Search NASA⌕ Search

SEARCH · Search NASA

Results for “tin sensitization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

80 records · Page 5

Technology progress and clean vehicle policies on fleet turnover and equity: insights from household vehicle fleet micro-simulations with $\text{ATLAS}$

This paper documents the design and application of ATLAS (Automobile and Technology Lifecycle-Based ASsignment), a comprehensive household vehicle transaction and technology adoption micro-simulator in the San Francisco Bay Area. ATLAS evolves the fleet mix of individual households by simulating the vehicle transaction and choice decisions in response to co-evolving demographics, land use, and vehicle technology simulations. While most existing literature has focused on the aggregate clean vehicle uptake, this paper differentiates distributional effects and decomposes the underlying mechanisms across heterogeneous sub-populations of households. Using scenarios and sensitivity simulations that vary vehicle technology and policy assumptions, we find that Zero Emission Vehicles (ZEVs) penetrate into higher income groups at a faster rate than into lower income groups, which is intuitive and aligns with expectations. Interestingly, the relative income disparity in ZEV ownership shrinks over time across all scenarios, with a ZEV mandate coupled with declining battery cost leading to the greatest reduction in disparity of ZEV ownership by 2050. Federal, state, and local financial incentives influence the redistribution of ZEV uptake across income groups and contribute to narrowing income disparity. Vehicle transaction frequency and new versus used market dynamics are found to be important factors contributing to the income disparity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum Phase Engineering of Two-Dimensional Post-Transition Metals by Substrates: Toward a Room-Temperature Quantum Anomalous Hall Insulator

In this work, we propose a new strategy to engineer topological and magnetic properties of two-dimensional (2D) hexagonal lattices consisting of post-transition metals. Our first-principles calculations demonstrate that substrates serve as templates to form 2D lattices with high thermodynamic stability, where their topological properties as well as magnetic properties sensitively change as a function of lattice constants, i.e., the system undergoes a first-order phase transition from nonmagnetic to ferromagnetic state above a critical lattice constant. Consequently, substrates can be used to explore versatile magnetic, electronic, and quantum topological properties. We establish phase diagrams of versatile quantum phases in terms of exchange coupling and spin–orbit coupling effectively tuned by the lattice constants. We further reveal the first room-temperature quantum anomalous Hall (QAH) effect, i.e., Sn on 2√3 × 2√3 graphane is a QAH insulator with a large spin–orbit coupling gap of ~0.2 eV and a Curie temperature of ~380 K by using the 2D anisotropic Heisenberg model.

36 MATERIALS SCIENCE↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Designs and Materials for Better Coronagraph Occulting Masks

New designs, and materials appropriate for such designs, are under investigation in an effort to develop coronagraph occulting masks having broad-band spectral characteristics superior to those currently employed. These designs and materials are applicable to all coronagraphs, both ground-based and spaceborne. This effort also offers potential benefits for the development of other optical masks and filters that are required (1) for precisely tailored spatial transmission profiles, (2) to be characterized by optical-density neutrality and phase neutrality (that is, to be characterized by constant optical density and constant phase over broad wavelength ranges), and/or (3) not to exhibit optical- density-dependent phase shifts. The need for this effort arises for the following reasons: Coronagraph occulting masks are required to impose, on beams of light transmitted through them, extremely precise control of amplitude and phase according to carefully designed transmission profiles. In the original application that gave rise to this effort, the concern has been to develop broad-band occulting masks for NASA s Terrestrial Planet Finder coronagraph. Until now, experimental samples of these masks have been made from high-energy-beam-sensitive (HEBS) glass, which becomes locally dark where irradiated with a high-energy electron beam, the amount of darkening depending on the electron-beam energy and dose. Precise mask profiles have been written on HEBS glass blanks by use of electron beams, and the masks have performed satisfactorily in monochromatic light. However, the optical-density and phase profiles of the HEBS masks vary significantly with wavelength; consequently, the HEBS masks perform unsatisfactorily in broad-band light. The key properties of materials to be used in coronagraph occulting masks are their extinction coefficients, their indices of refraction, and the variations of these parameters with wavelength. The effort thus far has included theoretical predictions of performances of masks that would be made from alternative materials chosen because the wavelength dependences of their extinction coefficients and their indices of refraction are such that that the optical-density and phase profiles of masks made from these materials can be expected to vary much less with wavelength than do those of masks made from HEBS glass. The alternative materials considered thus far include some elemental metals such as Pt and Ni, metal alloys such as Inconel, metal nitrides such as TiN, and dielectrics such as SiO2. A mask as now envisioned would include thin metal and dielectric films having stepped or smoothly varying thicknesses (see figure). The thicknesses would be chosen, taking account of the indices of refraction and extinction coefficients, to obtain an acceptably close approximation of the desired spatial transmittance profile with a flat phase profile

Balasubramanian, Kunjithapatham↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Chloride Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

Uranium electrorefining operations at Y-12 require validation for chlorine absorption and reflection. Plutonium chloride solution operations at Los Alamos National Laboratory require chlorine absorption validation. The growing need for chlorine validation is evident to the wider criticality safety community, with multiple attendees at the recent TEX 2.0 meeting at Lawrence Livermore National Laboratory (May 2023) requesting validation for chlorine (Idaho National Laboratory (INL), Institute de radioprotection et de surete nucleaire (IRSN), Savannah River Nuclear Site (SRNS), LANL, and Y-12). Los Alamos National Laboratory has recently performed, and benchmarked, an experiment titled Chlorine Worth Study (CWS) for the internal operations at the lab, but due to the difficulties in precisely characterizing the material compositions of the chlorine absorbers it is advantageous to perform a complimentary study with a different chlorine-based absorber material. Furthermore, having a uranium-based vs plutonium-based experiment provides a separate and important validation basis for criticality safety and nuclear data evaluation. The original final design report for the study of chlorine absorption using the TEX-HEU experimental base was presented in 2022, but used the same chlorine-bearing materials that were found to be difficult to characterize in the LANL benchmark. A complete redesign of the experiment has been performed looking at alternative absorber materials in various forms to produce an experiment that is fully characterizable. This report presents five novel chlorine experiments using the TEX-HEU test bed which provides direct comparison to the Y-12 and INL/Terrapower application needs, utilizing sodium chloride (NaCl) absorber plates. The absorber plates will consist of granulated NaCl (≥99.5% pure), which will be fully encapsulated in aluminum tins, providing a simple but effective chlorine-based absorber material that can be completely characterized. Of the five configurations presented in this report, it is expected that two or three configurations will be down selected for the actual experiment, with the other configurations being alternates. Three of the configurations are in the standard configuration, where the absorber is placed directly on the HEU fuel plates, and two in the sandwich configuration, where the absorber is surrounded by polyethylene moderators to force additional neutron thermalization prior to reaching the absorber. There are two thicknesses of NaCl absorber plates: 3/16” and 1/4” active thicknesses (i.e. not including the encapsulation). Both variations of the absorbers have an active absorber radius of 6” and a total radius of 7.5” to match the diameter of the HEU plates, with the outer 1.5” being aluminum encapsulation. The high-density polyethylene (HDPE) moderators are of the thicknesses: 27/16”, 7/4”, 1/8”, 11/16”, and 3/4”. The final configurations have six (one sandwich and one standard configuration), eight (one sandwich and one standard configuration), and 18 total fuel layers (standard configuration). The standard and sandwich configurations were designed such that the differences in moderator thicknesses are 1” HDPE, which were already procured for the original CED-2. The proposed configurations were precisely tuned to closely match the sensitivity profiles and neutron spectra of the Y-12 upset cases and were also compared to the INL/Terrapower upset cases. The assessment of experimental uncertainties of the non-absorber components was predicted to be 0.00114 Δk eff . The assessment of uncertainties resulting from the absorbers was predicted to be 0.00029 Δk eff . This results in a total uncertainty of 0.00118 Δk eff . Many of the largest uncertainties, namely the moderator densities, may be reduced with precision dimensional inspection of the components. The 1” HDPE moderators as well as the HDPE reflectors from the original CED-2 were incorporated in the final designs presented here. Additional HDPE moderator plates must be fabricated to complete the configurations. NaCl absorber plates will by fabricated at LLNL. The total additional cost is expected to be $\$$54,250 for the remaining components. Precise inspection, including dimensional, mass, density, and impurity, is recommended for all components. LLNL estimates that these costs are around $\$$12,000. It is expected, based on previous TEX-HEU experiments, that three weeks of experimental facility time is needed to complete the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microstructure characterization and elastic-plastic self-consistent simulation studies of anisotropic deformation of β -tin

Uniaxial compression tests of 99.9% pure polycrystalline $β$-tin (Sn) were conducted at various strain rates (10 -3 /s, 10 -1 /s and 1/s) and temperatures (294 K and 193 K) to understand the effects of these variables on the stress–strain response, microstructure evolution, and stress relaxation behavior. Multiple Sn specimens were subjected to complex compressive loading/unloading/reloading paths at different strain rates. Specimens initially compressed at higher strain rates showed strain rate-dependent texture evolution and more pronounced relaxation upon reloading, as compared to those pre-strained at lower rates at room temperature (RT). Compression tests conducted at low temperature (193 K) revealed increased strength, similar to the enhanced strength observed when the strain rate was increased at RT. Neutron diffraction was employed to characterize the initial and final bulk textures of the RT specimens. Electron backscatter diffraction was utilized to examine the crystallographic grain orientation and morphology, thereby identifying the signatures of dislocation-mediated deformation, grain refinement, recrystallization, and twinning behaviors. Elastic-plastic self-consistent simulations were performed to investigate the deformation modes responsible for the strain rate-dependent macroscopic stress–strain response and texture evolution. Effects of crystallographic orientation on stress relaxation behavior was also examined. In conclusion, the model predictions are in reasonable agreement with experimental observations.

36 MATERIALS SCIENCE↗

Genomic and phenotypic predictors of human ex vivo sensitivity to simulated deep space radiation

High-linear energy transfer (LET) ionizing radiation is a major health hazard for astronauts who will be exposed to galactic cosmic rays during upcoming lunar and Mars missions. Predicting and mitigating this risk requires understanding the factors underlying individual radiation sensitivity. We started to address this challenge by identifying the genomic and phenotypic associations with sensitivity to low and high-LET ionizing radiation ex vivo in over 750 healthy human donors. We exposed primary human blood mononuclear cells to simulated galactic cosmic ray components: 350MeV/n (28)Si, 350MeV/n (40)Ar and 600MeV/n (56)Fe particles, at 1.1 and 3 particles/100µm^(2) fluences, as well as 0.1 Gy and 1 Gy doses of gamma rays, and analyzed the outcomes at 4 and 24 hours post-irradiation. We quantified DNA damage and repair responses based on 53BP1^(+) radiation-induced foci formation, together with oxidative stress and changes in secreted factors including immune cytokines and exosomes. We also analyzed phenotypic associations with spontaneous DNA repair foci at baseline prior to irradiation. We identified an increase in spontaneous DNA repair associated with age and latent viral infection, and observed that human spontaneous DNA repair foci at baseline can serve as a negative predictor of DNA repair and immunoregulatory cytokine production after irradiation. Furthermore, we observed a wide variability of subject- and LET-dependent radiation responses, with radiation-induced DNA repair foci increasing by dose and LET, and high-LET particle radiation resulting in more residual DNA damage compared to low-LET particles and gamma rays. We have developed multiple metrics to quantify human radiosensitivity across the spectrum of conditions. Here we present their dependence on radiation quality and phenotypic variables, including an age-dependent decrease in DNA repair after irradiation, and genomic associations with radiosensitivity based on low-coverage whole genome sequencing. We anticipate that our work will pave the way for understanding the spectrum of human radiosensitivity and identifying targets for countermeasure development to reduce DNA and cellular damage and radiation carcinogenesis during deep space exploration.

GWAS↗

Application of Nuclear Technology to Art Identification Problems: First Annual Report

Throughout the centuries, as man has become increasingly affluent, his interest in antiquities and objects of art, and the price he has been willing to pay for them, has increased. Inevitably, one result has been to attract the unscrupulous to the production and sale of counterfeit paintings, sculptures, and other works of art. The skill of forgers varies but often is highly sophisticated. However, dealers, museum curators, and other experts have also become more skillful in the detection of forgeries. Scientific tools of increasing sensitivity and sophistication have gradually been applied to the examination of the materials of art and archaeology. Such tools frequently support and render more reliable the judgment of the experts. The quality of forgeries may improve further as their makers become acquainted with the new methods of detection and in turn learn to circumvent or confound the methods. Therefore, the development of still more advanced methods of examination has great utility in the art world. This is particularly true if the ultimate effect is to make circumvention of the methods of examination so costly that the economic incentives for producing forgeries may be substantially reduced, if not eliminated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗