Search NASA⌕ Search

SEARCH · Search NASA

Results for “table detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. At any one location, if multiple radionuclides are detected, then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2009, the potential dose from radiological emissions to air, resulting from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.69 mrem/yr, well below the 10 mrem/yr dose limit. Air sampling data collected at all six critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers from potential release points on the NTS, concentrations at this location would be only a small fraction of that measured on the NTS. The potential dose to the public from NLVF emissions was also very low at 0.000044 mrem/yr, 230,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2009

The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office operates the Nevada Test Site (NTS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the NLVF, an NTS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) limits the release of radioactivity from a U.S. Department of Energy facility to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from sources such as medically or commercially used radionuclides. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2. At any one location, if multiple radionuclides are detected, then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2009, the potential dose from radiological emissions to air, resulting from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.69 mrem/yr, well below the 10 mrem/yr dose limit. Air sampling data collected at all six critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61. Concentrations ranged from less than 1 percent to a maximum of 17 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers from potential release points on the NTS, concentrations at this location would be only a small fraction of that measured on the NTS. The potential dose to the public from NLVF emissions was also very low at 0.000044 mrem/yr, 230,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of far-infrared (C-13)O line emission

Observations of the Ori KL star-formation region, obtained in the 151.4315-micron line of (C-13)O using the MkII UCB cryogenic tandem Fabry-Perot spectrometer on the NASA Kuiper Airborne Observatory in January 1988, are reported. The data are presented in tables and graphs and characterized in detail. The emission detected is found to be consistent with 10-30 solar masses of dense gas at temperature 200 K or greater, or with two or more regions (optically thin emission from a zone at 700 K or more and optically thick emission from a region of high column density identified with the hot core).

Genzel, R.↗

Performance of a Borehole X-ray Fluorescence Spectrometer for Planetary Exploration

We have designed and constructed a borehole X-ray Fluorescence Spectrometer (XRFS) as part of the Mars Subsurface Access program [1]. It can be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary requirements and performance metrics for the instrument are to obtain parts-per-million (ppm) lower limits of detection over a wide range of elements in the periodic table (Magnesium to Lead). Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight ppm for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

Kelliher, Warren C.↗

LLNL Instrument Capable of Detecting Methane Releases

Methane releases in substantial quantities can occur during shale formation fracking. Table 1 in Reference 1 gives a broad range of 12,000 to 680,000 m 3 /day (300 to 17,000 ft 3 /min) of methane release during the “flow-back” period of establishing a well. The ability to detect and possibly quantify these releases and leaks in the natural gas production system is valuable for economic and environmental reasons. Under DOE NNSA funding, LLNL has developed a series of long wave, hyperspectral sensors which have been used successfully for many years in gas and solids detection work. The technology allows a spectrum to be measured for each pixel in an imaged scene, with the spectrum covering the ~7.5 to 13.5 micron range in 258 wave bands. These sensors have been developed for both ground-based and airborne platforms. This work shows that these mature sensors can be flown to detect methane releases associated with natural gas production.

03 NATURAL GAS↗

Nevada Test Site National Emission Standards for Hazardous Air Pollutants Calendar Year 2008

The Nevada Test Site (NTS) is operated by the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office. From 1951 through 1992, the NTS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NTS activities has been monitored since the initiation of atmospheric testing. Limitation to under-ground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NTS. After nuclear testing ended in 1992, NTS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by winds) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of tritium were also emitted to air at the North Las Vegas Facility (NLVF), an NTS support complex in the city of North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR, 2008a) limits the release of radioactivity from a U.S. Department of Energy facility (e.g., the NTS) to 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation not related to NTS activities. Unrelated doses could come from naturally occurring radioactive elements or from other man-made sources such as medical treatments. The NTS demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations. This method was approved by the U.S. Environmental Protection Agency for use on the NTS in 2001 and has been the sole method used since 2005. Six locations on the NTS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration of each detected radionuclide at each of these locations is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2 (CFR, 2008a). At any one location, if multiple radionuclides are detected then compliance with NESHAP is demonstrated when the sum of the fractions (determined by dividing each radionuclide's concentration by its CL and then adding the fractions together) is less than 1.0. In 2008, the potential dose from radiological emissions to air, from both current and past NTS activities, at onsite compliance monitoring stations was a maximum of 1.9 mrem/yr; well below the 10 mrem/yr dose limit. Air sampling data collected at all six pseudo-critical receptor stations had average concentrations of radioactivity that were a fraction of the CL values listed in Table 2 in Appendix E of 40 CFR 61 (CFR, 2008a). Concentrations ranged from less than 1 percent to a maximum of 19 percent of the allowed NESHAP limit. Because the nearest member of the public resides approximately 20 kilometers (12 miles) from the NTS boundary, concentrations at this location would be only a small fraction of that measured on the NTS. Potential dose to the public from NLVF was also very low at 0.00006 mrem/yr; more than 160,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On absorption by hot interstellar gas. II - The 5303-A forbidden line of Fe XIV

Spectroscopic observations of 29 stars at 5303 A obtained with the coude spectrograph on the 2.7-m reflector at McDonald Observatory during 1979-1983 are reported. Instrumental FWHM resolution is 27, 54, or 10 pm, and detection limits near 100 fm equivalent width are obtained in optimal cases. The results are presented in tables and a diagram. No absorption attributable to Fe XIV in hot interstellar gas is detected except for HD 93521, on Apr. 10, 1981, only. This absorption can be located either in interstellar gas at 1.2 million K or less with an Fe XIV/Fe X ratio greater than 3 or in hot gas confined in an inhomogeneous stellar corona.

Hobbs, L. M.↗

Model evaluation guidelines for geomagnetic index predictions

Geomagnetic indices are convenient quantities that distill the complicated physics of some region or aspect of near–Earth space into a single parameter. Most of the best–known indices are calculated from ground–based magnetometer data sets, such as Dst, SYM–H, Kp, AE, AL, and PC. Many models have been created that predict the values of these indices, often using solar wind measurements upstream from Earth as the input variables to the calculation. This document reviews the current state of models that predict geomagnetic indices and the methods used to assess their ability to reproduce the target index time series. These existing methods are synthesized into a baseline collection of metrics for benchmarking a new or updated geomagnetic index prediction model. These methods fall into two categories: (1) fit performance metrics such as root mean square error (RMSE) and mean absolute error (MAE) that are applied to a time–series comparison of model output and observations; and (2) event detection performance metrics such as Heidke Skill Score and probability of detection (POD) that are derived from a contingency table that compares model and observation values exceeding (or not) a threshold value. Furthermore, a few examples of codes being used with this set of metrics are presented, and other aspects of metrics assessment best practices, limitations, and uncertainties are discussed, including several caveats to consider when using geomagnetic indices.

79 ASTRONOMY AND ASTROPHYSICS↗

Complete Evaluation on Advanced Reactor Machine Learning Subversion Attacks (Final)

Navigating through the world of Artificial Intelligence (AI) in nuclear reactors and their Instrumentation and Control (I&C) systems demands a careful, deliberate journey. AI’s capability to manage massive datasets and streamline control systems has indeed carved out a significant role in various sectors, including nuclear energy. However, while AI, and particularly Large Language Models (LLMs), bring a lot to the table in terms of operational efficiency and anomaly detection, they also expose the sector to a new breed of cybersecurity threats, like Inference Attacks, Adversarial Attacks, and Trojan Attacks. This guide is designed to be a straightforward manual, diving deep into the intertwining worlds of AI and cybersecurity within nuclear reactors, and tailoring insights for three crucial audiences: I&C Vendors/Developers, Nuclear Regulators, and Nuclear Reactor Operators and Cyber Defense Teams. (1) Section 2, directed at I&C Vendors/Developers, will provide a clear and focused look at several cybersecurity attacks, offering practical recommendations and detailed scenarios related to AI cybersecurity. This section isn’t just about identifying problems but also about giving solid, usable solutions. (2) Section 3, meant for Nuclear Regulators, gets straight to the point about regulations, policy suggestions, and guidelines that are needed to lay down a robust, secure, and ethical foundation for the application of AI in nuclear operations. The focus is on making sure that everything adheres to international standards and laws while being practicable and clear-cut. (3) Section 4, aimed at Nuclear Reactor Operators and Cyber Defense Teams, offers an exhaustive exploration and technical reports, with clear recommendations and scenario analyses vital to protect operational environments and guarantee the secure application of AI in nuclear reactor operations. The goal is simple: as we step into an era where AI becomes a fundamental element of our technological and energy infrastructures, this guide is here to act as a clear, direct handbook, ensuring that AI is implemented within the nuclear sector in a manner that is secure, responsible, and practical. It’s about striking a balance – optimizing the undeniable benefits offered by AI while securing and shielding against potential cyber threats as we move through this new and complex landscape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

GLEAM: Galaxy Line Emission & Absorption Modeling

We present Galaxy Line Emission & Absorption Modeling (gleam), a Python tool for fitting Gaussian models to emission and absorption lines in large samples of 1D extragalactic spectra. gleam is tailored to work well in batch mode without much human interaction. With gleam, users can uniformly process a variety of spectra, including galaxies and active galactic nuclei, in a wide range of instrument setups and signal-to-noise regimes. gleam also takes advantage of multiprocessing capabilities to process spectra in parallel. With the goal of enabling reproducible workflows for its users, gleam employs a small number of input files, including a central, user-friendly configuration in which fitting constraints can be defined for groups of spectra and overrides can be specified for edge cases. For each spectrum, gleam produces a table containing measurements and error bars for the detected spectral lines and continuum and upper limits for nondetections. For visual inspection and publishing, gleam can also produce plots of the data with fitted lines overlaid. In the present paper, we describe gleam’s main features, the necessary inputs, expected outputs, and some example applications, including thorough tests on a large sample of optical/infrared multi-object spectroscopic observations and integral field spectroscopic data. gleam is developed as an open-source project hosted at https://github.com/multiwavelength/gleam and welcomes community contributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Passive microwave rain estimation over land and ocean at 37 GHz

The use of Nimbus-7 Scanning Multichannel Microwave Radiometer brightness-temperature data to estimate rain rates is discussed in a review of the author's recent experimental investigations. The performance of multiple-frequency spring, summer, and fall rain-rate algorithms for use over land; a single-frequency (37-GHz) algorithm for use over warm oceans; and 37-GHz brightness-temperature criteria for detecting severe thunderstorms is presented in graphs and tables and briefly characterized. The potential value of a microwave radiometer in GEO is indicated.

Spencer, R. W.↗

Sungrazing comets observed by the Solar Maximum Mission coronagraph

The 10 sun-grazing comets (all members of the Kreutz group) detected by the white-light coronagraph of the SMM satellite during its 6-year operational lifetime are described. Numerical data are summarized in tables, and images are provided. Consideration is given to the question of detectability, apparent motions and orbits, coma brightness variations, tail behavior, and occurrence rates. The data are shown to confirm the episodic nature of sun-grazing events, as suggested by Marsden (1967).

Macqueen, R. M.↗

Telescope pointing for GOPEX

In order for photons emitted by the GOPEX lasers to be detected by Galileo's camera, the telescopes at Table Mountain Observatory and Starfire Optical Range had to be pointed in the right direction within a tolerance less than the beam divergence. At both sites nearby stars were used as pointing references. The technical challenge was to ensure that the transmission direction and the star positions were specified in exactly the same coordinate system; given this assurance, neither the uncertainty in the star catalog positions nor the difficulty in offset pointing was expected to exceed the pointing error budget. The correctness of the pointing scheme was verified by the success of GOPEX.

Owen, W. M., Jr.↗

Tables for Trials and Failures with PD for Designated Confidence Level

Two attachments are provided for performance testing of sensors and other Physical Protection System (PPS) components. The first attachment is a table of Trials and Failures, giving Probability of Detection (PD) for a designated confidence level and sorted by trials. The second attachment contains the same data, sorted by failures.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Stationary table CT dosimetry and anomalous scanner-reported values of CTDI{sub vol}

Purpose: Anomalous, scanner-reported values of CTDI{sub vol} for stationary phantom/table protocols (having elevated values of CTDI{sub vol} over 300% higher than the actual dose to the phantom) have been observed; which are well-beyond the typical accuracy expected of CTDI{sub vol} as a phantom dose. Recognition of these outliers as “bad data” is important to users of CT dose index tracking systems (e.g., ACR DIR), and a method for recognition and correction is provided. Methods: Rigorous methods and equations are presented which describe the dose distributions for stationary-table CT. A comparison with formulae for scanner-reported values of CTDI{sub vol} clearly identifies the source of these anomalies. Results: For the stationary table, use of the CTDI{sub 100} formula (applicable to a moving phantom only) overestimates the dose due to extra scatter and also includes an overbeaming correction, both of which are nonexistent when the phantom (or patient) is held stationary. The reported DLP remains robust for the stationary phantom. Conclusions: The CTDI-paradigm does not apply in the case of a stationary phantom and simpler nonintegral equations suffice. A method of correction of the currently reported CTDI{sub vol} using the approach-to-equilibrium formula H(a) and an overbeaming correction factor serves to scale the reported CTDI{sub vol} values to more accurate levels for stationary-table CT, as well as serving as an indicator in the detection of “bad data.”.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RESULTS FOR THE SECOND QUARTER 2010 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2010 Second Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC).1 Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 94}Nb and {sup 144}Ce are above both the established and requested limits from References 4 and 6. (3) The reported detection limits for {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 4. However, they are below the limits established in Reference 6. (4) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC. (5) A measurable concentration of Norpar 13 is present in the sample. The reported concentration is greater than the requested limit from Table 4 and Attachment 8.2 of the WAC. (6) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of the analytes in Tank 50. (7) The detection limit for isopropanol has been lowered from 0.5 mg/L to 0.25 mg/L{sup 7}. This revised limit now satisfies the limit in Table 4 of the WAC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proton-transfer-reaction/ion-mobility-spectrometer and method of using the same

A high-pressure hollow cathode ionizer is combined with an ion-mobility-spectrometer (IMS) for the detection of trace amounts of organic compounds in gas. The ionizer uses H.sub.3 0.sup.+, ions which do not react with air to ionize the organic compounds and the organic compounds are soft ionized. The ionized organic compounds are detected in the IMS at levels of parts per billion and identified using calibrated reference tables. Applications include but are not limited to the fields of: (1) medicine as a breath analyzer for detection of lung cancer, diabetes, liver cirrhosis, (2) law enforcement in drug interdiction and explosives detection, (3) food monitoring and control, (4) environmental monitoring and (5) space applications.

Kanik, Isik↗

Airborne and Ground-Based Measurements Using a High-Performance Raman Lidar: Ground Based - Part 2

The same RASL hardware as described in part I was installed in a ground-based mobile trailer and used in a water vapor lidar intercomparison campaign, hosted at Table Mountain, CA, under the auspices of the Network for the Detection of Atmospheric Composition Change (NDACC). The converted RASL hardware demonstrated high sensitivity to lower stratospheric water vapor indicating that profiling water vapor at those altitudes with sufficient accuracy to monitor climate change is possible. The measurements from Table Mountain also were used to explain the reason, and correct , for sub-optimal airborne aerosol extinction performance during the flight campaign.

Whiteman, David N.↗