Search NASA⌕ Search

SEARCH · Search NASA

Results for “total dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A 100-Mrad (Si) JFET-based Sensing and Communications System for Extreme Nuclear Instrumentation Environments

Dry cask storage is one of two storage methods approved by the U.S. Nuclear Regulatory Commission for spent fuel after removal from reactor cores. Dry casks consist of a stainless steel canister enclosed in a concrete overpack to contain the hazardous radioactive spent fuel rods and provide radiation shielding. Monitoring spent fuel storage casks is desired to ensure the safe containment of the enclosed spent fuel, but is very difficult due to the related harsh temperature and radiation environment. The sensors and associated electronics to monitor temperature, pressure, and/or radiation need to survive high temperatures and radiation doses for extended time periods. For this reason, there is a severe need for radiation-hardened electrical systems that survive well beyond the existing capabilities of commercially available radiation-rated electronic components, which have primarily been developed for space applications. Junction-gate field-effect transistor (JFET) devices are inherently radiation hardened [exceeding 100 Mrad (Si)]. Additionally, when JFETs are used as building blocks for sensing and communication electronics (i.e., oscillators, amplifiers, filters, and mixers), inherently radiation-hardened circuits can be achieved. To this end, JFET-based radiation-hardened electronics interfacing with cask-embedded sensors capable of driving modulated sensor signals through a stainless steel barrier were designed and tested at a dose rate of approximately 500 krad/h (Si) to beyond a 200-Mrad (Si) total ionizing dose. After 200 Mrad (Si), the sensor and communication circuit signals were correctly decoded at the receiver despite oscillator drift. The results from this experiment demonstrate the potential for creating more complex radiation-hardened JFET-based electrical systems for nuclear environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pediatric dosing for locally acting drugs in submissions to the U.S. Food and Drug Administration between 2002 and 2020

Abstract Deriving pediatric doses for locally acting drugs (LADs) presents a unique challenge because limited systemic exposure hinders commonly used approaches such as pharmacokinetic matching to adults. This study systematically evaluated drug development practices used for pediatric dose selection of LADs approved by the U.S. Food and Drug Administration from 2002 to 2020. The three study objectives were: (1) to determine the dose selection approach for the labeled pediatric dose, (2) to examine the studied pediatric dose(s), and (3) to evaluate the characteristics of the pediatric clinical programs used to support the labeled pediatric dose. A total of 187 pediatric submissions were characterized for the labeled and studied pediatric doses of LADs. The pediatric dose was predominantly labeled as a flat dose (91%) and at a single‐dose level (67%) similar to adults. The majority (68.4%) of the submissions had the same labeled dose for pediatrics and adults. Independent pharmacodynamic/efficacy studies in pediatric patients commonly (64.2%) provided supportive evidence for the labeled pediatric dose. Inhalation, nasal, and injectable submissions had the highest number of clinical trials, lowest usage of an extrapolation of efficacy approach, and utilized diverse approaches in selecting the studied pediatric doses. This article highlights approaches for LAD dosing in pediatric patients and can be used to inform drug development of these products in the pediatric population.

Research & Experimental Medicine↗

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ionizing radiation effects in SONOS-based neuromorphic inference accelerators

Here, we evaluate the sensitivity of neuromorphic inference accelerators based on Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) charge trap memory arrays to total ionizing dose (TID) effects. Data retention statistics were collected for 16 Mbit of 40 nm SONOS digital memory exposed to ionizing radiation from a Co-60 source, showing good retention of the bits up to the maximum dose of 500 krad(Si). Using this data, we formulate a rate-equation-based model for the TID response of trapped charge carriers in the ONO stack, and predict the effect of TID on intermediate device states between ‘program’ and ‘erase’. This model is then used to simulate arrays of low-power, analog SONOS devices that store 8-bit neural network weights and support in situ matrix-vector multiplication. We evaluate the accuracy of the irradiated SONOS-based inference accelerator on two image recognition tasks – CIFAR-10 and the challenging ImageNet dataset – using state-of-the-art convolutional neural networks, such as ResNet-50. We find that across the datasets and neural networks evaluated, the accelerator tolerates a maximum TID between 10 krad(Si) and 100 krad(Si), with deeper networks being more susceptible to accuracy losses due to TID.

43 PARTICLE ACCELERATORS↗

The Effects of Threshold Voltage and Number of Fins per Transistor on the TID Response of GF 12LP Technology

This abstract presents a comprehensive analysis of total ionizing dose (TID) response in GlobalFoundries’ 12LP 12nm bulk FinFET technology using 10keV X-rays. Devices with higher threshold voltages (VTs) demonstrated lower increases in off-state leakage current (IDS,OFF) post-irradiation, highlighting the mitigating role of high VT in TID response. Our data shows that transistors with fewer fins exhibit superior TID resistance, implying lower susceptibility to radiation effects. Our study also probed two bias conditions, "Gate-On" and "Pass-Gate," with the former displaying more severe TID degradation. Interestingly, p-type devices displayed negligible degradation, underscoring their inherent resilience to TID effects. Additionally, medium thick n-type devices echoed the fin-count-dependent TID response observed in other transistor types, further strengthening our findings. These results underscore the importance of strategic transistor selection and design for enhancing the TID resilience of future CMOS FinFET architectures, particularly critical in radiation-intense environments.

42 ENGINEERING↗

Radiation Response of Ga 2 O 3 MOSFETs Probed via Focused Particle Beams

Gallium Oxide (Ga 2 O 3 ), particularly in its β-phase, is attracting lots of interest for high-power and high-voltage electronics due to its wide bandgap, high breakdown field, and thermal stability. This study investigates the radiation response of Ga 2 O 3 Metal-Oxide-Semiconductor Field-Effect Transistors (MOSFETs) under Total Ionizing Dose (TID) and Displacement Damage (DD) conditions, which are critical for applications in radiation environments. Utilizing a dual-beam Focused Ion Beam and Scanning Electron Microscope setup, microscale analysis of radiation effects on individual devices is performed. The findings reveal distinct behaviors under TID and DD + TID conditions, with TID leading to threshold voltage shifts due to trapped charges, while DD results in decreased drive current attributed to increased carrier scattering from lattice defects. Notably, it is demonstrated that the TID effect can be mitigated through dynamic threshold voltage adjustments and that the predicted TID from ions calculated by Monte Carlo simulations overestimates actual TID due to unaccounted charge yield effects. In conclusion, this research enhances the understanding of Ga2O3 MOSFETs' performance in harsh radiation environments, providing insights for the design of robust electronic devices for space and nuclear applications.

MOSFET↗

Effect of Gamma Radiation on TaOₓ ECRAM

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. Here, this work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaO x -based ECRAM up to 17.3 Mrad(SiO 2 ) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaO x -based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

ECRAM↗

Impact of 12-nm FinFET Technology Variations on TID Effects: A Comparative Study of GF 12LP and 12LP+ at the Transistor Level

Here, this article presents a comparative analysis of total ionizing dose (TID) response in GlobalFoundries’ (GF) 12 low-power (LP) and 12LP+12-nm bulk fin field effect transistor (FinFET) technologies using 10-keV X-rays. Our findings show that 12LP+ n-type transistors demonstrate higher sensitivity to TID degradation of the off-state leakage drain current compared to 12LP. Data indicate that for both 12LP and 12LP+, transistors with higher threshold voltages (VTs) exhibit lower off-state drain-source leakage postirradiation compared to transistors with lower VTs. Data consistently show that transistors with fewer fins per transistor show superior TID tolerance, in both 12LP and 12LP+ technologies. Lower VT transistors in both technologies display similar preirradiation leakage currents. On the other hand, higher VT transistors in 12LP+ show lower preirradiation leakage currents than those in 12LP, highlighting that the front-end-of-line of 12LP+ technology has been modified compared to 12LP. p-type devices in 12LP+ presented negligible degradation. Larger TID sensitivity in 12LP+ might be attributed to the implementation of dual-metal gate work functions, reduced halo doping, deeper source/drain (S/D) doping profiles, and/or 12LP+ having narrower fins compared to 12LP.

Dual-metal gate work functions↗

PNNL Richland Campus Radionuclide Air Emissions Report for Calendar Year 2019

This report documents radionuclide air emissions that result in the 2019 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Richland Campus MEI from routine major and minor point source emissions in 2019 from PNNL Richland Campus sources is 1.4E-5 mrem (1.4E-7 mSv) EDE. The dose from all fugitive sources is 1.3E-6 mrem (1.3E-8 mSv) EDE. The dose from radon emissions is 1.5E-10 mrem (1.5E-12 mSv) EDE. No nonroutine emissions occurred in 2019. The total radiological dose to the MEI from all PNNL Richland Campus radionuclide emissions, including fugitive emissions and radon, is 1.5E-5 mrem (1.5E-7 mSv) EDE, or more than 10,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL Richland Campus is in compliance.

40 CFR 61 Subpart H↗

PNNL Richland Campus Radionuclide Air Emissions Report for Calendar Year 2020

This report documents radionuclide air emissions that result in the 2020 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Richland Campus MEI from routine major and minor point source emissions in 2020 from PNNL Richland Campus sources is 1.5E-5 mrem (1.5E-7 mSv) EDE. The dose from all fugitive sources is 2.0E-6 mrem (2.0E-8 mSv) EDE. The dose from radon emissions is 9.3E-9 mrem (9.3E-11 mSv) EDE. No nonroutine emissions occurred in 2020. The total radiological dose to the MEI from all PNNL Richland Campus radionuclide emissions, including fugitive emissions and radon, is 1.7E-5 mrem (1.7E-7 mSv) EDE, or more than 100,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL Richland Campus is in compliance.

40 CFR 61 Subpart H↗

PNNL Richland Campus Radionuclide Air Emissions Report for Calendar Year 2021

This report documents radionuclide air emissions that result in the 2021 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Richland Campus MEI from routine major and minor point source emissions in 2021 from PNNL Richland Campus sources is 1.7E-5 mrem (1.7E-7 mSv) EDE. The dose from all fugitive sources is 1.2E-6 mrem (1.2E-8 mSv) EDE. The dose from radon emissions is 2.1E-9 mrem (2.1E-11 mSv) EDE. No nonroutine emissions occurred in 2021. The total radiological dose to the MEI from all PNNL Richland Campus radionuclide emissions, including fugitive emissions and radon, is 1.8E-5 mrem (1.8E-7 mSv) EDE, or more than 100,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL Richland Campus is in compliance.

40 CFR 61 Subpart H↗

PNNL-Richland Campus Radionuclide Air Emissions Report for Calendar Year 2022

This report documents radionuclide air emissions that result in the 2022 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Richland Campus MEI from routine major and minor point source emissions in 2022 from PNNL Richland Campus sources is 2.1E-5 mrem (2.1E-7 mSv) EDE. The dose from all fugitive sources is 1.2E-6 mrem (1.2E-8 mSv) EDE. The dose from radon emissions is 9.2E-9 mrem (9.2E-11 mSv) EDE. No nonroutine emissions occurred in 2022. The total radiological dose to the MEI from all PNNL Richland Campus radionuclide emissions, including fugitive emissions and radon, is 2.3E-5 mrem (2.3E-7 mSv) EDE, or more than 100,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL Richland Campus is in compliance.

40 CFR 61 Subpart↗

PNNL-Richland Campus Radionuclide Air Emissions Report for Calendar Year 2023

This report documents radionuclide air emissions that result in the 2023 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL-Richland campus MEI from routine emissions sources, excluding radon, in 2023 from campus sources is 2.0E-5 mrem (2.0E-7 mSv) EDE. The dose from radon emissions is 4.0E-7 mrem (4.0E-09 mSv) EDE. No nonroutine emissions occurred in 2023. The total radiological dose to the MEI from all PNNL-Richland campus radionuclide emissions, including fugitive emissions and radon, is 2.1E-5 mrem (2.1E-7 mSv) EDE, or more than 100,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL-Richland campus is in compliance.

40 CFR 61 Subpart H↗

Normal Tissue Response of Combined Temporal and Spatial Fractionation in Proton Minibeam Radiation Therapy

Proton minibeam radiation therapy, a spatial fractionation concept, widens the therapeutic window. By reducing normal tissue toxicities, it allows a temporally fractionated regime with high daily doses. However, an array shift between daily fractions can affect the tissue-sparing effect by decreasing the total peak-to-valley dose ratio. Therefore, combining temporal fractions with spatial fractionation raises questions about the impact of daily applied dose modulations, reirradiation accuracies, and total dose modulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ESH-ASI-2021-004 DOE Annual Letter (redacted markings)

File LLNL2020_DOE_GI_ANNUAL.txt was submitted electronically to the REIRS file submission. The file contains positive and zero doses for 3,308 Lawrence Livermore National Security (LLNS) and subcontractor employees. There were 96 individuals with a collective Total Effective Dose (TED) of 6,886 mrem. The 2020 data follow the DOE Radiation Exposure Monitoring Systems (REMS) format per instructions in the REMS Reporting Guide.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Dose Coefficients Implemented in MACCS

A variety of dose conversion factor files (DCF files) have been supplied for use with the MACCS code since it was initially released. For MACCS 4.2, the MACCS DCF files have been updated to include coefficients used in the computation of acute skin doses from within the MACCS software to increase functionality and to add a pseudo-organ to represent the total effective dose equivalent (TEDE) (as defined in 10 CFR 20.1003) based on International Commission on Radiological Protection (ICRP) Publication 30. This report provides a description of how these changes have been implemented and a summary of the various DCF files supplied with MACCS 4.2. The report also provides supplemental discussions to assist the reader in understanding the technical basis for the MACCS DCFs. These supplemental discussions include a summary of basic dosimetry modeling concepts and a brief review of the Federal Guidance Reports (FGRs) upon which MACCS dose coefficients have historically been based.

97 MATHEMATICS AND COMPUTING↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Base Case

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater exposure pathway as a part of the updated Hanford Site Composite Analysis (CA). The purpose of these radiological dose assessments is to provide an estimate of the cumulative radiological impacts from all screened sources of ionizing radiation and exposure routes that could potentially contribute to the projected dose to a hypothetical member of the public from both existing or future disposal facilities and other sources including past-practice discharge sites.

61 RADIATION PROTECTION AND DOSIMETRY↗