Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Trace Contaminant Testing with the Orion Atmosphere Revitalization Technology

Every spacecraft atmosphere contains trace contaminants resulting from offgassing by cabin materials and human passengers. An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). Part of the risk mitigation effort for this new technology is the study of how atmospheric trace contaminants will affect and be affected by the technology. One particular area of concern is ammonia, which, in addition to the normal spacecraft sources, can also be off-gassed by the amine-based sorbent. In the first half of 2009, tests were performed with typical cabin atmosphere levels of five of the most common trace gases, most of which had not yet been tested with this technology. A subscale sample of the sorbent was exposed to each of the chemicals mixed into a stream of moist, CO2-laden air, and the CO2 adsorption capacity of the sorbent was compared before and after the exposure. After these typical-concentration chemicals were proven to have negligible effect on the subscale sample, tests proceeded on a full-scale test article in a sealed chamber with a suite of eleven contaminants. To isolate the effects of various test rig components, several extended-duration tests were run: without injection or scrubbing, with injection and without scrubbing, with injection and scrubbing by both the test article and dedicated trace contaminant filters, and with injection and scrubbing by only the test article. The high-level results of both the subscale and full-scale tests are examined in this paper.

Button, Amy Lin↗

Trace Contaminant Testing with the Orion Atmosphere Revitalization Technology

Every spacecraft atmosphere contains trace contaminants resulting from offgassing by cabin materials and human passengers. An amine-based carbon dioxide (CO2) and water vapor sorbent in pressure-swing regenerable beds has been developed by Hamilton Sundstrand and baselined for the Orion Atmosphere Revitalization System (ARS). Part of the risk mitigation effort for this new technology is the study of how atmospheric trace contaminants will affect and be affected by the technology. One particular area of concern is ammonia, which, in addition to the normal spacecraft sources, can also be offgassed by the amine-based sorbent. In the spring of 2009, tests were performed at Johnson Space Center (JSC) with typical cabin atmosphere levels of five of the most common trace gases, most of which had not yet been tested with this technology. A subscale sample of the sorbent was exposed to each of the chemicals mixed into a stream of moist, CO2-laden air, and the CO2 adsorption capacity of the sorbent was compared before and after the exposure. After these typical-concentration chemicals were proven to have negligible effect on the subscale sample, tests proceeded on a full-scale test article in a sealed chamber with a suite of eleven contaminants. To isolate the effects of various test rig components, several extended-duration tests were run: without injection or scrubbing, with injection and without scrubbing, with injection of both contaminants and metabolic CO2 and water vapor loads and scrubbing by both the test article and dedicated trace contaminant filters, and with the same injections and scrubbing by only the test article. The high-level results of both the subscale and full-scale tests are examined in this paper.

Button, Amy B.↗

Small Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions

A principle concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has long been evaluated for use in this application and several programs are evaluating it for use in both a cabin as well as space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of small scale SA9T testing that was performed over a variety of test conditions and with a variety of trace contaminants. Testing evaluated the ability of SA9T media to sufficiently remove CO2 and H2O after exposure to a fully saturated trace contaminant at ambient conditions. Testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures during cyclic operation with a constant inlet contaminant load. In addition, testing evaluated the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream.

Broerman, Craig↗

Trace Gas Measurements on Mars and Earth Using Optical Parametric Generation

Trace gases and their isotopic ratios in planetary atmospheres offer important but subtle clues as to the origins of a planet's atmosphere, hydrology, geology, and potential for biology. An orbiting laser remote sensing instrument is capable of measuring trace gases on a global scale with unprecedented accuracy, and higher spatial resolution that can be obtained by passive instruments. We have developed an active sensing instrument for the remote measurement of trace gases in planetary atmospheres (including Earth). The technique uses widely tunable, seeded optical parametric generation (OPG) to measure methane, CO2, water vapor, and other trace gases in the near and mid-infrared spectral regions. Methane is a strong greenhouse gas on Earth and it is also a potential biogenic marker on Mars and other planets. Methane in the Earth's atmosphere survives for a shorter time than CO2 but its impact on climate change can be larger than CO2. Methane levels have remained relatively constant over the last decade around 1.78 parts per million (ppm) but recent observations indicate that methane levels may be on the rise. Increasing methane concentrations may trigger a positive feedback loop and a subsequent runaway greenhouse effect, where increasing temperatures result in increasing methane levels. The NRC Decadal Survey recognized the importance of global observations of greenhouse gases and called for simultaneous CH4, CO, and CO2 measurements but also underlined the technological limitations for these observations. For Mars, methane measurements are of great interest because of its potential as a strong biogenic marker. A remote sensing instrument that can measure day and night over all seasons and latitudes can identify and localize sources of biogenic gas plumes produced by subsurface chemistry or biology, and aid in the search for extra-terrestrial life. It can identify the dynamics of methane generation over time and latitude and identify future lander mission sites for more detailed in-situ analysis. In this paper we report on remote sensing measurements of methane using a high peak power, widely tunable optical parametric generator (OPG) operating at 3.3 micron and 1.65 micron. The OPG is pumped by a passively q-switched single frequency laser (3ns, 5KHz, 50uJ) and seeded by a diode laser. The spectral width of both signal and idler of seeded OPG is nearly Fourier transform limited. The output of seeded OPG is single frequency with high spectral purity and is widely tunable. Both 1650 nm and 3300 nm can be generated with a conversion efficiency of more than 30%. We have demonstrated detection of methane at 3274 nm and 1650 nm in a cell and also performed open path atmospheric measurements of methane at the same wavelengths. Finally, we were able to demonstrate simultaneous detection of methane at 3270.4 nm and CO2 at 1578.2 nm. In this paper we will discuss the OPG performance and atmospheric open path measurement results.

Numata, Kenji↗

Process Upsets Involving Trace Contaminant Control Systems

Paradoxically, trace contaminant control systems that suffer unexpected upsets and malfunctions can release hazardous gaseous contaminants into a spacecraft cabin atmosphere causing potentially serious toxicological problems. Trace contaminant control systems designed for spaceflight typically employ a combination of adsorption beds and catalytic oxidation reactors to remove organic and inorganic trace contaminants from the cabin atmosphere. Interestingly, the same design features and attributes which make these systems so effective for purifying a spacecraft's atmosphere can also make them susceptible to system upsets. Cabin conditions can be contributing causes of phenomena such as adsorbent "rollover" and catalyst poisoning can alter a systems performance and in some in stances release contamination into the cabin. Evidence of these phenomena has been observed both in flight and during ground-based tests. The following discussion describes specific instances of system upsets found in trace contaminant control systems, groups these specific upsets into general hazard classifications, and recommends ways to minimize these hazards.

Graf, John C.↗

Effect of Tropospheric Aerosols in Satellite-Based Trace Gas Retrieval

Scattering and absorption by tropospheric aerosol particles have an effect on the airmass factor (AMF), a fundamental quantity for trace gas concentration retrieval by inversion of satellite measurements. The interference effect depends on the aerosols micro-physical and optical properties as well as the relative distribution of the tropospheric trace gas and aerosol load. Quantifying the aerosol impact on trace gas retrieval requires a sensitivity study using radiative transfer calculations. In this presentation we will describe a recently initiated effort to characterize the aerosol-related error in trace gas retrievals when the presence of aerosol particles is not accounted in the inversion procedure. A general description of the project will be presented and preliminary results on aerosol effects on SO2 retrieved concentrations will be discussed.

Krotkov, Nickolay↗

Partial Automation of Requirements Tracing

Requirements Tracing on Target (RETRO) is software for after-the-fact tracing of textual requirements to support independent verification and validation of software. RETRO applies one of three user-selectable information-retrieval techniques: (1) term frequency/inverse document frequency (TF/IDF) vector retrieval, (2) TF/IDF vector retrieval with simple thesaurus, or (3) keyword extraction. One component of RETRO is the graphical user interface (GUI) for use in initiating a requirements-tracing project (a pair of artifacts to be traced to each other, such as a requirements spec and a design spec). Once the artifacts have been specified and the IR technique chosen, another component constructs a representation of the artifact elements and stores it on disk. Next, the IR technique is used to produce a first list of candidate links (potential matches between the two artifact levels). This list, encoded in Extensible Markup Language (XML), is optionally processed by a filtering component designed to make the list somewhat smaller without sacrificing accuracy. Through the GUI, the user examines a number of links and returns decisions (yes, these are links; no, these are not links). Coded in XML, these decisions are provided to a "feedback processor" component that prepares the data for the next application of the IR technique. The feedback reduces the incidence of erroneous candidate links. Unlike related prior software, RETRO does not require the user to assign keywords, and automatically builds a document index.

Hayes, Jane↗

Bench-Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions

A principal concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has been evaluated for use in this application and several programs are evaluating it for use in both cabin and space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of bench-scale SA9T testing that was performed under a variety of test conditions and with several different trace contaminants. Tests were conducted to determine if the capacity of the SA9T media to sufficiently remove CO2 and H2O is compromised after exposure to a fully saturated trace contaminant at ambient conditions. Tests also were conducted to evaluate the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream. In addition, testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures (29.6 KPa/4.3 psia) during cyclic operation with a constant inlet contaminant load.

Broerman, Craig↗

Miniature Trace Gas Detector Based on Microfabricated Optical Resonators

While a variety of techniques exist to monitor trace gases, methods relying on absorption of laser light are the most commonly used in terrestrial applications. Cavity-enhanced absorption techniques typically use high-reflectivity mirrors to form a resonant cavity, inside of which a sample gas can be analyzed. The effective absorption length is augmented by the cavity's high quality factor, or Q, because the light reflects many times between the mirrors. The sensitivity of such mirror-based sensors scales with size, generally making them somewhat bulky in volume. Also, specialized coatings for the high-reflectivity mirrors have limited bandwidth (typically just a few nanometers), and the delicate mirror surfaces can easily be degraded by dust or chemical films. As a highly sensitive and compact alternative, JPL is developing a novel trace gas sensor based on a monolithic optical resonator structure that has been modified such that a gas sample can be directly injected into the cavity. This device concept combines ultra-high Q optical whispering gallery mode resonators (WGMR) with microfabrication technology used in the semiconductor industry. For direct access to the optical mode inside a resonator, material can be precisely milled from its perimeter, creating an open gap within the WGMR. Within this open notch, the full optical mode of the resonator can be accessed. While this modification may limit the obtainable Q, calculations show that the reduction is not significant enough to outweigh its utility for trace gas detection. The notch can be milled from the high- Q crystalline WGMR with a focused ion beam (FIB) instrument with resolution much finer than an optical wavelength, thereby minimizing scattering losses and preserving the optical quality. Initial experimental demonstrations have shown that these opened cavities still support high-Q whispering gallery modes. This technology could provide ultrasensitive detection of a variety of molecular species in an extremely compact and robust package. With this type of modified WGMR, one can inject a gas sample into the open gap, allowing highly sensitive trace molecule detection within a roughly 1-cm volume. Other critical components of the instrument, such as the detector and a semiconductor laser, could be directly packaged with the resonator so as to not significantly increase the size of the device. Besides its low mass, volume, and power consumption, the monolithic design makes these resonators intrinsically robust devices, capable of handling significant temperature excursions, without moving parts to wear out or delicate coatings that can be easily damaged. A sensor could integrate with microfluidics technology for a chip-scale device. It could be mounted to the end of a deployable arm, or inserted into a borehole. Also, a network of individual sensors could be dispersed to monitor conditions over a wide region

Aveline, David C.↗

Quantification of Trace Chemicals Using Vehicle Cabin Atmosphere Monitor

A system to monitor the concentrations of trace chemicals in cabin atmosphere is one of the most critical components in long-duration human flight missions. The Vehicle Cabin Atmosphere Monitor (VCAM) is a miniature gas chromatograph mass spectrometer system to be used to detect and quantify trace chemicals in the International Space Station. We developed an autonomous computational process to quantify trace chemicals for use in VCAM. The process involves the design of a measured signal quantification scheme, the construction of concentration curves (i.e. the relationship between concentration and ion count measured by VCAM), the decision rule of applying high- or low-gain concentration curves, and the detection of saturation, low-signals, and outliers. When the developed quantification process is applied, the average errors of concentration for most of trace chemicals are found to be between 14% and 66%.

Lee, Seungwon↗

Enhanced Performance of Streamline-Traced External-Compression Supersonic Inlets

A computational design study was conducted to enhance the aerodynamic performance of streamline-traced, external-compression inlets for Mach 1.6. Compared to traditional external-compression, two-dimensional and axisymmetric inlets, streamline-traced inlets promise reduced cowl wave drag and sonic boom, but at the expense of reduced total pressure recovery and increased total pressure distortion. The current study explored a new parent flowfield for the streamline tracing and several variations of inlet design factors, including the axial displacement and angle of the subsonic cowl lip, the vertical placement of the engine axis, and the use of porous bleed in the subsonic diffuser. The performance was enhanced over that of an earlier streamline-traced inlet such as to increase the total pressure recovery and reduce total pressure distortion.

performance↗

Requirements and Sizing Investigation for the Constellation Space Suit Portable Life Support System Trace Contaminant Control

This presentation summarized the results of a trade study that evaluated whether trace contaminant control within the Constellation Spacesuit PLSS could be achieved without a Trace Contaminant Control System (TCCS) by relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Mallory Jennings and Dr. Glenn Waguespack studied trace contaminant generation rates to verify that values reflected the latest designs for Constellation spacesuit system pressure garment materials and PLSS hardware. They also calculated TCCS sizing and conducted a literature survey to review the latest developments in trace contaminant technologies.

Jennings, Mallory A.↗

Trace Element Abundances of Olivine-Hosted Melt Inclusions in Shergottites Northwest Africa 7397 and Robert Massif 04262

Olivine-hosted melt inclusions (MIs) may retain trapped parent magma compositions as well as record progressive differentiation while magmas crystallize and ascend towards the surface [1,2 and references therein]. Major element compositions of the MIs, especially Fe and Mg, can be affected by post-entrapment re-equilibration with their host olivine [1,2]. Therefore, Fe/Mg ratio correction is required to obtain MI bulk compositions following equilibrium with their host olivine. Partition coefficients of most of the trace elements in olivine are very low (i.e. DOL/melt<0.001). Thus, ratios of trace elements of olivine-hosted MIs are unlikely to be affected by post-entrapment re-equilibration and no correction is necessary [2]. Hence, tracking trace element behavior in MIs may constrain the composition of the parent magma and its evolution yielding insights on magma differentiation of shergottites. However, analyzing MIs for chemical compositions is a challenging task due to their low abundances and small sizes. Using a highly sensitive and precise micro-beam technique is essential to examine olivine-hosted MIs in order to measure trace element abundances. For this purpose, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an excellent tool due to its wide range of laser spot sizes (1-150 μm), ability to obtain raster analysis (several mm2) and lower detection limits (0.1 ppb) [3].

Ferdous, J.↗

Unravelling Complex Geologic Histories Using U–Pb and Trace Element Systematics of Titanite

Unravelling the spatio-temporal evolution of orogenic terranes requires a comprehensive understanding of the duration and extent of metamorphic events and hydrothermal alteration. Commonly used minerals such as zircon and monazite may not fully record geological histories in complex tectonic settings because their elemental constituents do not react under many metamorphic and metasomatic conditions. Here, we complement the current geochronological record of the Capricorn Orogen, Western Australia, with titanite U–Pb geochronology and geochemistry of felsic intrusive rocks to draw conclusions about the use of titanite in understanding the evolution of orogenic terranes. Because titanite usually incorporates common-Pb and may be variably reset by multiple metamorphic and hydrothermal events, a workflow is provided here for the systematic and robust interpretation of titanite U-Pb data. The addition of trace element data in titanite is particularly effective for differentiating whether a grain is igneous, recrystallized or metamorphic. We have developed several petrogenetic indices to differentiate these three types of titanite using Zr-in-titanite temperature, Th/U, Th/Pb, Al/(Al + Fe), light to heavy rare earth element ratio, and Eu anomalies. The addition of trace element geochemistry can also highlight anomalously radiogenic (sup 207)Pb/(sup 206)Pb reservoirs. Utilization of our workflow in the Capricorn Orogen reveals that titanite ages from the same samples as published zircon U–Pb data range from coeval to several hundreds of Myr of age difference between the two minerals. Titanite geochronology and trace element geochemistry indicates ~20 Myr of previously unrecognized prolonged cooling for the Capricorn Orogeny to ca. 1750 Ma. The spatial extent of the ca. 1210–1170 Ma part of the Mutherbukin Tectonic Event is also broadened significantly farther north and south than previously recognized. Incorporating titanite geochronology and trace geochemistry with more commonly used techniques (e.g., zircon and monazite petrochronology) extends our ability to resolve the complete history of large-scale orogenic terranes.

Hugo K. H. Olierook↗

Simultaneous Retrievals of Biomass Burning Aerosols and Trace Gases From the Ultraviolet to Near-Infrared Over Northern Thailand During the 2019 Pre-Monsoon Season

With the advent of spaceborne spectroradiometers in a geostationary constellation, measuring high spectral resolution ultraviolet–visible (UV-VIS) and selected near-/shortwave-infrared (NIR/SWIR) radiances can enable the probing of the life cycle of key atmospheric trace gases and aerosols at higher temporal resolutions over the globe. The UV-VIS measurements are important for retrieving several key trace gases (e.g., O 3 , SO 2 , NO 2 , and HCHO) and particularly for deriving aerosol characteristics (e.g., aerosol absorption and vertical profile). This study examines the merit of simultaneous retrievals of trace gases and aerosols using a ground-based spectroradiometer covering the UV-NIR to monitor their physicochemical processes and to obtain reliable aerosol information for various applications. During the 2019 pre-monsoon season over northern Thailand, we deployed a ground-based SMART–s (Spectral Measurements for Atmospheric Radiative Transfer–spectroradiometer) instrument, which is an extended-range Pandora with reliable radiometric calibration in the 330–820 nm range, to retrieve remotely sensed chemical and aerosol properties for the first time near biomass burning sources. The high spectral resolution (∼ 1.0 nm full width half maximum with ∼ 3.7 × oversampling) of sun and sky measurements from SMART–s provides several key trace gases (e.g., O 3 , NO 2 , and H 2 O) and aerosol properties covering the UV where significant light absorption occurs by the carbonaceous particles. During the measurement period, highly correlated total column amounts of NO 2 and aerosol optical thickness (т aer ) retrieved from SMART–s (correlation coefficient, R=0.74) indicated their common emissions from biomass burning events. The SMART–s retrievals of the spectral single scattering albedo (ω 0 ) of smoke aerosols showed an abrupt decrease in the UV, which is an important parameter dictating photochemical processes in the atmosphere. The values of ω 0 and column precipitable water vapor (H 2 O) gradually increase with the mixing of biomass burning smoke particles and higher water vapor concentrations when approaching the monsoon season. The retrieved ω 0 and weighted mean radius of fine-mode aerosols from SMART–s showed positive correlations with the H 2 O (R=0.81 for ω 0 at 330 nm and 0.56 for the volume-weighted mean radius), whereas the real part of the refractive index of fine-mode aerosol (n f ) showed negative correlations (R = -0.61 at 330 nm), which suggest that aerosol aging processes including hygroscopic growth (e.g., humidification and cloud processing) can be a major factor affecting the temporal trends of aerosol optical properties. Retrieved n f and ω 0 were closer to those of the water droplet (i.e., n f of about 1.33 and ω 0 of about 1.0) under lower amounts of NO 2 during the measurement period; considering that the NO 2 amounts in the smoke may indicate the aging of the plume after emission due to its short lifetime, the tendency is also consistent with active hygroscopic processes of the aerosols over this area. Retrieved UV aerosol properties from SMART–s generally support the assumed smoke aerosol models (i.e., the spectral shape of aerosol absorption) used in NASA's current satellite algorithms, and their spectral ω 0 retrievals from ground and satellites showed good agreements (R = 0.73–0.79). However, temporal and spectral variabilities in the aerosol absorption properties in the UV emphasize the importance of a realistic optical model of aerosols for further improvements in satellite retrievals.

biomass burning↗

Trace Contaminant Control Test Bed for Evaluation of TCC Prototypes with Vacuum Regenerable and Non-Regenerable Sorbents

A new Space Suit Exploration Portable Life Support System (xPLSS) is being designed, built, integrated, and tested into the Extra-Vehicular Mobility Unit (xEMU). The Trace Contaminant Control (TCC) system is a component in the oxygen ventilation loop of xPLSS that removes contaminants generated by the crewmembers’ metabolic processes. The primary trace contaminants that must be removed include ammonia (NH3), carbon monoxide (CO), formaldehyde (CH2O), and methyl mercaptan (CH3SH). The current state-of-the-art TCC sorbent is non-regenerable activated carbon. As a non-regenerable sorbent, its use negatively impacts the logistics for future missions. Thus, an ideal solution can be a vacuum-regenerable sorbent integrated with the xPLSS CO2/H2O removal system. To test new designs and sorbents, XploSafe has constructed a recirculating test bed that mimics the environment within the xPLSS by providing concentrations of the trace contaminant analytes generated at the operating temperature, humidity, pressure, and flow rates of the xPLSS. This system can perform regeneration or desorption by exposing the sorbent to a pressure swing from 4.3 psia to <1 torr over approximately 2 minutes. Using this test system, XploSafe evaluated various TCC prototypes constructed using rapid prototyping techniques and identified a process that allows vacuum regenerative TCC designs to be quickly examined for flow, pressure drop, and performance. By using toluene as a segregate for volatile organics, this test system was evaluated using both vacuum regenerable and non-regenerable sorbents to demonstrate the operational effectiveness of these sorbents in maintaining the concentrations of the trace contaminant analytes below the 7-day Spacecraft Maximum Allowable Concentrations.

Nicholas Materer↗

Syringe filtration methods for examining dissolved and colloidal trace element distributions in remote field locations

It is well-established that sampling and sample processing can easily introduce contamination into dissolved trace element samples if precautions are not taken. However, work in remote locations sometimes precludes bringing bulky clean lab equipment into the field and likewise may make timely transport of samples to the lab for processing impossible. Straightforward syringe filtration methods are described here for collecting small quantities (15 mL) of 0.45- and 0.02-microm filtered river water in an uncontaminated manner. These filtration methods take advantage of recent advances in analytical capabilities that require only small amounts of waterfor analysis of a suite of dissolved trace elements. Filter clogging and solute rejection artifacts appear to be minimal, although some adsorption of metals and organics does affect the first approximately 10 mL of water passing through the filters. Overall the methods are clean, easy to use, and provide reproducible representations of the dissolved and colloidal fractions of trace elements in river waters. Furthermore, sample processing materials can be prepared well in advance in a clean lab and transported cleanly and compactly to the field. Application of these methods is illustrated with data from remote locations in the Rocky Mountains and along the Yukon River. Evidence from field flow fractionation suggests that the 0.02-microm filters may provide a practical cutoff to distinguish metals associated with small inorganic and organic complexes from those associated with silicate and oxide colloids.

Colloids/analysis↗

Implementation of Cloud Retrievals for Tropospheric Emission Spectrometer (TES) Atmospheric Retrievals: Part 1. Description and Characterization of Errors on Trace Gas Retrievals

We develop an approach to estimate and characterize trace gas retrievals in the presence of clouds in high spectral measurements of upwelling radiance in the infrared spectral region (650-2260/cm). The radiance contribution of clouds is parameterized in terms of a set of frequency-dependent nonscattering optical depths and a cloud height. These cloud parameters are retrieved jointly with surface temperature, emissivity, atmospheric temperature, and trace gases such as ozone from spectral data. We demonstrate the application of this approach using data from the Tropospheric Emission Spectrometer (TES) and test data simulated with a scattering radiative transfer model. We show the value of this approach in that it results in accurate estimates of errors for trace gas retrievals, and the retrieved values improve over the initial guess for a wide range of cloud conditions. Comparisons are made between TES retrievals of ozone, temperature, and water to model fields from the Global Modeling and Assimilation Office (GMAO), temperature retrievals from the Atmospheric Infrared Sounder (AIRS), tropospheric ozone columns from the Goddard Earth Observing System (GEOS) GEOS-Chem, and ozone retrievals from the Total Ozone Mapping Spectrometer (TOMS). In each of these cases, this cloud retrieval approach does not introduce observable biases into TES retrievals.

aerosols↗