Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchronization operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Integrated Synchronization Control of Grid-Forming Inverters for Smooth Microgrid Transition

This paper develops an integrated synchronization control technique for a grid-forming inverter operating within a microgrid that can improve the microgrid's transients during microgrid transition operation. This integrated synchronization control includes the disconnection synchronization control and the reconnection synchronization control. The simulation results show that the developed synchronization control works effectively to smooth the angle change of the grid-forming inverter during microgrid transition operation. Thus, the microgrid's transients are significantly improved compared to the case without synchronization control.

control↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗

Equalization in redundant channels

A miscomparison between a channel's configuration data base and a voted system configuration data base in a redundant channel system having identically operating, frame synchronous channels triggers autoequalization of the channel's historical signal data bases in a hierarchical, chronological manner with that of a correctly operating channel. After equalization, symmetrization of the channel's configuration data base with that of the system permits upgrading of the previously degraded channel to full redundancy. An externally provided equalization command, e.g., manually actuated, can also trigger equalization.

Tulpule, Bhalchandra R.↗

Four-phase interleaved TCM DC-DC buck converter with matrix inductor in battery charging application

In this paper, a 1-kW DC-DC buck converter with a four-phase interleaved matrix inductor is proposed for battery charging applications. It is well-known that the DC bias on the inductor will cause high core loss as it changes the B–H characteristic. Typically, the transient conduction mode employed in high voltage applications for zero-voltageswitching of devices would cause higher inductor current ripple. The conventional approach to reduce the effect of DC bias and inductor current ripple is employing multi-phases. However, the cost and size of the converter will increase significantly. This paper proposes the matrix inductor which has a small volume and reduces the effect of the DC bias by flux sharing and flux cancellation at the same time, results in low inductor core loss. With the interleaved operations the output current ripple can be lower which is suitable for battery charging application. Besides, the comparison of the synchronous and interleaved operation is presented. A 1-kW prototype is built and the experimental results show that the peak efficiency is 99.1% and 99.2% for synchronous and interleaved control, respectively. Additionally, the output current ripple of the interleaved operation is reduced by 85% in comparison with the synchronous operation.

14 SOLAR ENERGY↗

Initial utility experience with cluster of three Mod-2 wind turbine systems

This paper describes the initial utility experiences of operating three MOD-2s during the Engineering Acceptance Testing. Electrical quantities of bus voltage, phase currents and power are initially being recorded to evaluate impacts to customers on the 69-kV subtransmission line during synchronization and operation of one or more WTSs. To date, effects on the system have been essentially undetectable. Measurements of television signal strengths were taken at an existing television remote pickup and relay station at the WTS site. Potential TV signal interference problems from the WTSs have been avoided by replacing the remote pickups with microwave repeater links for the four TV channels received from Portland, Oregon. Preliminary measurements of audible and sub-audible noise levels indicate that the upwind rotor, tubular tower design of the MOD-2 does not have the pulsing high intensity infrasound problems experienced by the MOD-1 machine at Boone, North Carolina.

Seely, D. B.↗

The multiple-function multi-input/multi-output digital controller system for the AFW wind-tunnel model

A real time multiple-function digital controller system was developed for the Active Flexible Wing (AFW) Program. The digital controller system (DCS) allowed simultaneous execution of two control laws: flutter suppression and either roll trim or a rolling maneuver load control. The DCS operated within, but independently of, a slower host operating system environment, at regulated speeds up to 200 Hz. It also coordinated the acquisition, storage, and transfer of data for near real time controller performance evaluation and both open- and closed-loop plant estimation. It synchronized the operation of four different processing units, allowing flexibility in the number, form, functionality, and order of control laws, and variability in the selection of the sensors and actuators employed. Most importantly, the DCS allowed for the successful demonstration of active flutter suppression to conditions approximately 26 percent (in dynamic pressure) above the open-loop boundary in cases when the model was fixed in roll and up to 23 percent when it was free to roll. Aggressive roll maneuvers with load control were achieved above the flutter boundary. The purpose here is to present the development, validation, and wind tunnel testing of this multiple-function digital controller system.

Hoadley, Sherwood T.↗

Dispatch Manager for NEML2 Constitutive Model Calculations Embedded in MOOSE

This report describes the extended capabilities of the NEML2 constitutive modeling library, including a flexible and efficient work dispatching system designed to leverage both CPU and GPU resources. This enhancement addresses one of the primary computational challenges in large-scale simulations: the ability to distribute and execute batches of material model evaluations across heterogeneous computing devices. The new dispatch system introduces a modular set of dispatcher and scheduler classes that coordinate the flow of data and execution between devices. The dispatcher is responsible for efficiently packaging work, managing device-specific memory operations, and synchronizing results. This modularity allows for extensibility, making it straightforward to integrate additional computing backends in the future. From an implementation standpoint, the dispatcher system interfaces seamlessly with NEML2's existing models. They handle device-aware tensor operations, optimize memory transfers, and support asynchronous execution when applicable. This design ensures that batches of material points can be evaluated concurrently, substantially improving throughput compared to previous single-device or serial implementations. These improvements not only enhance the raw performance of NEML2 but also improve its usability in multiscale and high-fidelity simulations, where the simultaneous evaluation of large material point batches is critical. Benchmarks included in the report demonstrate the system’s scalability, highlighting its effectiveness when leveraging modern GPU architectures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The multiple-function multi-input/multi-output digital controller system for the AFW wind tunnel model

A real-time multiple-function digital controller system was developed for the Active Flexible Wing (AFW) Program. The digital controller system (DCS) allowed simultaneous execution of two control laws: flutter suppression and either roll trim or a rolling maneuver load control. The DCS operated within, but independently of, a slower host operating system environment, at regulated speeds up to 200 Hz. It also coordinated the acquisition, storage, and transfer of data for near real-time controller performance evaluation and both open- and closed-loop plant estimation. It synchronized the operation of four different processing units, allowing flexibility in the number, form, functionality, and order of control laws, and variability in selection of sensors and actuators employed. Most importantly, the DCS allowed for the successful demonstration of active flutter suppression to conditions approximately 26 percent (in dynamic pressure) above the open-loop boundary in cases when the model was fixed in roll and up to 23 percent when it was free to roll. Aggressive roll maneuvers with load control were achieved above the flutter boundary.

Hoadley, Sherwood T.↗

Payloads simulation in the Shuttle Mission Training Facility

The Shuttle Mission Training Facility (SMFT) at the NASA Johnson Space Center is the primary facility for full mission training of astronauts. The training provided in the SMTF includes payload operations that are performed by the astronauts while the Space Shuttle is in orbit. This training requires real-time simulation of the operational aspects of Shuttle payloads as well as simulation of the interaction between payloads and the Orbiter. For this purpose the SMTF contains Payloads Simulators (PLS) that are coupled to and operated in synchronization with the Shuttle Vehicle Simulators. The PLS are used for simulating all payloads with the exception of the European Space Agency's Spacelab. The SMTF contains a separate Spacelab Simulator for training Spacelab astronauts. This paper provides a synopsis of actual payload operations, the methodology for payload simulation in the SMTF, and the system architecture of the PLS.

Hajare, Ankur R.↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation: Preprint

This paper develops a non-phase-locked loop (PLL) grid-connected inverter that can improve the microgrid’s transients during transition operation. By emulating the operation of a synchronous machine, the inverter generates its own voltage and frequency during startup, synchronizes and connects to the grid, then operates in reactive power mode (grid-feeding) with self-generated voltage and frequency, and switches to voltage-frequency mode to establish system voltage and frequency (grid-forming) when the microgrid disconnects from the main grid, and vice versa. To enable fast synchronization, active synchronization control is adopted both during inverter startup and microgrid reconnection operation. The simulation results show that the developed non-PLL grid-connected inverter works effectively to synchronize the inverter and microgrid to the grid and avoids a phase jump during microgrid transition operation. Thus, the microgrid’s transients are significantly improved with the proposed control technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Satellite Nuclear Power Station - An option for future power generation.

A new concept in nuclear power generation is being explored which essentially eliminates major objections to nuclear power. The Satellite Nuclear Power Station, remotely operated in synchronous orbit, would transmit power safely to the ground by a microwave beam. Fuel reprocessing would take place in space and no radioactive materials would ever be returned to earth. Even the worst possible accident to such a plant should have negligible effect on the earth. An exploratory study of a satellite nuclear power station to provide 10,000 MWe to the earth has shown that the system could weigh about 20 million pounds and cost less than $1000/KWe. An advanced breeder reactor operating with an MHD power cycle could achieve an efficiency of about 50% with a 1100 K radiator temperature. If a hydrogen moderated gas core reactor is used, its breeding ratio of 1.10 would result in a fuel doubling time of a few years. A rotating fluidized bed or NERVA type reactor might also be used. The efficiency of power transmission from synchronous orbit would range from 70% to 80%.

Williams, J. R.↗

Control and synchronization of rapid nanoscale DNA heat engine by local heating

To further activate devices based on DNA nanotechnology, we introduce an approach that notably enhances both the speed and force of DNA powered machines and artificial hinge machine. A microheater, with millisecond response, heats or recools DNA origami constructs, hybridizing or dehybridizing sticky ends. Because anything within 20 micrometers of the heater equilibrates to a programmed temperature change in milliseconds, sticky ends of a compound DNA origami machine can open and close synchronously and operate cooperatively, in phase, additively increasing the drive force compared to single pair of sticky ends DNA machine (the six-helix bundle DNA origami hinge machine). In our demonstrations, we fold and unfold two square origami with 10 pairs of complementary sticky ends to drive a bead on the end of a rod like origami to speeds exceeding 30 micrometers per second. Our device envisions the creation of complex, synchronized DNA machines.

Science & Technology - Other Topics↗

Stirling Engine Controller

Stirling technology is being developed to replace RTG s (Radioisotope Thermoelectric Generators), more specifically a stirling convertor, which is a stirling engine coupled to a linear alternator. Over the past three decades, the stirling engine has been designed to perform different functions. Stirling convertors have been designed to decrease fuel consumption in automobiles. They have also been designed for terrestrial and space applications. Currently NASA Glenn is using the convertor for space based applications. A stiring converter is a better means of power for deep space mission and "dusty" mission, like the Mars Rovers, than solar panels because it is not affected by dust. Spirit and Opportunity, two Mars rovers currently navigating the planet, are losing their ability to generate electricity because dust is collecting on their solar panels. Opportunity is losing more energy because its robotic arm has a heater with a switch that can not be turned off. The heater is not needed at night, but yet still runs. This generates a greater loss of electricity and in turn diminishes the performance of the rover. The stirling cycle has the potential to provide very efficient conversion of heat energy to electric a1 energy, more so than RTG's. The stirling engine converts the thermal energy produced by the decaying radioisotope to mechanical energy; the linear alternator converts this into electricity. convertor. Since the early 1990's tests have been performed to maximize the efficiency of the stirling converter. Many months, even years, are dedicated to preparing and performing tests. Currently, two stirling convertors #'s 13 and 14, which were developed by Stirling Technology Company, are on an extended operation test. As of June 7th, the two convertors reached 7,500 hours each of operation. Before the convertors could run unattended, many safety precautions had to be examined. So, special instrumentation and circuits were developed to detect off nominal conditions and also safely shutdown the engines. The test will last for a period of 8000 to 9000 hours. Other types of tests that have been performed are: performance mapping, controller development, launch environment, and vibration emissions testing. Currently, the thermo-mechanical system branch is housing a RG-350, a stirling convertor. The convertor was used in previous tests such as a Hall Thruster test, world s first integrated test of a dynamic power system with electric propulsion. Another test performed was to conclude if free piston stirling convertors can be synchronized for vibration balancing, with no thermodynamic or electrical connections and not cause both to shutdown if one failed. The ability to reduce vibration by synchronizing convertor operation but still be able to operate when one partner fails is pertinent in space and terrestrial applications. The convertor is now being brought back into operation and a controller is in the process of being developed. This convertor will be used as a testbed for new controllers. I worked with Mary Ellen Roth on the electric engineering aspects of the RG-350. My main goal was to enhance the data collection process. I worked on different aspects of the RG-350, with a main focus on the engine controller. I drew a schematic of the wire connections in the engine controller, using PCB Express, so that a plan could be devised to connect the power meter properly between the output of the engine and the engine controller. I measured the power using two different instruments: Valhalla Scientific power meter and Ohio Semitronics power measurement device. The convertor is connected to an Agilent 34970A Data Acquisition/Switch Unit, which allows the user to measure, record, and monitor voltage, current, frequency, and temperature. I assisted in preparing the Data Acquisition for general operation. I also helped test a panel of transducers, which will be placed in the rack that powers and monitors the convertor.

Blaze, Gina M.↗

LEBT Buncher / Feed Forward / Frequency Generation: System Design Document (SDD)

The LAMP Low Energy Beam Transport (LEBT) transfers a continuous beam at 100 keV from the ion source to RFQ in LEBT. A LEBT buncher imposes an energy tilt to initiate velocy bunching in the chopped beam pulse about 25 ns long to form a short MPEG bunch. One possible option for the LEBT buncher based on a two-gap LC-circuit driven structure was considered, which is similar to the existing LANSCE low-frequncy buncher (LFB). Another possible option is a non-resonant element driven by a pulse-forming-network that provides a single pulse at the repetition frequency of MPEG beam, with a period of 1.8 µs. The LEBT operation is synchronized with the accelerator timing system.

43 PARTICLE ACCELERATORS↗

Stereographic observations from geosynchronous satellites - An important new tool for the atmospheric sciences

Observations of cloud geometry using scan-synchronized stereo geostationary satellites having images with horizontal spatial resolution of approximately 0.5 km, and temporal resolution of up to 3 min are presented. The stereo does not require a cloud with known emissivity to be in equilibrium with an atmosphere with a known vertical temperature profile. It is shown that absolute accuracies of about 0.5 km are possible. Qualitative and quantitative representations of atmospheric dynamics were shown by remapping, display, and stereo image analysis on an interactive computer/imaging system. Applications of stereo observations include: (1) cloud top height contours of severe thunderstorms and hurricanes, (2) cloud top and base height estimates for cloud-wind height assignment, (3) cloud growth measurements for severe thunderstorm over-shooting towers, (4) atmospheric temperature from stereo heights and infrared cloud top temperatures, and (5) cloud emissivity estimation. Recommendations are given for future improvements in stereo observations, including a third GOES satellite, operational scan synchronization of all GOES satellites and better resolution sensors.

Hasler, A. F.↗

Grid Integration of Small-Scale Photovoltaic Systems in Secondary Distribution Network—A Review

The relative share of renewable energy, specifically the solar photovoltaic (PV), is increasing exponentially in the world electric energy sector. This is a cumulative result of reduction in the cost of solar panels, improvement in the panel efficiency, and advancement in the associated power electronics. Among different types of PV plants, installation of small-scale rooftop PV is growing rapidly due to direct end-user benefits and lucrative governmental incentives. There are various standards developed in regards to grid integration of PVs and other distributed generations (DGs). Different power converter topologies are developed to interface the PV panel with the utility grid. To keep up with the stringent regulations imposed by the standards, various control strategies and grid synchronization methods have been developed. This review article amalgamates and summarizes all of the aforementioned aspects of a grid-integrated PV system including various standards, power stage architectures, grid synchronization methods, operation under extreme events, and control methodologies, pertaining to small-scale PV plants. This article will help freshman researchers to gain some familiarity with the topic and introduce them to some of the key issues encountered in this field.

14 SOLAR ENERGY↗

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗