At least 91 records · Page 5

Fourier waveform analyzer

Real-time Fourier analysis is provided by "bucket brigade' charge-transfer shift register. Device is small, inexpensive integrated circuit which does analog-to-digital-to-analog conversion, data processing, and time delay.

Sutton, J. F.↗

Reconfigurable Microwave Phase Delay Element for Frequency Reference and Phase-Shifter Applications

A technique was developed to provide a reconfigurable high-precision micro - wave electrical phase delay for resonators and phase shifters. The invention employs multiple branches of transmission lines with open-ended or ground-ended terminations as configurable bits or digits. This technique minimizes the errors due to limited precision of switching devices. In addition, the proposed linear analytical approach significantly produces a much simpler design than that of other prior inventions at the time of this reporting. Microwave components such as filters, phase delay elements, or resonators require a method that can accurately adjust their frequency responses. Most tuning techniques offer very wide frequency tuning range; however, it is often difficult and expensive to tune their response in a very narrow operating frequency, especially when the tuning element reaches its minimum discrete step due to fabrication tolerances. The problem becomes worse as the operating frequency is in mm-wave frequency range (>26 GHz). The electrical tuning sensitivity of a microwave line is dependent on the position of the tuning element with respect to the reference termination. By placing this tuning element away from this reference with the main transmission line connecting the two elements together the sensitivity of the tuning element can change significantly. This concept can be used in the system that requires multiple tuning sensitivities. In this case, multiple tuning branches are superimposed in the main transmission line. The proposed invention allows the transmission-line electrical length to be accurately programmed using switching elements that have limited accuracy. The invention consists of multiple branches of transmission lines connected to discrete switching devices with open-ended terminations. They are used as discrete tuning elements. These elements are connected to the main microwave transmission line and are separated by a well-defined electrical degree spacing. Each branch is programmed to have different electrical degree sensitivity, such as a combination of discrete steps in each branch, which results in a reflective line with a unique effective phase response. To reduce the number of switching devices, it is desirable to program the devices in binary configuration where each branch represents one bit in the base-2 number system. This invention allows the transmission line electrical length to be tuned precisely with customizable sensitivity based on the known sensitivity of the base tuning circuit. The tuning resolution is dependent on the distance among tuning branches.

Hsieh, Wen-Ting↗

Learning compact physics‐aware delayed photocurrent models using dynamic mode decomposition

Abstract Radiation‐induced photocurrent in semiconductor devices can be simulated using complex physics‐based models, which are accurate, but computationally expensive. This presents a challenge for implementing device characteristics in high‐level circuit simulations where it is computationally infeasible to evaluate detailed models for multiple individual circuit elements. In this work we demonstrate a procedure for learning compact delayed photocurrent models that are efficient enough to implement in large‐scale circuit simulations, but remain faithful to the underlying physics. Our approach utilizes dynamic mode decomposition (DMD), a system identification technique for learning reduced‐order discrete‐time dynamical systems from time series data based on singular value decomposition. To obtain physics‐aware device models, we simulate the excess carrier density induced by radiation pulses by solving numerically the ambipolar diffusion equation, then use the simulated internal state as training data for the DMD algorithm. Our results show that the significantly reduced‐order delayed photocurrent models obtained via this method accurately approximate the dynamics of the internal excess carrier density—which can be used to calculate the induced current at the device boundaries—while remaining compact enough to incorporate into larger circuit simulations.

Hanson, Joshua↗

Map synchronization in optical communication systems

The time synchronization problem in an optical communication system is approached as a problem of estimating the arrival time (delay variable) of a known transmitted field. Maximum aposteriori (MAP) estimation procedures are used to generate optimal estimators, with emphasis placed on their interpretation as a practical system device, Estimation variances are used to aid in the design of the transmitter signals for best synchronization. Extension is made to systems that perform separate acquisition and tracking operations during synchronization. The closely allied problem of maintaining timing during pulse position modulation is also considered. The results have obvious application to optical radar and ranging systems, as well as the time synchronization problem.

Gagliardi, R. M.↗

Evaluation of Fairchild's Gate Drive Optocoupler, Type FOD3150, Under Wide Temperature Operation

An optocoupler is a semiconductor device that is used to transfer a signal between different parts of a circuit that need to be electrically isolated from one another - for example, where a high voltage is to be switched with a low voltage control signal. Optocouplers often can be used in place of relays. These optocouplers utilize an infrared LED (light emitting diode) and a photodetector such as a silicon controlled rectifier or photosensitive silicon diode for the transfer of the electronic signal between components of a circuit by means of a short optical transmission channel. For maximum coupling, the wave-length responses of the LED and the detector should be very similar. In switch-mode power supply applications, optocouplers offer advantages over transformers by virtue of simpler circuit design, reduced weight, and DC coupling capability. The effects of extreme temperature exposure and thermal cycling on the performance of a commercial-off-the-shelf (COTS) optocoupler, Fairchild FOD3150, were evaluated in this work. This 1.0 A output current, high noise immunity gate drive optocoupler utilizes an aluminum gallium arsenide (AlGaAs) LED, is capable of driving most 800V/20A IGBT/MOSFETs, and is suited for fast switching in motor control inverter applications and high performance power systems. Some of the specifications of the isolator chip are listed. The device was evaluated in terms of output response, output rise (t(sub r)) and fall times (t(sub f)), and propagation delays (using a 50% level between input and output during low to high (t(sub PLH)) and high to low (t(sub PLH)) transitions). The output supply current was also obtained. These parameters were recorded at various test temperatures between -190 C and +110 C.

Patterson, Richard↗

Companion Assisted Software Based Remote Attestation in SCADA Networks

Critical infrastructure such as power generation and water distribution systems have become a priority target in cyber warfare because of their recent computerization and introduction to the internet. As a result, Supervisory Control and Data Acquisition (SCADA) system security has become a hot topic in academic and industrial research. Among these topics, Remote Attestation is a security method intended to detect the presence of fileless malware in remote devices as they continue to operate. This allows for the detection of malware in the absence of long-term storage artifacts before symptoms of compromise begin to appear. In general, a trusted device (the verifier) makes a request for evidence of innocence from the untrusted device (the prover). In software-based schemes, the verifier can then measure the delay between its request and the prover’s response. If this delay is greater than the known computational time of the evidence gathering algorithm performed by the prover, then evidence may have been forged. Multi-hop networks often introduce too much network jitter to allow accurate measurement of prover response time, which limits the effectiveness of software based Remote Attestation in a real-world setting. In this work, we introduce a companion device that the verifier can trust to perform a subset of attestation, thereby removing any network jitter. This device is a Field Programmable Gate Array (FPGA) that is physically connected to the prover. We provide a communication protocol between the verifier, prover, and companion. To evaluate our scheme, we simulate it in a common SCADA network environment under normal and heavy traffic loads. Our simulations are performed in the discrete event network simulator NS-3, and we perform statistical analysis over our results to show that our scheme allows for tight timing constraints to be placed on the prover such that the verifier can more easily determine the validity of the evidence that it receives.

Johnson, William A.↗

Infrascope: Full-Spectrum Phonocardiography With Automated Signal Analysis Report

Physicians have used the stethoscope to listen to heart sounds for over 150 years. During this time the stethoscope has remained nearly unchanged. While the device is inexpensive, simple and easy to use, it has shortcomings as a diagnostic tool. It is dependent on human hearing to detect the complex sounds made by the heart, and human memory to analyze them. There also has been a significant decline in the use of stethoscope, at least in part because of the availability of technologies such as the echocardiogram, which can provide imaging and blood flow through the heart chambers. However, echocardiography can be complex, costly and time consuming and requires the need for a specialist, all of which delay the diagnosis and increase the cost of patient evaluation. Even with the availability of echocardiogram devices such as the handheld pocket ultrasound, diagnosing heart problems can still be difficult. The Infrascope is a new device that resembles a traditional stethoscope and is simple to use. In addition, the Infrascope offers greater sensitivity and a wider range of frequencies heard by the human ear, <20Hz than a traditional stethoscope can detect. Through automated analysis of the full spectrum of heart sounds, it has the potential to improve diagnostic accuracy while reducing the need for referrals, allowing primary care physicians to practice better medicine at the bedside.

Infrasounds↗

Portable zero-delay assembly

Instrument is calibrated using back-to-back method. In comparison standard, S-X isolators are opposite from device being tested to permit signal flow in reverse direction. After calibration portable zero-delay assembly (PZDA) is used to set time delays of deep-space network ground-station ranging systems. Approach is also used to calibrate microwave links in other communications systems.

Franco, M. M.↗

Real-Time Deposition Monitor for Ultrathin Conductive Films

A device has been developed that can be used for the real-time monitoring of ultrathin (2 or more) conductive films. The device responds in less than two microseconds, and can be used to monitor film depositions up to about 60 thick. Actual thickness monitoring capability will vary based on properties of the film being deposited. This is a single-use device, which, due to the very low device cost, can be disposable. Conventional quartz/crystal microbalance devices have proven inadequate to monitor the thickness of Pd films during deposition of ultrathin films for hydrogen sensor devices. When the deposited film is less than 100 , the QCM measurements are inadequate to allow monitoring of the ultrathin films being developed. Thus, an improved, high-sensitivity, real-time deposition monitor was needed to continue Pd film deposition development. The new deposition monitor utilizes a surface acoustic wave (SAW) device in a differential delay-line configuration to produce both a reference response and a response for the portion of the device on which the film is being deposited. Both responses are monitored simultaneously during deposition. The reference response remains unchanged, while the attenuation of the sensing path (where the film is being deposited) varies as the film thickness increases. This device utilizes the fact that on high-coupling piezoelectric substrates, the attenuation of an SAW undergoes a transition from low to very high, and back to low as the conductivity of a film on the device surface goes from nonconductive to highly conductive. Thus, the sensing path response starts with a low insertion loss, and as a conductive film is deposited, the film conductivity increases, causing the device insertion loss to increase dramatically (by up to 80 dB or more), and then with continued film thickness increases (and the corresponding conductivity increases), the device insertion loss goes back down to the low level at which it started. This provides a continuous, real-time monitoring of film deposition. For use with different films, the device would need to be calibrated to provide an understanding of how film thickness is related to film conductivity, as the device is responding primarily to conductivity effects (and not to mass loading effects) in this ultrathin film regime.

Hines, Jacqueline↗

Applications of charge-coupled device transversal filters to communication

The paper discusses the computational power of state-of-the-art charged-coupled device (CCD) transversal filters in communications applications. Some of the performance limitations of CCD transversal filters are discussed, with attention given to time delay and bandwidth, imperfect charge transfer efficiency, weighting coefficient error, noise, and linearity. The application of CCD transversal filters to matched filtering, spectral filtering, and Fourier analysis is examined. Techniques for making programmable transversal filters are briefly outlined.

Buss, D. D.↗

Fiber loop quantum buffer for photonic qubits

Abstract We report a fiber loop quantum buffer based on a low-loss 2 × 2 switch and a unit delay made of a fiber delay line. We characterize the device by using a two-photon polarization entangled state in which one photon of the entangled photon pair is stored and retrieved at a repetition rate up to 78 kHz. The device, which enables integer multiples of a unit delay, can store the qubit state in a unit of fiber delay line up to 5.4 km and the number of loop round-trips up to 3. Furthermore, we configure the device with other active elements to realize integer multiplier and divider of a unit delay of a qubit. The quantum state tomography is performed on the retrieved photon and its entangled photon. We obtain a state fidelity > 94 % with a maximum storage time of 52 s with an insertion loss of 5.56 dB. To further characterize the storing and retrieving processes of the device, we perform entanglement-assisted quantum process tomography on the buffered qubit state. The process fidelity of the device is > 0.98. Our result implies that the device preserves the superposition and entanglement of a qubit state from a two-photon polarization-entangled state. This is a significant step towards facilitating applications in optical asynchronous transfer mode based quantum networks.

Fook Lee, Kim (ORCID:0000000290901640)↗

An 860 MHz Wireless Surface Acoustic Wave Sensor with a Metal-Organic Framework Sensing Layer for CO2 and CH4

Wireless and passive surface acoustic wave (SAW) devices with nanoporous metal-organic framework (MOF) sensing layers are attractive gas sensors for applications in many fields such as energy industries and air pollution control. Here, we report on enhancing the sensitivity and detection limit of zeolitic imidazolate framework-8 (ZIF-8) MOF-coated SAW reflective delay line mass sensors by increasing the operating frequency for sensitive detection of carbon dioxide (CO2) and methane (CH4) at ambient conditions. In particular, we show at least four times higher sensitivity of an 860 MHz (4-μm periodicity) SAW reflective delay line coated with a 240 nm thick ZIF-8 compared to the sensitivity of a 430 MHz (8-μm periodicity) otherwise identical sensor device to the targeted gases. The detection limits of the higher frequency wireless devices for CO2 and CH4 were estimated to be 0.91 vol-% and 7.01 vol-%, respectively. The enhanced sensitivity for higher frequency devices is explained in terms of the frequency dependent acoustic wave energy confinement.

Devkota, Jagannath↗

Octave-spanning terahertz quarter-wave plates based on over-coupled Fabry–Pérot resonances in reflective metal–dielectric–metal metasurfaces

Compact devices for broadband polarization control in the terahertz (THz) regime remain challenging to realize due to the intrinsic phase dispersion associated with birefringent materials and resonant structures. Here, we demonstrate achromatic THz quarter-wave plates with near-unity efficiency and operating under a wide range of incidence angles, based on over-coupled metal–dielectric–metal reflective metasurfaces. The devices operate as single-port anisotropic Fabry–Pérot cavities, in which the phase dispersion of the over-coupled resonances is engineered to maintain an approximately constant relative phase delay between orthogonal field components over a broad frequency range. Four complementary metasurface designs operating at an incidence angle of 45° collectively cover the 0.25–3 THz frequency range accessible to a typical THz time-domain spectroscopy system. Each device exhibits an approximately octave-wide operational bandwidth, with axial ratios below 3 dB and polarization-conversion efficiencies exceeding 80% across most of the operating band. Systematic structural optimization suppresses coupling to diffraction and guided-wave modes, thereby further extending the usable bandwidth while preserving the required phase relationship between orthogonal polarizations. The demonstrated metasurfaces are compatible with wafer-scale fabrication processes, and experimental results show excellent agreement with simulations. These findings establish over-coupled reflective metasurfaces as a robust, scalable, and versatile platform for broadband THz polarization control.

36 MATERIALS SCIENCE↗

Preparation for an Earth Independent Medical Operations Demonstration using the Tempus ALS™ Medical Device

NASA’s exploration-class missions have severe resource constraints, long return trip durations, significant communication delays and limited resupply opportunities. Validation on the International Space Station (ISS) of medical devices that fit within Earth-Independent Medical Operations (EIMO) systems is a necessary preparation step. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. The Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element and the Exploration Medical Integrated Product Team (XM-IPT) are planning an ISS technology demonstration to determine the feasibility of including a multifunctional medical device into an EIMO medical system. Demonstration Preparations: The Tempus ALS (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf medical device, with United States Food and Drug Administration clearance and is Conformité Européene marked in Europe. Several thousand units have been sold and are successfully operating in pre-hospital and in remote settings, such as by European Space Agency (ESA) flight surgeons and some of NASA’s commercial partners during post-flight medical operations. The Tempus ALS provides vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature. The device has ultrasound imaging and video laryngoscopy capabilities and has automatic or manual defibrillation modes for treating cardiac arrhythmias. It includes procedural guidance capabilities to assist in the collection of the vital sign measurements and it has various data transmission and report generation features. NASA’s HRP ExMC and XM-IPT are partnering with the ESA to demonstrate the Tempus ALS on ISS, with ESA manifesting the Tempus ALS and its accessories. ESA will compare performance of periodic health status exams and medical contingency drills performed nominally and with the Tempus ALS. NASA’s EIMO demonstration will include the use of Tempus ALS to diagnose a complaint of abdominal pain under increasingly independent circumstances. The caregiver must assess the present illness, collect vital sign measurements, and perform an abdominal ultrasound, under one of three communication situations, including real-time, with a several second delay and with a delay on the order of minutes. Expected Outcomes: Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis instead of separate devices with singular functionalities. Information will also be collected about performance differences as communication delays increase and available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities which takes the EIMO construct into consideration.

Beth Lewandowski↗

Picosecond spin-orbit torque–induced coherent magnetization switching in a ferromagnet

Electrically controllable nonvolatile magnetic memories show great potential for the replacement of conventional semiconductor-based memory technologies. Here, we experimentally demonstrate ultrafast spin-orbit torque (SOT)-induced coherent magnetization switching dynamics in a ferromagnet. We use an ultrafast photoconducting switch and a coplanar strip line to generate and guide a ~9-picosecond electrical pulse into a heavy metal/ferromagnet multilayer to induce ultrafast SOT. We then use magneto-optical probing to investigate the magnetization dynamics with sub-picosecond resolution. Ultrafast heating by the approximately 9 picosecond current pulse induces a thermal anisotropy torque which, in combination with the damping-like torque, coherently rotates the magnetization to obtain zero-crossing of magnetization in ~70 picoseconds. A macro-magnetic simulation coupled with an ultrafast heating model agrees well with the experiment and suggests coherent magnetization switching without any incubation delay on an unprecedented time scale. Our work proposes a unique magnetization switching mechanism toward markedly increasing the writing speed of SOT magnetic random-access memory devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of the Microwave Anisotropy Probe AST-201 Star Trackers

The Microwave Anisotropy Probe (MAP) was launched to create a full-sky map of the cosmic microwave background. MAP incorporates two modified Lockheed Martin AST-201 (Autonomous Star Tracker) star trackers. The AST-201 employs an eight element radiation hardened lens assembly which is used to focus an image on a charge coupled device (CCD). The CCD image is then processed by a star identification algorithm which outputs a three-axis attitude. A CCD-shift algorithm called Time Delayed Integration (TDI) was also included in each star tracker. In order to provide some radiation effect filtering during MAP's three to five phasing loop passes through the Van Allen radiation belts, a simple pixel filtering scheme was implemented, rather than using a more complex, but more robust windowing algorithm. The trackers also include a fiber optic data interface. This paper details the ground testing that was accomplished on the MAP trackers.

Ward, David K.↗

Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs

Time-consuming, expensive and low sensitivity diagnostic methods used for monitoring bacterial infections lead to unnecessary or delays in prescription of the right antibiotic treatment. Determining an optimal clinical treatment requires rapid detection and identification of pathogenic bacteria and their sensitivity to specific antimicrobials. However, diagnostic devices that meet all of these criteria have proven elusive thus far. Graphene field effect transistors (G-FET) are a promising solution, since they are highly sensitive to chemical/biological modification, can have fast detection times and can be placed on different substrates. Here, by integrating specific peptide probes over G-FETs, we present a proof-of-concept study for species and strain specific label-free detection of clinical strains of pathogenic bacteria with high specificity and sensitivity. We found that pyrene-conjugated peptides immobilized on G-FETs were capable of detecting pathogenic Staphylococcus aureus at the single-cell level and discriminate against other gram-positive and gram-negative bacterial pathogens. A similar device was able to discriminate between antibiotic resistant and sensitive strains of Acinetobacter baumannii , suggesting that these devices can also be used for detecting antibiotic resistive pathogens. Furthermore, a new means of enhancing attachment, electric-field assisted binding, reduced the detection limit to 104 cells/ml and the detection time to below 5 minutes. Here, the combination of single step attachment, inexpensive production, rapid, selective and sensitive detection suggest G-FETs plus pyrene-conjugated peptides are a new platform for solving major challenges faced in point of care diagnostics to fight infectious diseases and antimicrobial resistance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Controlling telerobots with video data and compensating for time-delayed video using Omniview

Remote viewing is critical for teleoperations, but the inherent limitations of standard video reduce the operator's effectiveness. These limitations have been compensated for in many ways, from using the operator's adaptability, to augmenting his capability with feedback from a variety of sensors and simulations. Omniview can overcome some of these limitations and improve the operator's efficiency without adding additional sensors or computational burden. It can minimize the potential collisions with facility equipment, provide peripheral vision, and display multiple images simultaneously from a single input device. The Omniview technology provides electronic pan, tilt, magnify, and rotational orientation within a hemispherical field-of-view without any moving parts. Image sizes, viewing directions, scale, offset, etc., may be adjusted to fit operator needs. This paper discusses the derivation of the image transformation, the design of the electronics, and two applications to telepresence that are under development. These are Video Emulated Tweening (VET), and Manipulator Guidance and Positioning (ManGAP). The VET effort uses Omniview to compensate for time-delayed video in teleoperation of remote vehicles. In ManGAP two Omniview systems are used to provide two sets of orientation vectors to points in the field-of-view (FOV). These vectors then provide absolute position information to both control the position of the telerobot, and to avoid collisions with the work sight equipment.

Kuban, Dan↗