At least 91 records · Page 5

Microelectromechanical System (MEMS) Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) using a Stirling thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface is being developed at the NASA Glenn Research Center to meet this need. The device can be used strictly in the cooling mode or can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly employ techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces, limited failure modes, and minimal induced vibration. The MEMS cooler has potential applications across a broad range of industries such as the biomedical, computer, automotive, and aerospace industries. The basic capabilities it provides can be categorized into four key areas: 1) Extended environmental temperature range in harsh environments; 2) Lower operating temperatures for electronics and other components; 3) Precision spatial and temporal thermal control for temperature-sensitive devices; and 4) The enabling of microsystem devices that require active cooling and/or temperature control. The rapidly expanding capabilities of semiconductor processing in general, and microsystems packaging in particular, present a new opportunity to extend Stirling-cycle cooling to the MEMS domain. The comparatively high capacity and efficiency possible with a MEMS Stirling cooler provides a level of active cooling that is impossible at the microscale with current state-of-the-art techniques. The MEMS cooler technology builds on decades of research at Glenn on Stirling-cycle machines, and capitalizes on Glenn s emerging microsystems capabilities.

Beach, Duane E.↗

Controlled Temperature Gradient Improves Freezing Alloy

Controlled gradient of temperature in advancing zone of solidification increases fatigue life of directionally solidified nickel-base superalloy. Improved solidification process eliminates, reduces, or controls microstructure of deleterious brittle phases, including carbides and gamma/gamma prime eutectic. Also reduces microsegregation and makes discrete carbides (if present) become fine and blocky. Expected to improve properties of other alloys, of both directionally-solidified polycrystalline and single-crystal forms.

Schmidt, Deborah↗

Solid-state Distributed Temperature Control for International Space Station

A newly developed solid-state temperature controller will offer greater flexibility in the thermal control of aerospace vehicle structures. A status of the hardware development along with its implementation on the Multi- Purpose Logistics Module will be provided. Numerous advantages of the device will also be discussed with regards to current and future flight vehicle implementations.

Holladay, Jon B.↗

Temperature-controlled quartz crystal microbalance measurements on Space Transport System (STS-2)

The purpose of the Temperature-Controlled Quartz Crystal Microbalance (TQCM) system on STS-2 was to measure condensible molecular flux in the payload bay of the Space Shuttle as a function of temperature, direction, and time. Five quartz crystal microbalance sensors were located in the IECM to measure molecular adsorption in each of the Orbiter axes, +X (fore), -X (aft), +Y (starboard), -Y (port), and -Z (up, perpendicular to payload bay). The temperature of each sensor was controlled by a thermoelectric device so contamination could be measured as a function of four preset temperatures: +30, 0, -30, and -60 C. When orbital altitude was reached, the TQCM sensors began their orbital measuring cycle routine. The sensors were commanded to 80 C for 30 min, which was used as an initial clean-up. They were then stepped through a program of 2-nr collection periods at each temperature with a 30-min, 80 C period between each collection period. The collection periods progressed in descending order from +30 to -60 C and, then the cycle was repeated. Since the STS-2 orbital phase lasted approximately 53 hrs, the TQCM system completed four cycles and was in the fifth when the mission was terminated.

Fountain, J. A.↗

Fault-Tolerant, Multiple-Zone Temperature Control

A computer program has been written as an essential part of an electronic temperature control system for a spaceborne instrument that contains several zones. The system was developed because the temperature and the rate of change of temperature in each zone are required to be maintained to within limits that amount to degrees of precision thought to be unattainable by use of simple bimetallic thermostats. The software collects temperature readings from six platinum resistance thermometers, calculates temperature errors from the readings, and implements a proportional + integral + derivative (PID) control algorithm that adjusts heater power levels. The software accepts, via a serial port, commands to change its operational parameters. The software attempts to detect and mitigate a host of potential faults. It is robust to many kinds of faults in that it can maintain PID control in the presence of those faults.

Granger, James↗

Vapor-modulated heat pipe for improved temperature control

Dryout induced by vapor throttling makes control of equipment temperature less dependent on variations in sink environment. Mechanism controls flow of vapor in heat pipe by using valve in return path to build difference in pressure and also difference in saturation temperature of the vapor. In steady state, valve closes just enough to produce partial dryout that achieves required temperature drop.

Edwards, D. K.↗

Temperature control simulation for a microwave transmitter cooling system

The thermal performance of a temperature control system for the antenna microwave transmitter (klystron tube) of the Deep Space Network antenna tracking system is discussed. In particular the mathematical model is presented along with the details of a computer program which is written for the system simulation and the performance parameterization. Analytical expressions are presented.

Yung, C. S.↗

Some Sources of Contaminants in the Shuttle Bay Measured with Temperature-Controlled Quartz Crystal Microbalances (TQCM)

The sources of molecular deposits on a Temperature-Controlled Quartz Crystal Microbalance (TQCM) attached to the shuttle bay wall at some distance from the payload and pointing out of the bay have been investigated. Explored as possible sources are: (1) the outgassing of the shuttle tiles treated with the water proofing di-methyl-ethoxy-silane (DMES) compound, scattered back by the ambient molecules into the bay; (2) The ambient scattered return flux of the outgassing, from the RTV 560 silicone which is used as the adhesive for the tiles; (3) the ambient scattered return flux of the payload outgassing; (4) the return C, flux from outgassing source originating near, below, or adjacent to the package containing the TQCM; and (5) the self-scattering of venting plumes and outgassing above the monitor package depositing on the TQCM. In all of these sources, the magnitudes of the outgassing, of the leakage rates, and venting had to be estimated in the absence of data. The resulting analyses which can be useful for similar investigations, indicates that the outgassin- from the tiles, the RTV, the payloads, or the shuttle may not have been the sources of the deposit (about 1 micro g/cm(sup 2) during a the period from bay door opening and payload release from the bay). It appears more probable that the origin is the self- and/or ambient-scattered return fluxes originating near, below, or internal to the monitor package.

Scialdone, John J.↗

Programmable temperature control system for biological materials

A system was constructed which allows programmable temperature-time control for a 5 cu cm sample volume of arbitrary biological material. The system also measures the parameters necessary for the determination of the sample volume specific heat and thermal conductivity as a function of temperature, and provides a detailed measurement of the temperature during phase change and a means of calculating the heat of the phase change. Steady-state and dynamic temperature control is obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container is totally immersed into a cold heat sink. Using a mixture of dry ice and alcohol at 79 C, the sample volume can be controlled from +40 to -60 C at rates from steady state to + or - 65 C/min. Steady-state temperature precision is better than 0.2 C, while the dynamic capability depends on the temperature rate of change as well as the mass of both the sample and the container.

Anselmo, V. J.↗

Heat pipes for spacecraft temperature control: Their usefulness and limitations

Heat pipes are used in spacecraft to equalize the temperature of structures and maintain temperature control of electronic components. Information is provided for a designer on: (1) a typical mounting technique, (2) choices available in wick geometries and fluids, (3) tests involved in flight-qualifying the design, and (4) heat pipe limitations. An evaluation of several heat pipe designs showed that the behavior of heat pipes at room temperature does not necessarily correlate with the classic equations used to predict their performance. They are sensitive to such parameters as temperature, fluid inventory, orientation, and noncondensable gases.

Ollendorf, S.↗

Definition study for temperature control in advanced protein crystal growth

Some of the technical requirements for an expedient application of temperature control to advanced protein crystal growth activities are defined. Lysozome was used to study the effects of temperature ramping and temperature gradients for nucleation/dissolution and consecutive growth of sizable crystals and, to determine a prototype temperature program. The solubility study was conducted using equine serum albumin (ESA) which is an extremely stable, clinically important protein due to its capability to bind and transport many different small ions and molecules.

Nyce, Thomas A.↗

Controlled-Temperature Hot-Air Gun

Materials that find applications in wind tunnels first tested in laboratory. Hot-Air Gun differs from commercial units in that flow rate and temperature monitored and controlled. With typical compressed-airsupply pressure of 25 to 38 psi (170 to 260 kPa), flow rate and maximum temperature are 34 stdft3/min (0.96 stdm3/min) and 1,090 degrees F (590 degrees C), respectively. Resembling elaborate but carefully regulated hot-air gun, setup used to apply blasts of air temperatures above 1,500 degrees F (815 degrees C) to test specimens.