Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

helixCAM: A platform for programmable cellular assembly in bacteria and human cells

Interactions between cells are indispensable for signaling and creating structure. The ability to direct precise cell-cell interactions would be powerful for engineering tissues, understanding signaling pathways, and directing immune cell targeting. In humans, intercellular interactions are mediated by cell adhesion molecules (CAMs). However, endogenous CAMs are natively expressed by many cells and tend to have cross-reactivity, making them unsuitable for programming specific interactions. Here, we showcase “helixCAM,” a platform for engineering synthetic CAMs by presenting coiled-coil peptides on the cell surface. helixCAMs were able to create specific cell-cell interactions and direct patterned aggregate formation in bacteria and human cells. Based on coiled-coil interaction principles, we built a set of rationally designed helixCAM libraries, which led to the discovery of additional high-performance helixCAM pairs. Finally, we applied this helixCAM toolkit for various multicellular engineering applications, such as spherical layering, adherent cell targeting, and surface patterning.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Bioluminescence Tomography-Guided Conformal Irradiation for Preclinical Radiation Research

Widely used cone beam computed tomography (CBCT)-guided irradiators in preclinical radiation research are limited to localize soft tissue target because of low imaging contrast. Knowledge of target volume is a fundamental need for radiation therapy (RT). Without such information to guide radiation, normal tissue can be overirradiated, introducing experimental uncertainties. This led us to develop high-contrast quantitative bioluminescence tomography (QBLT) for guidance. The use of a 3-dimensional bioluminescence signal, related to cell viability, for preclinical radiation research is one step toward biology-guided RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solar Transposition Modeling via Deep Neural Networks With Sky Images

This article presents a notable advance toward the development of a new method of increasing the single-axis tracking photovoltaic (PV) system power output by improving the determination and near-term prediction of the optimum module tilt angle. The tilt angle of the plane receiving the greatest total irradiance changes with Sun position and atmospheric conditions including cloud formation and movement, aerosols, and particulate loading, as well as varying albedo within a module's field of view. In this article, we present a multi-input convolutional neural network that can create a profile of plane-of-array irradiance versus surface tilt angle over a full 180° arc from horizon to horizon. As input, the neural network uses the calculated solar position and clear-sky irradiance values, along with sky images. The target irradiance values are provided by the multiplanar irradiance sensor (MPIS). In order to account for varying irradiance conditions, the MPIS signal is normalized by the theoretical clear-sky global horizontal irradiance. Using this information, the neural network outputs an N -dimensional vector, where N is the number of points to approximate the MPIS curve via Fourier resampling. The output vector of the model is smoothed with a Gaussian kernel to account for error in the downsamping and subsequent upsampling steps, as well as to smooth the unconstrained output of the model. Furthermore, these profiles may be used to perform near-term prediction of angular irradiance, which can then inform the movement of a PV tracker.

42 ENGINEERING↗

3D modeling of deep borehole electromagnetic measurements with energized casing source for fracture mapping at the Utah Frontier Observatory for Research in Geothermal Energy

Here, we present a 3D numerical modelling analysis evaluating the deployment of a borehole electromagnetic measurement tool to detect and image a stimulated zone at the Utah Frontier Observatory for Research in Geothermal Energy geothermal site. As the depth to the geothermal reservoir is several kilometres and the size of the stimulated zone is limited to several 100 m, surface-based controlled-source electromagnetic measurements lack the sensitivity for detecting changes in electrical resistivity caused by the stimulation. To overcome the limitation, the study evaluates the feasibility of using a three-component borehole magnetic receiver system at the Frontier Observatory for Research in Geothermal Energy site. To provide sufficient currents inside and around the enhanced geothermal reservoir, we use an injection well as an energized casing source. To efficiently simulate energizing the injection well in a realistic 3D resistivity model, we introduce a novel modelling workflow that leverages the strengths of both 3D cylindrical-mesh-based electromagnetic modelling code and 3D tetrahedral-mesh-based electromagnetic modelling code. The former is particularly well-suited for modelling hollow cylindrical objects like casings, whereas the latter excels at representing more complex 3D geological structures. In this workflow, our initial step involves computing current densities along a vertical steel-cased well using a 3D cylindrical electromagnetic modelling code. Subsequently, we distribute a series of equivalent current sources along the well's trajectory within a complex 3D resistivity model. We then discretize this model using a tetrahedral mesh and simulate the borehole electromagnetic responses excited by the casing source using a 3D finite-element electromagnetic code. This multi-step approach enables us to simulate 3D casing source electromagnetic responses within a complex 3D resistivity model, without the need for explicit discretization of the well using an excessive number of fine cells. We discuss the applicability and limitations of this proposed workflow within an electromagnetic modelling scenario where an energized well is deviated, such as at the Frontier Observatory for Research in Geothermal Energy site. Using the workflow, we demonstrate that the combined use of the energized casing source and the borehole electromagnetic receiver system offer measurable magnetic field amplitudes and sensitivity to the deep localized stimulated zone. The measurements can also distinguish between parallel-fracture anisotropic reservoirs and isotropic cases, providing valuable insights into the fracture system of the stimulated zone. Besides the magnetic field measurements, vertical electric field measurements in the open well sections are also highly sensitive to the stimulated zone and can be used as additional data for detecting and imaging the target. We can also acquire additional multiple-source data by grounding the surface electrode at various locations and repeating borehole electromagnetic measurements. This approach can increase the number of monitoring data by several factors, providing a more comprehensive dataset for analysing the deep-localized stimulated zone. The numerical analysis indicates that it is feasible to use the combination of the energized casing and downhole electromagnetic measurements in monitoring localized stimulated zone at large depths.

58 GEOSCIENCES↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Compilation and Validation of the Spectroscopic Redshift Catalogs for the DESI-COSMOS and DESI-XMM-LSS Fields

Over several dedicated programs that include targets beyond the main cosmological samples, the Dark Energy Spectroscopic Instrument collected spectra for 304,970 unique objects in two fields centered on the COSMOS and XMM-LSS fields. In this work, we develop spectroscopic redshift robustness criteria for those spectra, validate these criteria using visual inspection, and provide two custom value-added catalogs with our redshift characterizations. With these criteria, we reliably classify 212,935 galaxies below z < 1.6, 9713 quasars, and 35,222 stars. The resulting catalogs achieve a redshift purity exceeding 99.4% across all galaxy samples. As a critical element in characterizing the selection function, we provide the description of 70 different algorithms that were used to select these targets from imaging data. To facilitate joint imaging/spectroscopic analyses, we provide row-matched photometry from the Dark Energy Camera, Hyper-Suprime Cam, and public COSMOS2020 photometric catalogs. Finally, we demonstrate example applications of these large catalogs to photometric redshift estimation, cluster finding, and completeness studies.

Ratajczak, J. [Univ. of Utah, Salt Lake City, UT (↗

Clustering of LRGs in the DECaLS DR8 Footprint: Distance Constraints from Baryon Acoustic Oscillations Using Photometric Redshifts

A photometric redshift sample of luminous red galaxies (LRGs) obtained from the DECam Legacy Survey (DECaLS) is analyzed to probe cosmic distances by exploiting the wedge approach of the two-point correlation function. Although the cosmological information is highly contaminated by the uncertainties existing in the photometric redshifts from the galaxy map, an angular diameter distance can be probed at the perpendicular configuration in which the measured correlation function is minimally contaminated. An ensemble of wedged correlation functions selected up to a given threshold based on having the least contamination was studied in previous work (Sridhar & Song 2019) using simulations, and the extracted cosmological information was unbiased within this threshold. Furthermore, we apply the same methodology for analyzing the LRG sample from DECaLS, which will provide the optical imaging for targeting two-thirds of the Dark Energy Spectroscopic Instrument footprint and measure the angular diameter distances at z = 0.69 and z = 0.87 to be D A (0.697) = (1529 ± 73 Mpe)(r d /r d.fid ) and D A (0.874) = (1674 ± 102 Mpe)(r d /r d.fid ) with a fractional error of 4.77% and 6.09%, respectively. We obtain a value of H 0 = 66.58 ± 5.31 km s -1 Mpc -1 , which supports the H 0 measured by all other baryon acoustic oscillation results and is consistent with the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

rustpix

rustpix is a high-performance, open-source Rust library with first-class Python bindings (via PyO3) for processing pixel-detector data in neutron imaging. It targets time-stamping detectors such as Timepix3 (TPX3) at ORNL's Spallation Neutron Source (VENUS beamline), where each detected neutron deposits charge across a cluster of pixels within a very high-rate event stream (96M+ hits/sec). rustpix parses TPX3 event data in parallel using memory-mapped I/O, offers four interchangeable clustering algorithms (ABS adjacency-based search, DBSCAN, graph/union-find connected components, and a parallel grid method), and extracts weighted, super-resolved centroids to produce neutron-event lists. A streaming architecture lets it process files larger than available memory. rustpix is distributed as a pip-installable Python package (with NumPy integration), Rust crates, a command-line tool, and an interactive GUI; it writes HDF5, Apache Arrow, and CSV; and it is designed to extend to TPX4 and other detector types. Released as open-source under the MIT License.

Zhang, Chen [Oak Ridge National Laboratory (ORNL),↗

Self-Supervised Anomaly Detection via Neural Autoregressive Flows with Active Learning

Many self-supervised methods have been proposed with the target of image anomaly detection. These methods often rely on the paradigm of data augmentation with predefined transformations such as flipping, cropping, and rotations. However, it is not straightforward to apply these techniques for non-image data, such as time series or tabular data, while the performance of the existing deep approaches has been under our expectation on tasks beyond images. In this work, we propose a novel active learning (AL) scheme that relied on neural autoregressive flows (NAF) for self-supervised anomaly detection, specifically on small-scale data. Unlike other generative models such as GANs or VAEs, flow-based models allow to explicitly learn the probability density and thus can assign accurate likelihoods to normal data which makes it usable to detect anomalies. The proposed NAF-AL method is achieved by efficiently generating random samples from latent space and transforming them into feature space along with likelihoods via invertible mapping. The samples with lower likelihoods are selected and further checked by outlier detection using Mahalanobis distance. The augmented samples incorporating with normal samples are used for training a better detector so as to approach decision boundaries. Compared with random transformations, NAF-AL can be interpreted as a likelihood-oriented data augmentation that is more efficient and robust. Extensive experiments show that our approach outperforms existing baselines on multiple time series and tabular datasets, and a real-world application in advanced manufacturing, with significant improvement on anomaly detection accuracy and robustness over the state-of-the-art.

Zhang, Jiaxin↗

Content-aware foveated camera for multi-target tracking

Modern image sensors deliver substantial space-time bandwidth, yet indiscriminate acquisition often overwhelms memory, computation, and downstream perception. We present a content-aware, multi-foveated camera that dynamically reallocates sensing and magnification to multiple regions of interest (ROIs). A phase-only spatial light modulator (SLM) serves as a solid-state, inertia-free beam-steering and lens element, enabling per-frame field-of-view (FOV) reconfiguration and content-aware target tracking. By interleaving frames across foveae, our system preserves a wide-FOV situational context while refreshing each ROI at high rates, thereby reducing data volume without degrading task performance. We constructed a prototype employing a single-SLM, single-sensor architecture and demonstrated its application in real-time multi-object tracking with dynamic ROI maintenance across multiple viewpoints. The approach offers a general pathway to integrate detection, tracking, and segmentation algorithms in the acquisition loop, shifting workload from post hoc processing to intelligent capture.

Zang, Zihan [Univ. of California, Los Angeles, CA ↗

TDCOSMO - XVII. New time delays in 22 lensed quasars from optical monitoring with the ESO-VST 2.6m and MPG 2.2m telescopes

We present new time delays, the main ingredient of time delay cosmography, for 22 lensed quasars resulting from high-cadence r-band monitoring on the 2.6 m ESO VLT Survey Telescope and Max-Planck-Gesellschaft 2.2 m telescope. Each lensed quasar was typically monitored for one to four seasons, often shared between the two telescopes to mitigate the interruptions forced by the COVID-19 pandemic. The sample of targets consists of 19 quadruply and 3 doubly imaged quasars, which received a total of 1918 hours of on-sky time split into 21 581 wide-field frames, each 320 seconds long. In a given field, the 5-σ depth of the combined exposures typically reaches the 27th magnitude, while that of single visits is 24.5 mag – similar to the expected depth of the upcoming Vera-Rubin LSST. The fluxes of the different lensed images of the targets were reliably de-blended, providing not only light curves with photometric precision down to the photon noise limit, but also high-resolution models of the targets whose features and astrometry were systematically confirmed in Hubble Space Telescope imaging. This was made possible thanks to a new photometric pipeline, lightcurver, and the forward modelling method STARRED. Finally, the time delays between pairs of curves and their uncertainties were estimated, taking into account the degeneracy due to microlensing, and for the first time the full covariance matrices of the delay pairs are provided. Of note, this survey, with 13 square degrees, has applications beyond that of time delays, such as the study of the structure function of the multiple high-redshift quasars present in the footprint at a new high in terms of both depth and frequency. The reduced images will be available through the European Southern Observatory Science Portal.Key words: methods: data analysis / surveys / distance scale

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Few-view computed tomography reconstruction using deep neural network inference

A system for generating 2D slices of a 3D image of a target volume is provided. The system receives a target sinogram collected during a computed tomography scan of the target volume. The system inputs the target sinogram to a convolutional neural network (CNN) to generate predicted 2D slices of the 3D image. The CNN is trained using training 2D slices of training 3D images. The system initializes 2D slices to the predicted 2D slices. The system reconstructs 2D slices of the 3D image from the target sinogram and the initialized 2D slices.

Kim, Hyojin↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Three New Late-type Stellar Companions to Very Dusty WISE Debris Disks Identified with SPHERE Imaging

Debris disk stars are good targets for high-contrast imaging searches for planetary systems, since debris disks have been shown to have a tentative correlation with giant planets. We selected 20 stars identified as debris disk hosts by the WISE mission, with particularly high levels of warm dust. We observed these with the VLT/SPHERE high-contrast imaging instrument with the goal of finding planets and imaging the disks in scattered light. Our survey reaches a median 5σ sensitivity of 10.4 M {sub J} at 25 au and 5.9 M {sub J} at 100 au. We identified three new stellar companions (HD 18378B, HD 19257B, and HD 133778B): two are mid-M-type stars and one is a late-K or early-M star. Three additional stars have very widely separated stellar companions (all at >2000 au) identified in the Gaia catalog. The stars hosting the three SPHERE-identified companions are all older (≳700 Myr), with one having recently left the main sequence and one a giant star. We infer that the high volumes of dust observed around these stars has been caused by a recent collision between the planets and planetesimal belts in the system, although for the most evolved star, mass loss could also be responsible for the infrared excess. Future mid-infrared spectroscopy or polarimetric imaging may allow the positions and spatial extent of these dust belts to be constrained, thereby providing evidence as to the true cause of the elevated levels of dust around these old systems. None of the disks in this survey is resolved in scattered light.

47 OTHER INSTRUMENTATION↗

High-resolution 3D microwave imaging using an optically tracked linear array

Active three-dimensional microwave or millimeter-wave imaging is typically performed using a linear array that is mechanically scanned over a uniform planar or cylindrical aperture. However, an image can also be formed with a linear array that is scanned over a non-uniform irregular aperture. This requires that the precise position of the array be known for each radar sample. This paper explores high-resolution 3D microwave imaging of stationary targets using an optically tracked manually scanned linear array. The image reconstruction techniques necessary to account for a non-uniform irregular aperture are also developed.

Clark, Richard T.↗

Optical Test Bench (SYSM 5620 Final Report)

The National Ignition Facility (NIF) is a research facility that focuses on High Energy Density Science and Inertial Confinement Fusion. In the NIF, 192 laser beams are directed into a miniscule Target Capsule to generate an implosion – this is called a NIF Shot. Many NIF Users conduct experiments using different Targets and laser inputs to generate reactions that are of interest to the scientific community. Those reactions are monitored using various Target Diagnostic instruments, including Shot Time Photography – which provides crucial images of the Target as the implosion occurs. A subset of these NIF Users is less interested in the reaction itself and more interested in subjecting materials or devices to the intense environment that these reactions can create. Using the Target as a source of x-rays, neutrons, or blast loading for particular materials has been significant to the shock physics community and to those who work in extreme design spaces. However, the Material and Radiation Effects team – that performs these experiments on behalf of the NIF Users – has not been able to make good use of the existing Shot Time Photography Diagnostics. The STP cameras are focused on the Targets rather than the MRE Customers’ materials, the current system is not oriented to have a good view of the MRE Customers’ materials, and the cameras are limited in their capabilities (black and white, poor resolution, etc.). As MRE experiments increase in quantity and importance to the scientific community, the desire for visual monitoring of the experiments to substantiate models and inform other data is also rising.

42 ENGINEERING↗