Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing methodology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Extension of service life of rigid transfer lines /SMDC/

The results of a life evaluation program on rigid explosive transfer lines, which are used to initiate aircraft emergency crew escape functions, are presented in order to provide quantitative information on rigid explosive transfer lines which can contribute to responsible, conservative, service life determinations. The program involved the development of a test methodology, testing of the three types of transfer lines in use in the U.S., testing of these lines following a repeat of the thermal test conducted in the original qualification, and conducting a degradation investigation. Results from the testing of more than 800 components showed that rigid explosive transfer lines were not affected by age, service, or a repeat of the thermal qualification tests on full-service lines. The explosive degradation limits were approximated and the mechanisms examined. It is concluded that the service lives of rigid explosive transfer lines should be considered for extension in order to provide cost savings and increased system reliability.

Bement, L. J.↗

Advanced Retrieval Demonstrations of the Hanford Waste End Effector - 19383

This paper describes advanced retrieval demonstrations of the Hanford Waste End Effector (HWEE) at the Washington River Protection Solutions (WRPS) Cold Test Facility conducted by Pacific Northwest National Laboratory (PNNL) in co-operation with the U.S. Department of Energy - Office of River Protection and WRPS. The HWEE is a water-based scarifier originally developed by PNNL for the U.S. Department of Energy tank retrieval systems in the 1990's as the confined sluicing end effector and later used with additional development in the waste retrieval of tanks at Oak Ridge National Laboratory. The HWEE is being assessed for potential use in Hanford tank retrievals because it is expected to use less water during waste retrieval than other water-based methods (e.g., sluicing) previously used in Hanford tanks. This is primarily because the HWEE uses three rotating high-pressure jets for dislodging the waste and a high-velocity conveyance system to retrieve the water and the waste locally at the point of waste dislodging. The retrieval demonstrations build on previous development testing (Phase I) completed in 2017 by addressing key tank waste challenges, including retrieval of a mixed layered simulant and retrieval of uneven simulant profiles like that found near tank walls. The tests involved retrieval of water and kaolin (sludge) simulant to determine pumping rate, dilution factors, and a demonstration of vertical pumping capability. Upgrades to the HWEE for Phase II testing included a more robust inlet screen, internal flush jet modification for lower water usage, and removal of the external flush mole that was not used during Phase I retrieval testing. In addition, a rotational positioning capability was added to the three-dimensional gantry to gain additional movement capability and flexibility needed to implement more complex retrieval mining techniques. Two simulant configuration options using existing simulant materials were defined to represent key Hanford tank waste properties: 1) layered waste (e.g., strong crust over weaker sediment) and 2) topography that is representative of tank waste (uneven surface). Historical information from Hanford waste, including tank history, sampling reports, and images, was investigated to define the simulant characteristics and physical configuration. Using the layered simulant configuration, retrieval tests focused on demonstrating the same operational parameters irrespective of simulant strength. The focus of the topographical retrieval test was to demonstrate the ability to clean next to the tank wall using a tilted HWEE and to demonstrate water confinement using a specific mining strategy. This paper will describe the Phase II test equipment, instrumentation, simulant preparation procedures, and testing methodology. Testing results that will be presented include HWEE water usage versus operating pressure, simulant characterization data, dilution ratios, and retrieval rates. Reaction forces and other factors that would affect the remote operation of the HWEE will also be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surveillance systems test and evaluation facilities

In January of 1983, a team was formed to explore test methodologies and test facility concepts required to meet the needs of space-based surveillance systems. The output of this study was a road map of test methodologies and test facilities that will aid the development of this country's critical space-based sensor assets. A condensation of those results is given.

Matty, Jere J.↗

Using Hardware-In-The-Loop Methodology to Develop Test Systems

Hardware in the Loop (HIL) testing methodologies have become widespread in industry. Typically, they focus on developing control algorithms for systems such as autonomous vehicles or aircraft. An oft overlooked aspect of product development is the design and fabrication of a test system for validating that the product meets requirements. Abstractly, a test system differs little from a control system—testers provide signals to the unit, monitor feedback, and base decisions on the results. While the time scales may differ, the functionalities are conceptually similar. Viewed in this light, it becomes natural to extend HIL approaches to tester development. By replacing a physical unit with a proxy model deployed to a real-time or pseudo real-time target, test systems can be developed in parallel with the design and fabrication of a first production unit. This saves considerable time in the life cycle from conceptual design to realized product. This manuscript demonstrates the process flow using a capacitive discharge unit as an exemplar.

42 ENGINEERING↗

Life Prediction/Reliability Data of Glass-Ceramic Material Determined for Radome Applications

Brittle materials, ceramics, are candidate materials for a variety of structural applications for a wide range of temperatures. However, the process of slow crack growth, occurring in any loading configuration, limits the service life of structural components. Therefore, it is important to accurately determine the slow crack growth parameters required for component life prediction using an appropriate test methodology. This test methodology also should be useful in determining the influence of component processing and composition variables on the slow crack growth behavior of newly developed or existing materials, thereby allowing the component processing and composition to be tailored and optimized to specific needs. Through the American Society for Testing and Materials (ASTM), the authors recently developed two test methods to determine the life prediction parameters of ceramics. The two test standards, ASTM 1368 for room temperature and ASTM C 1465 for elevated temperatures, were published in the 2001 Annual Book of ASTM Standards, Vol. 15.01. Briefly, the test method employs constant stress-rate (or dynamic fatigue) testing to determine flexural strengths as a function of the applied stress rate. The merit of this test method lies in its simplicity: strengths are measured in a routine manner in flexure at four or more applied stress rates with an appropriate number of test specimens at each applied stress rate. The slow crack growth parameters necessary for life prediction are then determined from a simple relationship between the strength and the applied stress rate. Extensive life prediction testing was conducted at the NASA Glenn Research Center using the developed ASTM C 1368 test method to determine the life prediction parameters of a glass-ceramic material that the Navy will use for radome applications.

Choi, Sung R.↗

Composite Overwrapped Pressure Vessel (COPV) Damage Tolerance Life Analysis Methodology and Test Best Practices

The NASA Engineering and Safety Center (NESC) Deputy Director requested an independent assessment to develop data to understand the limitations of linear elastic fracture mechanics (LEFM) computational methods used to predict fatigue crack growth rate (da/dN) behavior of small detectable cracks in thin metal liners for composite overwrapped pressure vessels (COPVs). The NESC assessment team was also requested to demonstrate a test-based methodology for validating damage tolerance requirements for COPVs with elastically responding metal liners where LEFM methods are not appropriate. This report contains the outcome of the NESC assessment.

Composite Overwrapped Pressure Vessels; Linear Ela↗

Composite Overwrapped Pressure Vessel (COPV) Damage Tolerance Life Analysis Methodology and Test Best Practices: Appendices

The NASA Engineering and Safety Center (NESC) Deputy Director requested an independent assessment to develop data to understand the limitations of linear elastic fracture mechanics (LEFM) computational methods used to predict fatigue crack growth rate (da/dN) behavior of small detectable cracks in thin metal liners for composite overwrapped pressure vessels (COPVs). The NESC assessment team was also requested to demonstrate a test-based methodology for validating damage tolerance requirements for COPVs with elastically responding metal liners where LEFM methods are not appropriate. This document contains the appendices to the main report.

Composite Overwrapped Pressure Vessels; Linear Ela↗

Influence of Test Procedures on the Thermomechanical Properties of a 55NiTi Shape Memory Alloy

Over the past few decades, binary NiTi shape memory alloys have received attention due to their unique mechanical characteristics, leading to their potential use in low-temperature, solid-state actuator applications. However, prior to using these materials for such applications, the physical response of these systems to mechanical and thermal stimuli must be thoroughly understood and modeled to aid designers in developing SMA-enabled systems. Even though shape memory alloys have been around for almost five decades, very little effort has been made to standardize testing procedures. Although some standards for measuring the transformation temperatures of SMA s are available, no real standards exist for determining the various mechanical and thermomechanical properties that govern the usefulness of these unique materials. Consequently, this study involved testing a 55NiTi alloy using a variety of different test methodologies. All samples tested were taken from the same heat and batch to remove the influence of sample pedigree on the observed results. When the material was tested under constant-stress, thermal-cycle conditions, variations in the characteristic material responses were observed, depending on test methodology. The transformation strain and irreversible strain were impacted more than the transformation temperatures, which only showed an affect with regard to applied external stress. In some cases, test methodology altered the transformation strain by 0.005-0.01mm/mm, which translates into a difference in work output capability of approximately 2 J/cu cm (290 in!lbf/cu in). These results indicate the need for the development of testing standards so that meaningful data can be generated and successfully incorporated into viable models and hardware. The use of consistent testing procedures is also important when comparing results from one research organization to another. To this end, differences in the observed responses will be presented, contrasted and rationalized, in hopes of eventually developing standardized testing procedures for shape memory alloys.

Padula, Santo A., II↗

SU-E-I-65: The Joint Commission's Requirements for Annual Diagnostic Physics Testing of Nuclear Medicine Equipment, and a Clinically Relevant Methodology for Testing Low-Contrast Resolution

Purpose: To introduce the Joint Commission's requirements for annual diagnostic physics testing of all nuclear medicine equipment, effective 7/1/2014, and to highlight an acceptable methodology for testing lowcontrast resolution of the nuclear medicine imaging system. Methods: The Joint Commission's required diagnostic physics evaluations are to be conducted for all of the image types produced clinically by each scanner. Other accrediting bodies, such as the ACR and the IAC, have similar imaging metrics, but do not emphasize testing low-contrast resolution as it relates clinically. The proposed method for testing low contrast resolution introduces quantitative metrics that are clinically relevant. The acquisition protocol and calculation of contrast levels will utilize a modified version of the protocol defined in AAPM Report #52. Results: Using the Rose criterion for lesion detection with a SNRpixel = 4.335 and a CNRlesion = 4, the minimum contrast levels for 25.4 mm and 31.8 mm cold spheres were calculated to be 0.317 and 0.283, respectively. These contrast levels are the minimum threshold that must be attained to guard against false positive lesion detection. Conclusion: Low contrast resolution, or detectability, can be properly tested in a manner that is clinically relevant by measuring the contrast level of cold spheres within a Jaszczak phantom using pixel values within ROI's placed in the background and cold sphere regions. The measured contrast levels are then compared to a minimum threshold calculated using the Rose criterion and a CNRlesion = 4. The measured contrast levels must either meet or exceed this minimum threshold to prove acceptable lesion detectability. This research and development activity was performed by the authors while employed at West Physics Consulting, LLC. It is presented with the consent of West Physics, which has authorized the dissemination of the information and/or techniques described in the work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A methodology for testing fault-tolerant software

A methodology for testing fault tolerant software is presented. There are problems associated with testing fault tolerant software because many errors are masked or corrected by voters, limiter, or automatic channel synchronization. This methodology illustrates how the same strategies used for testing fault tolerant hardware can be applied to testing fault tolerant software. For example, one strategy used in testing fault tolerant hardware is to disable the redundancy during testing. A similar testing strategy is proposed for software, namely, to move the major emphasis on testing earlier in the development cycle (before the redundancy is in place) thus reducing the possibility that undetected errors will be masked when limiters and voters are added.

Andrews, D. M.↗

Preloading To Accelerate Slow-Crack-Growth Testing

An accelerated-testing methodology has been developed for measuring the slow-crack-growth (SCG) behavior of brittle materials. Like the prior methodology, the accelerated-testing methodology involves dynamic fatigue ( constant stress-rate) testing, in which a load or a displacement is applied to a specimen at a constant rate. SCG parameters or life prediction parameters needed for designing components made of the same material as that of the specimen are calculated from the relationship between (1) the strength of the material as measured in the test and (2) the applied stress rate used in the test. Despite its simplicity and convenience, dynamic fatigue testing as practiced heretofore has one major drawback: it is extremely time-consuming, especially at low stress rates. The present accelerated methodology reduces the time needed to test a specimen at a given rate of applied load, stress, or displacement. Instead of starting the test from zero applied load or displacement as in the prior methodology, one preloads the specimen and increases the applied load at the specified rate (see Figure 1). One might expect the preload to alter the results of the test and indeed it does, but fortunately, it is possible to account for the effect of the preload in interpreting the results. The accounting is done by calculating the normalized strength (defined as the strength in the presence of preload the strength in the absence of preload) as a function of (1) the preloading factor (defined as the preload stress the strength in the absence of preload) and (2) a SCG parameter, denoted n, that is used in a power-law crack-speed formulation. Figure 2 presents numerical results from this theoretical calculation.

Gyekenyesi, John P.↗

Prediction of Composite Pressure Vessel Failure Location using Fiber Bragg Grating Sensors

Ten composite pressure vessels were instrumented with fiber Bragg grating sensors in order to assess the strain levels of the vessel under various loading conditions. This paper and presentation will discuss the testing methodology, the test results, compare the testing results to the analytical model, and present a possible methodology for predicting the failure location and strain level of composite pressure vessels.

Kreger, Steven T.↗

The Effect of the Presence of Ozone on the Lower Flammability Limit (LFL) of Hydrogen in Vessels Containing Savannah River Site High Level Waste - 12387

The Enhanced Chemical Cleaning (ECC) process uses ozone to effect the oxidation of metal oxalates produced during the dissolution of sludge in the Savannah River Site (SRS) waste tanks. The ozone reacts with the metal oxalates to form metal oxide and hydroxide precipitants, and the CO{sub 2}, O{sub 2}, H{sub 2}O and any unreacted O{sub 3} gases are discharged into the vapor space. In addition to the non-radioactive metals in the waste, however, the SRS radioactive waste also contains a variety of radionuclides, hence, hydrogen gas is also present in the vapor space of the ECC system. Because hydrogen is flammable, the impact of this resultant gas stream on the Lower Flammability Limit (LFL) of hydrogen must be understood for all possible operating scenarios of both normal and off-normal situations, with particular emphasis at the elevated temperatures and pressures of the typical ECC operating conditions. Oxygen is a known accelerant in combustion reactions, but while there are data associated with the behavior of hydrogen/oxygen environments, recent, relevant studies addressing the effect of ozone on the flammability limit of hydrogen proved scarce. Further, discussions with industry experts verified the absence of data in this area and indicated that laboratory testing, specific to defined operating parameters, was needed to comprehensively address the issue. Testing was thus designed and commissioned to provide the data necessary to support safety related considerations for the ECC process. A test matrix was developed to envelope the bounding conditions considered credible during ECC processing. Each test consists of combining a gas stream of high purity hydrogen with a gas stream comprised of a specified mixture of ozone and oxygen in a temperature and pressure regulated chamber such that the relative compositions of the two streams are controlled. The gases are then stirred to obtain a homogeneous mixture and ignition attempted by applying 10J of energy to a fuse wire. A gas combination is considered flammable when a pressure rise of 7% of the initial absolute pressure is observed. The specified testing methodology is consistent with guidelines established in ASTM E-918-83 (2005) 'Standard Practices for Determining Limits of Flammability of Chemicals at Elevated Temperature and Pressure'. The LFL of hydrogen in air was determined and is in good agreement with the literature data. Ozone-oxygen mixtures were found to be flammable at concentrations above 8.3 vol.% based on the ASTM E918 7% pressure rise criteria for flame propagation. This result is lower than previously reported values which can be explained through the variations in the test setup and procedure. It is believed that the lower values obtained in this work are a result of improvements of the test methodology. Tests performed with hydrogen in various concentrations of ozone in oxygen have shown that the LFL of hydrogen decreases as the concentration of ozone in the mixture increases. This testing was designed to provide data under the conditions considered most optimal to produce deflagration. The geometry and materials of construction of the testing vessel; the location of the fuse wire; the magnitude of the supplied energy; the careful minimization of diluents and other contaminants; and meticulous procedural detail to maintain integrity of the ozone to the maximum extent practical, result in data that reflect not the expected process conditions, but those that enhance the possibility of flame propagation. For this reason, there is believed to be considerable conservatism in the indicated results. Per the vendor, the maximum possible ozone concentration producible by the planned ECC Ozone generator is 8 volume percent (the typical maximum operating setpoint concentration is 6.8 vol%), less than the 8.3 minimum volume % concentration shown to be flammable in a 99.999% pure O{sub 2} environment at the optimally conservative conditions established in this testing. Further, the feed to the ECC ozone generator is only 87% oxygen, the remainder, water vapor and nitrogen, both powerful diluents. It is, thus, believed not credible that deflagration can occur at this maximum feed concentration condition. In addition, once the ozone stream contacts the waste stream, the many simultaneous oxidizing reactions will rapidly decompose available ozone to well below flammable levels. Further, because the radiolytically generated hydrogen quantity is negligible compared to the supplied ozone/oxygen stream (0.0004 moles per minute H{sub 2} vs 76 moles per minute ozone/oxygen), even the total H{sub 2}/O{sub 3} mixture, without crediting decomposition reactions, does not approach flammable concentrations. Finally, even at the 'end' of the ECC batch cycle, when most of the metal oxalates have been decomposed, testing has indicated that the ozone concentration in the vapor space of the ECC process vessel reaches a concentration of no more than 3 vol%, remaining well below concentrations of concern. The major issue for the ECC operation established by this testing is the impact of the data when applied to off normal conditions. While it is possible to discontinue ozone addition to the reaction vessel at any time, the radiolytic hydrogen generation rate continues, varying slightly as ambient pressures and temperatures change. Relative to the data generated and analyzed in this testing, the ECC hazards analysis team will re-evaluate off normal conditions (e.g. those during which process exhaust ventilation is lost) such that issues involving mixtures of hydrogen and ozone in the vapor space can be appropriately controlled. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing performance of ultra-sensitive accelerometers

An overview is given of methodology and test results pertaining to the characterization of ultra sensitive accelerometers. Two issues are of primary concern. The terminology ultra sensitive accelerometer is used to imply instruments whose noise floors and resolution are at the state of the art. Hence, the typical approach of verifying an instrument's performance by measuring it with a yet higher quality instrument (or standard) is not practical. Secondly, it is difficult to find or create an environment with sufficiently low background acceleration. The typical laboratory acceleration levels will be at several orders of magnitude above the noise floor of the most sensitive accelerometers. Furthermore, this background must be treated as unknown since the best instrument available is the one to be tested. A test methodology was developed in which two or more like instruments are subjected to the same but unknown background acceleration. Appropriately selected spectral analysis techniques were used to separate the sensors' output spectra into coherent components and incoherent components. The coherent part corresponds to the background acceleration being measured by the sensors being tested. The incoherent part is attributed to sensor noise and data acquisition and processing noise. The method works well for estimating noise floors that are 40 to 50 dB below the motion applied to the test accelerometers. The accelerometers being tested are intended for use as feedback sensors in a system to actively stabilize an inertial guidance component test platform.

Sebesta, Henry↗

Using tools for verification, documentation and testing

Methodologies are discussed on four of the major approaches to program upgrading -- namely dynamic testing, symbolic execution, formal verification and static analysis. The different patterns of strengths, weaknesses and applications of these approaches are shown. It is demonstrated that these patterns are in many ways complementary, offering the hope that they can be coordinated and unified into a single comprehensive program testing and verification system capable of performing a diverse and useful variety of error detection, verification and documentation functions.

Osterweil, L. J.↗

NGST Optical Testing

An Integrated Product Team (IPT) was formed to develop a detailed optical test methodology for testing of the Next Generation Space Telescope (NGST) mirrors and the optical system on the ground. Optical testing is a significant cost driver therefore the testing has to be planned in detailed fashion early. This paper will discuss the preliminary metrology test plan at the mirror component and telescope system level. Instrumentation, facilities and schedule will also be addressed.

Keski-Kuha, Ritva↗

NGST OTA Optical Metrology Instrumentation and Conceptual Approaches

An Integrated Product Team (IPT) was formed to develop a detailed concept for optical test methodology for testing of the NGST individual primary, secondary and tertiary mirrors and the full telescope system on the ground. Optical testing is a significant cost driver therefore the testing has to understood in detailed fashion early. A brief summary of the preliminary metrology test plan at the mirror component and telescope system level is presented.

Keski-Kuha, R.↗