Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design of smart 3D-digital X-ray microtomographic scanners for non-destructive testing of materials and components of electronic devices with a multilayered structure

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. Chapter 4 covers general procedures of defect search, which is based on vector analysis principles. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray microtomographic scanners

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of core-annular flow in an industrial scale circulating fluidized bed riser with electrical capacitance volume tomography (ECVT)

There is a paucity of riser data for industrial scale units, particularly with regard to the solids fraction. This is especially true for detailed spatially distributed values. To alleviate this problem, NETL installed a 0.445 m tall electrical capacitance volume tomography (ECVT) sensor 9.66 m from the gas distributor of its industrial size (15.45 m high and 0.3 m diameter) circulating fluidized bed (CFB) cold model. A series of tests were conducted to investigate the gas-solid flow behavior using high density polyethylene (PPE) solids. Static electricity was successfully minimized using Larostat and humidification. Time averaged radial solid fractions profiles are presented and discussed. The time and spatially averaged solid fractions measured by the ECVT agree well with estimates from the pressure drop. The annular thickness was measured and found to increase with increases in the solids flow rate and decrease with increases in the gas velocity. Comparisons of the annular thickness and solids fraction as determined from the ECVT unit were compared to existing correlations. In conclusion, the average error ranged from 13% to 275% which is not surprising since the literature correlations were developed from data on much smaller units and for significantly different particles.

42 ENGINEERING↗

Image features for misalignment correction in medical flat-detector CT

Purpose: Misalignment artifacts are a serious problem in medical flat-detector computed tomography. Generally, the geometrical parameters, which are essential for reconstruction, are provided by preceding calibration routines. These procedures are time consuming and the later use of stored parameters is sensitive toward external impacts or patient movement. The method of choice in a clinical environment would be a markerless online-calibration procedure that allows flexible scan trajectories and simultaneously corrects misalignment and motion artifacts during the reconstruction process. Therefore, different image features were evaluated according to their capability of quantifying misalignment. Methods: Projections of the FORBILD head and thorax phantoms were simulated. Additionally, acquisitions of a head phantom and patient data were used for evaluation. For the reconstruction different sources and magnitudes of misalignment were introduced in the geometry description. The resulting volumes were analyzed by entropy (based on the gray-level histogram), total variation, Gabor filter texture features, Haralick co-occurrence features, and Tamura texture features. The feature results were compared to the back-projection mismatch of the disturbed geometry. Results: The evaluations demonstrate the ability of several well-established image features to classify misalignment. The authors elaborated the particular suitability of the gray-level histogram-based entropy on identifying misalignment artifacts, after applying an appropriate window level (bone window). Conclusions: Some of the proposed feature extraction algorithms show a strong correlation with the misalignment level. Especially, entropy-based methods showed very good correspondence, with the best of these being the type that uses the gray-level histogram for calculation. This makes it a suitable image feature for online-calibration.

60 APPLIED LIFE SCIENCES↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Low background high efficiency radiocesium detection system based on positron emission tomography technology

After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the distribution of paste-void spacing of hardened cement paste using X-ray computed tomography

The distribution of paste-void spacing in cement-based materials is an important feature related to the freeze-thaw durability of these materials, but its reliable estimation remains an unresolved problem. Herein, we evaluate the capability of X-ray computed tomography (CT) for reliable quantification of the distribution of paste-void spacing. Using X-ray CT images of three mortar specimens having different air-entrainment characteristics, we calculate the distributions of paste-void spacing of the specimens by applying previously suggested methods for deriving the exact spacing of air-void systems. This methodology is assessed by comparing the 95th percentile of the cumulative distribution function of the paste-void spacing with spacing factors computed by applying the linear-traverse method to 3D air-void system and reconstructing equivalent air-void distribution in 3D. Results show that the distributions of equivalent void diameter and paste-void spacing follow lognormal and normal distributions, respectively, and the ratios between the 95th percentile paste-void spacing value and the spacing factors reside within the ranges reported by previous numerical studies. This experimental finding indicates that the distribution of paste-void spacing quantified using X-ray CT has the potential to be the basis for a statistical assessment of the freeze-thaw durability of cement-based materials. - Highlights: Black-Right-Pointing-Pointer The paste-void spacing in 3D can be quantified by X-ray CT. Black-Right-Pointing-Pointer The distribution of the paste-void spacing follows normal distribution. Black-Right-Pointing-Pointer The spacing factor and 95th percentile of CDF of paste-void spacing are correlated.

36 MATERIALS SCIENCE↗

TomoPyUI : a user-friendly tool for rapid tomography alignment and reconstruction

The management and processing of synchrotron and neutron computed tomography data can be a complex, labor-intensive and unstructured process. Users devote substantial time to both manually processing their data ( i.e. organizing data/metadata, applying image filters etc. ) and waiting for the computation of iterative alignment and reconstruction algorithms to finish. In this work, we present a solution to these problems: TomoPyUI , a user interface for the well known tomography data processing package TomoPy . This highly visual Python software package guides the user through the tomography processing pipeline from data import, preprocessing, alignment and finally to 3D volume reconstruction. The TomoPyUI systematic intermediate data and metadata storage system improves organization, and the inspection and manipulation tools (built within the application) help to avoid interrupted workflows. Notably, TomoPyUI operates entirely within a Jupyter environment. Herein, we provide a summary of these key features of TomoPyUI , along with an overview of the tomography processing pipeline, a discussion of the landscape of existing tomography processing software and the purpose of TomoPyUI , and a demonstration of its capabilities for real tomography data collected at SSRL beamline 6-2c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inverse transport calculations in optical imaging with subspace optimization algorithms

Inverse boundary value problems for the radiative transport equation play an important role in optics-based medical imaging techniques such as diffuse optical tomography (DOT) and fluorescence optical tomography (FOT). Despite the rapid progress in the mathematical theory and numerical computation of these inverse problems in recent years, developing robust and efficient reconstruction algorithms remains a challenging task and an active research topic. We propose here a robust reconstruction method that is based on subspace minimization techniques. The method splits the unknown transport solution (or a functional of it) into low-frequency and high-frequency components, and uses singular value decomposition to analytically recover part of low-frequency information. Minimization is then applied to recover part of the high-frequency components of the unknowns. We present some numerical simulations with synthetic data to demonstrate the performance of the proposed algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bilevel optimization, deep learning and fractional Laplacian regularization with applications in tomography

Here we consider a generalized bilevel optimization framework for solving inverse problems. We introduce fractional Laplacian as a regularizer to improve the reconstruction quality, and compare it with the total variation regularization. We emphasize that the key advantage of using fractional Laplacian as a regularizer is that it leads to a linear operator, as opposed to the total variation regularization which results in a nonlinear degenerate operator. Inspired by residual neural networks, to learn the optimal strength of regularization and the exponent of fractional Laplacian, we develop a dedicated bilevel optimization neural network with a variable depth for a general regularized inverse problem. We illustrate how to incorporate various regularizer choices into our proposed network. As an example, we consider tomographic reconstruction as a model problem and show an improvement in reconstruction quality, especially for limited data, via fractional Laplacian regularization. We successfully learn the regularization strength and the fractional exponent via our proposed bilevel optimization neural network. We observe that the fractional Laplacian regularization outperforms total variation regularization. This is specially encouraging, and important, in the case of limited and noisy data.

97 MATHEMATICS AND COMPUTING↗

Toward Water Volume Fraction Calculation in Multiphase Flows Using Electrical Capacitance Tomography Sensors

Real-time monitoring of water volume fraction in multiphase flows is an important problem for a number of industrial applications. The water phase in the multiphase flows may correspond to either the dispersed phase or the continuous phase. In the past, several lowcost and nonintrusive techniques based on the electrical capacitance tomography (ECT) has been developed to image and monitor in real-time multiphase flows containing water. Furthermore, such monitoring becomes increasingly challenging for high salinity levels, and no reliable ECTbased method is presently available which could work for obtaining water volume fraction in multiphase flows for all water salinity levels. In this paper, we propose a new approach based on the Hanai’s formula for complex dielectric constant and taking advantage of the Maxwell- Wagner-Sillars effect to obtain, to a good approximation, water volume fractions in multiphase flows containing water as either dispersed or continuous phase.

02 PETROLEUM↗

Positron Emission Tomography in Water Resources and Subsurface Energy Resources Engineering Research

Recent studies have demonstrated that positron emission tomography (PET) is a valuable tool for in-situ characterization of fluid transport in porous and fractured geologic media at the laboratory scale. While PET imaging is routinely used for clinical cancer diagnosis and preclinical medical research—and therefore imaging facilities are available at most research institutes—widespread adoption for applications in water resources and subsurface energy resources engineering have been limited by real and perceived challenges of working with this technique. In this study we discuss and address these challenges, and provide detailed analysis highlighting how positron emission tomography can complement and improve laboratory characterization of different subsurface fluid transport problems. The physics of PET are reviewed to provide a fundamental understanding of the sources of noise, resolution limits, and safety considerations. We then layout the methodology required to perform laboratory experiments imaged with PET, including a new protocol for radioactivity dosing optimization for imaging in geologic materials. Signal-to-noise and sensitivity analysis comparisons between PET and clinical X-ray computed tomography are performed to highlight how PET data can complement more traditional characterization methods, particularly for solute transport problems. Lastly, prior work is critically reviewed and discussed to provide a better understanding of the strengths and weakness of PET and how to best utilize PET-derived data for future studies.

02 PETROLEUM↗

Survey of Deep Learning and Physics-Based Approaches in Computational Wave Imaging

Computational wave imaging (CWI) extracts hidden structure and physical properties of a volume of material by analyzing wave signals that traverse that volume. Applications include seismic exploration of the Earth’s subsurface, acoustic imaging and nondestructive testing (NDT) in material science, and ultrasound computed tomography (USCT) in medicine. Current approaches for solving CWI problems can be divided into two categories: those rooted in traditional physics and those based on deep learning. Physics-based methods stand out for their ability to provide high-resolution and quantitatively accurate estimates of acoustic properties within the medium. However, they can be computationally intensive and are susceptible to ill-posedness and nonconvexity typical of CWI problems. Machine learning (ML)-based computational methods have recently emerged, offering a different perspective to address these challenges. Diverse scientific communities have independently pursued the integration of deep learning in CWI. This review discusses how contemporary scientific ML techniques, and deep neural networks in particular, have been developed to enhance and integrate with traditional physics-based methods for solving CWI problems. We present a structured framework that consolidates existing research spanning multiple domains, including computational imaging, wave physics, and data science. This study concludes with important lessons learned from existing ML-based methods and identifies technical hurdles and emerging trends through a systematic analysis of the extensive literature on this topic.

42 ENGINEERING↗

HYPPO: A Surrogate-Based Multi-Level Parallelism Tool for Hyperparameter Optimization

We present a new software, HYPPO, that enables the automatic tuning of hyperparameters of various deep learning (DL) models. Unlike other hyperparameter optimization (HPO) methods, HYPPO uses adaptive surrogate models and directly accounts for uncertainty in model predictions to find accurate and reliable models that make robust predictions. Using asynchronous nested parallelism, we are able to significantly alleviate the computational burden of training complex architectures and quantifying the uncertainty. HYPPO is implemented in Python and can be used with both TensorFlow and PyTorch libraries. We demonstrate various software features on time-series prediction and image classification problems as well as a scientific application in computed tomography image reconstruction. Finally, we show that (1) we can reduce by an order of magnitude the number of evaluations necessary to find the most optimal region in the hyperparameter space and (2) we can reduce by two orders of magnitude the throughput for such HPO process to complete.

adaptation models↗

Forward problem solution as the operator of filtered and back projection matrix to reconstruct the various method of data collection and the object element model in electrical impedance tomography

Back projection reconstruction has been implemented to get the dynamical image in electrical impedance tomography. However the implementation is still limited in method of adjacent data collection and circular object element model. The study aims to develop the methods of back projection as reconstruction method that has the high speed, accuracy, and flexibility, which can be used for various methods of data collection and model of the object element. The proposed method uses the forward problem solution as the operator of filtered and back projection matrix. This is done through a simulation study on several methods of data collection and various models of the object element. The results indicate that the developed method is capable of producing images, fastly and accurately for reconstruction of the various methods of data collection and models of the object element.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Level Set Evaporation Model for Heterogeneous Atom Probe Tip

With the development of local electrode atom probe tomography (LEAP), the materials systems feasible for atomic structure determination has expanded from predominantly metals to include heterogeneous materials with complex structure and compositions. This makes the 3D atomic structure determination possible for most energy materials in battery, fuel cell, semiconductor, and nuclear applications. Atom probe tomography (APT) has been utilized to study multiphase materials with segregation and interface problems. The unique and quantitative information retrieved from APT can provide a foundation for the study of kinetic pathways, nanoscale composition mapping, multilayer interfacial segregation, dislocations and grain boundaries. However, a new challenge surfaces when the materials systems expand into heterogeneous materials: the traditional structure reconstruction introduces false magnification and large artifacts due to the underlying assumption of uniform and isotropic evaporation.

Atom probe, heterogeneous structure, evporation mo↗

Determination of solute site occupancies within γ' precipitates in nickel-base superalloys via orientation-specific atom probe tomography

In this study, the analytical limitations in atom probe tomography such as resolving a desired set of atomic planes, for solving complex materials science problems, have been overcome by employing a well-developed unique and reproducible crystallographic technique, involving synergetic coupling of orientation microscopy with atom probe tomography. The crystallographic information in atom probe reconstructions has been utilized to determine the solute site occupancies in Ni-Al-Cr based superalloys accurately. The structural information in atom probe reveals that both Al and Cr occupy the same sub-lattice within the L1 2 -ordered g precipitates to form Ni 3 (Al,Cr) precipitates in a Ni-14Al-7Cr(at.%) alloy. Interestingly, the addition of Co, which is a solid solution strengthener, to a Ni-14Al-7Cr alloy results in the partial reversal of Al site occupancy within g precipitates to form (Ni,Al) 3 (Al,Cr,Co) precipitates. This unique evidence of reversal of Al site occupancy, resulting from the introduction of other solutes within the ordered structures, gives insights into the relative energetics of different sub-lattice sites when occupied by different solutes.

36 MATERIALS SCIENCE↗

Frequency-Domain Streak Camera and Tomography for Ultrafast Imaging of Evolving and Channeled Plasma Accelerator Structures

We demonstrate a prototype Frequency Domain Streak Camera (FDSC) that can capture the picosecond time evolution of the plasma accelerator structure in a single shot. In our prototype Frequency-Domain Streak Camera, a probe pulse propagates obliquely to a sub-picosecond pump pulse that creates an evolving nonlinear index 'bubble' in fused silica glass, supplementing a conventional Frequency Domain Holographic (FDH) probe-reference pair that co-propagates with the 'bubble'. Frequency Domain Tomography (FDT) generalizes Frequency-Domain Streak Camera by probing the 'bubble' from multiple angles and reconstructing its morphology and evolution using algorithms similar to those used in medical CAT scans. Multiplexing methods (Temporal Multiplexing and Angular Multiplexing) improve data storage and processing capability, demonstrating a compact Frequency Domain Tomography system with a single spectrometer.

43 PARTICLE ACCELERATORS↗