States (OCONUS). Methods Health Level 7 (HL7)-formatted laboratory data were queried for all specimens where Salmonella , Shigella , and Campylobacter species, as well as Shiga toxin-producing Escherichia coli ( E. coli ) (STEC) were isolated and certified between 1 January 2009 - 31 December 2019. Antibiotic susceptibility testing (AST) results were queried and summarized where available. Descriptive statistics were calculated for each organism by specimen source, year, and susceptibility testing availability. Results Among a total of 13,852 enteric bacterial isolates, 11,877 (86%) were submitted from CONUS locations. Out of 1479 Shigella spp. and 6755 Salmonella spp. isolates, 1221 (83%) and 5019 (74%), respectively, reported any susceptibility results through the MHS. Overall, only 15% of STEC and 4% of Campylobacter spp. specimens had AST results available. Comparing AST reporting at CONUS versus OCONUS locations, AST was reported for 1175 (83%) and 46 (78%) of Shigella isolates at CONUS and OCONUS locations, respectively, and for 4591 (76%) and 428 (63%) of Salmonella isolates at CONUS and OCONUS locations, respectively. Conclusions This study revealed inconsistent enteropathogen AST conducted across the MHS, with differing trends between CONUS and OCONUS locations. Additional work is needed to assess pathogen-specific gaps in testing and reporting to develop optimal surveillance that supports the health of the force.

Ashbaugh, Hayley↗

Antimicrobial resistance and genomic characterization of Escherichia coli from pigs and chickens in Zhejiang, China

Escherichia coli is considered an opportunistic pathogen and an indicator for antimicrobial resistance (AMR) monitoring. Despite many reports on its AMR monitoring, studies based on genome-based analysis of AMR genes are still insufficient. Here, 181 E. coli strains were isolated from anal swab samples collected from pigs and chickens of animal farms located in Eastern China and sequenced through the Illumina platform. The results showed that 87.85% (159/181) of the E. coli isolates were multidrug-resistant (MDR). Ampicillin (AMP)- spectinomycin (SPT)- tetracycline (TET)- florfenicol (FFC)- sulfisoxazole (SF)- trimethoprim/sulfamethoxazole (SXT) was the predominant AMR pattern. By whole-genome sequencing, we found that ST10 (10.49%, 19/181) and ST48 (7.18%, 13/181) were major sequence types. IncFIB and IncX1 were the most prevalent plasmid replicons. The AMR genes bla NDM-5 (1.10%, 2/181), mcr -1 (1.10%, 2/181), tet (X4) (1.10%, 2/181), and cfr (6.08%, 11/181) were also found in these isolates. In addition, among the 169 virulence genes detected, we identified ast A (37.02%, 67/181), hly A (1.66%, 3/181), hly B (1.66%, 3/181) and hly D (1.66%, 3/181), which were closely related to heat-stable enterotoxin 1 and α-hemolysin. In addition, there were 33 virulence genes associated with the iron uptake system, and 46 were adhesion-related genes. Our study highlighted the need for routine surveillance of AMR with advanced genomic approaches, providing up-to-date data on the prevalence of AMR for the development and execution of antimicrobial stewardship policy.

Zhou, Wei↗

Leveraging Environmental Monitoring Results from Department of Energy Sites for Research on the Food-Energy-Water Nexus

The Annual Site Environmental Report (ASER) from a U.S. Department of Energy (DOE) Site summarizes environmental data; environmental management performance; compliance with applicable DOE, federal, state, and local regulations; and restoration and surveillance monitoring programs. The Savannah River Site (SRS) produces ASERs that include results of monitoring mercury levels in fish samples obtained in the vicinity of SRS. Mercury is a toxic trace metal and the methylated organic form is a neurotoxin that bioaccumulates in the food web, endangering humans and other organisms. In United States, power plants are the largest source of mercury emissions. Research Objective: To determine the patterns of mercury levels in fish samples reported in the SRS environmental monitoring reports. We developed box plot visualizations to make sense of the data as well as identify fish species, dates and location with outlier mercury content. The integration and visual representation of multi-year datasets can support decision making processes on environmental compliance and environmental sustainability conducted at U.S. DOE Sites. We are constructing datasets from textual, image and multivariable data sources in the multi-year ASERs of the U.S. DOE Savannah River Site (SRS https://www.srs.gov/general/pubs/ERsum/index.html). The Fish Surveillance for mercury presents a case study for the intersection of food, energy and water systems. The dataset of 864 records (2008 and 2009) of mercury levels includes water location of fish, fish species, collection date and mercury content of fish sample. The patterns of mercury levels in the fish species as well as locations provide knowledge for further investigations. A research area for future studies is the composition of microbial communities in fish guts of varying levels of mercury.

54 ENVIRONMENTAL SCIENCES↗

Measuring 3D Profilometry of SAVY-4000 Nuclear Material Storage Containers: Novacam TubeInspect Capabilities Report

The SAVY-4000 container series is a general-purpose interim storage container for nuclear materials, developed and maintained by Los Alamos National Laboratory (LANL). It is the first vented, general-use nuclear material container to be demonstrated as meeting the requirements outlined in DOE M 441.1-1, the Nuclear Material Packaging Manual. Due to the challenging radiation, thermal, and corrosive storage conditions that the SAVY containers must endure, continuous surveillance techniques are employed to ensure the containers meet all safety standards and specifications. These inspections are typically performed by human operators, who check for issues such as corrosion, O-ring deterioration, corrosion, filter integrity, and potential manufacturing defects. However, human inspections alone are not sufficient, and automated inspection technologies, such as the ATIS system, as well as other automated systems are also utilized. The MicroCam TubeInspect, developed by Novacam Technologies Inc., is designed to address the challenges of understanding how manufacturing variations in the SAVY-4000 container series may affect performance. It is a 3D profilometry measurement system that enables detailed analysis of surface features, including defects, surface roughness, and manufacturing variations. This advanced tool significantly enhances rapid surveillance techniques for both pristine and used containers. In this study, container properties such as surface roughness, thickness, and geometric attributes like circularity are measured for SAVY-4000 containers. Artificially corroded or dented containers are examined to demonstrate the MicroCam's ability to quantify defects. A sensitivity analysis is also conducted, comparing the MicroCam results to those obtained using more precise instruments such as confocal microscopy. This comparison aims to provide valuable insights into container quality, durability, and potential improvements in manufacturing processes.

42 ENGINEERING↗

Surveillance & Detection (CRADA 567 Final Report)

This Cooperative Research and Development Agreement (CRADA) Final Report covers the work achieved by PNNL and it's commercial partner (Consolidated Resource Imaging, LLC) on video analytics for the DHS S&T Surveillance & Detection project. This project has been focused on development of the next-generation camera system (Guardian iiS) with extremely high resolution and video analytics specifically designed for crowded urban environments and congested transportation hubs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Proliferated Resilient Economical Half-Meter Aperture Space Telescopes (PREEMPT)

The PREEMPT LDRD was motivated by a major national need for better space-based imaging systems that are both high performing and affordable for the US Government. Current optical payloads for intelligence, surveillance and reconnaissance (ISR) and space domain awareness (SDA) missions can cost hundreds of millions of dollars and take years to develop, which makes it difficult to build the large constellations required for persistent, world-wide coverage. To address this, the team aimed to advance a different kind of large-aperture (>25 cm) telescope, called a monolithic telescope, in which key optical surfaces are built into a single piece of fused silica. This design greatly reduces payload and spacecraft complexity, the need for precision focus actuators, improves mechanical and thermal robustness, and lowers cost when compared with traditional Cassegrain telescopes that rely on many precisely aligned components. The project focused on five primary thrusts. The first thrust was to advance the concept of a V10, 25 cm, monolithic telescope forward from optical design to flight-ready stage. This was accomplished in partnership with Optimax, who delivered the first test unit in the early stages of the LDRD. The team developed several technologies necessary for this optic to be integrated into a flight demonstration. These include carbon fiber housings, highly detailed structural and thermal models and stress-reducing elastic averaging Hirth groove designs. These technologies resulted in a successful maturation of the optic, which is now slated to fly in late 2026/early 2027 for a demonstration mission. The second thrust was to advance the manufacturability of these optics. In collaboration with NIF’s optical manufacturing shop, we reduced polishing time from 480 hours to 65 hours through the implementation of optimized processes and new tools. The NIF team utilized a conceptual V8 (18 cm) optic to demonstrate this optimization, though it can be applied to the rest of the monolithic optic portfolio. Third, the team developed the first conceptual V20 (50 cm) payload, which is slated to be the next generation of LLNL optical payload systems. A set of structural, dynamic and thermal simulations were performed to identify potential challenges in the future development of this payload. Early-stage simulations suggest the payload is feasible, though thermal management will be the key focus area to maintain optimal performance. Fourth, a non-linear model of Viton was developed, to further enhance the reliability of our structural and dynamic models for future payloads. Viton acts as the primary interface material between the optic and its housing. Lastly, the team focused on successfully displaying the feasibility of using additively manufactured metal composites for optical space payloads. The team successfully demonstrated layer by layer deposition of Al-SiC composites, which have highly tunable structural and coefficient of thermal expansion (CTE) properties. These are crucial for optical payloads because CTE mismatch is one of the causes for degraded optical performance for telescopes in orbit. Overall, the work showed that monolithic telescopes could become a practical, lower-cost path to high-resolution space imaging for both national security and scientific missions.

42 ENGINEERING↗

Updraft and Downdraft Core Size and Intensity as Revealed by Radar Wind Profilers: MCS Observations and Idealized Model Comparisons

This study explores the updraft and downdraft properties of mature stage mesoscale convective systems (MCSs) in terms of draft core width, shape, intensity, and mass flux characteristics. The observations use extended radar wind profiler (RWP) and surveillance radar datasets from the U.S. Department of Energy Atmospheric Radiation Measurement program for midlatitude (Oklahoma, USA) and tropical (Amazon, Brazil) sites. MCS drafts behave qualitatively similar to previous aircraft and RWP cloud summaries. The Oklahoma MCSs indicate larger and more intense convective up- and downdraft cores, and greater mass flux than Amazon MCS counterparts. However, similar size-intensity relationships and draft vertical profile behaviors are observed for both regions. Additional similarities include weak positive correlations between core intensity and core width (correlation coefficient r ~ 0.5), and increases in draft intensity with altitude. A model-observational intercomparison for draft properties (core width, intensity, mass flux) is also performed to illustrate the potential usefulness of statistical observed draft characterizations. Idealized simulations with the Weather Research and Forecasting model aligned with midlatitude MCS conditions are performed at model grid spacings (?x) that range from 4 km to 250 m. It is shown that the simulations performed at ?x = 250 m at similar mature MCS lifecycle stages are those that exhibit draft intensity, width, mass flux, and shape parameter performances best matching with observed properties.

radar, arm, wind profiler, goamazon↗