Turbulent Rotating Rayleigh–Bénard Convection

Rotation with thermally induced buoyancy governs many astrophysical and geophysical processes in the atmosphere, ocean, sun, and Earth's liquid-metal outer core. Rotating Rayleigh–Bénard convection (RRBC) is an experimental system that has features of rotation and buoyancy, where a container of height H and temperature difference Δ between its bottom and top is rotated about its vertical axis with angular velocity Ω. The strength of buoyancy is reflected in the Rayleigh number (~ H 3 Δ) and that of the Coriolis force in the Ekman and Rossby numbers (~Ω -1 ). Rotation suppresses the convective onset, introduces instabilities, changes the velocity boundary layers, modifies the shape of thermal structures from plumes to vortical columns, affects the large-scale circulation, and can decrease or enhance global heat transport depending on buoyant and Coriolis forcing. RRBC is an extremely rich system, with features directly comparable to geophysical and astrophysical phenomena. Here we review RRBC studies, suggest a unifying heat transport scaling approach for the transition between rotation-dominated and buoyancy-dominated regimes in RRBC, and discuss non-Oberbeck–Boussinesq and centrifugal effects.

42 ENGINEERING↗

Quarterly Research Performance Progress Report (Q8)

As part of Task 1, we have started by testing our modeling capabilities by reproducing isothermal DFIT simulations presented in the literature. Once satisfied with the results we have started by targeting the modeling of the DFITs at conducted at well 58-32. We have a identified a specific test (cycle 4 in zone 2) as the most interesting to be model with GEOS hydraulic fracturing module. Thus, we have first produced results with an isothermal model and adjusted model parameters to get a satisfying match with field pressure data. The, we have added thermal effects and compared the modeling results with and without thermal effects to estimate how thermal effects may influence test interpretation. Models seem to suggest that, for small volumes of fluid, thermal effects are moderate. In Task 2, we have adapted GEOS phase-field formulation to be able to simulate near-wellbore hydraulic fracture nucleation and propagation. We have devised a novel formulation that, compared to other existing ones, incorporates rock strengths. We have submitted a journal publication about our work. We are currently employing this phase-field formulation to model the experiments taking place at U Pitt and help us understand the effect of various parameters. In Task 3, we have built a model of the region surround well 16A and have started modeling stage 3 stimulation because of its simpler planar geometry. After calibrating simulation parameters using known analytical solutions, we have simulated the stage 3 stimulation using our isothermal hydraulic fracturing module, varying the permeability field, the stress conditions including different physics to get a better understanding of the numerical challenges and of the effects of varying these parameters on the simulation results. In Task 4 laboratory experimentation, a set of specialized drilling and injection tools has been customized and constructed to accommodate an inclined well with an orientation of up to 30 degrees relative to material anisotropy or principal stress axes. These inclined samples have also undergone thermal stress and hydraulic fracturing at a temperature of 190 degrees Celsius. Furthermore, both vertical and deviated sampling testing setups enable an extended analysis of post-peak pressure behaviors, facilitating post-test pressure analyses such as the G-function, step rate, and fracture reopening measurements. Thus, the key components of in-situ stress estimation can be extracted and validated through our experiment, providing a solid foundation for validating existing in-situ stress estimation theories or proposing new ones. Simultaneously, we are integrating computer vision techniques with traditional experimental fracture observation methods such as multi-overcore/slicing and water-penetration fracture observation. This combination will prove beneficial in populating the hydraulic fracture patterns database, generated under challenging EGS conditions. This approach aims to deepen our understanding of the complexities in EGS reservoirs and pave the way for future data-driven investigations. Additionally, PITT has also equipped the ELE International compression machine, which is now prepared for conducting indirect tensile and fracture toughness tests. These tests will aid in characterizing how rock fabrics influence the resulting fracture patterns. Additionally, we have completed the required personnel training and gained access to Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) for conducting more detailed characterization and analysis of rock fabrics, as well as the examination of thermal and hydraulically induced fracture patterns. Thus, the PITT team has effectively demonstrated the capabilities of our experimental apparatuses in exploring the thermal effects, well deviation angles, material anisotropy, and operational choices (such as circulation rate, injection fluid viscosity, and injection rate) and their impact on pressure responses and fracture trajectories under the Utah FORGE conditions.

15 GEOTHERMAL ENERGY↗

Impacts of the Thermal Gradient on Inland Advecting Sea Breezes in the Southeastern United States

Sea breezes are frequently observed in the South Carolina/Georgia region of the Southeastern United States (SEUS) and can reach upwards of 150km inland. This region is unique among the places frequently affected by sea breeze due to it being a continental location with relatively flat topography. The thermal gradient between land and water environments is a factor in introducing the sea breeze, but its role in the inland extent of sea breeze propagation isn’t as well known. We investigate the role of the thermal gradient in previously catalogued sea breeze events observed at the Savannah River Site (SRS) by taking differences of temperature measurements at inland and coastal weather stations for the days that the events occurred. We saw that the temperature differences for those days were much higher than in the non-sea breeze days during the mornings and afternoon. Numerical models were also used to conduct a sensitivity study on a sea breeze case, using simple modifications of the temperature gradient. We found that while the modifications did not stop the generation of a sea breeze circulation, the extent of the inland propagation was dependent on the magnitude of the thermal gradient.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Thermal Stratification in Versatile Test Reactor Transients

The Versatile Test Reactor (VTR) is a fast-spectrum test reactor currently being developed in the United States under the direction of the US Department of Energy. The conceptual design of the 300 MWth pool-type sodium-cooled fast reactor (SFR) has been led by the US National Laboratories in collaboration with General Electric-Hitachi and Bechtel National Inc. Safety performance analysis for the VTR conceptual design is being performed with the systems thermal-hydraulics (SYSTH) module of the SAS4A/SASSYS-1 liquid-metal reactor safety analysis code system. Since the current model of the VTR employs a simple perfect mixing model for large plena like the hot pool, it is not able to predict temperature variations that may develop during the transient. Prior work simulating the response of SFRs to postulated events like the Protected Station Blackout (PSBO) has shown that the phenomenon of thermal stratification, where stable thermal layers accumulate in the hot pool, may delay the transition to natural circulation and thus impact the predicted transient progression. Thus, an effort has begun to model this transient by integrating a Computational Fluid Dynamics (CFD) model of the hot pool into the SAS4A/SASSYS-1 model of the Primary Heat Transport System during the simulation of the PSBO event. A three-dimensional Volume-Of-Fluid CFD model of the VTR hot pool has been developed for the co-simulation of SAS4A/SASSYS-1 with CFD. In this work, the standalone SAS4A/SASSYS-1 calculation and the standalone CFD calculation based on the SAS4A/SASSYS-1 calculation result were produced on the Idaho National Laboratory High Performance Computing cluster, SAWTOOTH. At this time, only the standalone CFD and SAS4A/SASYS-1 simulation results are provided.

99 GENERAL AND MISCELLANEOUS↗

Thermal Analysis and Simulations of the Abort Kicker Magnets Systems for the Electron-Ion Collider

The Abort Kicker Magnets system used in the current Relativistic Heavy Ion Collider (RHIC) to steer the circulating beam into the dump will be subjected to higher heat loads in the Electron-Ion Collider (EIC). After analyzing the existing abort kicker magnets and running thermal simulations in ANSYS it was concluded that they may not be suitable for use as-is in the future EIC due to heat and impedance concerns in the magnets. Possible solutions include adding a round titanium-coated ceramic beam tube to help solve the heat and impedance concerns, but this will reduce the limiting aperture of the kicker magnet. Another possible solution to meet all the performance requirements for EIC would be to add titanium-coated ceramic plates with water-cooling and tapered transitions that significantly improve the impedance and lower the heat in the magnets with less reduction to the aperture.

43 PARTICLE ACCELERATORS↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

A Dual-Active-Bridge Converter Employing a Variable Inductor Without an Auxiliary Circuit

This paper proposes a dual active bridge (DAB) converter employing a variable inductor (VI) without an auxiliary circuit. Unlike conventional VI-based designs that require an external DC bias circuit, the proposed DAB utilizes the input DC current itself as the bias source, enabling automatic inductance variation with load conditions. The inductance naturally increases at low power and decreases at high power, effectively extending the zero voltage switching (ZVS) range and reducing circulating current, respectively. The VI was experimentally implemented and characterized to obtain its inductance-current profile, which was then integrated into a PLECS model of the DAB converter for circuit and thermal simulations. Simulation results confirm that the proposed auxiliary-free VI-DAB converter achieves a wider ZVS range and lower circulating current compared with a conventional fixed-inductor DAB converter. By realizing a variable inductor without any auxiliary bias circuitry, the proposed approach maintains soft switching and reduces reactive current losses across a wide load range, leading to improved efficiency and simplified implementation.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes two highly adsorptive structures positioned to receive thermal energy from a thermal energy source, each highly adsorptive structure includes a substrate and a metal-organic framework (MOF) coupled to the respective substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions. The adsorptive cooling system includes a cooling unit and a circulation system adapted for circulating the refrigerant from one of the highly adsorptive structures to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to the same or other highly adsorptive structure. Each substrate may include a plurality of microchannels, providing ingress and egress paths for a refrigerant, defined by grooves in a surface of the substrate nearest the MOF and/or surfaces of a plurality of microcapillaries of the substrate. The microchannels provide ingress and egress paths for a refrigerant.

Baumann, Theodore F.↗

Adsorption cooling system using metal organic frameworks

An adsorptive cooling system includes: a first highly adsorptive structure positioned to receive thermal energy from a thermal energy source, including: a first substrate; and a first metal-organic framework (MOF) coupled to the first substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions; a second highly adsorptive structure positioned to receive thermal energy from the thermal energy source including: a second substrate; and a second MOF coupled to the second substrate and adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions; a cooling unit; and a circulation system adapted for circulating refrigerant from the first highly adsorptive structure and the second highly adsorptive structure to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant to at least one of the first highly adsorptive structure and the second highly adsorptive structure.

Baumann, Theodore F.↗

Adsorption cooling system using carbon aerogel

An adsorptive cooling system includes: a first highly adsorptive structure positioned to receive thermal energy from a thermal energy source, the first highly adsorptive structure including: a first substrate; and a first carbon aerogel adhered to the first substrate, a second highly adsorptive structure positioned to receive thermal energy from the thermal energy source, the second highly adsorptive structure including: a second substrate; and a second carbon aerogel adhered to the second substrate, a cooling unit; and a circulation system adapted for circulating the refrigerant from at least one of the first highly adsorptive structure and the second highly adsorptive structure to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to at least one of the first highly adsorptive structure and the second highly adsorptive structure.

Baumann, Theodore F.↗

Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power

Molten salts are considered as candidate heat transfer fluids and thermal energy storage media for next generation concentrating solar power (CSP). A molten salt circulates inside the piping and heat exchanger and also functions as a lubricant for the sleeve bearings of the CSP pump. Furthermore, wear- and corrosion-resistant high-temperature bearing materials are critical for the pump efficiency and durability. This study evaluated the tribological performance of candidate bearing materials in lubrication of a molten chloride salt mixture (20% NaCl + 40% MgCl 2 + 40% KCl) at 750 °C in an inert argon gas (a simulative CSP pump environment). Six ceramic-alloy pairs were tested, zirconia and silicon nitride against Haynes 244, Hastelloy C276, and Tribaloy T900 alloy, and ranked by the friction coefficient and wear loss. Characterization of worn surfaces suggested the wear mechanism as a combination of abrasion, adhesion, and tribocorrosion. Results from this study provide fundamental insight for the development and selection of bearing materials for molten salt powered CSP pumps.

14 SOLAR ENERGY↗

Initial steady-state core simulation capability or thermal and pool-type molten salt reactors, coupling reactor physics, thermal-hydraulics, and evolving chemistry

This report presents the development and validation of an initial steady-state multiphysics capability for molten salt reactors (MSRs) under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in Fiscal Year 2025. The framework integrates neutronics, thermal-hydraulics, species transport, and thermochemistry to capture the coupled dynamics of liquid-fueled systems. Implementation and testing were performed on two representative designs: the Molten Salt Reactor Experiment (MSRE), a thermal-spectrum, channeled-flow reactor, and the Lotus Molten Salt Reactor (L-MSR), a fast-spectrum, pool-type reactor. The modeling suite employs Griffin for reactor physics and depletion, Pronghorn and SAM for thermal-hydraulics, Thermochimica for chemistry, and Saline for thermophysical properties, with benchmarking and validation carried out against historical MSRE data, experimental flow-loop measurements, and reference depletion calculations from Monte Carlo codes. The framework demonstrated the ability to reproduce key reactor behaviors including temperature feedback, reactivity losses, delayed neutron precursor transport, xenon poisoning, and redox potential evolution. The results confirm the feasibility and accuracy of the coupled models in predicting steady-state and selected transient MSR behaviors. This latter ones are used in this report as a proxy indicating that the steady-state models from which the transient starts are accurate. For MSRE, validation showed good agreement with pump start-up and natural circulation tests, while for the L-MSR, benchmarking confirmed hydraulic calibration and consistency of neutronics–thermal coupling. The tools also provided new insights into species transport, noble metal deposition, and salt solidification dynamics. On the Xenon transport front, the code is validated against the steady state Xenon poisoining measurement and showed good agreement with the experimental value. Identified areas for future work include advanced void transport modeling, three-dimensional simulations, improved alloy corrosion models, and tighter integration with high-fidelity Monte Carlo codes. These developments provide a foundation for high-fidelity MSR simulations that can support reactor design optimization, safety assessments, and long-term operational strategies.

42 - ENGINEERING↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

Investigation of Solid Particle Reactors for Nonoxidative Dehydrogenation of Ethane: Toward Solar Thermal Ethylene Production

Concentrating solar power plants can generate renewable heat at temperatures well above those of most industrial processes. Ceramic particles irradiated with concentrated sunlight can store high-quality sensible heat and transfer this to power generation systems. These concepts and materials hold great potential to also enable thermal processes in the chemical industry, but effective strategies for transferring heat from thermal energy storage media into chemical reactors are still under development. This present work evaluated the thermal and chemical compatibility of various solid particle media (including quartz, bauxite, and alumina particles) integrated directly into tube reactors and the subsequent effects on reactor performance for the nonoxidative dehydrogenation of ethane reaction. Empty tube reactors without loaded particles (representing conventional ethane cracking coils) showed significant heat transfer limitations as the tube diameter was scaled. The incorporation of media into the reactor significantly aided heat transfer to the gaseous ethane reactant and increased its conversion by as much as 10% at similar space velocities. Despite direct contact with hydrocarbon gases, alumina and quartz media showed negligible coke formation. Even during reaction in 100% ethane feed gas at 825 °C, the average selectivity of the coke product was only 0.57% when using the quartz media. These materials further demonstrated excellent thermal stability during subsequent reoxidation in air at 800 °C, which simulated the reheating of particles in a circulating particle solar receiver. Conversely, high rates of coke formation, with a product selectivity of 27.5%, were observed on sintered bauxite particles during the reaction, likely promoted by transition metal constituents. These particles fractured upon reoxidation due to exotherms generated from coke combustion. In conclusion, while the use of cofed steam could mitigate attrition of redox-active particles, the ability of inert metal oxide particles to efficiently transfer heat to concentrated ethane reactant gas while suppressing side reactions or degradation suggests that these media could effectively couple solar thermal plants to reactors for next-generation production of ethylene and other critical chemicals.

Hydrocarbons↗

Steam generator with inclined tube sheet

A steam generation system may include a plurality of heat transfer tubes configured to circulate a secondary coolant of the steam generation system. The steam generation system may be thermally coupled to a reactor vessel, and the reactor vessel may be configured to house a primary coolant. Heat generated from within the reactor vessel may be transferred from the primary coolant to the secondary coolant. The steam generation system may further include an inclined tube sheet fluidly coupled to the plurality of heat transfer tubes. The inclined tube sheet may be attached to a wall of the reactor vessel in a non-horizontal orientation.

42 ENGINEERING↗

[Presentation Slides] Code-to-Code Benchmark Study for Thermal Stress Modeling and Preliminary Analysis of the High-temperature Single Heat-Pipe Experiment

In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios. This presentation slides discuss finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL), using two commercial software packages, Abaqus and Star-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain preliminary insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the inner surface of the heat pipe hole surrounded by electric heaters where the largest temperature gradients appear. The temperature fields have good agreements between Abaqus and Star-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes. It is found that the local maximum thermal stresses may reach close to the ultimate tensile strength and yield strength of structural material depending on the heater power. Ultimately, the coupled thermal-structural analysis will help guide the current experimental plan and ensure the facility safety for future experimental study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Urban heat islands can influence the wind energy resource during heatwaves

Urban wind energy is critical for sustainable electricity generation in cities. However, little research has explored how the urban heat island (UHI) effect influences wind energy, particularly in heatwaves when energy demand surges. In this study, we examine wind energy distribution in the Boston–Providence metropolitan area during heatwaves, using Weather Research and Forecasting (WRF) model integrated with Building Energy Parameterization/Building Energy Model (BEP/BEM). Two scenarios, a realistic case and a hypothetical case without urban warmth, were compared to isolate UHI impacts. Results reveal that UHI induces a "wind energy loss zone" in this urban area, reducing wind power density (WPD) by 20–30 W/m 2 at 50–100 m, while suburban/rural areas exhibit a "wind energy gain zone," with WPD increases up to 40 W/m 2 at 150–200 m. These losses diminish with distance from urban centers and become negligible beyond main urban and suburban sprawl. Heatwave expands the urban "loss zone", while amplifying wind energy gains in suburban/rural areas, driven by stronger thermal gradients and weakened background winds that intensify air convergence in urban and urban-rural circulations, thereby exacerbating urban wind energy losses by 15–20 %. An analysis of 235 wind farms using turbine power curves reveals that built areas dependent on stand-alone or off-grid turbines face significant energy deficits during a heatwave. Wind energy drops by up to 25 %, while cooling-related building energy demand rises 30–40 % during a heatwave. These findings underscore the need for strategic urban wind energy planning to ensure reliable power during extreme heat.

Energy - Wind↗

System code evaluation of near-term accident tolerant claddings during pressurized water reactor station blackout accidents

Following the Fukushima Daiichi nuclear accident in 2011, researches on Accident-tolerant fuels (ATFs) are currently of high interest in not only the nuclear industry but also governmental and international organizations. In this work, a quantitative evaluation of the performance of monolithic FeCrAl cladding and Cr-coated Zircaloy cladding has been performed for Pressurized Water Reactor (PWR) Station Blackout (SBO) accidents. A generic PWR model has been built in system thermal-hydraulics code TRACE based on the Surry Nuclear Power Station with counter-current natural circulation modelling capability for hotleg and steam generator U-tube components during the accidents. The base model results are then compared to MELCOR and RELAP simulations to verify the system component implementation in TRACE. Two PWR SBO scenarios were investigated, including: short-term SBO and long-term SBO with early reactor coolant pump (RCP) seal failure. These scenarios are defined to be very similar to the accidents studied in the State-of-the-Art Reactor Consequence Analysis (SOARCA) project. TRACE code is modified to reflect the oxidation kinetics of FeCrAl and Cr-coating. Larson-Miller creep rupture model is also implemented in TARCE using its built-in control systems to simulate the creep rupture of hotlegs. Additionally, the comparison between the TRACE models with and without the counter-current flow modeling resulted in significant difference when comparing ATF cladding to Zircaloy for short term SBO, while it marginal impacted the performance during long term SBO with RCP seal failure. For short term SBO, both ATF cladding underwent hot leg creep rupture ~20 min after Zircaloy cladding. While Zircaloy and Cr-coated cladding had generated significant amount of hydrogen gas (>10 kg) before the creep rupture event, FeCrAl cladding had only generated <0.5 kg of hydrogen gas. For long term SBO with RCP seal failure, significant hydrogen generation and fuel melting was predicted before hot leg creep rupture for the ATF cladding while providing only 10–20 min additional coping time compared to Zircaloy.