Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Detection techniques for tenuous planetary atmospheres

Electrostatic charging of dust and its effect on planetary atmospheres is discussed, along with its applications to Martian atmosphere. Laboratory and field experiments in dust storms indicate that the major atmospheric parameters on Mars include: (1) pressure, temperature, and relative humidity; (2) wind velocity and direction; (3) particulate size and composition; and (4) electrostatic charge and field gradient. Various instrumentation techniques adapted for a Mars Lander are briefly reviewed. The effect of exoelectron emission on surface catalysis is studied.

Hoenig, S. A.↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

A Large, Free-Standing Wire Grid for Microwave Variable-delay Polarization Modulation

One technique for mapping the polarization signature of the cosmic microwave background uses large, polarizing grids in reflection. We present the system requirements, the fabrication, assembly, and alignment procedures, and the test results for the polarizing grid component of a 50 cm clear aperture, Variable-delay Polarization Modulator (VPM). This grid is being built and tested at the Goddard Space Flight Center as part of the Polarimeter for Observing Inflationary Cosmology at the Reionization Epoch (POINCARE). VPMs modulate the polarized component of a radiation source by splitting the incoming beam into two orthogonal polarization components using a free-standing wire grid. The path length difference between these components is varied with a translating mirror, and then they are recombined. This precision instrumentation technique can be used to encode and demodulate the cosmic microwave background's polarization signature. For the demonstration instrument, 64 micrometer diameter tungsten wires are being assembled into a 200 pm pitch, free-standing wire grid with a 50 cm clear aperture, and an expected overall flatness better than 30 micrometers. A rectangular, aluminum stretching frame holds the wires with sufficient tension to achieve a minimum resonant frequency of 185 Hz, allowing VPM mirror translation frequencies of several Hz. A lightly loaded, flattening ring with a 50 cm inside diameter rests against the wires and brings them into accurate planarity.

Voellmer, George↗

Measurement Protocols for In situ Analysis of Organic Compounds at Mars and Comets

The determination of the abundance and chemical and isotopic composition of organic molecules in comets and those that might be found in protected environments at Mars is a first step toward understanding prebiotic chemistries on these solar system bodies. While future sample return missions from Mars and comets will enable detailed chemical and isotopic analysis with a wide range of analytical techniques, precursor insitu investigations can complement these missions and facilitate the identification of optimal sites for sample return. Robust automated experiments that make efficient use of limited spacecraft power, mass, and data volume resources are required for use by insitu missions. Within these constraints we continue to explore a range of instrument techniques and measurement protocols that can maximize the return from such insitu investigations.

Mahaffy, P. R.↗

Measurement Protocols for In Situ Analysis of Organic Compounds at Mars and Comets

The determination of the abundance and chemical and isotopic composition of organic molecules in comets and those that might be found in protected environments at Mars is a first step toward understanding prebiotic chemistries on these solar system bodies. While future sample return missions from Mars and comets will enable detailed chemical and isotopic analysis with a wide range of analytical techniques, precursor insitu investigations can complement these missions and facilitate the identification of optimal sites for sample return. Robust automated experiments that make efficient use of limited spacecraft power, mass, and data volume resources are required for use by insitu missions. Within these constraints we continue to explore a range of instrument techniques and measurement protocols that can maximize the return from such insitu investigations.

Mahaffy, P. R.↗

Medical and surgical applications of space biosensor technology

Researchers in space life sciences are rapidly approaching a technology impasse. Many of the critical questions on the impact of spaceflight on living systems simply cannot be answered with the limited available technologies. Research subjects, particularly small animal models like the rat, must be allowed to function relatively untended and unrestrained for long periods to fully reflect the impact of microgravity and spaceflight on their behavior and physiology. These requirements preclude the use of present hard-wired instrumentation techniques and limited data acquisition systems. Implantable sensors and miniaturized biotelemetry are the only means of capturing the fundamental and critical data. This same biosensor and biotelemetry technology has direct application to Earth-based medicine and surgery. Continuous, on-line data acquisition and improved measurement capabilities combined with the ease and flexibility offered by automated, wireless, and portable instruments and data systems, should provide a boon to the health care industry. Playing a key role in this technology revolution is the Sensors 2000! (S2K!) Program at NASA Ames Research Center. S2K!, in collaboration with space life sciences researchers and managers, provides an integrated capability for sensor technology development and applications, including advanced biosensor technology development, spaceflight hardware development, and technology transfer and commercialization. S2K! is presently collaborating on several spaceflight projects with dual-use medical applications. One prime example is a collaboration with the Fetal Treatment Center (FTC) at the University of California at San Francisco. The goal is to develop and apply implantable chemical sensor and biotelemetry technology to continuously monitor fetal patients during extra-uterine surgery, replacement into the womb, through birth and beyond. Once validated for ground use, the method will be transitioned to spaceflight applications to remotely monitor key biochemical parameters in flight animals. Successful application of NASA implantable biosensor and biotelemetry technologies should accelerate the advancement of this and other modern medical procedures while furthering the exploration of life in space.

NASA Discipline General Space Life Sciences↗

Comparison of HALOE O3 and H2O observations from UARS with ground and balloonborne measurements

The HALogen Occultation Experiment (HALOE) was launched on the Upper Atmosphere Research Satellite (UARS) by the Space Shuttle Discovery at 7:11:04 EDT on September 12, 1991. After allowing for a period of outgassing, HALOE began taking routine science observations on October 11. HALOE uses the experiment approach of solar occultation and the gas filter and broad band radiometer instruments techniques to measure vertical profiles of HCl, HF, CH4, NO, NO2, H2O, O3, aerosol, and temperature versus pressure. The measurements cover a broad altitude range from the upper troposphere in some cases to the lower thermosphere in the case of nitric oxide. Latitude coverage provided by the occultation geometry ranges from 80 deg S to 80 deg N over the course of one year. The experiment has operated essentially without flaw for more than three years. Instrument stability over this time, as judged by the maximum signal change when viewing the sun exoatmospherically is less than or equal to 2 to 3%.

Russell, James M., III↗

Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the trajectory of the tip leakage flow through the rotor passage. Further, these data extend previous measurements identifying a modulation of the tip leakage flow due to upstream stator wake propagation. Finally, a novel instrumentation technique has been implemented to measure pressures in the shrouded stator cavities. These data provide boundary conditions relating to the flow across the shrouded stator knife seal teeth. Moreover, the utilization of fast-response pressure sensors provides a new look at the time-resolved pressure field, leading to instantaneous differential pressures across the seal teeth. Ultimately, the data collected for this project represent a unique data set which contributes to build a better understanding of the tip leakage flow field and its associated loss mechanisms. These data will facilitate future engine design goals leading to small blade heights in the rear stages of high pressure compressors and aid in the development of new blade designs which are desensitized to the performance penalties attributed to rotor tip leakage flows.

Berdanier, Reid A.↗

Review of melt inclusions in lunar rocks: constraints on melt and mantle composition and magmatic processes

Mineral-hosted melt inclusions provide a window into magmatic processes and pre-eruptive liquid compositions. Because melt inclusions are small (typically < 100 µm), the study of lunar melt inclusions is enabled by advancements of microbeam instrumental techniques. In the 1970s immediately following the Apollo and Luna missions, major and minor oxide concentrations of lunar melt inclusions were measured using electron microprobes. The data were used to understand magma evolution, and they revealed the immiscibility of two silicate liquids in the late stage of lunar magma evolution. More recently, the development of secondary ion mass spectrometry as well as laser ablation–inductively coupled plasma–mass spectrometry has enabled the measurement of key volatile elements and other trace elements in lunar melt inclusions, down to about the 0.1 ppm level. The applications of these instruments have ushered in a new wave of lunar melt inclusion studies. Recent advances have gone hand in hand with improved understanding of post-entrapment loss of volatiles. These studies have provided deep insights into pre-eruptive volatiles in lunar basalts, the abundance of volatiles in the lunar mantle, the isotopic ratios of some volatile elements, and the partition of trace elements between host olivine and melt inclusions. The recent studies of lunar melt inclusions have played a critical role in establishing a new paradigm of a fairly wet Moon with about 100 ppm H2O in the bulk silicate Moon (rather than a “bone-dry” Moon) and have been instrumental in developing an improved understanding of the origin and evolution of the Moon.

Youxue Zhang↗

A study of the variability of ocean currents in the northwestern Atlantic using satellite altimetry

Altimeter data obtained from GEOS-3 during the three year period 1975-78 for a region of the western North Atlantic which includes a portion of the Gulf Stream system and part of the open ocean area of the subtropical gyre are analyzed by a new technique which utilizes all the points along the satellite tracks. The physical phenomenon studied are the time-variable but almost geostrophic currents, or mesoscale eddies, so that geoid errors contaminate the scientific signal minimally and the dynamical interpretation is direct. Results presented include the spatial distribution of geostrophic eddy kinetic energy and examples of a synoptic map of the eddy field (April 1977) and of a time series at a point. These results are compared to and synthesized with a diverse and select set of existing measurements and observations obtained in situ by a variety of instrumental techniques. The agreement is generally good, and the altimeter data analyzed provides new information on features in the map of mean eddy kinetic energy. The implications are that satellite altimetry will serve as a powerful quantitative tool in eddy current research and that even presently archived data contains further useful scientific information.

Robinson, A. R.↗

Novel Fiber Optic Sensing Arrays with Enhanced Sensitivity in Cryogenic Temperatures

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into the characteristics of cryogenic liquid storage. Optical fiber sensors that utilize fiber Bragg gratings are a viable option for temperature sensing in volatile liquid such as liquid oxygen because there is no risk of electrical sparking and no electromagnetic interference. The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (Edwards, California) has developed a novel, simple-to-fabricate fiber array sensor that has been tested and found to be three times more sensitive than typical fiber sensors under cryogenic condition (traditional fiber sensors can suffer from reduced sensitivity below 100 K). Cryogenic temperature monitoring using the NASA fiber optic sensing system is demonstrated in a simulated cryostatic condition, as well as in an elevated pressure environment under liquid nitrogen. Measurement accuracy is compared with traditional silicon diodes. Instrument installation, sensor characteristics, and experimental results are discussed in detail.

Hon Man Chan↗

A radioisotope - enabled reactive transport model for deep vadose zone carbon

In mountainous regions, which constitute the principle source of recharge to major rivers and regional aquifers, infiltration occurs through fractured, partially saturated, weathered bedrock that acts as a boundary layer between saturated aquifers and surface soil. Commonly this deep vadose zone (DVZ) is many meters thick, and yet its role in regulating the generation, retention and mobility of reactive solutes, including nutrients, contaminants and weathering products, is largely unknown. In particular, many of the key reactions that drive the formation of the weathered DVZ and the quality of water moving through it are redox processes, regulated by the availability of organic carbon and oxygen below the soil layer. The role of the DVZ is thus also poorly constrained in the context of carbon stocks and mobility, particularly in lithologies that are naturally high in organic carbon, such as shales. The overarching hypothesis of this study is that upland regions developed in geologic settings with abundant petrogenic carbon store and actively cycle carbon in the weathered DVZ below the soil and above the water table at rates that are significant and currently unconstrained. In order to quantify this cycling, the current study combines novel instrumentation techniques allowing new direct sampling of DVZ systems with advanced numerical reactive transport simulations of carbon transport and transformation. Critically, these simulations will explicitly treat the three isotopes of carbon (the abundant 12C, the stable rare 13C and the radioactive 14C) in a unified framework, thus clearly parsing between the contributions of modern surface derived carbon and lithologic carbon sources in integrated measurements of fluid and gas phase fluxes. This novel model capability will be applied to test the role of DVZ carbon cycling as a regulator of water quality and geological weathering in two complementary field sites both located in organic carbon rich shale lithologies. The first is the Eel River Critical Zone Observatory (ERCZO) in Mendocino County, California, and the second is the Lawrence Berkeley National Laboratory Watershed Function Scientific Focus Area (SFA) in the East River watershed, near Crested Butte, Colorado. At the ERCZO, a novel vadose zone monitoring system has been installed in a 20 m thick, partially saturated, weathered shale hillslope, and preliminary data already indicate substantial CO2 flux generated many meters below the soil surface. At the SFA field site, an instrumented hillslope transect indicates a more complex multi-dimensional fluid and solute transport regime, which will serve as a key test of the calibrated models. Collectively, this project will advance understanding of the cycling of carbon belowground and in relation to transport pathways across the poorly constrained DVZ characteristic of primary water recharge areas. The key product of this work will be enhanced isotope simulation capabilities that are robust and publicly available for application across a broad diversity of systems.

58 GEOSCIENCES↗

Demystifying Piecewise and Localized Scatter Correction Methods

Multiplicative scatter is a common source of noise in near-infrared spectroscopy and other related instrumental techniques. A wide variety of methods are commonly used for the correction of multiplicative scatter. However, the majority of such methods assume that the parameters that describe the scatter are constant throughout the measured spectrum, which is often not the case. This work investigates a family of methods that perform scatter correction using local regions of neighboring wavelengths in order to better account for wavelength-dependent scattering. The methods in question are piecewise standard normal variate, localized standard normal variate, piecewise multiplicative scatter correction, and localized multiplicative scatter correction. This work describes the theoretical and algorithmic foundations of the family of local region-based scatter correction methods and compares their application and optimization at a qualitative and quantitative level using several datasets.

NIR spectroscopy↗

Real-Time Health Monitoring for Gas Turbine Components Using Online Learning and High-Dimensional Data

Capital-intensive turbomachinery, such as gas turbines and combined cycle plants, are constantly being monitored for performance anomalies, faults, and physical degradation. Although these power-generating assets are equipped with hundreds of sensors, existing monitoring tools can only handle moderate-sized data. As a result, only a handful of aggregate metrics are used to monitor machine health. At the same time, developing advanced tools suitable for large datasets have been restricted by the lack of appropriate data. The objective of this proposal was to demonstrate a Big Data analytics framework for fault detection and diagnosis in gas turbine applications. We develop a predictive analytics framework methodology guided by these experimental data, industrial data from our collaborators, and physics-based models with engineering domain knowledge. Our analytics framework consists of four key components (1) a data curation process that addresses data storage, data quality assessments, and integrity checks, (2) a feature engineering component that utilizes statistical methods and transformation algorithms guided by physics-based models to extract high-fidelity fault features that can be leveraged for fault detection and classifying fault severities, (3) a Machine Learning-based fault detection and diagnostics algorithms for detecting operational and hardware faults in the combustion and the turbines section. We utilize two industry-class gas turbine component test rigs to generate first of its kind data for critical gas turbine faults with varying severity levels. Advanced gas turbine test facilities will be interrogated using state-of-the-art instrumentation techniques to build fault signatures and data trends for key combustor and turbine faults. Data generated from a combustor test rig (Georgia Tech) and a turbine test rig (Penn State) during both normal operation and with seeded faults serve as the basis for the Big Data sets. The test conditions in the two test facilities include common, critical events that occur in the operation. Utilizing the combustor test rig, we examine two common combustor faults: lean blowout and centerbody degradation. For the turbine section we develop analytic models for monitoring cooling faults in the gas turbine

03 NATURAL GAS↗

Cb-1zr Pumped Sodium Loop

Cb-1Zr pumped sodium loop tests to evaluate loop components, EM pump, pressure transducers, and instrumentation techniques

Hoffman, E. E.↗

Bragg crystal spectrometer for HEAO-B X-ray astronomy experiment

The X-ray astronomy experiment for the HEAO mission is described. The instrument to be flown on the satellite consists of two Bragg crystal spectrometers designed to make measurements with high spectral resolution in the energy range from 0.1 to 10 keV. No sharp spectroscopic features were detected directly in X-ray astronomy except emission lines in the sun; therefore, the objectives and design criteria of this instrument are based on the theoretical models of the different types of extra solar X-ray sources. From the point of view of instrumental techniques it is convenient to divide these into point or stellar sources, whose radiation is parallel, and diffuse sources, and to consider the possible spectral features in each type.

Angel, J. R. P.↗