Search NASA⌕ Search

SEARCH · Search NASA

Results for “total cost of driving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEMONSTRATION OF A PASSIVE CONDENSER LOOP

Building HVAC consumes significant amount of energy. It is estimated that about 7% of the total electricity consumed by water cooled chiller is used to drive the condenser water pump. A passive condenser loop is developed to curb this energy consumption by replacing the open pumped loop to a closed loop thermosyphon system. The loop thermosyphon uses waste heat to circulate the condenser fluid, eliminating the electrical pumping power requirement and the large circulation pump. Since it is a closed loop, it also reduces the maintenance cost and enables both wet and dry cooling modes. A demonstration unit with a riser about 40 feet (12.2 meters) tall is fabricated and tested at powers up to 25 kW. The result has successfully showed that the loop thermosyphon is able to transfer the heat near isothermally (∆T < 0.4C) over the long distance without the need of any pump and consuming any electricity.

Loop thermosyphon, building HVAC, condenser loop↗

Effect of sample size on the maximum value distribution of fatigue driving forces in metals and alloys

An analytical framework is presented to predict the effects of sample size on the maximum value distribution (MVD) of the driving forces for fatigue crack formation in metals and alloys. The distribution of the maximum driving force for fatigue crack formation over the domain follows the generalized extreme value theory in the limit as the domain size increases to infinity. Here, a simulation-based analysis of microstructure influences on fatigue resistance for polycrystalline metals and alloys is very costly, and reaching those limits is intractable. This work models the MVD of Fatigue Indicator Parameters (FIPs), which serve as surrogate measures for the driving force for fatigue crack formation, at finite sample sizes prior to their convergence to a limiting extreme value distribution. Large-scale crystal plasticity finite element (CPFE) simulations of FCC Al 7075-T6 with microstructure realizations of various sizes are incorporated to calibrate and evaluate the developed framework, and a total of ∼6.5 million grains of Al 7075-T6 are examined. The calibrated analytical solution agrees well with the brute force Monte Carlo simulation results extracted from the CPFE simulations. Furthermore, the developed formulation can predict the MVD of FIPs for different sample sizes using a size-dependent parameter, and it is capable of accurately extrapolating the MVD of FIPs for much larger microstructure sample sizes than the size used for its calibration.

Crystal plasticity↗

Ultrafast local demagnetization in 𝑑 6 systems via driven Jahn-Teller distortions

Ultrafast control of spin orientations without relying on highly nonequilibrium electron distributions offers a new pathway for femtosecond spintronics. It is shown that excitation of specific vibronic modes can drive a substantial demagnetization of a local moment relative to the magnetization axis, while preserving its total spin quantum number. Using a fully quantum many-body treatment of a local 𝑆=2 (𝑑 6 ) many-body spin coupled to a driven Jahn-Teller mode with quantum dissipation, we find that the projected spin can be strongly reduced via a Jahn-Teller-induced 𝑥⁢𝑦↑→𝑦⁢𝑧/𝑧⁢𝑥↓ transition, which occurs without additional Coulomb exchange cost. The excited state subsequently relaxes back to its original electronic configuration with a rotated spin direction, enabling spin reorientation without generating a large net angular momentum in the electronic subsystem.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field Evaluation of the Caney Shale as an Emerging Unconventional Play, Southern Oklahoma

The Mississippian-age Caney Shale is an emerging unconventional oil and gas (UOG) resource play in the southern Midcontinent and is prospective in the Anadarko, Ardmore, Marietta and western Arkoma basins. This play is enigmatic in that time equivalent Fayetteville Shale in the eastern Arkoma basin and Barnett Shale in the Ft. Worth Basin are major unconventional plays, whereas Caney Shale production is sparse and unpredictable (Cardott, 2017). In the Anadarko, Ardmore and Marietta basins, the Caney Shale is in the oil window, but its resource potential has not been adequately assessed. The Caney reservoir is about 60-300 m thick, is rich in total organic carbon, contains a large oil resource base, and has a strong natural gas drive; however, development has been hampered by high clay content and reactivity of the formation with water. The main objective of this initial four-year research project was to address these issues by establishing a Caney Shale Field Laboratory in the Ardmore Basin of southern Oklahoma to (a) conduct a comprehensive field characterization (b) perform field experiments, and (c) validate cost-effective technologies that will lead to a comprehensive and efficient development strategy plan for Caney Shale.

02 PETROLEUM↗

Advanced turboprop testbed systems study. Volume 1: Testbed program objectives and priorities, drive system and aircraft design studies, evaluation and recommendations and wind tunnel test plans

The establishment of propfan technology readiness was determined and candidate drive systems for propfan application were identified. Candidate testbed aircraft were investigated for testbed aircraft suitability and four aircraft selected as possible propfan testbed vehicles. An evaluation of the four candidates was performed and the Boeing KC-135A and the Gulfstream American Gulfstream II recommended as the most suitable aircraft for test application. Conceptual designs of the two recommended aircraft were performed and cost and schedule data for the entire testbed program were generated. The program total cost was estimated and a wind tunnel program cost and schedule is generated in support of the testbed program.

Bradley, E. S.↗

A Low-Cost Clustered Archive Approach for Storing Remote Sensing Data

As part of NASA's Earth Observing System (EOS) Data and Information System (EOSDIS), the Moderate Resolution Imaging Spectrometer (MODIS) Data Processing System (MODAPS) is now processing data from two instruments on the EOS flag ship spacecraft Terra and Aqua. Between the two, MODAPS is generating over 1 Terrabyte of data per day and has surpassed 3 Petabytes of total data. The bulk of the data is stored near-line in StorageTek Powerhorn tape jukeboxes. Accessing data that has been moved to tape involves submitting an order, scheduling the tape, and waiting for the data to become available. I am developing a low cost clustered archive that could enable storing a very large amount of data such as the MODIS data described above in an organized fashion on a cluster of commodity hardware using low cost SATA hard drives such that the files are directly available online. The system takes full advantage of Open Source software, using the GNULinux operating system, PostgreSQL relational database and the Apache HTTP Server. This poster session will depict my approach, the interface to the archive, a brief discussion of the internals of the system and some performance numbers from my prototyping. I will also describe various costs and benefits of this approach versus the traditional large tape jukebox approach currently in use in the EOSDIS.

Tilmes, Curt↗

Precision Linear Actuators for the Spherical Primary Optical Telescope Demonstration Mirror

The Spherical Primary Optical Telescope (SPOT) is an ongoing research effort at Goddard Space Flight Center developing wavefront sensing and control architectures for future space telescopes. The 03.5 m SPOT telescope primary mirror is comprised20f 6, 0.86 m hexagonal mirror segments arranged in a single ring, with the central segment missing . The mirror segments are designed for laboratory use and are not light-weighted to reduce cost. Each primary mirror segment is actuated and has tip, tilt, and piston rigid body motions. Additionally, the radius of curvature of each mirror segment may be varied mechanically3. To provide these degrees of freedom, the SPOT mirror segment assembly requires linear actuators capable of 10 nm resolution over a total stroke of 5 mm. These actuators must withstand high static loads as they must support the mirror segment, which has a mass of approx.100 kg. A stepper motor driving a differential satellite roller screw was designed to meet these demanding requirements. Initial testing showed that the actuator is capable of sub-micron repeatability over the entire 6mm range, and was limited by 100-200 nm measurement noise levels present in the facility. Further testing must be accomplished in an isolated facility with a measurement noise floor of < 5 nm. Such a facility should be ready for use at GSFC in the early summer of 2006, and will be used to better characterize this actuator.

Budinoff, Jason↗

Production of Uranium from Seawater Using a Novel Polymer Adsorbent – Process Development and Cost Analysis (Final Scientific/Technical Report SBIR Phase II)

Research in developing techniques for extracting uranium from seawater is of considerable current interest. One reason which drives scientists to develop techniques of sequestering uranium from ocean is the prediction that the land-based uranium reserves would be depleted by the end of this century based on the current production rate. Uranium exists in seawater at a very low concentration (about 3 ppb) and as highly stable uranyl tris-carbonato complexes, primarily in the form Ca 2 [UO 2 (CO 3 ) 3 ]. Because of the enormous volume of seawater, the total amount of uranium in ocean is estimated to be a thousand times greater than the land-based uranium resources. As early as 1964, the idea of extracting uranium from seawater was discussed by Davies et al. in a Nature paper. In the past decades, many different materials were tested to evaluate their ability for sequestering uranium from seawater. Among them, amidoxime and carboxylate containing polymer fiber adsorbents appear most promising because of their high uranium adsorption capacity and stability in seawater. The carboxylate groups are necessary to make the polymer adsorbent hydrophilic whereas the amidoxime groups provide strong coordination sites for uranyl ions. Moreover, according to theoretical analysis, the adsorbability of uranium may involve synergistic effects of both amidoxime and carboxyl groups in the fiber adsorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Precision Linear Actuators for the Spherical Primary Optical Telescope Demonstration Mirror

The Spherical Primary Optical Telescope (SPOT) is an ongoing research effort at Goddard Space Flight Center developing wavefront sensing and control architectures for future space telescopes. The 03.5-m SPOT telescope primary mirror is comprise9 of six 0.86-m hexagonal mirror segments arranged in a single ring, with the central segment missing. The mirror segments are designed for laboratory use and are not lightweighted to reduce cost. Each primary mirror segment is actuated and has tip, tilt, and piston rigid-body motions. Additionally, the radius of curvature of each mirror segment may be varied mechanically. To provide these degrees of freedom, the SPOT mirror segment assembly requires linear actuators capable of <lO-nm resolution over a total stroke of 5 mm. These actuators must withstand high static loads as they must support the mirror segment, which has a mass of -100 kg. A stepper motor driving a differential satellite roller screw was designed to meet these demanding requirements. Initial testing showed that the actuator is capable of sub-micron repeatability over the entire 6-mm range, and was limited by 100-200 nm measurement noise levels present in the facility. Further testing must be accomplished in an isolated facility with a measurement noise floor of <5 nm. Such a facility should be ready for use at GSFC in the early summer of 2006, and will be used to better characterize this actuator.

Budinoff, Jason↗

Human Mars Ascent Vehicle Configuration and Performance Sensitivities

The total ascent vehicle mass drives performance requirements for the Mars descent systems and the Earth to Mars transportation elements. Minimizing Mars Ascent Vehicle (MAV) mass is a priority and minimizing the crew cabin size and mass is one way to do that. Human missions to Mars may utilize several small cabins where crew members could live for days up to a couple of weeks. A common crew cabin design that can perform in each of these applications is desired and could reduce the overall mission cost. However, for the MAV, the crew cabin size and mass can have a large impact on vehicle design and performance. This paper explores the sensitivities to trajectory, propulsion, crew cabin size and the benefits and impacts of using a common crew cabin design for the MAV. Results of these trades will be presented along with mass and performance estimates for the selected design.

Polsgrove, Tara P.↗

Thermal Analysis and Testing of Fastrac Gas Generator Design

The Fastrac Engine is being developed by the Marshall Space Flight Center (MSFC) to help meet the goal of substantially reducing the cost of access to space. This engine relies on a simple gas-generator cycle, which burns a small amount of RP-1 and oxygen to provide gas to drive the turbine and then exhausts the spent fuel. The Fastrac program envisions a combination of analysis, design and hot-fire evaluation testing. This paper provides the supporting thermal analysis of the gas generator design. In order to ensure that the design objectives were met, the evaluation tests have started on a component level and a total of 15 tests of different durations were completed to date at MSFC. The correlated thermal model results will also be compared against hot-fire thermocouple data gathered.

Nguyen, H.↗

Process design of the piperazine advanced stripper for a 460 MW NGCC

The Texas Carbon Management Program is conducting a Front-End Engineering Design (FEED) for Piperazine with the Advanced Stripper™ (PZAS™) at a natural gas combined cycle power plant in west Texas. Here, this paper presents the design of the advanced stripper system with an emphasis on the selection of packing type, packing height, column diameter, and heat exchanger size, demonstrates the effect of ambient temperature swing on the regeneration energy requirement, and investigates two alternate process configurations that provide better energy performance than PZAS™. The design uses 2 stripper trains, and each train uses two cold cross exchangers, one hot cross exchanger, a stripper column, a CO 2 exchanger, and a condenser. Each column consists of two sections of random packing with RSR 2 packing at the top and RSR 3 packing at the bottom, with a total packed height of 7.5 m. The cold exchanger was designed with an NTU of 6, the hot exchanger with an NTU of 2, and the CO 2 exchanger with an NTU of 5. At 0.4 rich loading and 0.2 lean loading, this design resulted in a heat duty of 2.85 GJ/tonne CO 2 . The heat duty can vary up to 3.1 GJ/tonne CO 2 due to lower rich loading at higher summer temperature, but the absolute steam requirement is 8–15% lower in the summer. An alternate design, PZAS with hot rich bypass, is proposed, which can reduce the equivalent work of stripping by 1.5–3.5% compared to PZAS at low heat exchanger size, due to a reduction in stripper driving force. Using a hot rich bypass increases the vapor fraction of the total rich bypass stream from 0.3 to 1 mol% compared to using the warm rich bypass, which also contributes to a reduction in lost work in the column. PZAS with hot rich bypass outperforms PZAS in energy requirement below a packing height of 15 m, but fails to do so above 15 m of packing due to a column pinch that results in little change in LMTD of the column. PZAS with hot rich bypass has the potential to minimize capital cost in addition to reducing energy requirement as it requires less packing to strip CO 2 than PZAS and requires only one cross exchanger with 8 heat transfer units.

03 NATURAL GAS↗

ICE Calculator 2.0: Final Report for Phase 1 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE 2.0 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE 2.0 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 of the ICE 2.0 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 1 involved 11 customer interruption cost survey activities representing a total of 24 electricity distribution service territories, 23 of them located in the Eastern and Midwestern regions of the U.S. and one located in the Pacific Northwest. ICE 2.0 vs. 1.0 Comparison This memorandum compares customer power interruption costs estimated using the recently updated Interruption Cost Estimate (ICE) Calculator (“ICE 2.0”) to the original ICE Calculator (“ICE 1.0”). ICE 1.0 was developed in 2009 based on 15 independent power interruption cost surveys conducted by 10 electric utilities between 1989 and 2012. ICE 2.0 was developed in 2025 through a national initiative based on a consistent set of power interruption cost surveys and 11 surveying efforts conducted across 24 electric utility service territories between 2022 and 2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

I(sup STAR), NASA's Next Step in Air-Breathing Propulsion for Space Access

The United States' National Aeronautics and Space Administration (NASA) has established a strategic plan for future activities in space. A primary goal of this plan is to make drastic improvements in the cost and safety of earth to low-earth-orbit transportation. One approach to achieving this goal is through the development of highly reusable, highly reliable space transportation systems analogous to the commercial airline system. In the year 2000, NASA selected the Rocket Based Combined Cycle (RBCC) engine as the next logical step towards this goal. NASA will develop a complete flight-weight, pump-fed engine system under the Integrated System Test of an Airbreathing Rocket (I(sup STAR)) Project. The objective of this project is develop a reusable engine capable of self-powering a vehicle through the air-augmented rocket, ramjet and scramjet modes required in all RBCC based operational vehicle concepts. The project is currently approved and funded to develop the engine through ground test demonstration. Plans are in place to proceed with flight demonstration pending funding approval. The project is in formulation phase and the Preliminary Requirements Review has been completed. The engine system and vehicle have been selected at the conceptual level. The I(sup STAR) engine concept is based on an air-breathing flowpath downselected from three configurations evaluated in NASA's Advanced Reusable Technology contract. The selected flowpath features rocket thrust chambers integrated into struts separating modular flowpath ducts, a variable geometry inlet, and a thermally choked throat. The engine will be approximately 220 inches long and 79 inches wide and fueled with a hydrocarbon fuel using liquid oxygen as the primary oxidizer candidate. The primary concept for the pump turbine drive is pressure-fed catalyzed hydrogen peroxide. In order to control costs, the flight demonstration vehicle will be launched from a B-52 aircraft. The vehicle concept is based on the Air Breathing Launch Vehicle 4 (ABLV4) lifting body configuration which has design heritage from NASA's NASP Program. The vehicle will be designed to accelerate from Mach 0.8 to Mach 7 and will be equipped with landing gear for horizontal landing. The complete vehicle, including the engine, will be designed for 25 flights and will be approximately 33 feet long with a total vehicle weight of approximately 25000 lbs.

Hutt, John J.↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Scout Benchmark Scenarios for U.S. Building Energy and CO2 Emissions to 2050

Overview and Intended Use Cases: These scenarios establish a range of futures for U.S. buildings sector energy use and CO2 emissions to 2050 using Scout (scout.energy.gov), a reproducible and granular model of U.S. building energy use, emissions, and consumer costs developed by the U.S. national labs for the U.S. Department of Energy's Building Technologies Office (BTO). Scout benchmark scenario data are suitable for the following example use cases: setting high-level policy goals for the U.S. buildings sector to 2050 (e.g., X% building CO2 emissions reductions vs. 2005 levels by 2030, Y% reductions vs. 2005 levels by 2050); exploring the effects of key dynamics driving U.S. buildings sector energy and CO2 emissions to 2050 that could be affected by policy levers (e.g., raising minimum technology performance levels; accelerating electrification and/or retrofit rates; introducing breakthrough technologies to the market); determining priority segments (regions, building types, and end use/technology types) and sequencing of U.S. buildings sector energy and CO2 emissions reductions to 2050 under a given set of assumptions; and/or identifying the energy and emissions impacts or cost effectiveness of specific technologies or operational approaches of interest—in isolation or after considering competition with other measures in a scenario portfolio. Scenario Summary: A total of 8 scenarios explore the effects of changes across both the demand- and supply-side of building energy use on annual U.S. building energy use and CO2 emissions from 2022–2050. Scenarios are organized into three groups representing low, moderate, and best-case potentials for building decarbonization, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determination of the regeneration energy of direct air capture solvents/sorbents using calorimetric methods

Regeneration energy and recyclability are important parameters that dictate the viability of a CO 2 direct air capture (DAC) process. In this study, differential scanning calorimetry (DSC) is used in conjunction with thermogravimetric analysis (TGA) and Fourier Transform Infrared Spectroscopy (FTIR) to evaluate the regeneration energy required for CO 2 -loaded 3 M aqueous potassium sarcosinate (K-SAR) solvent and crystalline methyl-glyoxal-bisiminoguanidine (MGBIG) sorbent. Based on calorimetric measurements, for aqueous K-SAR, the sensible heat amounts to 1.5 GJ/tCO 2 and the enthalpy of desorption is estimated at 3.68 GJ/tCO 2 . The total energy of regeneration will also include the enthalpy of solvent vaporization, which will depend on the thermodynamic conditions and the level of regeneration. For MGBIG, the total regeneration energy required was measured at approximately 7.0 GJ/tCO 2 . Further, FTIR measurements were used to observe CO 2 and H 2 O release during the thermal regeneration process. For K-SAR, CO 2 release is seen to take place at temperatures greater than 80 °C and, for MGBIG, the CO 2 release takes place at temperatures greater than 100 °C. The moderate temperatures required for K-SAR and MGBIG regenerations compared to other DAC solvents/sorbents suggest that low-cost sources of heat, such as geothermal heat, could potentially be used for regeneration to drive down the cost of direct air capture.

42 ENGINEERING↗