Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Classifying Multi-Model Wheat Yield Impact Response Surfaces Showing Sensitivity to Temperature and Precipitation Change

Crop growth simulation models can differ greatly in their treatment of key processes and hence in their response to environmental conditions. Here, we used an ensemble of 26 process-based wheat models applied at sites across a European transect to compare their sensitivity to changes in temperature (minus 2 to plus 9 degrees Centigrade) and precipitation (minus 50 to plus 50 percent). Model results were analysed by plotting them as impact response surfaces (IRSs), classifying the IRS patterns of individual model simulations, describing these classes and analysing factors that may explain the major differences in model responses. The model ensemble was used to simulate yields of winter and spring wheat at four sites in Finland, Germany and Spain. Results were plotted as IRSs that show changes in yields relative to the baseline with respect to temperature and precipitation. IRSs of 30-year means and selected extreme years were classified using two approaches describing their pattern. The expert diagnostic approach (EDA) combines two aspects of IRS patterns: location of the maximum yield (nine classes) and strength of the yield response with respect to climate (four classes), resulting in a total of 36 combined classes defined using criteria pre-specified by experts. The statistical diagnostic approach (SDA) groups IRSs by comparing their pattern and magnitude, without attempting to interpret these features. It applies a hierarchical clustering method, grouping response patterns using a distance metric that combines the spatial correlation and Euclidian distance between IRS pairs. The two approaches were used to investigate whether different patterns of yield response could be related to different properties of the crop models, specifically their genealogy, calibration and process description. Although no single model property across a large model ensemble was found to explain the integrated yield response to temperature and precipitation perturbations, the application of the EDA and SDA approaches revealed their capability to distinguish: (i) stronger yield responses to precipitation for winter wheat than spring wheat; (ii) differing strengths of response to climate changes for years with anomalous weather conditions compared to period-average conditions; (iii) the influence of site conditions on yield patterns; (iv) similarities in IRS patterns among models with related genealogy; (v) similarities in IRS patterns for models with simpler process descriptions of root growth and water uptake compared to those with more complex descriptions; and (vi) a closer correspondence of IRS patterns in models using partitioning schemes to represent yield formation than in those using a harvest index. Such results can inform future crop modelling studies that seek to exploit the diversity of multi-model ensembles, by distinguishing ensemble members that span a wide range of responses as well as those that display implausible behaviour or strong mutual similarities.

Classification; Climate change; Crop model; Ensemb↗

Sensitivity of Temperature Profiles Retrieved from Mars Global Surveyor Thermal Emission Spectrometer (MGS/TES) Observations to the GSFC Synthetic Mars Model Atmosphere

Part of the task of interpreting IR spectral features observed by MGS/TES due to surface minerals requires distinguishing those IR signatures from atmospheric signatures of gas and dust. Surface-atmosphere separation for MGS/TES depends on knowledge of the retrieved temperature profile. In turn, the temperature retrieval Erom the observed data depends on molecular parameters including 15 micron CO2 line shape or line intensities which contribute to defining the Mars synthetic radiative transfer model. Using a simple isothermal, homogeneous single layer model of Pinnock and Shine, we find the ratio of (the error in degrees Kelvin of the retrieved temperature profile) to (the percentage error in the absorption coefficient) (deg K/percent) to be 0.4 at 200K. This ratio at 150K and 250K is 0.2 and 0.6, respectively. A more refined model, incorporating observed MGS/TES retrieved temperature profiles, the TES instrumental resolution and the most recent molecular modelling, will yield an improved knowledge of this error sensitivity. We present results of such a sensitivity study to determine the dependence of temperature profiles inverted from MGS/TES on these and other molecular parameters. This work was supported in part by NASA's Mars Data Analysis Program.

Maguire, William C.↗

A minor respiratory process with major global implications: is atmospheric methane oxidation in tree stems driven by stem respiration rather than microbial methanotrophy?

Tree stem surfaces are widely recognized as sites of carbon dioxide (CO₂) efflux and oxygen (O₂) influx, reflecting the dynamics of aerobic respiration of photosynthate substrates, such as sugars, delivered via the phloem. Stems are also largely considered passive conduits for methane (CH₄) produced in anoxic soils via microbial methanogenesis, where CH₄ is thought to be transported upward through the transpiration stream and/or diffusion and emitted through stem surfaces and the canopy. However, recent observations from dynamic stem chambers suggest that stems may also act as active sinks for atmospheric CH₄. Despite these findings, the extent and drivers of stem CH₄ consumption remain poorly characterized across biomes, species, and environmental gradients, and its quantitative relationship to stem respiration has not been established. Moreover, previous studies captured only snapshot fluxes, leaving diurnal patterns of CH₄ exchange uncharacterized. Here, we address these limitations by combining real-time measurements of stem CH₄ and O₂ uptake under ambient conditions in a California cherry tree, using a dynamic stem gas exchange system with three chambers receiving a continuous flow of ambient air and automated chamber and reference air sampling every 10 min. Our results confirm that stems of upland trees can actively consume both atmospheric CH₄ and O₂, but with decreasing temperature sensitivity as daily temperatures increase. Early mornings were marked by rapid influxes of both gases, followed by declining uptake as temperatures rose further. Methane uptake was tightly coupled with O₂ influx and represented a minor (0.012% ± 0.002%) fraction of stem respiratory activity, as determined by concurrent O₂ uptake. These findings suggest that while atmospheric CH₄ oxidation is a minor respiratory process in stems, it is strongly linked with stem physiological activity. This challenges the current assumption that terrestrial CH₄ uptake is driven solely by microbial methanotrophy and raises the possibility that living stem tissues may contribute to CH₄ oxidation through an as-yet-unidentified plant-based mechanism.

Atmospheric greenhouse gases↗

Water-vapor absorption line measurements in the 940-nm band by using a Raman-shifted dye laser

We report water-vapor absorption line measurements that are made by using the first Stokes radiation (930-982 nm) with HWHM 0.015/cm generated by a narrow-linewidth, tunable dye laser. Forty-five absorption line strengths are measured with an uncertainty of 6 percent and among them are fourteen strong lines that are compared with previous measurements for the assessment of spectral purity of the light source. Thirty air-broadened linewidths are measured with 8 percent uncertainty at ambient atmospheric pressure with an average of 0.101/cm. The lines are selected for the purpose of temperature-sensitive or temperature-insensitive lidar measurements. Results for these line strengths and linewidths are corrected for broadband radiation and finite laser linewidth broadening effects and compared with the high-resolution transmission molecular absorption.

Chu, Zhiping↗

Spectroscopic determination of the phase composition and temperature of nitrogen ice on Triton

Laboratory spectra of the first overtone band (2.1480 microns, 4655.4 reciprocal cm) of solid nitrogen show additional structure at 2.1618 microns (4625.8 reciprocal cm) over a limited temperature range. The spectrum of Neptune's satellite Triton shows the nitrogen overtone band as well as the temperature-sensitive component. The temperature dependence of this band may be used in conjunction with ground-based observations of Triton as an independent means of determining the temperature of surface deposits of nitrogen ice. The surface temperature of Triton is found to be 38.0 +2.0 or -1.0 K, in agreement with previous temperature estimates and measurements. There is no spectral evidence for the presence of alpha-nitrogen on Triton's surface, indicating that there is less than 10 percent carbon monoxide in solid solution with the nitrogen on the surface.

Tryka, Kimberly A.↗

NASA Ultra-Sensitive Miniature Accelerometer

Using micro-machined silicon technology, an ultra-sensitive miniature acce.,rometer can be constructed which meets the requirements for microgravity experiments in the space environment.Such an accelerometer will have a full scale sensitivity of 1C2 g a resolution of lC8 g, low cross axis sensitivity, and low temperature sensitivity. Mass of the device is approximately five grams and its footprint is 2 cm x 2 cm. Innovative features of the accelerometer, which are patented, are: electrostatic caging to withstand handling shock up to 150 g, in-situ calibration, in situ performance characterization, and both static and dynamic compensation. The transducer operates on a force balance principle wherein the displacement of the proof mass is monitored by measuring tunneling electron current flow between a conductive tip, and a fixed platen. The four major parts of the accelerometer are tip die, incorporating the tunneling tip and four field plates for controlling pitch and roll of the proof mass; two proof mass dies, attached to the surrounding frame by sets of four leg" springs; and a force plate die. The four parts are fuse-bonded into a complete assembly. External electrical connections are made at bond pads on the front surface of the force plate die. Materials and processes used in the construction of the transducer are compatible with volume production.

Zavracky, Paul M.↗

The Mass of the Classical Cepheid S Mus

A FUSE spectrum of the hot companion of the Cepheid S Mus has been obtained, reduced and analysed. Since the determination of the temperature of S Mus B is the prime goal of this program, we have identified two regions in the spectrum which are temperature sensitive in the temperature range of the companion, but which are not overly affected by molecular hydrogen absorption. From comparison of the spectrum with spectra of stars of known temperature, we have determined the temperature of the companion to be 17,000 K. From this a mass has been inferred. Combining this mass with the orbital velocity ratio of the Cepheid and the companion (from the ground-based Cepheid orbit, and HST GHRS echelle observations), the mass of the Cepheid is determined to be 6.0 =/- 0.4 solar masses. The results have been presented at a conference (conference proceedings in press--see attachment).

Sonneborn, George↗

Characterization of Fluorescent Polystyrene Microspheres for Advanced Flow Diagnostics

Fluorescent dye-doped polystyrene latex microspheres (PSLs) are being developed for velocimetry and scalar measurements in variable property flows. Two organic dyes, Rhodamine B (RhB) and dichlorofluorescence (DCF), are examined to assess laser-induced fluorescence (LIF) properties for flow imaging applications and single-shot temperature measurements. A major interest in the current research is the application of safe dyes, thus DCF is of particular interest, while RhB is used as a benchmark. Success is demonstrated for single-point laser Doppler velocimetry (LDV) and also imaging fluorescence, excited via a continuous wave 2 W laser beam, for exposures down to 10 ms. In contrast, when exciting with a pulsed Nd:YAG laser at 200 mJ/pulse, no fluorescence was detected, even when integrating tens of pulses. We show that this is due to saturation of the LIF signal at relatively low excitation intensities, 4-5 orders of magnitude lower than the pulsed laser intensity. A two-band LIF technique is applied in a heated jet, indicating that the technique effectively removes interfering inputs such as particle diameter variation. Temperature measurement uncertainties are estimated based upon the variance measured for the two-band LIF intensity ratio and the achievable dye temperature sensitivity, indicating that particles developed to date may provide about +/-12.5 C precision, while future improvements in dye temperature sensitivity and signal quality may enable single-shot temperature measurements with sub-degree precision.

Maisto, Pietro M. F.↗

NASA Ultra-Sensitive Miniature Accelerometer

Using micro-machined silicon technology, an ultra-sensitive miniature accelerometer can be constructed which meets the requirements for microgravity experiments in the space environment. Such an accelerometer will have a full scale sensitivity of 10 -2 g, a resolution of 10 -8 g, low cross-axis sensitivity, and low temperature sensitivity. Mass of the device is approximately five grams and its footprint is 2 cm x 2 cm.

miniature↗

Development of Luminescence Lifetime-Based Surface Temperature Mapping for Environmental Barrier Coatings

Luminescence lifetime-based temperature mapping for thermal barrier coatings (TBCs) has been previously demonstrated up to temperatures approaching 1200 °C. Advantages of this method include insensitivities to reflected radiation and emissivity uncertainties. Because of a push towards greater efficiency turbine engine operation using higher turbine inlet temperatures, there is an ongoing movement from TBC-coated superalloy turbine engine components to SiC/SiC ceramic matrix composite components protected by environmental barrier coatings (EBCs). The useful application of luminescence lifetime-based temperature mapping to EBCs requires a significant increase in high temperature capability from below 1200 °C up into the 1300 to 1500 °C temperature range where the much higher background thermal radiation is a challenging issue. In addition, the luminescing sensing layer must exhibit thermochemical compatibility with the EBC. To meet these requirements, Er-doped Y 2 SiO 5 was selected as the luminescing sensor layer material both for its enhanced temperature sensitivity above 1300 °C and its compatibility with rare-earth disilicate EBC topcoats. Both localized spot temperature measurements as well as luminescence lifetime imaging-based temperature mapping were demonstrated up to 1560 °C for Er-doped Y 2 SiO 5 disks. In addition, temperature mapping capability was demonstrated from a 15 µm thick Er-doped Y 2 SiO 5 layer at the surface of a Sc 2 Si 2 O 7 based EBC topcoat. Both localized spot and temperature mapping by luminescence lifetime imaging were demonstrated up to 1380 °C (upper temperature limit of this slurry-based layered EBC) with excellent suppression of background thermal radiation and no degradation of the Er-doped Y 2 SiO 5 temperature sensing surface layer. The source of the novel enhanced temperature sensitivity above 1300 °C will be discussed as well as a path towards compatibility between sensing layer and EBC topcoat to higher temperatures.

temperature measurement↗

The physics of the environmental sensitivity of rubidium gas cell atomic frequency standards

Environmental sensitivity is often the most significant limitation to the practical stability of rubidium frequency standards (RFS). For example, temperature sensitivity can cause a rapid frequency change of several parts in 10(exp 10) for a tactical RFS that has an aging of only 1 times 10(exp -11)/month. Other important environmental factors are barometric pressure, vibration, magnetic field, and nuclear radiation. The physical mechanisms that lie behind these environmental sensitivities are considered. These physical mechanisms are related to the performance of actual rubidium frequency standards. For the user of these devices, a better knowledge of the causes for Rb clock instability will aid in their testing and proper application. For the time frequency specialist, a review of these factors may prove useful toward improving RFS design. Some of the RFS environmental sensitivities are due to simple physical mechanisms like the effect of dc magnetic field on the Rb hyperfine resonance frequency. For these, an analysis can be based on physical principles and straightforward design factors. Other environment factors, like temperature sensitivity, are more complex combinations of many effects, both physical and practical, and the analysis often takes the form of an error budget with large unit-to-unit variations. Today's rubidium frequency standards span a wide performance range from small, inexpensive units with pp 10(exp 10) error budgets to larger, higher performance versions offering pp 10(exp 10) stabilities. For both extremes, however, environmental sensitivity can be the most significant performance limitation. Why this is the case and how to make improvements are discussed.

Riley, William J.↗

Effects of Coating and Diametric Load on Fiber Bragg Gratings as Cryogenic Temperature Sensors

Cryogenic temperature sensing was demonstrated using pressurized fiber Bragg gratings (PFBGs) with polymer coating of various thicknesses. The PFBG was obtained by applying a small diametric load to a regular fiber Bragg grating (FBG). The Bragg wavelengths of FBGs and PFBG were measured at temperatures from 295 K to 4.2 K. The temperature sensitivities of the FBGs were increased by the polymer coating. A physical model was developed to relate the Bragg wavelength shifts to the thermal expansion coefficients, Young's moduli, and thicknesses of the coating polymers. When a diametric load of no more than 15 N was applied to a FBG, a pressure-induced transition occurred at 200 K during the cooling cycle. The pressure induced transition yielded PFBG temperature sensitivities three times greater than conventional FBGs for temperatures ranging from 80 to 200 K, and ten times greater than conventional fibers for temperatures below 80 K. PFBGs were found to produce an increased Bragg wavelength shift of 2.2 nm compared to conventional FBGs over the temperature range of 4.2 to 300 K. This effect was independent of coating thickness and attributed to the change of the fiber thermo-optic coefficient.

Wu, meng-Chou↗

The Role of Sea Ice in 2 x CO2 Climate Model Sensitivity: Hemispheric Dependencies - Part 2

How sensitive are doubled CO2 simulations to GCM control-run sea ice thickness and extent? This issue is examined in a series of 10 control-run simulations with different sea ice and corresponding doubled CO2 simulations. Results show that with increased control-run sea ice coverage in the Southern Hemisphere, temperature sensitivity with climate change is enhanced, while there is little effect on temperature sensitivity of (reasonable) variations in control-run sea ice thickness. In the Northern Hemisphere the situation is reversed: sea ice thickness is the key parameter, while (reasonable) variations in control-run sea ice coverage are of less importance. In both cases, the quantity of sea ice that can be removed in the warmer climate is the determining factor. Overall, the Southern Hemisphere sea ice coverage change had a larger impact on global temperature, because Northern Hemisphere sea ice was sufficiently thick to limit its response to doubled CO2, and sea ice changes generally occurred at higher latitudes, reducing the sea ice-albedo feedback. In both these experiments and earlier ones in which sea ice was not allowed to change, the model displayed a sensitivity of -0.02 C global warming per percent change in Southern Hemisphere sea ice coverage.

Rind, D.↗

The effect of low temperature on poly(3-methyl- N -vinylcaprolactam)- b -poly( N -vinylpyrrolidone) diblock copolymer nanovesicles assembled from all-aqueous media

Nanosized polymeric vesicles (polymersomes) self-assembled from double hydrophilic copolymers of poly(3-methyl-N-vinylcaprolactam) n -b-poly(N-vinylpyrrolidone) m (PMVC n -b-PVPON m ) using all aqueous media are a promising platform for biomedical applications, because of their superior stability over liposomes in vivo and high loading capacity. Herein, we explored the temperature-sensitive behavior of PMVC 58 -b-PVPON 65 vesicles using transmission electron microscopy (TEM), dynamic light scattering (DLS), atomic force microscopy (AFM), and small-angle neutron scattering (SANS) in response to lowering the solution temperature from 37 to 25, 20, 14 and 4 °C. The copolymer vesicles with an average size of 350 nm at 37 °C were assembled from the diblock copolymer dissolved in aqueous solution at 4 °C. We show that while the polymersome's size gradually decreases upon the temperature decrease from 37 to 4 °C, the average shell thickness increases from 17 nm to 25 nm, respectively. SANS study revealed that the PMVC 58 -b-PVPON 65 vesicle undergoes a gradual structure evolution from a dense-shell vesicle at 37–25 °C to a highly-hydrated shell vesicle at 20–14 °C to molecular chain aggregates at 4 °C. From SANS contrast matching study, this vesicle behavior is found to be driven by the gradual rehydration of PMVC block at 37–14 °C. The shell hydration at 20–14 °C also correlated with the 4.4-fold decrease in the relative fluorescence intensity from vesicle-encapsulated fluorescent dye, indicating ~80% of the dye release within 12 hours after the vesicle exposure to 14 °C. No significant (<5%) dye release was observed for the vesicle solutions at 37–20 °C, indicating excellent cargo retention inside the vesicles. Our study provides new fundamental insights on temperature-sensitive polymer vesicles and demonstrates that the copolymer assembly into polymersomes can be achieved by decreasing a copolymer aqueous solution temperature below 14 °C followed by solution exposure to ≥20 °C. This type of all-aqueous assembly, instead of nanoprecipitation from organic solvents or solvent exchange, can be highly desirable for encapsulating a wide range of biological molecules, including proteins, peptides, and nucleic acids, into stable polymer vesicles without a need for organic solvents for dissolution of the copolymers that are amphiphilic at physiologically relevant temperatures of 20–37 °C.

36 MATERIALS SCIENCE↗

Possibility to sound the atmospheric ozone by a radiosonde equipped with two temperature sensors, sensitive and non-sensitive to the long wave radiation

The sensitiveness of white coated thermistor sensors and non-sensitiveness of the gold coated over white thermistor sensors (which have been manufactured by a vacuum evaporation process) to long wave radiation were ascertained by some simple experiments in-room and also by analyses of some results of experimental soundings. From results of analyses on the temperature discrepancies caused by long wave radiation, the possibility to sound the atmospheric ozone partial pressure by a radiosonde equipped with two kinds of sensors, sensitive and non-sensitive to the long wave radiation was suggested, and the test results of the newly developed software for the deduction of ozone partial pressure in upper layers was also shown. However, it was found that the following is the necessary condition to realize the purpose. The sounding should be made by a radiosonde equipped with three sensors, instead of two, one being non-sensitive to the long wave radiation perfectly, and the other two also non-sensitive partially to the downward one, with two different angles of exposure upward. It is essential for the realization of the purpose to get two different values of temperature discrepancies simultaneously observed by the three sensors mentioned above and to avoid the troublesome effects of the upward long wave radiation.

Kitaoka, T.↗

Temperature diagnostic line ratios of Fe XVII

Based on extensive calculations of the excitation rates of Fe XVII, four temperature-sensitive line ratios are investigated, paying special attention to the contribution of resonances to the excitation rates and to the contributions of dielectronic recombination satellites to the observed line intensities. The predictions are compared to FPCS observations of Puppis A and to Solar Maximum Mission (SMM) and SOLEX observations of the sun. Temperature-sensitive line ratios are also computed for emitting gas covering a broad temperature range. It is found that each ratio yields a differently weighted average for the temperature and that this accounts for some apparent discrepancies between the theoretical ratios and solar observations. The effects of this weighting on the Fe XVII temperature diagnostics and on the analogous Fe XXIV/Fe XXV satellite line temperature diagnostics are discussed.

Raymond, J. C.↗

Borescope Imaging System Developed for Luminescent Paint Measurements

The luminescent paint measurement technique utilizes a coating that is applied to a test article, allowing the air pressure or temperature of a surface to be measured. These coatings are commonly referred to as pressure- or temperature-sensitive paints. These paints are excited with short wavelength light and emit light at a longer wavelength. By measuring the change of intensity of the emitted light from a known reference condition, researchers can determine the pressure or temperature. The technique of measuring full-field surface pressure and temperatures using luminescent coatings has required a direct line-of-sight from the camera to the surface under study. In most experiments that have used pressure-or temperature-sensitive paints, the test surfaces are mounted so it is straightforward to position the camera and excitation source. In other cases, the luxury of having optical access through a window is not available or even possible. We developed a borescope imaging system to gain optical access in these confined areas. The commercially available 10-mm-diameter rigid borescope contains relay optics to transmit the detected light to a charge-coupled device (CCD) camera as well as an internal fiber-optic light guide to provide the excitation source for the luminescent coatings. The coupled light source can be continuous for the intensity method but also can be pulsed or have a variable intensity for a newer method of acquisition that measures the decay or phase lag of the emitted light. This type of borescope focuses the image directly on the CCD chip without using a fiber-optic relay, eliminating unwanted honeycomb patterns that are typical of fiber-optic type borescopes. This produces images of much higher clarity and uniformity, which are critical for acquiring accurate measurements from the luminescent coatings.

Bencic, Timothy J.↗

Autonomous Aerosol and Plasma Co‐Jet Printing of Metallic Devices at Ambient Temperature

Abstract Additive manufacturing of metallic materials holds the potential to revolutionize the fabrication of functional devices unattainable via traditional methods. Despite recent advancements, printing metallic materials typically requires thermal processing at elevated temperatures to form dense structures with desired properties, which presents a major challenge for direct printing and integration with temperature‐sensitive materials. Herein, a unique co‐jet printing (CJP) method is reported integrating an aerosol jet and a non‐thermal, atmospheric pressure plasma jet to enable concurrent aerosol deposition of metal nanoparticle inks and in situ sintering at ambient temperature. A machine learning algorithm is integrated with the CJP to perform real‐time defect detection and autonomous correction, enhancing the yield of printed films with high electrical conductivity from 44% to 94%. Concurrent printing and sintering eliminate the need for post‐printing processing, reducing the overall manufacturing time by multiple folds depending on product size. CJP enables direct printing of functional devices on a variety of temperature‐sensitive materials including biological materials. Direct printing of hydration sensors on living plant leaves is demonstrated for long‐duration monitoring of hydration level in the plant. The versatile CJP method opens tremendous opportunities to harmoniously integrate abiotic and biotic materials for emerging applications in wearable/implantable devices and biohybrid systems.

Du, Yipu [Department of Aerospace and Mechanical E↗