Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace element detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed optical microsensors for hydrogen leak detection and related applications

Significant advances have recently been made to develop optically interrogated microsensor based chemical sensors with specific application to hydrogen vapor sensing and leak detection in the hydrogen economy. We have developed functionalized polymer-film and palladium/silver alloy coated microcantilever arrays with nanomechanical sensing for this application. The uniqueness of this approach is in the use of independent component analysis (ICA) and the classi cation techniques of neural networks to analyze the signals produced by an array of microcantilever sensors. This analysis identifies and quantifies the amount of hydrogen and other trace gases physisorbed on the arrays. Selectivity is achieved by using arrays of functionalized sensors with a moderate distribution of specificity among the sensing elements. The device consists of an array of beam-shaped transducers with molecular recognition phases (MRPs) applied to one surface of the transducers. Bending moments on the individual transducers can be detected by illuminating them with a laser or an LED and then reading the reflected light with an optical position sensitive detector (PSD) such as a CCD. Judicious selection of MRPs for the array provides multiple isolated interaction surfaces for sensing the environment. When a particular chemical agent binds to a transducer, the effective surface stresses of its modified and uncoated sides change unequally and the transducer begins to bend. The extent of bending depends upon the specific interactions between the microcantilever s MRP and the analyte. Thus, the readout of a multi-MRP array is a complex multi-dimensional signal that can be analyzed to deconvolve a multicomponent gas mixture. The use of this sensing and analysis technique in unattended networked arrays of sensors for various monitoring and surveillance applications is discussed.

08 HYDROGEN↗

Dual-Comb Spectroscopy to Tethered Balloon System (DCS to TBS) Field Campaign Report

There is a critical need for the ability to detect, quantify, and attribute sources and sinks of greenhouse gases (GHGs) with high temporal and spatial resolution. Current methods are typically based on continuously operating near-surface point sensors or intermittent aerial/satellite observations. Dual optical frequency comb spectroscopy (“dual-comb spectroscopy”; DCS) is a laser-based technique that can bridge this sensing gap by providing high-precision, high-accuracy, and high-temporal-resolution detection and quantification of trace gases over kilometer-length scales, connecting local and regional observations. A single DCS system can also provide spatial resolution for source/sink attribution with the addition of a few minor optical elements, enabling cross-validation of other observations (e.g., Total Carbon Column Observing Network [TCCON], Orbiting Carbon Observatory [OCO-2/3], Greenhouse Gases Observing Satellite [GOSAT-1/2][).

54 ENVIRONMENTAL SCIENCES↗

Use of Tracer Elements for Estimating Community Exposure to Marcellus Shale Development Operations

Since 2009, unconventional natural gas development (UNGD) has significantly increased in Appalachia’s Marcellus Shale formation. Elevations of fine particulate matter <2.5 µm (PM2.5), have been documented in areas surrounding drilling operations during well stimulation. Furthermore, many communities are experiencing increased industrial activities and probable UNGD air pollutant exposures. Recent studies have associated UNGD emissions with health effects based on distances from well pads. In this study, PM2.5 filter samples were collected on an active gas well pad in Morgantown, West Virginia, and three locations downwind during hydraulic stimulation. Fine particulate samples were analyzed for major and trace elements. An experimental source identification model was developed to determine which elements appeared to be traceable downwind of the UNGD site and whether these elements corresponded to PM2.5 measurements. Results suggest that 1) magnesium may be useful for detecting the reach of UNGD point source emissions, 2) complex surface topographic and meteorological conditions in the Marcellus Shale region could be modeled and confounding sources discounted, and 3) well pad emissions may be measurable at distances of at least 7 km. If shown to be more widely applicable, future tracer studies could enhance epidemiological studies showing health effects of UNGD-associated emissions at ≥15 km.

60 APPLIED LIFE SCIENCES↗

Body burden of toxic metals and rare earth elements in non-smokers, cigarette smokers and electronic cigarette users

Highlights: • The role of smoking as a source for 42 inorganic element intakes was explored. • The exposure levels of non-smoker, cigarette smokers and e-cigarette users was compared. • Cigarette smokers showed the highest levels of Cu, Mo, Zn, Sb, and Sr. • E-cigarettes users presented the highest concentrations of Se, Ag, and V. • Be, Eu and La were detected more frequently among e-cigarette users. Smoking is considered an important source for inorganic elements, most of them toxic for human health. During the last years, there has been a significant increase in the use of e-cigarettes, although the role of them as source of inorganic elements has not been well established. A cross-sectional study including a total of 150 subjects from Brasov (Romania), divided into three groups (non-smokers, cigarette smokers and electronic cigarettes smokers) were recruited to disclose the role of smoking on the human exposure to inorganic elements. Concentration of 42 elements, including trace elements, elements in the ATSDR's priority pollutant list and rare earth elements (REE) were measured by ICP-MS in the blood serum of participants. Cigarette smokers showed the highest levels of copper, molybdenum, zinc, antimony, and strontium. Electronic cigarette (e-cigarette) users presented the highest concentrations of selenium, silver, and vanadium. Beryllium, europium and lanthanides were detected more frequently among e-cigarette users (20.6%, 23.5%, and 14.7%) than in cigarette smokers (1.7%, 19.0%, and 12.1%, respectively); and the number of detected REE was also higher among e-cigarette users (11.8% of them showed more than 10 different elements). Serum levels of cerium and erbium increased as the duration of the use of e-cigarettes was longer. We have found that smoking is mainly a source of heavy metals while the use of e-cigarettes is a potential source of REE. However, these elements were detected at low concentrations.

54 ENVIRONMENTAL SCIENCES↗

Chimbuko: A Workflow-Level Scalable Performance Trace Analysis Tool

Due to the sheer volume of data it is typically impractical to analyze the detailed performance of an HPC application running at-scale. While conventional small-scale benchmarking and scaling studies are often sufficient for simple applications, many modern workflow-based applications couple multiple elements with competing resource demands and complex inter-communication patterns for which performance cannot easily be studied in isolation and at small scale. This work discusses Chimbuko, a performance analysis framework that provides real-time, in situ anomaly detection. By focusing specifically on performance anomalies and their origin (aka provenance), data volumes are dramatically reduced without losing necessary details. To the best of our knowledge, Chimbuko is the first online, distributed, and scalable workflow-level performance trace analysis framework. We demonstrate the tool's usefulness on Oak Ridge National Laboratory's Summit system.

97 MATHEMATICS AND COMPUTING↗

Chimbuko: A Workflow-Level Scalable Performance Trace Analysis Tool

ABSTRACT Due to the sheer volume of data it is typically impractical to analyze the detailed performance of an HPC application running at-scale. While conventional small-scale benchmarking and scaling studies are often sufficient for simple applications, many modern workflow-based applications couple multiple elements with competing resource demands and complex inter-communication patterns for which performance cannot easily be studied in isolation and at small scale. This work discusses Chimbuko, a performance analysis framework that provides real-time, in situ anomaly detection. By focusing specifically on performance anomalies and their origin (aka provenance), data volumes are dramatically reduced without losing necessary details. To the best of our knowledge, Chimbuko is the first online, distributed, and scalable workflow-level performance trace analysis framework. We demonstrate the tool's usefulness on Oak Ridge National Laboratory's Summit system.

97 MATHEMATICS AND COMPUTING↗

The trace of the CNO cycle in the ring nebula NGC 6888

We present new results on the chemical composition of the Galactic ring nebula NGC 6888 surrounding the WN6(h) star WR136. The data are based on deep spectroscopical observations taken with the High Dispersion Spectrograph at the 8.2 m Subaru Telescope. The spectra cover the optical range from 3700 to 7400 Å. The effect of the CNO cycle is well-identified in the abundances of He, N, and O, while elements not involved in the synthesis such as Ar, S, and Fe present values consistent with the solar vicinity and the ambient gas. The major achievement of this work is the first detection of the faint C II λ4267 recombination line in a Wolf-Rayet nebula. This allows us to estimate the C abundance in NGC 6888 and therefore investigate for the first time the trace of the CNO cycle in a ring nebula around a Wolf-Rayet star. Although the detection of the C II line has a low signal-to-noise ratio, the C abundance seems to be higher than the predictions of recent stellar evolution models of massive stars. The Ne abundance also shows a puzzling pattern with an abundance of about 0.5 dex lower than the solar vicinity, which may be related to the action of the NeNa cycle. Attending to the constraints imposed by the dynamical timescale and the He/H and N/O ratios of the nebula, the comparison with stellar evolution models indicates that the initial mass of the stellar progenitor of NGC 6888 is between 25 M {sub ☉} and 40 M {sub ☉}.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel chemoresistive CH{sub 4} sensor with 10 ppm sensitivity based on multiwalled carbon nanotubes functionalized with SnO{sub 2} nanocrystals

Chemoresistive sensors based on multiwalled carbon nanotubes (MWCNTs) functionalized with SnO{sub 2} nanocrystals (NCs) have great potential for detecting trace gases at low concentrations (single ppm levels) at room temperature, because the SnO{sub 2} nanocrystals act as active sites for the chemisorption of gas molecules, and carbon nanotubes (CNTs) act as an excellent current carrying platform, allowing the adsorption of gas on SnO{sub 2} to modulate the resistance of the CNTs. However, uniform conjugation of SnO{sub 2} NCs with MWCNTs is challenging. An effective atomic layer deposition based approach to functionalize the surface of MWCNTs with SnO{sub 2} NCs, resulting in a novel CH{sub 4} sensor with 10 ppm sensitivity, is presented in this paper. Scanning electron microscopy, transmission electron microscopy (TEM), energy dispersive x-ray spectroscopy, and Raman spectroscopy were implemented to study the morphology, elemental composition, and the crystal quality of SnO{sub 2} functionalized MWCNTs. High resolution TEM images showed that the crystal quality of the functionalizing SnO{sub 2} NCs was of high quality with clear lattice fringes and the dimension almost three times smaller than shown thus far in literature. A lift-off based photolithography technique comprising bilayer photoresists was optimized to fabricate SnO{sub 2} functionalized MWCNTs-based chemoresistor sensor, which at room temperature can reliably sense below 10 ppm of CH{sub 4} in air. Such low level gas sensitivity, with significant reversible relative resistance change, is believed to be the direct result of the successful functionalization of the MWCNT surface by SnO{sub 2} NCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Ultra stable resonant cavity for gas analysis systems

Systems and methods for detecting trace gases utilize a resonance optical cavity and a coherent light source coupled to the cavity through a cavity coupling mirror. The cavity is constructed of a material having the same or a similar coefficient of thermal expansion as the mirror elements defining the cavity. The main (bulk) cavity material may be the same as the main (bulk) material that forms the mirror elements, or it may be different. Such resonant cavity configurations provide improved accuracy and stability as compared to existing cavity configurations based upon similar principles.

42 ENGINEERING↗

Dynamics of disentanglement, density matrix, and coherence in neutrino oscillations

In charged current weak interaction processes, neutrinos are produced in an entangled state with the charged lepton. This correlated state is disentangled by the measurement of the charged lepton in a detector at the production site. We study the dynamical aspects of disentanglement, propagation, and detection, in particular, the conditions under which the disentangled state is a coherent superposition of mass eigenstates. The appearance and disappearance far-detection processes are described from the time evolution of this disentangled 'collapsed' state. The familiar quantum mechanical interpretation and factorization of the detection rate emerges when the quantum state is disentangled on time scales much shorter than the inverse oscillation frequency, in which case the final detection rate factorizes in terms of the usual quantum mechanical transition probability provided the final density of states is insensitive to the neutrino energy difference. We suggest possible corrections for short-baseline experiments. If the charged lepton is unobserved, neutrino oscillations and coherence are described in terms of a reduced density matrix obtained by tracing out an unobserved charged lepton. The diagonal elements in the mass basis describe the production of mass eigenstates whereas the off-diagonal ones provide a measure of coherence. It is shown that coherences are of the same order of the diagonal terms on time scales up to the inverse oscillation frequency, beyond which the coherences oscillate as a result of the interference between mass eigenstates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MOLYBDENUM, RUTHENIUM, AND THE HEAVY r-PROCESS ELEMENTS IN MODERATELY METAL-POOR MAIN-SEQUENCE TURNOFF STARS

The ratios of elemental abundances observed in metal-poor stars of the Galactic halo provide a unique present-day record of the nucleosynthesis products of its earliest stars. While the heaviest elements were synthesized by the r- and s-processes, dominant production mechanisms of light trans-ironic elements were obscure until recently. This work investigates further our 2011 conclusion that the low-entropy regime of a high-entropy wind (HEW) produced molybdenum and ruthenium in two moderately metal-poor turnoff stars that showed extreme overabundances of those elements with respect to iron. Only a few, rare nucleosynthesis events may have been involved. Here we determine abundances for Mo, Ru, and other trans-Fe elements for 28 similar stars by matching spectral calculations to well-exposed near-UV Keck HIRES spectra obtained for beryllium abundances. In each of the 26 turnoff stars with Mo or Ru line detections and no evidence for s-process production (therefore old), we find Mo and Ru to be three to six times overabundant. In contrast, the maximum overabundance is reduced to factors of three and two for the neighboring elements zirconium and palladium. Since the overproduction peaks sharply at Mo and Ru, a low-entropy HEW is confirmed as its origin. The overabundance level of the heavy r-process elements varies significantly, from none to a factor of four, but is uncorrelated with Mo and Ru overabundances. Despite their moderate metallicity, stars in this group trace the products of different nucleosynthetic events: possibly very few events, possibly events whose output depended on environment, metallicity, or time.

79 ASTRONOMY AND ASTROPHYSICS↗

Preparation of Mo-Re-C samples containing Mo{sub 7}Re{sub 13}C with the β-Mn-type structure by solid state reaction of planetary-ball-milled powder mixtures of Mo, Re and C, and their crystal structures and superconductivity

Mo-Re-C compounds containing Mo{sub 7}Re{sub 13}C with the β-Mn structure were synthesized with high-melting-temperature metals Mo, Re, and C powders using a conventional solid state method with a planetary ball milling machine instead of the arc melting method. Use of the ball milling machine was necessary to obtain Mo{sub 7}Re{sub 13}C with the β-Mn structure using the solid state method. Almost single-phase Mo{sub 7}Re{sub 13}C with a trace of impurity were obtained using the synthesis method. By XRF and lattice parameter measurements on the samples, Fe element existed in the compound synthesized using the planetary ball milling machine with a pot and balls made of steel, though Fe element was not detected in the compound synthesized using a pot and balls made of tungsten carbide. The former compound containg the Fe atom did not show superconductivity but the latter compound without the Fe atom showed superconductivity at 6.1 K. - Graphical abstract: Temperature dependence of the magnetic susceptibility measured under 10 Oe for the superconducting PBM-T samples without Fe element and non-superconducting PBM-S with Fe element. The inset is the enlarged view of the data for the PBM-S sample.

36 MATERIALS SCIENCE↗

SUPERNOVA EJECTA IN THE YOUNGEST GALACTIC SUPERNOVA REMNANT G1.9+0.3

G1.9+0.3 is the youngest known Galactic supernova remnant (SNR), with an estimated supernova (SN) explosion date of {approx}1900, and most likely located near the Galactic center. Only the outermost ejecta layers with free-expansion velocities {approx}>18,000 km s{sup -1} have been shocked so far in this dynamically young, likely Type Ia SNR. A long (980 ks) Chandra observation in 2011 allowed spatially resolved spectroscopy of heavy-element ejecta. We denoised Chandra data with the spatio-spectral method of Krishnamurthy et al., and used a wavelet-based technique to spatially localize thermal emission produced by intermediate-mass elements (IMEs; Si and S) and iron. The spatial distribution of both IMEs and Fe is extremely asymmetric, with the strongest ejecta emission in the northern rim. Fe K{alpha} emission is particularly prominent there, and fits with thermal models indicate strongly oversolar Fe abundances. In a localized, outlying region in the northern rim, IMEs are less abundant than Fe, indicating that undiluted Fe-group elements (including {sup 56}Ni) with velocities >18,000 km s{sup -1} were ejected by this SN. However, in the inner west rim, we find Si- and S-rich ejecta without any traces of Fe, so high-velocity products of O-burning were also ejected. G1.9+0.3 appears similar to energetic Type Ia SNe such as SN 2010jn where iron-group elements at such high free-expansion velocities have been recently detected. The pronounced asymmetry in the ejecta distribution and abundance inhomogeneities are best explained by a strongly asymmetric SN explosion, similar to those produced in some recent three-dimensional delayed-detonation Type Ia models.

79 ASTRONOMY AND ASTROPHYSICS↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗