A tungsten external heater for BX90 diamond anvil cells with a range up to 1700 K

Resistive heating of a sample in a diamond anvil cell (DAC) can generate a homogeneous temperature field across the sample chamber with reliable temperatures measured by a thermocouple. It is of importance in experiments aiming at exploring phase diagrams and quantifying thermoelastic properties of materials. Here, we present a ring-heater design developed for BX90 diamond anvil cells (DACs). Furthermore, it is made of a ring-shaped aluminum oxide holder hosting a tungsten wire coil inside and coupled with Ar + 2% H 2 gas to prevent oxidation during experiment. This modular plug-and-play design enables in situ studies of samples via x-ray diffraction up to a temperature of 1700 K. Temperature in the BX90 sample volume as measured through a thermocouple was calibrated using the melting point of gold. As an application of this design, we report the thermal expansion coefficient of MgO at 9.5(1) GPa.

47 OTHER INSTRUMENTATION↗

Alpert multi-wavelets for functional inverse problems: direct optimization and deep learning

Computational engineering models often contain unknown entities (e.g. parameters, initial and boundary conditions) that require estimation from other measured observable data. Estimating such unknown entities is challenging when they involve spatio-temporal fields because such functional variables often require an infinite-dimensional representation. Here, we address this problem by transforming an unknown functional field using Alpert wavelet bases and truncating the resulting spectrum. Hence the problem reduces to the estimation of few coefficients that can be performed using common optimization methods. We apply this method on a one-dimensional heat transfer problem where we estimate the heat source field varying in both time and space. The observable data is comprised of temperature measured at several thermocouples in the domain. This latter is composed of either copper or stainless steel. The optimization using our method based on wavelets is able to estimate the heat source with an error between 5% and 7%. We analyze the effect of the domain material and number of thermocouples as well as the sensitivity to the initial guess of the heat source. Finally, we estimate the unknown heat source using a different approach based on deep learning techniques where we consider the input and output of a multi-layer perceptron in wavelet form. We find that this deep learning approach is more accurate than the optimization approach with errors below 4%.

97 MATHEMATICS AND COMPUTING↗

Advancing Temperature Monitoring of the Bottom Anode in a Direct Current Electric Arc Furnace Operations with Distributed Optical Fiber Sensors.

The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.

42 ENGINEERING↗

Transient computational and experimental thermal analysis of graphite foam monoblock

A densified graphite foam is being explored for its applicability as plasma-facing material in fusion devices. Three different graphite foam monoblocks are constructed and tested in the Garching Large Divertor Sample Testing Facility. The monoblock samples consist of graphite foam press-fit to a single tube, graphite foam cubes brazed to a single, and graphite foam cubes press-fit to a single tube. The tube is composed of CuCrZr with a steel twisted tape. The monoblocks are exposed to the heat fluxes of 5, 6, and 8 MW/m 2 for 30 s to determine the maximum surface and body temperatures measured with thermocouple for each monoblock design. The press-fit monoblocks are exposed to 8 MW/m 2 for 15 s for 100 cycles to determine the effect of thermal cycling on the contact between the graphite foam and the tube. STAR-CCM+ is used to predict how much the contact between the foam and tubes varies as a result of thermal cycling. In addition, the 6 MW/m 2 loading is modeled in STAR-CCM+ to compare the transient cooldown curves of the computational results to the recorded temperatures at the surface and two different thermocouple locations. This comparison is used to validate the temperature-dependent thermal conductivity and specific heat capacity used in the models of the graphite foam. The computational modeling of the experiment has been used to hypothesize ways to use and improve upon the graphite foam as a suitable material for fusion applications.

Gehrig, Monica↗

Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type

Thermal runaway of lithium-ion batteries can involve various types of failure mechanisms each with their own unique characteristics. Using fractional thermal runaway calorimetry and high-speed radiography, the response of three different geometries of cylindrical cell (18650, 21700, and D-cell) to different abuse mechanisms (thermal, internal short circuiting, and nail penetration) are quantified and statistically examined. Correlations between the geometry of cells and their thermal behavior are identified, such as increasing heat output per amp-hour (kJ Ah −1 ) of cells with increasing cell diameter during nail penetration. High-speed radiography reveals that the rate of thermal runaway propagation within cells is generally highest for nail penetration where there is a relative increase in rate of propagation with increasing diameter, compared to thermal or internal short-circuiting abuse. For a given cell model tested under the same conditions, a distribution of heat output is observed with a trend of increasing heat output with increased mass ejection. Finally, internal temperature measurements using thermocouples embedded in the penetrating nail are shown to be unreliable thus demonstrating the need for care when using thermocouples where the temperature is rapidly changing. All data used in this manuscript are open access through the NREL and NASA Battery Failure Databank.

25 ENERGY STORAGE↗

In situ temperature measurement of a deforming interface with thermoelectricity

Accurate temperature measurement is critical to understanding the thermomechanical conditions and microstructural evolution that materials experience during severe plastic deformation (SPD). Others have previously measured the interface between a non-deforming tool and metal workpiece using thermocouples, infrared measurement, and the thermoelectric principle. Measuring temperature within the deforming material itself, especially at a high-shear deforming interface, has proven to be extremely difficult, thus limiting the application of these measurements to fundamental SPD research. In this study, the thermoelectric principle is used to directly measure temperature at the interface between copper and nickel billets undergoing SPD. This is done by utilizing the deforming materials themselves as two halves of a thermocouple junction. The spatial resolution of this measurement is shown via microscopy to be less than 1 micron. Temperature changes are sensed almost instantly, with time delays on the order of the data logger frequency (0.01 seconds). Process variations that are both very brief (<0.05 seconds) and minute (<3°C) are able to be detected by this method.

Taysom, Brandon Scott↗

An Instrumented Capsule Design to Measure Thermal Conductivity in Miniature UO2 Specimens

Numerous separate effects irradiations of miniature nuclear fuel specimens have been conducted in the High Flux Isotope Reactor (HFIR) under the experimental platform designated as MiniFuel. MiniFuel is a static irradiation capability in which microstructural evolution and fuel performance phenomena are observed during postirradiation examination thereby offering a snapshot of the terminal fuel characteristics. This approach inherently requires fielding an irradiation where the experimental conditions are determined using predictive models and the pertinent outcomes are measured at the end of the test. Static irradiations can provide useful insights to the relationships between fuel performance and the pivotal irradiation conditions, namely temperature and burnup, but the ability to monitor fuel performance in situ would further support fuel development and qualification. To this end, an instrumented experiment design is being developed at Oak Ridge National Laboratory to capture thermal conductivity degradation and fission gas release during HFIR irradiation. These phenomena will be monitored using unique capsule designs that each target a different phenomenon. This paper details the thermal conductivity capsule (TCC) design and its expected performance envelope as determined using computer models. Each TCC will contain a miniature UO2 disc specimen (~0.5 mm thick × 5 mm diameter) sandwiched between metallic slugs with embedded thermocouples. The coupling of in situ temperature measurements, known thermal conductivity of the metallic components, and heat generation rates computed using high-fidelity neutronics models make the thermal conductivity measurement possible. This paper describes the reactor physics and heat transfer models used to predict the capsule’s performance and the methodology for calculating the fuel specimen’s thermal conductivity from the thermocouple measurements.

Gorton, Jacob [ORNL] (ORCID:0000000269806083)↗

Optimizing hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy in nitrogen at high pressures and temperatures

We demonstrate the use of hybrid rotational femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman spectroscopy (HR-CARS) as a technique for temperature measurements in nitrogen gas at high pressures and temperatures. A broadband pulse shaper-adjusted 42 fs pulse interacts with a narrow-bandwidth, frequency-upconverted 5.5 ps pulse in a cell containing N 2 at pressures of 1–70 atm and temperatures of 300–1000 K. A computational code is used to model spectra and fit experimental results to obtain best-fit temperatures. We demonstrate good qualitative fits as well as good accuracy and precision between thermocouple measured and best-fit temperatures over the explored pressure and temperature regimes. The overall average percentage temperature difference between thermocouple measurements and best-fit temperatures is − <#comment/> 0 . 3 % <#comment/> with a standard deviation of 7.1%, showing the suitability of HR-CARS for characterizing high-pressure and -temperature environments.

Torge Mecker, Nils (ORCID:0000000238977170)↗

FY20 Status Report on Creep Rupture Testing to Support the Development of Alloy 709 Code Case

This report provides an update on the status of the creep rupture testing on the first commercial heat of Alloy 709 in support of the Alloy 709 Code Case development. A creep test laboratory has been set up at ANL that comprises of 15 indirectly loaded test frames capable of testing ASTM-size specimens of the commercial heat of Alloy 709. The systems are equipped with high temperature furnaces capable of operation up to 1000°C in an air environment. During FY18, uniaxial ASTM-sized creep specimens were fabricated from 9 Alloy 709 plates that were processed by AOD, ESR, and ESR-homogenized routes and subsequently solution annealed at 1050, 1100, and 1150°C, and creep-rupture tests were performed at 330MPa and 600°C. The test results led to the down selection of the ESR-1100°C condition to support the code case. In FY19, 15 creep-rupture tests of the ESR-1100°C material, requiring the use of Type K thermocouples, were initiated to support the 100,000-hour Code Case. 8 tests were completed in FY19. In FY20, 6 tests were completed at the time of writing this report. In addition, 1 more test were loaded in FY20, using Type S thermocouples, and was completed. This report presents the data from the completed tests in FY20 and also the microstructural characterization of the fractured specimens. The creep data enabled the preliminary analysis of the creep behavior of this material. The characterization showed that in brittle fractures, the pores were narrow and thin, and elongated in the direction perpendicular to the loading direction, while in ductile fractures, the pores were much rounder. Dense precipitates were observed in all the samples, the size of which grew with test temperature. Some of the precipitates could be identified to be M23C6 based on their cuboid shape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry

This work investigated the temperature-sensing capabilities of Type II fiber Bragg gratings (FBGs) inscribed in sapphire optical fiber in the Ohio State University Research Reactor (OSURR). A Luna Innovations 4600 optical backscatter reflectometer (OBR) was used to interrogate FBGs in three sapphire optical fibers with an internal cladding that was developed by Ohio State. The sapphire fibers were fusion-spliced to silica lead fibers. In addition to the sapphire fibers, two silica fibers with the same Type II FBGs were included in the experiment as a reference. The fiber-based sensors were irradiated in the Central Irradiation Facility (CIF) of the OSURR for a total of 40 hours over 5 days at a reactor power of 450 kW, resulting in a total neutron fluence of approximately 2.5 × 10 18 n/cm 2 and a gamma dose of approximately 3.48 Grad. Two K-type thermocouples were included within the rig: one at the core centerline and the other 12 inches above the top of the core. The temperature was not actively controlled, but the thermocouples were used to provide a reference to which the fiber-based temperature measurements could be compared.

36 MATERIALS SCIENCE↗

Performance of Embedded Sensors in 3D Printed SiC

This report summarizes recent advances in embedding sensors in 3D printed silicon carbide (SiC) ceramic components under the Transformational Challenge Reactor (TCR) program. The additive manufacturing technologies developed under this program will enable fabrication of complex structures with embedded fuels and sensors. The sensors will be capable of characterizing fuel performance using spatially distributed measurements at the most strategic locations that would be otherwise inaccessible using conventional manufacturing techniques. While previous programmatic updates describe initial concepts for embedding sensors, materials selection, and initial characterization of the embedded sensors, the technology requires further demonstration, and quality-significant procedures must be established before the embedding technology is ready for adoption by industry. To this end, this report describes the most effective techniques that have been used to embed functional sensors in 3D printed components using a combination of binder-jet additive manufacturing and chemical vapor infiltration (CVI). A detailed procedure describes each step in the process and is available upon request. Molybdenum (Mo)-sheathed thermocouples have been successfully embedded in complex SiC components, and temperatures were monitored in situ during the embedding process. Post-embedding measurements showed no significant hysteresis, and characterization of the interface revealed qualitatively strong bonding around the entire perimeter of the sensor sheath. Distributed fiber-optic temperature sensors were able to briefly measure temperature profiles during CVI, but they ultimately failed prior to completion of the CVI run. The failure appears to be related to the fiber coating at temperatures close to 1,000°C. Future work will focus on irradiation testing of embedded thermocouples and other sheathed electrical sensors, as well as the identification of fiber-optic sensor coatings that can survive CVI.

42 ENGINEERING↗

Characterization of Embedded Sensors in Stainless Steel Test Articles and Design/Planning for MAGNET Testing

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes for heat rejection, which results in significant thermal stresses in the monolithic structures. This work describes the initial characterization and test plan for evaluating stainless steel test articles fabricated with embedded sensors for measuring heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing. The electrically heated testing will be performed in the non-nuclear Microreactor Agile Non-Nuclear Testbed and Single Primary Heat Extraction and Removal Emulator facilities located at Idaho National Laboratory. The goals of these tests are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. More generally, the ability to monitor component and system health during microreactor operation is attractive for providing a high sensor density to inform a limited number of microreactor operators to ultimately reduce operation and maintenance costs and move toward semi-autonomous operation. This report discusses the characterization of embedded thermocouples and fiber optic sensors in relevant test articles, including cylindrical pipes and hexagonal monolithic test articles for heat pipe-based reactors. The sensors were embedded by placing them in machined channels and then building up additional material by using ultrasonic additive manufacturing (UAM). UAM is a solid-state welding process that uses downward pressure and a lateral scrubbing motion to bond thin metal foils to a base material layer by layer. The ultrasonic welding process relies on the plastic deformation of the metal—as opposed to typical melting and solidification—to break oxide scales and bond the metal layers. The characterization of these embedded sensors included evaluating fiber optic signal attenuation, observing residual strain in the fibers, investigating microstructural and mechanical aspects, and demonstrating the sensors under various thermal loads and acoustic vibrations. Post-embedding characterization showed a fine grain structure (<1 μm) near the interfaces of the bonded foils as a result of severe deformation from the welding process. A large increase in hardness was observed at the foil interfaces and the fiber/matrix interface compared with the bulk matrix. Even when compared with the SS304 interfaces, the higher hardness observed around the embedded fiber suggests a higher degree of deformation due to the soft metal coating around the silica fiber core. The distributed fiber-optic temperature sensors and embedded thermocouples reliably measured temperature distributions during steady-state and transient thermal testing. The embedded fiber-optic sensors reliably measured strain during both transient and steady-state testing and properly identified resonant frequencies during acoustic testing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Bottom Anode Monitoring in DC Electric Arc Furnaces Using Fiber-Optic Sensors

A pin style bottom anode employs conductive steel rods that serve as the pathway for the high electrical power through rammed refractory at the bottom of a DC Electric Arc Furnace (EAF). Anode wear during operation is important to monitor, as anode replacement is expensive and impacts EAF productivity. Liquid steel penetration into the un-sintered refractory layer can result from rapid electrical power ramp-up, dips in furnace temperature, or operating the anode for too long between EAF campaigns. In extreme cases, the liquid steel may penetrate the bottom of the furnace when anode wear progresses too close to the bottom shell, which is extremely dangerous and must be avoided. The current state of the art for monitoring bottom anode wear employs thermocouples imbedded in the anode pins at points in the anode. However, this approach is not sensitive enough to detect localized damage to the anode, especially when cracking occurs. Here, the present work utilizes fiber optic sensors to monitor the health of the anode, by creating a real-time spatially distributed temperature map of the anode. Unlike the traditional thermocouples, these sensors can be mounted at significantly greater depths, provide distributed temperature measurements, and can withstand temperatures of up to 900°C. Additionally, they are able to perform temperature measurements with a spatial resolution of 1.3 mm at a 5 Hz acquisition rate, providing unprecedented high-density real time monitoring of anode health and increasing the efficiency, and safety of EAF operation.

Bottom Anode↗

Monitoring of Temperature Measurements for Different Flow Regimes in Water and Galinstan with Long Short-Term Memory Networks and Transfer Learning of Sensors

Temperature sensing is one of the most common measurements of a nuclear reactor monitoring system. The coolant fluid flow in a reactor core depends on the reactor power state. We investigated the monitoring and estimation of the thermocouple time series using machine learning for a range of flow regimes. Measurement data were obtained, in two separate experiments, in a flow loop filled with water and with liquid metal Galinstan. We developed long short-term memory (LSTM) recurrent neural networks (RNNs) for sensor predictions by training on the sensor’s own prior history, and transfer learning LSTM (TL-LSTM) by training on a correlated sensor’s prior history. Sensor cross-correlations were identified by calculating the Pearson correlation coefficient of the time series. The accuracy of LSTM and TL-LSTM predictions of temperature was studied as a function of Reynolds number (Re). The root-mean-square error (RMSE) for the test segment of time series of each sensor was shown to linearly increase with Re for both water and Galinstan fluids. Using linear correlations, we estimated the range of values of Re for which RMSE is smaller than the thermocouple measurement uncertainty. For both water and Galinstan fluids, we showed that both LSTM and TL-LSTM provide reliable estimations of temperature for typical flow regimes in a nuclear reactor. The LSTM runtime was shown to be substantially smaller than the data acquisition rate, which allows for performing estimation and validation of sensor measurements in real time.

Pantopoulou, Stella↗

Impact to Cooling Airflow from Truck Platooning

We investigate tradeoffs between the airflow strategies related to engine cooling and the aerodynamic-enabled fuel savings created by platooning. By analyzing air temperatures, engine temperatures and cooling air flow at different platoon distances, we show the thermal impact to the engine from truck platooning. Previously, we collected wind and thermal data for numerous heavy-duty truck platoon configurations (gaps ranging from 4 to 87 meters) and reported the significant fuel savings enabled by these configurations. The fuel consumption for all trucks in the platoon were measured using the SAE J1321 gravimetric procedure as well as calibrated J1939 instantaneous fuel rate while travelling at 65 mph and loaded to a gross weight of 65,000 lb. Using thermocouples mounted 1 m ahead of each truck, anemometers at the grill and a grid of under-hood thermocouples as well as J1939 reported engine temperatures, we analyze the impact to critical operating temperatures from different platoon configurations. Results show significant changes in the engine and under-hood air temperatures that correlate with vehicle gap distance and platoon position.

adaptive cruise control (ACC)↗

As-run thermal hydraulics analysis of the EPRI-1 Experiment

The EPRI-1 experiment was designed to irradiate various types of reactor pressure vessel steels at a temperature of 288°C (PLN-3934). The specimens were irradiated in an instrumented test train inside a pressurized water loop in the center lobe of the ATR during cycle 157C. Temperature was monitored using thermocouples placed at the top of the test train. Additional temperature indications were obtained by post-irradiation examination of melt wires placed within the test train and spanning the temperature range 239°C to 327°C. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and as-run calculations of heating rates of the test train. The accuracy of the model is assessed by comparing the measured and calculated in-pile tube inlet to outlet temperature difference, comparing the measured and calculated thermocouple temperatures, and comparing the calculated specimen temperature to the temperature range indicated by the melt wires.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact to Cooling Airflow from Truck Platooning: Preprint

We investigate tradeoffs between the airflow strategies related to engine cooling and the aerodynamic-enabled fuel savings created by platooning. By analyzing air temperatures, engine temperatures and cooling air flow at different platoon distances, we show the thermal impact to the engine from truck platooning. Previously, we collected wind and thermal data for numerous heavy-duty truck platoon configurations (gaps ranging from 4 to 87 meters) and reported the significant fuel savings enabled by these configurations. The fuel consumption for all trucks in the platoon were measured using the SAE J1321 gravimetric procedure as well as calibrated J1939 instantaneous fuel rate while travelling at 65 mph and loaded to a gross weight of 65,000 lb. Using thermocouples mounted 1 m ahead of each truck, anemometers at the grill and a grid of under-hood thermocouples as well as J1939 reported engine temperatures, we analyze the impact to critical operating temperatures from different platoon configurations. Results show significant changes in the engine and under-hood air temperatures that correlate with vehicle gap distance and platoon position.