Search NASA⌕ Search

SEARCH · Search NASA

Results for “test harness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electromagnetic Compatibility Design, Implementation and Test of the SMAP Spacecraft to Meet Stringent L-Band Radiated Emissions Requirements

This paper describes the electromagnetic compatibility (EMC) requirements on the NASA SMAP mission, the implementation of EMC best practices at various levels of development in system level cabling harnesses and subsystems packaging, and the testing and results of flight hardware at the subsystem and spacecraft system levels.

Huang, Chi-Chien Nelson↗

An objective inter-comparison of trash mark constellations generated by manual and automated detection methods

Trash marks are unintentional markings observed on printed, scanned, or photocopied documents that result from permanent defects or transient material in office machines and can be used for source attribution of questioned documents. Trash mark examinations have been in use in forensic laboratories for decades, yet the method remains relatively untested and relies on training, experience, and anecdotal information to support its validity. Herein this study generated and harnessed objective data to empirically test one of the foundational theories for assessing the origin of photocopied documents: provided trash marks are present in sufficient quantity and/or quality, no two machines will exhibit a constellation of trash marks that is indistinguishable from another. In this project, objective trash mark location and size data was generated for 50 known photocopiers using both a traditional and a novel, automated method. Inter-machine comparisons were conducted using a novel variant of the Hausdorff distance algorithm to generate a quantitative assessment of how similar or different the 2450 pairs of trash mark constellations were from one another. This study found that each of the machines bearing one or more trash marks exhibited objective differences in their trash mark constellations, ultimately providing support for the tested hypothesis

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of simulated weightlessness on the immune system in rats

Rats suspended in a model system designed to simulate many aspects of weightlessness were immunized with sheep red blood cells. Parameters measured on these and control rats included titers of anti-sheep red blood cell antibodies, serum immunoglobulin levels, spleen and thymus weights, hematocrits, and leukocyte differential counts on peripheral blood. No significant differences were found between test and weight-bearing, harnessed controls; however, the thymuses of animals in both these groups were significantly smaller than untreated cage controls. The lack of an effect of simulated weightlessness on the immune system is an interesting result, and its significance is discussed.

Caren, L. D.↗

Iosipescu shear properties of graphite fabric/epoxy composite laminates

The Iosipescu shear test method is used to measure the in-plane and interlaminar shear properties of four T300 graphite fabric/934 epoxy composite materials. Different weave geometries tested include an Oxford weave, a 5-harness satin weave, an 8-harness satin weave, and a plain weave with auxiliary warp yarns. Both orthogonal and quasi-isotropic layup laminates were tested. In-plane and interlaminar shear properties are obtained for laminates of all four fabric types. Overall, little difference in shear properties attributable to the fabric weave pattern is observed. The auxiliary warp material is significantly weaker and less stiff in interlaminar shear parallel to its fill direction. A conventional strain gage extensometer is modified to measure shear strains for use with the Iosipescu shear test. While preliminary results are encouraging, several design iterations failed to produce a reliable shear transducer prototype. Strain gages are still the most reliable shear strain transducers for use with this test method.

Walrath, D. E.↗

In-plane and interlaminar Iosipescu shear properties of various graphite fabric/epoxy laminates

The Iosipescu shear test method was used to measure the in-plane and interlaminar shear properties of four T300 graphite fabric/Fiberite 934 epoxy composite materials. Weave geometries tested included an Oxford weave, a 5-harness satin weave, an 8-harness satin weave, and a plain weave with auxiliary warp yarns. Both orthogonal and quasi-isotropic layup laminates were tested. In-plane and interlaminar shear properties were obtained for laminates of all four fabric types. Overall, few differences in shear properties attributable to the fabric weave pattern were observed. However, the auxiliary warp material was significantly weaker and less stiff in interlaminar shear parallel to its fill direction.

Adams, Donald F.↗

Biomechanical Modeling of Split-leg Squat and Heel Raise on the Hybrid Ultimate Lifting Kit (HULK)

Long duration space travel will expose astronauts to extended periods of reduced gravity. Since gravity is not present to aid loading, astronauts will use resistive and aerobic exercise regimes for the duration of the space flight to minimize the loss of bone density, muscle mass and aerobic capacity that occurs during exposure to a reduced gravity environment. Unlike the International Space Station (ISS), the area available for an exercise device in the next generation of spacecraft is limited and therefore compact resistance exercise device prototypes are being developed. The Advanced Resistive Exercise Device (ARED) currently on the ISS is being used as a benchmark for the functional performance of these new devices. Biomechanical data collection and computational modeling aid the device design process by quantifying the joint torques and musculoskeletal forces that occur during exercises performed on the prototype devices. Computational models currently use OpenSim software, an open source code for musculoskeletal modeling, with biomechanical input data from subjects for estimation of muscle and joint loads. Subjects are instrumented with reflective markers for motion capture data collection while exercising on the Hybrid Ultimate Lifting Kit (HULK) prototype device. Ground reaction force data is collected with force plates under the feet and device loading is recorded through load cells internal to the HULK. This data is input into the OpenSim biomechanical model, which has been scaled to match the anthropometrics of the test subject, to calculate the loads on the body. Multiple exercises are performed and evaluated during a test session such as a full squat, single leg squat, heel raise and dead lift. Variables for these exercises include applied device load, narrow or wide foot stance, slow or fast cadence and the harness or long bar interface between the test subject and the device. Data from free weights are compared to the resistively loaded exercise device. The focus of this presentation is to summarize the results from the single-leg squat and heel raise exercises performed during three sessions occurring in 2015. Differences in loading configuration, cadence and stance produce differences in kinematics, joint toques and force and muscle forces.

computational modeling↗

PBG-slab Embedded Traveling Wave Structure for Planar Beam Accelerator Application

The oversized traveling wave (TE10-mode) channel integrated with the photonic-band-gap (PBG) slab arrays have been investigated for planar beam accelerator application. Simulation analysis showed that the slab arrays allow only the PBG-modes ( 5-6 GHz) to propagate with ~ 2 dB of insertion loss, corresponding to ~ 1.14 dB/cm attenuation, which thereby effectively suppresses trapped non-PBG modes down to ~ -14.3 dB/cm. It will enable monochromatic propagation of fundamental acceleration modes al ong the heavily over-moded planar waveguide without anomalous excitation of unstable trapped HOMs. The saturated maximum field gradients of the accelerating structure have been analyzed with respect to operational frequency bands corresponding to structur al sizes. The field gradient of the guided PBG-mode has been investigated with finite-integral-method (FIM) simulations at W-band. This mode-filter could be utilized for HOM dampers in high aspect ratio (HAR) planar beam accelerators. An experimental test is currently under consideration.

43 PARTICLE ACCELERATORS↗

Ethynylated aromatics as high temperature matrix resins

Difunctional and trifunctional arylacetylenes were used as monomers to form thermoset matrix resin composites. Composites can be hot pressed at 180 C to react 80 percent of the acetylene groups. Crosslinking is completed by postcuring at 350 C. The postcured resins are thermally stable to nominally 460 C in air. As a result of their high crosslink density, the matrix exhibits brittle failure when unaxial composites are tested in tension. Failure of both uniaxial tensile and flexural specimens occurs in shear at the fiber matrix interface. Tensile fracture stresses for 0 deg composites fabricated with 60 v/o Celion 6K graphite fiber were 827 MPa. The strain to failure was 0.5 percent. Composites fabricated with 8 harness satin Celion cloth (Fiberite 1133) and tested in tension also failed in shear at tensile stresses of 413 MPa.

Hurwitz, Frances I.↗

Ethynylated aromatics as high temperature matrix resins

Difunctional and trifunctional arylacetylenes were used as monomers to form thermoset matrix resin composites. Composites can be hot-pressed at 180 C to react 80 percent of the acetylene groups. Crosslinking is completed by postcuring at 350 C. The postcured resins are thermally stable to nominally 460 C in air. As a result of their high crosslink density, the matrix exhibits brittle failure when uniaxial composites are tested in tension. Failure of both uniaixial tensile and flexural specimens occurs in shear at the fiber-matrix interface. Tensile fracture stresses for 0-deg composites fabricated with 60 v/o Celion 6K graphite fiber were 827 MPa. The strain to failure was 0.5 percent. Composites fabricated with 8 harness satin Celion cloth (Fiberite 1133) and tested in tension also failed in shear at tensile stresses of 413 MPa.

Hurwitz, F. I.↗

Cryo-vacuum testing of the JWST Integrated Science Instrument Module (SPIE)

In late 2015/early 2016, a major cryo-vacuum test was carried out for the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST). This test comprised the final cryo-certification and calibration test of the ISIM, after its ambient environmental test program (vibration, acoustics, EMI/EMC), and before its delivery for integration with the rest of the JWST observatory. Over the 108-day period of the round-the-clock test program, the full complement of ISIM flight instruments, structure, harness radiator, and electronics were put through a comprehensive program of thermal, optical, electrical, and operational tests. The test verified the health and excellent performance of the instruments and ISIM systems, proving the ISIM element's readiness for integration with the telescope. We report here on the context, goals, setup, execution, and key results for this critical JWST milestone.

James Webb Space Telescope (JWST)↗

Cryo-Vacuum Testing of the JWST Integrated Science Instrument Module

In late 2015 early 2016, a major cryo-vacuum test was carried out for the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope. This test comprised the final cryo-certification and calibration test of the ISIM before its delivery for integration with the rest of the JWST observatory. Over the roughly 100-day period of the round-the-clock test program, the full complement of ISIM flight instruments, structure, harness radiator, and electronics were put through a comprehensive program of thermal, optical, electrical, and operational tests. We briefly summarize the goals, setup, execution, and key results for this critical JWST milestone.

cryo-vacuum test↗

Measuring Rind Thickness on Polyurethane Foam

Nondestructive test determines rind thickness of polyurethane foam. Surface harness of foam measured by Shore durometer method: hardness on Shore D scale correlates well with rind thickness. Shore D hardness of 20, for example, indicates rind thickness of 0.04 inch (1 millimeter). New hardness test makes it easy to determine rind thickness of sample nondestructively and to adjust fabrication variables accordingly.

Johnson, C.↗

Minor actinide separation: simplification of the DIAMEX-SANEX strategy by means of novel SANEX processes

The separation of An(III) from PUREX raffinate has previously been demonstrated by applying a DIAMEX process (i.e., co-extraction of An(III) and Ln(III) from HAR) followed by a SANEX process (i.e., selective extraction of An(III) from the DIAMEX product containing An(III) + Ln(III)). In line with process intensification issues, more compact processes have been developed: Recently, a 1c-SANEX process test was successfully performed, directly extracting An(III) from PUREX HAR. More recently, a new i-SANEX process was successfully tested. This process is based on the co-extraction of An(III) + Ln(III) into a TODGA solvent, followed by a selective back-extraction of An(III) by a water soluble complexing agent, in this case SO{sub 3}-Ph-BTP. In both cases, good recoveries were achieved, and very pure product solutions were obtained. However, both 1c-SANEX and i-SANEX used non-CHON chemicals. Nevertheless, these processes are a simplification to the DIAMEX + SANEX process as only one solvent is used. Finally, the new i-SANEX process is the most compact process. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Coarse Pointing Assembly for Optical Communication

In the framework of a contract with the European Space Agency, RUAG Space are developing a Coarse Pointing Assembly for an Optical Communication Terminal with the goal to enable high-bandwidth data exchange between GEO and/or LEO satellites as well as to earth-bound ground stations. This paper describes some development and testing aspects of such a high precision opto-mechanical device, with emphasis on the influence of requirements on the final design, the usage of a Bearing Active Preload System, some of the lessons learned on the BAPS implementation, the selection of a flex print design as rotary harness and some aspects of functional and environmental testing.

Szekely, G.↗

Flammability testing conducted in support of Apollo 13

In support of the Apollo 13 investigation of the oxygen tank failure, flame propagation rates were determined for Teflon insulation in cryogenic and ambient temperature oxygen for upward, downward, and zero g burns. The propagation rates depended heavily on configuration and varied from 4.8 to 10.9 cm/sec for upward one g burns to 0.48 cm/sec for zero g burns. In addition to the flame propagation rates, tests were conducted to determine if Teflon burning in cryogenic oxygen could ignite metals (promoted ignition) with which it came in contact. Tests conducted on various metal alloys used in the oxygen tank indicated that most of the alloys could be ignited by burning Teflon in certain configurations. After the propagation rates and promoted metal ignitions had been evaluated, a test was conducted on a quantity gauge and wire harness used in the oxygen tank to determine if flame propagation to the tank wall was possible. Propagation of the wire bundle after ignition resulted in a catastrophic failure of the test vessel in the area of the quantity gauge.

Leger, L. J.↗