Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermopile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Solar Radiometer Instrumentation Evaluation: Cooperative Research and Development (Final Report, CRADA Number CRD-16-00619)

The purpose and intent of this agreement is to evaluate newly manufactured thermopile pyranometers and spectroradiometers. The purpose also extends to provide a framework for Participant to conduct research to improve and develop new radiometric devices and application in the future. The overall objective is to provide more accurate, site-specific, long-term, continuous measurements of the solar resources needed by industry to increase the deployment and improve the operations of photovoltaic and concentrating solar power plants. This CRADA addresses the needs for proven solar irradiance measurement to validate resource assessment models and generate high quality data used for site selection, energy system design, deployment, maintenance, and operation. This work will be conducted at NREL and Participant facilities. This project will place instrumentation at the NREL Solar Radiation Research Laboratory (SRRL) in cooperation with EKO Instruments, USA. Participant instruments will be deployed for the purpose of evaluation under controlled conditions. The scope of the project will be a 3 years-long segmented comparison of the instruments vs. other NREL baseline instruments with a well-characterized history. These evaluations will include planned improvements to instruments as well as extensions of future instrument applications. The final evaluation will be a written report similar to the work done by Wilcox and Myers (see http://www.nrel.gov/docs/fy09osti/44627.pdf).

14 SOLAR ENERGY↗

PV Reference Cells for Outdoor Use: Comparison of First-Year Field Measurements

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as low-cost alternatives to thermopile pyranometers. But reference cell characteristics, such as directional and spectral response, fundamentally differ from pyranometers, and measurements made by the former cannot be substituted for or directly compared with the latter. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of multiple products from different manufacturers that are mounted at a fixed tilt, on a single-axis tracker, and on a dual-axis tracker. This report provides an analysis of the data collected during the first year of operation at the NREL location. An overall assessment is made by comparing the total energy measured by each instrument to the other instruments having the same orientation. These totals are calculated for three different scenarios: (1) using the factory calibration factors, (2) using the previously determined NREL Cell Lab calibration factors, and (3) using the newly determined field calibration factors derived from the recorded measurements. Because the true or correct measurement values are unknown, pair-wise comparisons are made. The results show that the difference between the highest and lowest measured energy can exceed 3% when using the factory calibration factors. Consistency among instruments improves when Cell Lab calibrations are used, and it further improves when using field calibration factors.

14 SOLAR ENERGY↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Differential input preamplifier

Preamplifier chops and amplifies very low level output of thermopile infrared detectors that will be used to measure thermal energy flux of Jupiter and its departure from a blackbody spectrum. Output signal has negligible phase shift. AC signal is RC-coupled to input stage of other amplifiers.

Callaway, P. W.↗

The repulsive 1 Sigma g/+/ He2 potential obtained from total cross sections

An improved apparatus for obtaining short-range molecular potentials is described. The setup is a refined version of that used by Jordan-Amdur and by Leonas. The ion source is provided with a mass analyzing magnet, the capacitance manometer in the scattering cell is calibrated with a McCleod gauge, and the detection unit substitutes a Channeltron multiplier for the thermopile. The measured ground-state He-He potential for radii between 0.49 and 1.56 A is approximately V(r) = 215 x exp(-3.95r) eV, which is 25% higher than the earlier experiments. The result is supported by molecular orbital and statistical model calculations.

Foreman, P. B.↗

Earth radiation budget measurement from a spinning satellite: Conceptual design of detectors

The conceptual design, sensor characteristics, sensor performance and accuracy, and spacecraft and orbital requirements for a spinning wide-field-of-view earth energy budget detector were investigated. The scientific requirements for measurement of the earth's radiative energy budget are presented. Other topics discussed include the observing system concept, solar constant radiometer design, plane flux wide FOV sensor design, fast active cavity theory, fast active cavity design and error analysis, thermopile detectors as an alternative, pre-flight and in-flight calibration plane, system error summary, and interface requirements.

Sromovsky, L. A.↗

Infrared radiometer for the Pioneer 10 and 11 missions to Jupiter

Pioneer 10 has successfully encountered Jupiter and several of its satellites. The two-channel infrared radiometer used to obtain data relating to thermal properties of the planet and its atmosphere is described. The instrument features a body-fixed, 7.62-cm-diam aperture Cassegrainian telescope with restrahlen filters defining the 14- to 25-micron and 30- to 56-micron bands. Detectors are 88-junction evaporated thin-film thermopiles. Stringent weight constraints of 2 kg dictated all-beryllium construction. Power consumption was 1.2 W.

Bender, M. L.↗

Collection efficiency measurements for solar cell research

A system was established for measuring absolute, spectral collection efficiency that is well suited to solar cell research and development. Determination of spectral collection efficiency involves measurements of the incident photon intensity, the device reflection coefficient, and the cell short circuit current. A monochromatic photon flux is obtained with a high intensity Bausch and Lomb monochromator, and an Epply thermopile detector is used to measure incident intensity. Normal incidence reflectivity measurements are achieved with a prism type beam splitter. The experimental approach is discussed, measurements of the reflectivity of evaporated silver films are considered. Collection efficiency measurements of silicon solar cells are presented, and collection efficiency studies of Cu20 solar cells are discussed.

Hampton, H. L.↗

The self-calibrating sensor of the Eclectic Satellite Pyrheliometer /ESP/ program

A self-calibrating thermopile sensor having a cavity type receiver is described. Its incorporation into pyrheliometric instrumentation, including the electronics and control, is also discussed. Completed devices are capable of solar irradiance measurements with an accuracy to within 0.5% and can detect solar variability to a level approaching 0.001% in space.

Hickey, J. R.↗

Viking infrared thermal mapper

The infrared thermal mapper (IRTM) was designed to measure the emitted and reflected radiance of Mars. Carried by the Viking Orbiter, the IRTM contains four small Cassegrainian telescopes which each image the same, seven circular areas. There is a total of twenty-eight channels in four surface and one atmospheric thermal bands from 6 to 30 microns and a broad solar reflectance band. All channels are sampled simultaneously, using the spacecraft scanning capability to map the radiance over small and large areas of the planet. All channels use thermopile detectors; spectral passbands are determined by a combination of interference filters, detector lense materials, antireflection coatings, and restrahlen optics.

Chase, S. C., Jr.↗

The application of solar thermoelectric generators in near-sun missions

Future planetary near-sun missions, such as those studied for low-altitude Mercury Orbiters, introduce challenges in the selection of appropriate power sources. Study results have shown that conventional silicon solar array technology is not adequate to produce power because of expected temperatures which range from -90 C to +285 C in about 40 to 50 minutes for 16 sun eclipses/day. The solar thermoelectric generator (STG), which requires relatively high temperatures, is being considered as a replacement power source. The complete STG consists of a solar concentrator and multiple thermopiles, each containing numerous thermocouples and thermal insulation material. Articulation of the STG design configurations is required at 0.45 AU to acquire maximum incident radiation and at 0.3 AU to reduce the higher incident radiation. STG thermal input to the spacecraft as it orbits Mercury (including sun eclipses) is insignificant.

Raag, V.↗

Performance analysis of a filtered wide field-of-view radiometer for earth radiation budget measurements

The proposed Earth Radiation Budget Satellite System (ERBSS) of the 1980's will include a wide field-of-view (WFOV) fixed axes earth radiator discriminator consisting of a shortwave channel and a total (unfiltered) channel. The broadband spectral isolation required for the shortwave channel is achieved by use of a hemispherical fused silica (Suprasil W) dome filter placed in front of a wire wound thermopile radiation detector. A description is presented of the thermal response of the single-fused silica dome filter in the ERBSS WFOV shortwave channel conceptual design and the impact of that response on the channel measurement. Results from design definition and performance analysis studies are included. Problems associated with achieving the desired levels of confidence in a high accuracy filtered, WFOV radiometer are discussed. Design approaches, ground calibration, and data reduction techniques which minimize measurement uncertainties are explained.

Cooper, J. E.↗