Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A product data network to enable faster, easier, and better planning of building envelopes

The building envelopes contributes significantly to the energy-efficiency of the building. Building performance simulation has made it possible to compare façade technologies regarding energy demand, daylighting, thermal and visual comfort in detail. Planners, such as architects and engineers, need experience to find product data with the right quality and level of detail, and to process the data to fit the calculation and the application. In the available time, planners can compare only a limited number of products, which means that better solutions could go unnoticed. This paper presents a new concept for making product data easily accessible for building façade planning. The concept consists of a network of databases for the efficient exchange and use of optical and calorimetric data of glazing units, shading devices, and combinations of both. The paper presents the research questions, an analysis of the current challenges, six design goals for the product data network and its implementation together with a discussion. Many product data sources can be connected to many planning software applications via the specified application programming interface. When planning software connects to the product data network, the planning of building envelopes can be much faster because planners do not need to spend so much time to search and process product data manually. The planning of building envelopes can also become much easier, especially for planners with limited experience. They do not need to understand all the details about which data fits which calculation if the software company implements this. The planning of building envelopes can become much more reliable when software companies validate their use of the product data network, because the current manual process is prone to errors. The planning of building envelopes can also improve because more products can be compared in the available time, allowing better solutions to be found.

Maurer, Christoph↗

The state of the art for neutron irradiation experiments from the perspective of the High Flux Isotope Reactor (HFIR)

Irradiation experiment campaigns are critical to advancing nuclear energy technologies by providing data on material performance under relevant radiation conditions. Successful irradiation experiments require integrated design efforts that balance technical goals with facility constraints. Here, this paper presents an expert-informed overview of irradiation experiment design at the High Flux Isotope Reactor. It addresses the nuclear materials research and irradiation experiment communities to guide them toward developing technically sound, facility-compatible campaigns. The High Flux Isotope Reactor is a multipurpose reactor supporting isotope production, neutron scattering, and materials testing. Its high, steady-state neutron flux is ideal for irradiation experiments, but successful execution demands coordinated thermal, structural, and reactor physics analyses. The paper outlines the complete development workflow from concept definition and design optimization to safety qualification and post-irradiation examination. Standardized capsule platforms are also discussed in terms of flexibility, specimen capacity, and thermal performance. Common failure modes such as unanticipated geometric variations, can impact temperature-dose profiles and compromise data reliability. Therefore, detailed thermal modeling and accurate as-built characterization are essential for meaningful post-irradiation data interpretation. Key recommendations include early engagement all stakeholders, clearly defined design expectations, and alignment of specimen geometries with post-irradiation examination capabilities. This approach reduces design iterations, enhances data quality, and supports more efficient use of irradiation resources. Strategic and well-planned irradiation testing not only improves individual campaign success but also accelerates the deployment of advanced nuclear technologies. By closing critical data gaps and reducing development risks, the nuclear materials community can more effectively contribute to the future of clean, resilient energy systems.

Experiments↗

Tunable analog thermal material

Naturally-occurring thermal materials usually possess specific thermal conductivity ($\textit{κ}$), forming a digital set of $\textit{κ}$ values. Emerging thermal metamaterials have been deployed to realize effective thermal conductivities unattainable in natural materials. However, the effective thermal conductivities of such mixing-based thermal metamaterials are still in digital fashion, i.e., the effective conductivity remains discrete and static. Here, we report an analog thermal material whose effective conductivity can be in-situ tuned from near-zero to near-infinity $\textit{κ}$. The proof-of-concept scheme consists of a spinning core made of uncured polydimethylsiloxane (PDMS) and fixed bilayer rings made of silicone grease and steel. Thanks to the spinning PDMS and its induced convective effects, we can mold the heat flow robustly with continuously changing and anisotropic $\textit{κ}$. Our work enables a single functional thermal material to meet the challenging demands of flexible thermal manipulation. It also provides platforms to investigate heat transfer in systems with moving components.

36 MATERIALS SCIENCE↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗

Novel PBX formulations containing thermally-expandable microspheres for on-demand control of explosive behavior

In this work, we present the formulation and analysis of inert Plastic-Bonded eXplosive (PBX)-surrogates loaded with thermally expandable microspheres (TEMs). TEMs consist of a thermoplastic acrylonitrile shell (10-50 µm diameter) encapsulating an inert low boiling hydrocarbon. Upon heating, the TEMs expand as the shell softens while the hydrocarbon gasifies, increasing the internal pressure and expanding the particle by as much as 120 vol%. We hypothesize that TEM expansion within a PBX will introduce tunable changes in local density and porosity, and ultimately the shock sensitivity. This paper focuses on microstructural analysis of surrogate PBX-TEM formulations, both before and after thermally- induced TEM expansion. The formulations were analyzed by scanning electron microscopy (SEM), ultra-small angle neutron scattering (USANS), and X-ray Computed Tomography (x-ray CT) under various thermal conditions. Evidence suggests that TEM expansion within a PBX is a viable method to impart microstructural changes that are predicted to have a measurable, on-demand effect on the initiation sensitivity. Future work includes development of PBX-TEM formulations with HMX and shock initiation experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessing thermal comfort and participation in residential demand flexibility programs

Residential space-conditioning-based demand flexibility (DF) has become an increasingly sought-after method for demand-side load management to enhance grid reliability and facilitate integration of renewable energy generation. However, predicting the effectiveness and flexibility of residential DF resources is challenging due to the variability in household energy use behaviors. Current estimates show that only 50 % of projected savings from DF resources are actualized due to regulatory, technological, and social barriers. From a household perspective, concerns over thermal comfort during space conditioning-based DF events significantly impact participation decisions. Currently, there is a very limited understanding of how thermal comfort during space-conditioning-based DF events in real-world settings impacts household energy use behaviors and, consequently, the success of DF programs in achieving targeted savings. This paper proposes a method to comprehensively assess the thermal comfort implications of DF strategies and presents results of their impacts on DF event participation decisions and demand savings. Here, the proposed method was applied to a heat pump DF field study in Cordova, Alaska. The study’s key findings are: 1) DF event setpoint offsets that maintain indoor operative temperatures between 18 to 22 °C (65 to 71°F) may be preferred in Cordova, Alaska; 2) Household-level thermal comfort is more sensitive to the duration of the DF event than to the degree of temperature offset from baseline conditions; 3) The delayed impact of changes in indoor operative temperature in response to setpoint offsets, both during and after a DF event, influences occupants’ thermal comfort perceptions and willingness to persistently participate in events. The findings from application of the proposed method can help inform future larger-scale occupant-centric DF programs as it can capture information not readily available through utility and device-level energy use data. Thus, it can supplement these sources and help program administrators develop occupant-centric DF strategies, enabling more accurate predictions of participation rates and savings estimates for space-conditioning-based DF programs.

Demand side management↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Thermally Anisotropic Building Envelope Integration into Panelized Metal Construction: Laboratory Evaluation in Guarded Hot Box

The Thermally Anisotropic Building Envelope (TABE) is an active building envelope system that can exchange thermal energy with a storage medium to reduce the building’s energy demand. TABE redirects thermal energy along thin conductive layers in the building envelope to hydronic loops that are connected to thermal energy storage (TES), where it will be available to offset future energy demand when the conditions are favorable. TABEs can also be connected with a geothermal loop to reduce the building’s heating and cooling loads. Due to the importance of thermally conductive metal layers to TABE function, this technology has potential for easy adoption into panelized metal construction. In this study, we illustrate the construction process of prototype metal panels containing TABE and the laboratory evaluation in Oak Ridge National Laboratory’s rotatable guarded hot box. The thermal performance of the prototype panel was assessed for both baseline and operational cases and the total heat flow extracted from the panel by TABE was quantified.

Howard, Daniel↗

Advanced interface heat exchangers for the Space Station main thermal bus

Future evolution and growth of the Space Station will place increasing demands on the thermal management system by the addition of new payloads and from increased activity in the habitat modules. To meet this need, Creare is developing advanced evaporators, condensors, and single-phase heat exchangers for operation in microgravity. The objective is to achieve a several-fold increase in the heat flux capability of these components, while operating at the same temperature difference as specified for the present interface heat exchangers. Two prototype interface heat exchangers are presently being developed: one to interface the main thermal bus to a payload two-phase ammonia bus, and the other, to interface with the crew module single-phase water loop. The results achieved to date in the development of these heat exchangers are reviewed.

Valenzuela, Javier A.↗

Compounding climate change impacts during high stress periods for a high wind and solar power system in Texas

Power system planning aims at ensuring that sufficient supply- and demand-side assets exist to meet electricity demand at all times. For a Texas electric power system with high wind and solar penetrations, we quantify how climate change will affect supply and demand during three types of high stress periods for the power grid: high demand hours, high net demand hours, and high system ramp hours. We specifically quantify effects on demand, reductions in available thermal capacity (i.e. thermal deratings), wind and solar generation, and net demand. We estimate each using meteorological variables from five climate change projections (2041-2050) assuming Representative Concentration Pathway 8.5 and from a reference period (1996-2005). All five projections indicate that climate change will increase demand by up to 2 GWh during high demand hours (4% of demand in the reference period) and increase net demand by up to 3 GWh during high net demand periods (6% of net demand in the reference period). All five projections also indicate thermal deratings will increase during high demand and net demand periods by up to 2 GWh and high net demand ramps will increase by up to 2 GW. Overall, our results indicate compounding effects of climate change in Texas will necessitate greater investment in peak and flexible capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-lubricating coatings for high-temperature applications

Some present-day aeropropulsion systems impose severe demands on the thermal and oxidative stability of lubricant, bearing, and seal materials. These demands will be much more severe for operational systems around the turn of the century. Solid lubricants with maximum temperature capabilities of about 1100 C are known. Unfortunately, none of the solid lubricants with the highest temperature capabilities are effective below approximately 400 C. However, research shows that silver and stable fluorides, such as calcium and barium fluoride act synergistically to provide lubrication from below room temperature to approximately 900 C. Plasma-sprayed, self-lubricating composite coatings that were developed at Lewis are described. Background information is given on coatings, designed as PS100 and PS101, that contain the solid lubricants in a Nichrome matrix. These coatings have low friction coefficients over a wide temperature range, but they have inadequate wear resistance for some long-duration applications. Wear resistance was dramatically improved in a recently developed coating PS200, by replacing the Nichrome matrix material with metal-bonded chromium carbide containing dispersed silver and calcium fluoride/barium fluoride eutectic (CaF2/BaF2). The lubricants control friction and the carbide matrix provides excellent wear resistance. Successful tests of these coatings are discussed.

Sliney, Harold E.↗

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗