Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

Enhancing Unknown Waveform Detection by Learning Intra and Inter-domain Dependencies with Advanced Attention Fusion Mechanisms

Detection of unknown waveforms in mission-critical communications is a crucial area of interest for the Department of Energy (DoE). Traditional methods and recent deep learning-based approaches often assume that the training set includes all possible classes, which is impractical for detecting new waveforms. This limitation gives rise to the problem of open-set recognition (OSR), which involves correctly identifying known classes while detecting and rejecting unknown or unseen classes. To address this limitation, we propose a novel dual-domain complex-valued neural architecture that jointly processes time-domain and frequency-domain signal representations using transformer mechanisms. A transformer model is a deep learning architecture that uses self-attention mechanisms to process and learn relationships in sequential data. Our model employs a cosine similarity loss to extract domain-specific features and incorporates a transformer architecture in the latent space to weigh the importance of different features from the time and frequency domains. The transformer layer includes stacked self-attention and cross-attention modules to learn intra-domain and inter-domain dependencies, creating a more holistic signal representation. An attention-based fusion module intelligently combines the time and frequency-domain features using multi-head attention, enabling the network to learn the optimal feature for each domain in each input signal. Quantitative results demonstrate the impact of these architectural choices on overall performance, showing significant improvement after incorporating self and cross-attention modules and using complex attention fusion over simple weighted fusion. Our ongoing work will focus on addressing the limitations of threshold-based OSR methods by developing a novel generative framework that integrates a conditional diffusion probabilistic model (DPM). DPM is a generative framework that learns to synthesize complex data by reversing a gradual noising process using a neural network trained to denoise step-by-step. Our goal is to leverage the inherent strengths of DPMs for identifying unknown signals more robustly. One primary advantage of using a DPM is its ability to provide a more reliable anomaly score based on the model's reconstruction error, rather than relying solely on classifier confidence. Additionally, the iterative denoising process of DPMs makes this approach naturally resilient to low Signal-to-Noise Ratio (SNR) conditions, where traditional methods often fail. By implementing this generative framework, we aim to enhance the model's capability to accurately detect unknown waveforms and maintain performance in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

SU-E-J-191: Automated Detection of Anatomic Changes in H'N Patients

Purpose: To develop a novel statistics-based method for automated detection of anatomical changes using cone-beam CT data. A method was developed that can provide a reliable and automated early warning system that enables a “just-in-time” adaptation of the treatment plan. Methods: Anatomical changes were evaluated by comparing the original treatment planning CT with daily CBCT images taken prior treatment delivery. The external body contour was computed on a given CT slice and compared against the corresponding contour on the daily CBCT. In contrast to threshold-based techniques, a statistical approach was employed to evaluate the difference between the contours using a given confidence level. The detection tool used the two-sample Kolmogorov-Smirnov test, which is a non-parametric technique that compares two samples drawn from arbitrary probability distributions. 11 H'N patients were retrospectively selected from a clinical imaging database with a total of 186 CBCT images. Six patients in the database were confirmed to have anatomic changes during the course of radiotherapy. Five of the H'N patients did not have significant changes. The KS test was applied to the contour data using a sliding window analysis. The confidence level of 0.99 was used to moderate false detection. Results: The algorithm was able to correctly detect anatomical changes in 6 out of 6 patients with an excellent spatial accuracy as early as at the 14th elapsed day. The algorithm provided a consistent and accurate delineation of the detected changes. The output of the anatomical change tool is easy interpretable, and can be shown overlaid on a 3D rendering of the patient's anatomy. Conclusion: The detection method provides the basis for one of the key components of Adaptive Radiation Therapy. The method uses tools that are readily available in the clinic, including daily CBCT imaging, and image co-registration facilities.

60 APPLIED LIFE SCIENCES↗

Denial of Service Attack Detection via Differential Analysis of Generalized Entropy Progressions

Denial-of-Service (DoS) attacks are one the most common and consequential cyber attacks in computer networks. While existing research offers a plethora of detection methods, the issue of achieving scalability, a low false positive rate, and high detection accuracy remains open. In this work, we address this problem by developing a differential method based on generalized entropy progression. In this method, named as DoDGE, we continuously fit the line of best fit to the entropy progression of destination addresses and check if the derivative, that is, the slope of this line is less than the negative of the dynamically computed standard deviation of the derivatives. Furthermore, to distinguish from flash events, we leverage the symmetry that when a flash event occurs, the derivative of the entropy progression of source addresses is positive. With this design, we omit the usage of the thresholds and the results with five real-world network traffic datasets confirm that DoDGE outperforms threshold-based DoS attack detection by two orders of magnitude in terms of false positives on average. When compared to ten machine learning (ML) models, DoDGE achieves a balanced accuracy of 99%, while the average balanced accuracy for the ML models is 52%. Moreover, the results show that DoDGE successfully differentiates between a flash event and a DoS attack. Furthermore, since the main computation cost of DoDGE is the entropy computation, which is linear in the volume of the unit-time network flow, uses integer only operations, and works on a small fraction of the total flow, it is lightweight and scalable.

Cybersecurity, wireless communication↗

Large area photodetector based on microwave cavity perturbation techniques

We present a preliminary study to develop a large area photodetector, based on a semiconductor crystal placed inside a superconducting resonant cavity. Laser pulses are detected through a variation of the cavity impedance, as a consequence of the conductivity change in the semiconductor. A novel method, whereby the designed photodetector is simulated by finite element analysis, makes it possible to perform pulse-height spectroscopy on the reflected microwave signals. We measure an energy sensitivity of 100 fJ in the average mode without the employment of low noise electronics and suggest possible ways to further reduce the single-shot detection threshold, based on the results of the described method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solving The Long-Standing Problem Of Nuclear Reactions At The Highest Microscopic Level: Annual Continuation And Progress Report

The aim of this project is to develop a comprehensive framework that will lead to a fundamental description of both structural properties and reactions of light nuclei in terms of constituent protons and neutrons interacting through nucleon-nucleon (NN) and three-­nucleon (NNN) forces. This project will provide the research community with the theoretical and computational tools that will enable: (1) an accurate prediction for fusion reactions that power stars and Earth-­based fusion facilities; (2) an improved description of the spectroscopy of exotic nuclei, including light Borromean systems; and (3) a fundamental understanding of the three-­nucleon force in nuclear reactions and nuclei at the drip line. To achieve this goal, we build upon a promising technique emerged recently as a candidate to reach a fundamental description of low-­energy binary reactions between light ions, that is the ab initio no-­core shell model combined with the resonating-­group method (NCSM/RGM). This approach has demonstrated the capability to describe binary reactions below the three-­body breakup threshold based, up to now, on similarity-­renormalization-­group (SRG) 5 evolved NN only potentials. To advance the understanding of nuclear reactions at low energies and light exotic nuclei, this project aims at extending the NCSM/RGM approach to include the full range of NNN interactions as well as the treatment of three-­cluster bound and continuum states. Three-­nucleon interactions are unavoidable components of a fundamental nuclear Hamiltonian obtained in a low-­energy effective theory. In addition, three-­nucleon force terms are induced by the SRG procedure and have to be taken into account for such a transformation to be unitary in many-­body calculations. At the same time, the introduction of three-­body cluster states is key to achieve a microscopic description of Borromean systems as well as three-­body breakup reactions. This project will both enhance the fundamentality and enlarge the scope of our microscopic description of nuclear properties. A successful completion of this project will result in improved accuracy of the 3 He( 3 He,2p) 4 He and 3 He(α,γ) 7 Be reaction rates and consequently, in enhancement of the predictive capability of the standard solar model. In addition, we will study also the mirror reactions 3 H( 3 H,2n) 4 He and 3 H(α,γ) 7 Li (a key reaction for the production of 7 Li in the standard big-­bang nucleosynthesis), and the spectroscopy of the 6 He, 6 Be, and 11 Li nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A plasma–vacuum interface tracking algorithm for magnetohydrodynamic simulations of coaxial plasma accelerators

The resistive Magneto-hydrodynamic (MHD) model describes the behavior of a strongly ionized plasma in the presence of external electric and magnetic fields. For problems involving the plasma with an open boundary to very low pressure/vacuum regions, the continuum assumption is no longer valid in the entire domain of interest. For example, this is seen in a plasma accelerator where a dense plasma expands into a vacuum background. A common practice to deal with this issue is to assign small values of density and pressure to the vacuum regions and proceed to solve the continuum based MHD equations throughout the domain. We show that this approach fails to produce solutions consistent with the physics of the problem and can give rise to unacceptable artifacts such as spurious shocks. Here, we develop a plasma–vacuum interface tracking approach to mitigate this problem. The plasma–vacuum interface is tracked in a physically consistent manner and the MHD equations are solved only in the regions that contain the plasma. The interface tracking is achieved using a face-flux formulation derived from the theoretical solution to a 1D free expansion problem. Coupled with a threshold based approach, the interface tracking is implemented for both explicit and implicit time stepping frameworks on generalized unstructured grids. Simulations of magnetized thermal plasma jets expanding into a vacuum background indicate plume profiles devoid of the unphysical shock obtained using the small background density approach. In the context of resistive MHD simulations, the interface tracking approach overcomes the numerical stiffness induced by specifying a large background resistivity in the vacuum regions, resulting in significant wall-clock time gains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced spectroscopic synchrotron techniques to unravel the intrinsic properties of dilute magnetic oxides : the case of Co:ZnO.

The use of synchrotron-based spectroscopy has revolutionized the way we look at matter. X-ray absorption spectroscopy (XAS) using linear and circular polarized light offers a powerful toolbox of element-specific structural, electronic and magnetic probes that is especially well suited for complex materials containing several elements. We use the specific example of Zn{sub 1-x}Co{sub x}O (Co:ZnO) to demonstrate the usefulness of combining these XAS techniques to unravel its intrinsic properties. We demonstrate that as long as phase separation or excessive defect formation is absent, Co:ZnO is paramagnetic. We can establish quantitative thresholds based on four reliable quality indicators using XAS; samples that show ferromagnet-like behaviour fail to meet these quality indicators, and complementary experimental techniques indeed prove phase separation. Careful analysis of XAS spectra is shown to provide quantitative information on the presence and type of dilute secondary phases in a highly sensitive, non-destructive manner.

43 PARTICLE ACCELERATORS↗

Correction of quantification errors in pelvic and spinal lesions caused by ignoring higher photon attenuation of bone in [{sup 18}F]NaF PET/MR

Purpose: MR-based attenuation correction (MRAC) in routine clinical whole-body positron emission tomography and magnetic resonance imaging (PET/MRI) is based on tissue type segmentation. Due to lack of MR signal in cortical bone and the varying signal of spongeous bone, standard whole-body segmentation-based MRAC ignores the higher attenuation of bone compared to the one of soft tissue (MRAC{sub nobone}). The authors aim to quantify and reduce the bias introduced by MRAC{sub nobone} in the standard uptake value (SUV) of spinal and pelvic lesions in 20 PET/MRI examinations with [{sup 18}F]NaF. Methods: The authors reconstructed 20 PET/MR [{sup 18}F]NaF patient data sets acquired with a Philips Ingenuity TF PET/MRI. The PET raw data were reconstructed with two different attenuation images. First, the authors used the vendor-provided MRAC algorithm that ignores the higher attenuation of bone to reconstruct PET{sub nobone}. Second, the authors used a threshold-based algorithm developed in their group to automatically segment bone structures in the [{sup 18}F]NaF PET images. Subsequently, an attenuation coefficient of 0.11 cm{sup −1} was assigned to the segmented bone regions in the MRI-based attenuation image (MRAC{sub bone}) which was used to reconstruct PET{sub bone}. The automatic bone segmentation algorithm was validated in six PET/CT [{sup 18}F]NaF examinations. Relative SUV{sub mean} and SUV{sub max} differences between PET{sub bone} and PET{sub nobone} of 8 pelvic and 41 spinal lesions, and of other regions such as lung, liver, and bladder, were calculated. By varying the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}, the authors investigated its influence on the reconstructed SUVs of the lesions. Results: The comparison of [{sup 18}F]NaF-based and CT-based bone segmentation in the six PET/CT patients showed a Dice similarity of 0.7 with a true positive rate of 0.72 and a false discovery rate of 0.33. The [{sup 18}F]NaF-based bone segmentation worked well in the pelvis and spine. However, it showed artifacts in the skull and in the extremities. The analysis of the 20 [{sup 18}F]NaF PET/MRI examinations revealed relative SUV{sub max} differences between PET{sub nobone} and PET{sub bone} of (−8.8% ± 2.7%, p = 0.01) and (−8.1% ± 1.9%, p = 2.4 × 10{sup −8}) in pelvic and spinal lesions, respectively. A maximum SUV{sub max} underestimation of −13.7% was found in lesion in the third cervical spine. The averaged SUV{sub mean} differences in volumes of interests in lung, liver, and bladder were below 3%. The average SUV{sub max} differences in pelvic and spinal lesions increased from −9% to −18% and −8% to −17%, respectively, when increasing the assigned bone attenuation coefficient from 0.11 to 0.13 cm{sup −1}. Conclusions: The developed automatic [{sup 18}F]NaF PET-based bone segmentation allows to include higher bone attenuation in whole-body MRAC and thus improves quantification accuracy for pelvic and spinal lesions in [{sup 18}F]NaF PET/MRI examinations. In nonbone structures (e.g., lung, liver, and bladder), MRAC{sub nobone} yields clinically acceptable accuracy.

60 APPLIED LIFE SCIENCES↗

Determination of nuclear radii for unstable states in {sup 12}C with diffraction inelastic scattering

We propose a method for determining the nuclear radii for the excited states lying above the particle breakup threshold based on the diffraction model of scattering. The method is applied to analyzing the diffraction structure of the elastic and inelastic scattering of {sup 2}He, {sup 3}He, {sup 4}He, {sup 6}Li, and {sup 12}C ions on {sup 12}C at energies below 100 MeV/A. We study the radii of {sup 12}C in the excited states up to E{sub x}{approx_equal}11 MeV and show that the diffraction radii for the ground and the first 2{sup +} (4.44 MeV) excited states are approximately the same. The diffraction radii for the 0{sub 2}{sup +} (7.65 MeV) Hoyle state and 3{sup -} (9.64 MeV) states located above the {sup 12}C {yields}3{alpha} threshold are larger by {approx_equal}0.5 fm. This difference does not depend on the energy or on the kind of projectiles (deuterons are an exception). This fact justifies an application of the proposed method to the determination of the root-mean-square radii of the above-threshold states. We found that the rms radii for the 0{sub 2}{sup +} (7.65 MeV) and 3{sup -} (9.64 MeV) states are a factor of 1.2 larger than the rms radius for the ground state of {sup 12}C. Also, we estimated the rms radii for the above-threshold 2{sup +} (9.9 MeV), 0{sup +} (10.3 MeV), and 1{sup -} (10.84 MeV) states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

APPLICATION OF BAYESIAN AND GEOSTATISTICAL MODELING TO THE ENVIRONMENTAL MONITORING OF CS-137 AT THE IDAHO NATIONAL LABORATORY

At the Idaho National Laboratory (INL) Cs-137 concentrations above the U.S. Environmental Protection Agency risk-based threshold of 0.23 pCi/g may increase the risk of human mortality due to cancer. As a leader in nuclear research, the INL has been conducting nuclear activities for decades. Elevated anthropogenic radionuclide levels including Cs-137 are a result of atmospheric weapons testing, the Chernobyl accident, and nuclear activities occurring at the INL site. Therefore environmental monitoring and long-term surveillance of Cs-137 is required to evaluate risk. However, due to the large land area involved, frequent and comprehensive monitoring is limited. Developing a spatial model that predicts Cs-137 concentrations at unsampled locations will enhance the spatial characterization of Cs-137 in surface soils, provide guidance for an efficient monitoring program, and pinpoint areas requiring mitigation strategies. The predictive model presented herein is based on applied geostatistics using a Bayesian analysis of environmental characteristics across the INL site, which provides kriging spatial maps of both Cs-137 estimates and prediction errors. Comparisons are presented of two different kriging methods, showing that the use of secondary information (i.e., environmental characteristics) can provide improved prediction performance in some areas of the INL site.

54 ENVIRONMENTAL SCIENCES↗

A novel coupling of noise reduction algorithms for particle flow simulations

Proper orthogonal decomposition (POD) and its extension based on time-windows have been shown to greatly improve the effectiveness of recovering smooth ensemble solutions from noisy particle data. However, to successfully de-noise any molecular system, a large number of measurements still need to be provided. In order to achieve a better efficiency in processing time-dependent fields, we have combined POD with a well-established signal processing technique, wavelet-based thresholding. In this novel hybrid procedure, the wavelet filtering is applied within the POD domain and referred to as WAVinPOD. The algorithm exhibits promising results when applied to both synthetically generated signals and particle data. In this work, the simulations compare the performance of our new approach with standard POD or wavelet analysis in extracting smooth profiles from noisy velocity and density fields. Numerical examples include molecular dynamics and dissipative particle dynamics simulations of unsteady force- and shear-driven liquid flows, as well as phase separation phenomenon. Simulation results confirm that WAVinPOD preserves the dimensionality reduction obtained using POD, while improving its filtering properties through the sparse representation of data in wavelet basis. This paper shows that WAVinPOD outperforms the other estimators for both synthetically generated signals and particle-based measurements, achieving a higher signal-to-noise ratio from a smaller number of samples. The new filtering methodology offers significant computational savings, particularly for multi-scale applications seeking to couple continuum informations with atomistic models. It is the first time that a rigorous analysis has compared de-noising techniques for particle-based fluid simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-J-211: Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

Purpose: X-ray scatter photons result in significant image quality degradation of cone-beam CT (CBCT). Measurement based algorithms using beam blocker directly acquire the scatter samples and achieve significant improvement on the quality of CBCT image. Within existing algorithms, single-scan and stationary beam blocker proposed previously is promising due to its simplicity and practicability. Although demonstrated effectively on tabletop system, the blocker fails to estimate the scatter distribution on clinical CBCT system mainly due to the gantry wobble. In addition, the uniform distributed blocker strips in our previous design results in primary data loss in the CBCT system and leads to the image artifacts due to data insufficiency. Methods: We investigate the motion behavior of the beam blocker in each projection and design an optimized non-uniform blocker strip distribution which accounts for the data insufficiency issue. An accurate scatter estimation is then achieved from the wobble modeling. Blocker wobble curve is estimated using threshold-based segmentation algorithms in each projection. In the blocker design optimization, the quality of final image is quantified using the number of the primary data loss voxels and the mesh adaptive direct search algorithm is applied to minimize the objective function. Scatter-corrected CT images are obtained using the optimized blocker. Results: The proposed method is evaluated using Catphan@504 phantom and a head patient. On the Catphan©504, our approach reduces the average CT number error from 115 Hounsfield unit (HU) to 11 HU in the selected regions of interest, and improves the image contrast by a factor of 1.45 in the high-contrast regions. On the head patient, the CT number error is reduced from 97 HU to 6 HU in the soft tissue region and image spatial non-uniformity is decreased from 27% to 5% after correction. Conclusion: The proposed optimized blocker design is practical and attractive for CBCT guided radiation therapy. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)

60 APPLIED LIFE SCIENCES↗

Initial development of an RIA envelope for dispersed nuclear fuel

A reactivity insertion accident (RIA) is a design basis accident in which reactivity is rapidly injected as a result of a control rod ejection or blade drop scenario. The resultant power increase can result in fuel rod failure and subsequent release of radioactive material into the reactor’s primary system. For light water reactors, failure under RIAs is typically a result of fuel melt, pellet-cladding interaction, or rod over-pressurization. Fuel melt occurs when the fuel system is unable to transport heat out of the fuel system. Pellet-cladding interaction occurs when an aggressive fuel pellet expansion pushes on an embrittled cladding beyond its strain limit. Rod over-pressurization occurs when a fuel rod exceeds the critical heat flux and departs from nucleate boiling, causing the rod internal pressure to rapidly increase, exceeding the systems pressure, and balloon until it bursts. To prevent failure, regulators have developed safety requirements that limit the injected enthalpy based on the state of the fuel system. However, dispersed fuel could enable the removal or relaxation of regulator-imposed safety criteria. Dispersed fuel embeds fuel particles in a highly conductive metal. Dispersed particles can have a particle radius of 1 µm to greater than 100 µm. Traditional fuel systems are plagued by poor thermal conductivity, especially at higher burnups, thus reducing the ability of the fuel system to respond to an RIA. However, dispersed fuel could improve the ability of the fuel system to transport injected energy away from the fissile material and into the coolant more efficiently. Furthermore, dispersing the fuel particles mitigates hard contact that typically occurs in the traditional zirconium-uranium dioxide fuel system, thus removing pellet-cladding mechanical interaction as a potential failure mechanism. This paper evaluates fuel particles dispersed in a metal matrix using the BISON fuel performance code to develop an initial failure threshold based on melt temperature of the fuel particle and/or cladding material as a function of fission density for beginning-of-life and end-of-life conditions. BISON results show that (1) reducing the size of the particles allows fission density to increase as a function of time, (2) particle-to-particle proximity must be considered to evaluate the limiting conditions, and (3) improving the fuel particle thermal conductivity improves thermal performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser-Driven Megavolt X-Ray and Neutron Source Optimization

This 4-month feasibility study assessed the options, trade-offs and major issues in using National Ignition Facility (NIF) and Advanced Radiographic Capability (ARC)-class laser beams for multipulse MeV x-ray and neutron radiography of high explosives (HE) driven experiments. It was performed in close collaboration with a second FS evaluating future HE radiography requirements and expected laser-based source data quality with respect to existing and alternate radiography sources. The study first reviewed the existing published data on MeV x-ray and neutron sources compared to requirements on yield (10 14 /sr for X-rays, > 10 13 /sr for neutrons), spot size (< 1 mm) and duration (< 20 ns). For MeV neutron sources, the preferred options are DTfilled exploding pusher targets or stagnating DT plasmas, each source requiring 50 kJ level. few ns beam irradiation at 0.5 or 0.35 micron wavelength. The preferred X-ray MeV source option to be fully assessed by a follow-up SI is an angularly and temporally-multiplexed multi-burst version of a Bremsstrahlung source (Courtois et al. 2011) irradiated by up to 7 10 ps, kJ-class 1 micron wavelength lasers beams. This multi-burst laser mode, submitted as an ROI and patent, should increase final laser optics damage energy thresholds based on 2 pulse tests and hence allow near full extraction of the 15 kJ of 1 micron laser energy available on a NIF beamline. Hydrodynamic simulations were used to evaluate the effects of preceding pulse irradiation on target integrity, and show that this can be mitigated by using 3D structured targets.

47 OTHER INSTRUMENTATION↗

Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources

We propose a radiation detection system which generates its own discrete sampling distribution based on past measurements of background. The advantage to this approach is that it can take into account variations in background with respect to time, location, energy spectra, detector-specific characteristics (i.e. different efficiencies at different count rates and energies), etc. This would therefore be a 'machine learning' approach, in which the algorithm updates and improves its characterization of background over time. The system would have a 'learning mode,' in which it measures and analyzes background count rates, and a 'detection mode,' in which it compares measurements from an unknown source against its unique background distribution. By characterizing and accounting for variations in the background, general purpose radiation detectors can be improved with little or no increase in cost. The statistical and computational techniques to perform this kind of analysis have already been developed. The necessary signal analysis can be accomplished using existing Bayesian algorithms which account for multiple channels, multiple detectors, and multiple time intervals. Furthermore, Bayesian machine-learning techniques have already been developed which, with trivial modifications, can generate appropriate decision thresholds based on the comparison of new measurements against a nonparametric sampling distribution. (authors)

97 MATHEMATICS AND COMPUTING↗

WE-G-204-04: Focal Spot Deblurring For High Resolution Amorphous Selenium (aSe) Complementary Metal Oxide Semiconductor (CMOS) X-Ray Detector

Purpose: CMOS-based aSe detectors compared to CsI-TFT-based flat panels have the advantages of higher spatial sampling due to smaller pixel size and decreased blurring characteristic of direct rather than indirect detection. For systems with such detectors, the limiting factor degrading image resolution then becomes the focal-spot geometric unsharpness. This effect can seriously limit the use of such detectors in areas such as cone beam computed tomography, clinical fluoroscopy and angiography. In this work a technique to remove the effect of focal-spot blur is presented for a simulated aSe detector. Method: To simulate images from an aSe detector affected with focal-spot blur, first a set of high-resolution images of a stent (FRED from Microvention, Inc.) were acquired using a 75µm pixel size Dexela-Perkin-Elmer detector and averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur at two different magnifications to simulate an idealized focal spot. The blurred images were then deconvolved with a set of different Gaussian blurs to remove the effect of focal-spot blurring using a threshold-based, inverse-filtering method. Results: The blur was removed by deconvolving the images using a set of Gaussian functions for both magnifications. Selecting the correct function resulted in an image close to the original; however, selection of too wide a function would cause severe artifacts. Conclusion: Experimentally, focal-spot blur at different magnifications can be measured using a pin hole with a high resolution detector. This spread function can be used to deblur the input images that are acquired at corresponding magnifications to correct for the focal spot blur. For CBCT applications, the magnification of specific objects can be obtained using initial reconstructions then corrected for focal-spot blurring to improve resolution. Similarly, if object magnification can be determined such correction may be applied in fluoroscopy and angiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extrapolating Contaminant Effects from Individuals to Populations: A Case Study on Nanoparticle Toxicity to Daphnia Fed Environmentally Relevant Food Levels

Ecological risk assessment (ERA) is charged with assessing the likelihood a chemical will have adverse environmental or ecological effects. When assessing the risk of a potential contaminant to biological organisms, ecologists are most concerned with the sustainability of populations of organisms, rather than protecting every individual. However, ERA most commonly relies on data on the effect of a potential contaminant on individuals because these experiments are more feasible than costly population-level exposures. In this work, we address the challenge of extrapolating these individual-level results to predict population-level effects. Previous per-capita population growth rate estimates calculated from individual-level exposures of Daphnia pulicaria to silver nanoparticles (AgNPs) at different food rations predict a critical daily food requirement for daphnid populations exposed to 200 μg/L AgNPs to avoid extinction. To test this, we exposed daphnid populations to the same AgNP concentration at three different food inputs, with the lowest ration close to the extinction threshold predicted from data on individuals. The two populations with the higher food inputs persisted, and the population with the lowest food input went extinct after 50 days but did persist through two generations. Further, we demonstrate that we can extrapolate between these levels of biological organization by parameterizing an individual-level biomass model with data on individuals’ response to AgNPs and using these parameters to predict the outcome for control and AgNP-exposed populations. Key to successful extrapolation is careful modeling of temporal changes in resource density, driven by both the experimental protocols and feedback from the consumer. The implication for ecotoxicology is that estimates of extinction thresholds based on studies of individuals may be reliable predictors of population outcomes, but only with careful treatment of resource dynamics.

54 ENVIRONMENTAL SCIENCES↗