Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anisotropic Thermal Conductivity Oscillations in Relation to the Putative Kitaev Spin Liquid Phase of α-RuCl 3

In the presence of an external magnetic field, the Kitaev model could host either gapped topological anyons or gapless Majorana fermions. In α-RuCl 3 , the gapped and gapless cases are only separated by a 30° rotation of the in-plane magnetic field vector. The presence or absence of the spectral gap is key for understanding the thermal transport behavior in α-RuCl 3 . Here, we study the anisotropy of the oscillatory features of thermal conductivity in α-RuCl 3 . We examine the oscillatory features of thermal conductivities (κ / / a, κ / / b) with fixed external fields and find distinct behavior for the gapped (B / / a) and gapless (B / / b) scenarios. Furthermore, we track the evolution of thermal resistivity (λ α ) and its oscillatory features with the rotation of in-plane magnetic fields from B / / b to B / / a. The thermal resistivity λ(B, φ) displays distinct rotational symmetries before and after the emergence of the field-induced Kitaev spin liquid phase. These results suggest that oscillatory features of thermal conductivity in α-RuCl 3 are closely linked to the putative Kitaev spin liquid phase and its excitations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of silica fouling on nonwetting surfaces

Ground water sources used as coolant fluids in a variety of thermal systems such as heat exchangers and power plant condensers contain silica particles that accrete on heat transfer surfaces over time leading to reduction in thermal performance, a problem that is particularly exacerbated with temperature. Nonwetting superhydrophobic, lubricant-infused, and a new class of solid-infused surfaces introduced in this work are candidates for fouling mitigation, by virtue of their water repellency, but little is known about fouling of silica on the surfaces, especially under dynamic flow conditions and as a function of temperature. This article presents, for the first time, a systematic study of dynamic flow fouling of silica on nonwetting surfaces vis-à-vis conventional copper surface over a temperature range 20–50°C. The mechanism of silica aggregate formation and its adherence to the different surfaces is elucidated by scanning electron microscope (SEM) imaging. Sigmoidal growth model is used to describe the time evolution of fouling thermal resistance and an Arrhenius model is presented for the temperature-dependent increase in the asymptotic fouling resistance on nonwetting and conventional surfaces alike. Lubricant-infused and solid-infused surfaces are shown to reduce fouling thermal resistance by up to 25% and 13%, respectively, compared to a conventional surface, whereas superhydrophobic surfaces lose their non-wettability under flow conditions, leading to an adverse increase in the fouling resistance by up to 13%. Considering the possible lubricant depletion in lubricant-infused surfaces over prolonged exposure to a flowing fluid, solid-infused surfaces present a robust alternative.

42 ENGINEERING↗

Expression of interfacial Seebeck coefficient through grain boundary engineering with multi-layer graphene nanoplatelets

Energy filtering has been a long-sought strategy to enhance a thermoelectric material's figure of merit zT through improving its power factor. Here we show a composite of multi-layer graphene nanoplatelets (GNP) and n-type Mg 3 Sb 2 leads to the expression of an energy filtering like effect demonstrated by an increase in the material's Seebeck coefficient and maximum power factor, without impact on the material's carrier concentration. We analyse these findings from the perspective of a heterogeneous material consisting of grain and grain boundary phases, instead of a more traditional and common analysis that assumes a homogeneously transporting medium. An important implication of this treatment is that it leads to the development of an interfacial Seebeck coefficient term, which can explain the observed increase in the material's Seebeck coefficient. The contribution of this interfacial Seebeck coefficient to the overall Seebeck coefficient is determined by the relative temperature drop across the grain boundary region compared to that of the bulk material. In Te doped Mg 3 Sb 2 we show the introduction of GNP increases the interfacial thermal resistance of grain boundaries, enhancing the contribution of the interfacial Seebeck coefficient arising from grain boundaries to the overall Seebeck coefficient. Without significant detriment to the electrical conductivity this effect results in a net increase in maximum power factor. This increased interfacial thermal resistance also leads to the synergistic reduction of the total thermal conductivity. As a result, we enhance zT of the Mg 3 Sb 2 to a peak value of 1.7 near 750 K. Considering the two-dimensional nature of the grain boundary interface, this grain boundary engineering strategy could be applied to a few thermoelectric systems utilizing various two-dimensional nanomaterials.

42 ENGINEERING↗

Impact of Insulation Strategies of Cross-Laminated Timber Assemblies on Energy Use, Peak Demand, and Carbon Emissions

Cross-Laminated Timber (CLT) panels have many structural benefits but do not have much thermal resistance. We have developed a solution to insulate CLT structures that uses high-performance insulation panels that provide R-values up to R40/inch. The CLT panels are made of layers of wood laminates (three, five, seven or more). The solution replaces some of the wood laminates in the CLT production with the insulation panels in a staggered fashion so that the wood laminates maintain contact throughout the panel, ensuring the CLT panel’s structural integrity. The insulated CLT panels have factory-installed water-resistive barriers reducing the installation time by eliminating installing insulation and water-resistive barriers on site. Per simulations, the CLT/insulation panel achieved code-required insulation levels with commonly available insulation materials. The significance of the thermal mass of CLT/insulation hybrid building envelopes was quantified by comparing the whole building energy performance and peak demand of traditional low mass and CLT wall assemblies resulting in up to 7% reduction in peak demand for cooling in Knoxville, TN, in a multifamily building. Buildings contribute over 40 percent of carbon emissions. The proposed CLT/insulation hybrid building envelope addresses both operational and embodied carbon by having high thermal resistances due to the embedded insulation sections and eliminating the use of high embodied carbon materials such as steel and concrete. The carbon benefit is estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thin hybrid capillary two-phase cooling system

A novel hybrid two-phase cooling system was developed that integrated a mechanically pumped two-phase loop with a capillary-driven two-phase cooling device. The latter cooling mechanism was based on evaporation/boiling from wick structures made by sintering copper particles on the interior surfaces of a copper cold plate. The cold plate provided cooling to two surfaces and each of them included four heaters in series. The novelty of the developed technology was preventing flooding of the evaporator wicks by isolating the evaporation surface from the pumped liquid flow that fed them. This arrangement allowed for a high liquid feed flow rate much greater than would be allowed by a capillary pumped system while maintaining a low thermal resistance at the evaporation surface. Using this approach, the cooling system removed over 850 W with a low pumping power below 1.0 W while using R245fa as the working fluid. The equivalent heat fluxes exceeded 970 W/cm 2 over areas less than 0.12 cm 2 . The measured thermal resistance was as low as 0.09 K-cm 2 /W. The presented thermal management solution enables an increase in the power of high heat flux electronic devices beyond the state-of-the-art.

42 ENGINEERING↗

NRC Multiphysics Analysis Capability Deployment FY21: Part 3

This report details the progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Support for Advanced Non-Light Water Reactors.” The deliverables completed for this report are: Deliverable 1c: the capability to model gas mixtures was added to Pronghorn. A test problem mimicking the conditions achieved in a depressurized loss of forced cooling (DLOFC) event was solved with both RELAP-5 and Pronghorn. Pronghorn employed a finite vol ume method with the Kurganov-Tadmor discretization. The comparison between the mass fraction spatial profiles computed with RELAP-5 and Pronghorn clearly shows the presence of numerical artifacts (i.e., overly diffusive behavior at low Mach numbers). We confirmed that the problem disappears at higher Mach numbers. We recommend future work on the implementation of a low Mach finite volume formulation to better treat low Mach number problems. Deliverable 2a: we demonstrated two approaches to model the radiation/conduction/natural convection heat transfer across a stagnant gas for the PBMR-400 design using Pronghorn. The first approach is based on the net radiation method, which relies on the computation of view factors with the Multiphysics Object-Oriented Simulation Environment (MOOSE) ray tracing capability. The second method is a traditional thermal resistance approach. The test problems include both 2D and 3D geometries. In all cases, the results show very good agreement during a DLOFC transient. This confirms that the faster thermal resistance method produces solutions that are equivalent to the net radiation method for this geometry. Deliverable 3d: we demonstrated the use of the advection kernel for the delayed neutron precursor equation in Griffin with a 2D MSFR model. The results appear physical but further verification is recommended. We also recommend the addition of conjugate heat transfer to compute the temperatures and model the thermomechanic behavior of the reflectors and other structures. Significant memory and performance issues were encountered in the 3D axisymmetric model. Future work is recommended in this area. Task 8g: this task allows multidimensional MOOSE applications to be coupled to system codes (RELAP-7 and SAM). We implemented a faster multiphysics iteration coupling algorithm, which provides an overall 6× acceleration of the 3D-1D coupling of the core multidi- mensional fluid flow solver and the 1D primary and secondary loop model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MURR LEU structural and thermal hydraulics analyses: Part I – Preliminary irradiation thermo-mechanical behavior

The University of Missouri Research Reactor (MURR) is expected to be converted from highly enriched uranium (HEU, ≥ 20 wt% U-235) U-Al x dispersion fuel to low-enriched uranium (LEU, < 20 wt% U-235) with U-10Mo monolithic fuel. This work introduces high-fidelity irradiation thermo–mechanical (T-M) analysis of the MURR LEU focusing on changes in coolant channel gap thickness. Three-dimensional (3D) finite element (FE) models were developed to simulate the irradiation T-M behavior of the MURR LEU element with all 23 curved fuel plates, the two side plates, and the combs. It was shown that channel gap thickness changes were influenced not only by plate thickness variations due to fuel swelling and creep but also by the radial displacement of consecutive MURR LEU plates. Modeling the fuel element assembly captured side plate displacements, which were shown to reduce radial fuel plate displacements towards the convex side. The maximum local radial displacement in the element was predicted at the end of life (EOL) as 23.7 mil (602.0 µm) on the lateral centerline of plate 23 towards the convex side. The maximum stripe-averaged reduction in channel gap thickness, particularly relevant for thermal hydraulics (TH) safety analysis, was calculated as 15.9 mil (403.9 µm) in single-side heated channel 24 (the outermost channel). These results account for the thermal resistance from the oxide build-up on cladding surfaces which was shown to be up to 0.82 mil (20.8 µm) thick. It was demonstrated that accounting for oxide layer thermal resistance led to a 10 °C higher peak fuel temperature and a 4.4 mil (111.8 µm) greater maximum local radial displacement. The impact of the calculated channel gap thickness changes on the MURR LEU TH safety analysis is evaluated in Part II.

Irradiation thermo-mechanical analysis↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Thermal Transport in Polymeric Composites Via Engineered Noncovalent Filler–Polymer Interactions

Understanding thermal transport mechanisms in polymeric composites allows us to expand the boundaries of thermal conductivity in them, either increasing it for more efficient heat dissipation or decreasing it for better thermal insulation. But, these mechanisms are not fully understood. Systematic experimental investigations remain limited. Practical strategies to tune the interfacial thermal resistance (ITR) between fillers and polymers and the thermal conductivity of composites remain elusive. Here, we studied the thermal transport in representative polymer composites, using polyethylene (PE) or polyaniline (PANI) as matrices and graphite as fillers. PANI, with aromatic rings in its backbone, interacts with graphite through strong noncovalent π–π stacking interactions, whereas PE lacks such interactions. We can then quantify how π–π stacking interactions between graphite and polymers enhance thermal transport in composites. PE/graphite and PANI/graphite composites with the same 1.5% filler volume fractions show a ∼22.82% and ∼34.85% enhancement in thermal conductivity compared to pure polymers, respectively. Calculated ITRs in PE/graphite and PANI/graphite are ~6 x 10 -8 m 2 KW -1 and ~1 x 10 -8 m 2 KW -1 , respectively, highlighting how π–π stacking interactions reduce ITR. Molecular dynamics (MD) simulations suggest that π–π stacking interactions between PANI chains and graphite surfaces enhance alignment of PANI's aromatic rings with graphite surfaces. This allows more carbon atoms from PANI chains to interact with graphite surfaces at a shorter distance compared to PE chains. Finally, our work indicates that tuning the π–π stacking interactions between polymers and fillers is an effective approach to reduce the ITR and enhance the thermal conductivity of composites.

atoms↗

Thermal conductivity and its relation to atomic structure for symmetrical tilt grain boundaries in silicon

We perform a systematic study of thermal resistance and conductance of tilt grain boundaries (GBs) in Si using classical molecular dynamics. The GBs studied are naturally divided into three groups according to the structural units forming the GB core. In this work we find that, within each group, the GB thermal conductivity strongly correlates with the excess GB energy. All three groups predict nearly the same GB conductivity extrapolated to the high-energy limit. This limiting value is close to the thermal conductivity of amorphous Si, suggesting similar heat transport mechanisms. While the lattice thermal conductivity decreases with temperature, the GB conductivity slightly increases. However, at high temperatures it turns over and starts decreasing if the GB structure undergoes a premelting transformation. Analysis of vibrational spectra of GBs resolved along different directions sheds light on the mechanisms of their thermal resistance. The existence of alternating tensile and compressive atomic environments in the GB core gives rise to localized vibrational modes, frequency gaps creating acoustic mismatch with lattice phonons, and anharmonic vibrations of loosely bound atoms residing in open atomic environments.

36 MATERIALS SCIENCE↗

Investigation of fouling mechanisms for diesel engine exhaust heat recovery

The effect of diesel engine exhaust fouling on heat and mass exchangers for waste heat recovery is investigated. Experiments are conducted for a range of operating conditions relevant to the use of the waste heat from a diesel engine for powering a 2.71 kW capacity absorption heat pump. Thermal resistances of fouling layers as well as their effects on pressure drop are determined, and the underlying mechanisms for deposition and removal are investigated. Fouling layer effects are most severe for the lowest coolant temperatures and 100% generator load. At these conditions, the fouling thermal resistance is approximately 70% of the total resistance, and the ratio of the steady-state pressure drop to the baseline pressure drop is 3.25. Flow induced shear is found to be the primary growth inhibiting mechanism at high exhaust velocities. Findings from this study can guide heat exchanger design for a variety of waste heat recovery systems.

04 OIL SHALES AND TAR SANDS↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Molecular dynamics simulations of energy accommodation between gases and polymers for ultra-low thermal conductivity insulation

Determining the energy accommodation between gases and solids is essential to developing porous thermal insulation materials with ultra-low effective thermal conductivity that reduce energy use, greenhouse gas emissions, and fossil fuel consumption. The energy accommodation coefficients of most gases, however, have been rarely studied, especially with respect to solids that have relatively high thermal resistivity, e.g., polymers. Here, by using all-atom nonequilibrium molecular dynamics simulations, we reveal the accommodation coefficients of He, Ar, N 2 , and O 2 with polymers, mainly polystyrene. We find that their values are around 0.51, 0.72, 0.79, and 0.90, respectively, suggesting a critical reexamination of the commonly used theoretical maximum value of 1. We have also conducted experiments and validated the value for air, which is about 0.81. Such a change in accommodation coefficients can lead to a reduction of about 70%, 50%, 35%, and 20% in the thermal conductivity of He, Ar, N 2 , and O 2 gases in nano pores (below 100 nm) or at low pressures (below 1 millibar). With these new accommodation coefficients, we find that in a 10 nm pore with ambient pressure at 300 K, the gas thermal conductivity of He, Ar, N 2 , and O 2 in porous polystyrene can be as low as 9.7 × 10 –4 , 3.4 × 10 –4 , 7.3 × 10 –4 , and 8.5 × 10 –4 W·m –1 ·K –1 , respectively, which are two to three orders of magnitude lower than their bulk values, promising higher thermal resistivity of insulation materials. This work reveals the fundamental energy exchange between gases and polymers, providing important guidance for designing high-performance thermal insulation materials for various applications.

36 MATERIALS SCIENCE↗

Mesoscale modeling of microstructure-dependent thermal conductivity in U-Zr fuels

In uranium-zirconium (U-Zr) based metallic fuels, different phases can form at different compositions and temperatures. Typically, lamellar δ-UZr 2 and α-U phases are the dominant microstructures in U-rich U-Zr alloys at temperatures below 880 K. In this work, a finite element method based mesoscale modeling technique is used to calculate the effective thermal conductivities of such heterogeneous microstructures, using the thermal conductivities of two individual phases and their interphase thermal resistance (Kapitza resistance) as input parameters. The Kapitza resistance between δ-UZr 2 and α-U is determined at different temperatures, which shows an approximately T 3 dependence in the temperature range between 300 and 800 K. In addition, the Kapitza resistance exhibits a strong dependence on the aspect ratio of the δ-UZr 2 phase. Further, an analytical model is therefore developed to quantify the effects of both temperature and δ-UZr 2 aspect ratio on the Kapitza resistance. Using this newly developed Kapitza resistance model, the effective thermal conductivities of a number of δ-UZr 2 + α-U heterogeneous microstructures in U-Zr alloys, including non-lamellar microstructures, can be estimated accurately.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗