Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Lunar Lava Tubes - The Promise of New Orbital Data

The basaltic plains of the Moon contain lava channels on scales of tens of meters to hundreds of kilometers. Many of these channels are segmented, strongly suggesting that some portions include covered lava tubes. Lunar lava tubes are expected to provide unique environments below the harsh lunar surface, maintaining near-isothermal conditions and substantial shielding from solar and galactic radiation. A lava tube has often been suggested as natural shelter for a future human outpost. Previous searches for lunar lava tubes have been limited by a combination of image resolution and completeness of coverage. The five robotic Lunar Orbiter spacecraft combined to photograph essentially the entire lunar surface with a resolution of 60 m, and covered selected sites with resolutions as high as 2 m. The highest-resolution Apollo images, from the mapping and panoramic cameras, covered swaths totaling 16% of the lunar surface, at resolutions of approximately 5 m. The Lunar Reconnaissance Orbiter -- launched in June 2009 to a polar orbit -- carries a suite of instruments that will revolutionize lunar remote sensing, including the identification and characterization of lava tubes. The Lunar Reconnaissance Orbiter Camera (LROC) system includes a multi-spectral wide-angle camera with a resolution of 70 m, allowing a comprehensive survey of the entire lunar surface. The LROC narrow-angle camera is providing targeted images at resolutions of 0.5 - 2 m, including stereo coverage, which should allow detection of tube entrances and breakdown structures. The Lunar Orbiter Laser Altimeter is producing a global topographic map with a vertical resolution of 1 m and a horizontal resolution of 50 m. These data will be critical to understanding lava dynamics and tube emplacement.

Allen, Carlton C.↗

Techniques for High Contrast Imaging in Multi-Star Systems II: Multi-Star Wavefront Control

Direct imaging of exoplanets represents a challenge for astronomical instrumentation due to the high-contrast ratio and small angular separation between the host star and the faint planet. Multi-star systems pose additional challenges for coronagraphic instruments because of the diffraction and aberration leakage introduced by the additional stars, and as a result are not planned to be on direct imaging target lists. Multi-star wavefront control (MSWC) is a technique that uses a coronagraphic instrument's deformable mirror (DM) to create high-contrast regions in the focal plane in the presence of multiple stars. Our previous paper introduced the Super-Nyquist Wavefront Control (SNWC) technique that uses a diffraction grating to enable the DM to generate high-contrast regions beyond the nominal controllable region. These two techniques can be combined to generate high-contrast regions for multi-star systems at any angular separations. As a case study, a high-contrast wavefront control (WC) simulation that applies these techniques shows that the habitable region of the Alpha Centauri system can be imaged reaching 8 times 10(exp -9) mean contrast in 10 percent broadband light in one-sided dark holes from 1.6-5.5 lambda (wavelength) divided by D (distance).

Sirbu, D.↗

Giant Planets in Reflected Light: What Science Can We Expect?

Interpreting the reflection spectra of cool giant planets will be a challenge. Spectra of such worlds are expected to be primarily shaped by scattering from clouds and hazes and punctuated by absorption bands of methane, water, and ammonia. While the warmest giants may be cloudless, their atmospheres will almost certainly sport substantial photochemical hazes. Furthermore the masses of most direct imaging targets will be constrained by radial velocity observations, their radii, and thus atmospheric gravity, will be imperfectly known. The uncertainty in planet radius and gravity will compound with uncertain aerosol properties to make estimation of key absorber abundances difficult. To address such concerns our group is developing atmospheric retrieval tools to constrain quantities of interest, particular gas mixing ratios. We have applied our Markov Chain Monte Carlo methods to simulated data of the quality expected from the WFIRST CGI instrument and found that given sufficiently high SNR data we can confidentially identify and constrain the abundance of methane, cloud top pressures, gravity, and the star-planet-observer phase angle. In my presentation I will explain the expected characteristics of cool extrasolar giant planet reflection spectra, discuss these and other challenges in their interpretation, and summarize the science results we can expect from direct imaging observations.

methane↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Impact of Surface Chemistry of Ultrasmall Superparamagnetic Iron Oxide Nanoparticles on Protein Corona Formation and Endothelial Cell Uptake, Toxicity, and Barrier Function

Ultrasmall superparamagnetic iron oxide nanoparticles (USPIONs) have been investigated for biomedical applications, including novel contrast agents, magnetic tracers for tumor imaging, targeted drug delivery vehicles, and magneto-mechanical actuators for hyperthermia and thrombolysis. Despite significant progress, recent clinical reports have raised concerns regarding USPION safety related to endothelial cell dysfunction; however, there is limited information on factors contributing to these clinical responses. The influence of USPION surface chemistry on nanoparticle interactions with proteins may impact endothelial cell function leading to adverse responses. Therefore, the goal of this study was to assess the effects of carboxyl-functionalized USPION (CU) or amine-functionalized USPION (AU) (approximately 30 nm diameter) on biological responses in human coronary artery endothelial cells. Increased protein adsorption was observed for AU compared with CU after exposure to serum proteins. Exposure to CU, but not AU, resulted in a concentration-dependent decrease in cell viability and perinuclear accumulation inside cytoplasmic vesicles. Internalization of CU was correlated with endothelial cell functional changes under non-cytotoxic conditions, as evidenced by a marked decreased expression of endothelial-specific adhesion proteins (eg, vascular endothelial-cadherin and platelet endothelial cell adhesion molecule-1) and increased endothelial permeability. Evaluation of downstream signaling indicated endothelial permeability is associated with actin cytoskeleton remodeling, possibly elicited by intracellular events involving reactive oxygen species, calcium ions, and the nanoparticle cellular uptake pathway. This study demonstrated that USPION surface chemistry significantly impacts protein adsorption and endothelial cell uptake, viability, and barrier function. This information will advance the current toxicological profile of USPION and improve development, safety assessment, and clinical outcomes of USPION-enabled medical products.

Toxicology↗

Discorpy : algorithms and software for camera calibration and correction

Camera or lens-based detector calibration is essential for spatial accuracy in applications like dimensional tomography, optical metrology, and computer vision. Many methods and software exist yet there is still a lack of approaches that achieve both high accuracy and robustness while being easy to use and capable of handling a wide range of distortions. Radial lens distortion is common in high-resolution X-ray detector optics used in parallel-beam tomography at synchrotrons. Achieving sub-pixel accuracy requires calibrating with an optical target image. Although methods for characterizing radial distortion are well established, acquired images often also include perspective distortion and optical center offset. Here, we present our approaches to individually characterize and correct both types of distortion using a single calibration image, implemented in the Discorpy software.

36 MATERIALS SCIENCE↗

Using coherent dipion photoproduction to image gold nuclei

Vector meson photoproduction offers the opportunity to image target nuclei. The two-dimensional Fourier transform d\sigma_{coherent}/dt d σ c o h e r e n t / d t of coherent vector meson photoproduction gives the two-dimensional distribution of interaction sites in the target. Since vector meson photoproduction occurs, at lowest order, via two-gluon exchange, this is sensitive to gluon shadowing. We present an analysis of \pi^+\pi^- π + π − photoproduction using data from the STAR detector and a study of d\sigma_{coherent}/dt d σ c o h e r e n t / d t , with an emphasis on probing the nuclear shape and its systematic uncertainties.

Klein, Spencer↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

A closed-loop control-loading system

Langley Differential Maneuvering Simulator (DMS) realistically simulates two aircraft operating in differential mode. It consists of two identical fixed-base cockpits and dome projection systems. Each projection system consists of sky/Earth projector and target-image generator and projector. Although programmable control forces are small part of overall system, they play large role in providing pilot with kinesthetic cues.

Ashworth, B. R.↗

Effect of weighting on time sidelobe suppression

Weighting simulations in the time domain were considered to shape the time-compressed pulse waveform. The digital input radar data were 32 bit I,Q, and simulated data from a point target, imaged by a Seasat-A type system. Weighting functions tested include stepped-amplitude distributions, (with 1 through 5 steps), and the cosine-squared plus pedestal distribution. Effects treated include mainlobe ratio, signal to noise ratio, and nearest sidelobe suppression.

Dicenzo, A.↗

The effects of window shape and reticle presence on performance in a vertical alignment task

This study was conducted to evaluate the effect of selected interior work-station orientational cuing upon the ability to align a target image with local vertical in the frontal plane. Angular error from gravitational vertical in an alignment task was measured for 20 observers viewing through two window shapes (square, round), two initial orientations of a computer-generated space shuttle image, and the presence or absence of a stabilized optical alignment reticle. In terms of overall accuracy, it was found that observer error was significantly smaller for the square window and reticle-present conditions than for the round window and reticle-absent conditions. Response bias data reflected an overall tendency to undershoot and greater variability of response in the round window/no reticle condition. These results suggest that environmental cuing information, such as that provided by square window frames and alignment reticles, may aid in subjective orientation and increase accuracy of response in a Space Station proximity operations alignment task.

Rosenberg, Erika L.↗

Sub-electron noise charge coupled devices

A charge coupled device designed for celestial spectroscopy has achieved readout noise as low as 0.6 electrons rms. A nondestructive output circuit was operated in a special manner to read a single pixel multiple times. Off-chip electronics averaged the multiple values, reducing the random noise by the square root of the number of readouts. Charge capacity was measured to be 500,000 electrons. The device format is 1600 pixels horizontal by 64 pixels vertical. Pixel size is 28 microns square. Two output circuits are located at opposite ends of the 1600 bit CCD register. The device was thinned and operated backside illuminated at -110 degrees C. Output circuit design, layout, and operation are described. Presented data includes the photon transfer curve, noise histograms, and bar-target images down to 3 electrons signal. The test electronics are described, and future improvements are discussed.

Chandler, Charles E.↗

Automatic target recognition using a feature-based optical neural network

An optical neural network based upon the Neocognitron paradigm (K. Fukushima et al. 1983) is introduced. A novel aspect of the architectural design is shift-invariant multichannel Fourier optical correlation within each processing layer. Multilayer processing is achieved by iteratively feeding back the output of the feature correlator to the input spatial light modulator and updating the Fourier filters. By training the neural net with characteristic features extracted from the target images, successful pattern recognition with intra-class fault tolerance and inter-class discrimination is achieved. A detailed system description is provided. Experimental demonstration of a two-layer neural network for space objects discrimination is also presented.

Chao, Tien-Hsin↗

Optical implementation of a feature-based neural network with application to automatic target recognition

An optical neural network based on the neocognitron paradigm is introduced. A novel aspect of the architecture design is shift-invariant multichannel Fourier optical correlation within each processing layer. Multilayer processing is achieved by feeding back the ouput of the feature correlator interatively to the input spatial light modulator and by updating the Fourier filters. By training the neural net with characteristic features extracted from the target images, successful pattern recognition with intraclass fault tolerance and interclass discrimination is achieved. A detailed system description is provided. Experimental demonstrations of a two-layer neural network for space-object discrimination is also presented.

Chao, Tien-Hsin↗

Spacecraft studies of planetary surfaces using bistatic radar

Spaceborne transmitters have been used in bistatic geometries for a number of planetary surface studies including inference of topography, Fresnel reflectivity, and rms surface slopes on the moon, Mars, and Venus. For the moon and Mars in particular, the bistatic geometry has enabled remote probing in regions and under conditions not obtainable with Earth-based radar systems, yielding information about surface characteristics and properties on scales of centimeters to hundreds of meters that complements monostatic radar observations. A new generation of planetary spacecraft now provides opportunities for further experiments, including more nearly complete definition of the surface scattering function and, possibly, imaging. Targets of interest include the polar regions of Venus (by Magellan) and Mars (by Mars Observer), the enigmatic icy Galilean satellites of Jupiter (by Galileo), and Saturn's largest moon Titan (by Cassini).

Simpson, Richard A.↗

Optical-Correlator Neural Network Based On Neocognitron

Multichannel optical correlator implements shift-invariant, high-discrimination pattern-recognizing neural network based on paradigm of neocognitron. Selected as basic building block of this neural network because invariance under shifts is inherent advantage of Fourier optics included in optical correlators in general. Neocognitron is conceptual electronic neural-network model for recognition of visual patterns. Multilayer processing achieved by iteratively feeding back output of feature correlator to input spatial light modulator and updating Fourier filters. Neural network trained by use of characteristic features extracted from target images. Multichannel implementation enables parallel processing of large number of selected features.

Chao, Tien-Hsin↗

Spatial region filtering in IRAF/PROS

In order to analyze x ray data, it is nearly always necessary to extract source and background events from a data set. Typically, this is done by defining geometric spatial regions of the data set to describe the source and background. For example, one might wish to extract source events from a circular or elliptical region centered at a particular pixel, and background events from a circular or elliptical annulus whose inner radius matches the source region. At the same time, it might be necessary to exclude one or more nearby sources from the source or background region in question. Thus, it might be necessary to define a pie-shaped region or even an entirely irregularly-shaped region to exclude. A spatial filtering scheme called REGIONS was implemented in IRAF/PROS to support these and other types of spatial region extraction. It allows users to create a spatial mask by specifying one or more ASCII geometric shape descriptors (box, circle, ellipse, pie, point, annulus, and polygon) as regions to be included or excluded in the mask. In addition, two or more shapes can be combined using Boolean algebra to create an infinite variety of sophisticated regions. Each geometric shape has a specific set of parameters that describe that shape. For example, a circle is described by a center and a radius, while a box is described by a center, length, width, and rotation angle. These quantities can be specified in units of pixels or, in cases where the target image contains world coordinate system information, they can be described in units such as RA and Dec. Users can create region mask files by feeding an ASCII region descriptor to the IRAF/PROS plcreate task. Temporary masks can also be created from ASCII region descriptors by individual applications that call the routines in the region creation library. This library implements a yacc-based region parser that compiles the ASCII descriptors into 'software CPU' instructions which are then executed to create the mask. The mask created from these region descriptors is a standard IRAF PLIO mask. It can be combined with other PLIO masks (e.g., exposure masks) to provide complete spatial filtering capabilities. The capabilities of the region filtering scheme are described. It also discusses the design philosophy guiding our work, as well as our plans for the future.

Mandel, Eric↗