Search NASA⌕ Search

SEARCH · Search NASA

Results for “trajectory segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Towards adiabatic waveforms for inspiral into Kerr black holes. II. Dynamical sources and generic orbits

This is the second in a series of papers whose aim is to generate adiabatic gravitational waveforms from the inspiral of stellar-mass compact objects into massive black holes. In earlier work, we presented an accurate (2+1)D finite-difference time-domain code to solve the Teukolsky equation, which evolves curvature perturbations near rotating (Kerr) black holes. The key new ingredient there was a simple but accurate model of the singular source term based on a discrete representation of the Dirac-delta function and its derivatives. Our earlier work was intended as a proof of concept, using simple circular, equatorial geodesic orbits as a test bed. Such a source is effectively static, in that the smaller body remains at the same coordinate radius and orbital inclination over an orbit. (It of course moves through axial angle, but we separate that degree of freedom from the problem. Our numerical grid has only radial, polar, and time coordinates.) We now extend the time-domain code so that it can accommodate dynamic sources that move on a variety of physically interesting world lines. We validate the code with extensive comparison to frequency-domain waveforms for cases in which the source moves along generic (inclined and eccentric) bound geodesic orbits. We also demonstrate the ability of the time-domain code to accommodate sources moving on interesting nongeodesic worldlines. We do this by computing the waveform produced by a test mass following a kludged inspiral trajectory, made of bound geodesic segments driven toward merger by an approximate radiation loss formula.

79 ASTRONOMY AND ASTROPHYSICS↗

On-Line Use of Three-Dimensional Marker Trajectory Estimation From Cone-Beam Computed Tomography Projections for Precise Setup in Radiotherapy for Targets With Respiratory Motion

Purpose: To develop and evaluate accurate and objective on-line patient setup based on a novel semiautomatic technique in which three-dimensional marker trajectories were estimated from two-dimensional cone-beam computed tomography (CBCT) projections. Methods and Materials: Seven treatment courses of stereotactic body radiotherapy for liver tumors were delivered in 21 fractions in total to 6 patients by a linear accelerator. Each patient had two to three gold markers implanted close to the tumors. Before treatment, a CBCT scan with approximately 675 two-dimensional projections was acquired during a full gantry rotation. The marker positions were segmented in each projection. From this, the three-dimensional marker trajectories were estimated using a probability based method. The required couch shifts for patient setup were calculated from the mean marker positions along the trajectories. A motion phantom moving with known tumor trajectories was used to examine the accuracy of the method. Trajectory-based setup was retrospectively used off-line for the first five treatment courses (15 fractions) and on-line for the last two treatment courses (6 fractions). Automatic marker segmentation was compared with manual segmentation. The trajectory-based setup was compared with setup based on conventional CBCT guidance on the markers (first 15 fractions). Results: Phantom measurements showed that trajectory-based estimation of the mean marker position was accurate within 0.3 mm. The on-line trajectory-based patient setup was performed within approximately 5 minutes. The automatic marker segmentation agreed with manual segmentation within 0.36 {+-} 0.50 pixels (mean {+-} SD; pixel size, 0.26 mm in isocenter). The accuracy of conventional volumetric CBCT guidance was compromised by motion smearing ({<=}21 mm) that induced an absolute three-dimensional setup error of 1.6 {+-} 0.9 mm (maximum, 3.2) relative to trajectory-based setup. Conclusions: The first on-line clinical use of trajectory estimation from CBCT projections for precise setup in stereotactic body radiotherapy was demonstrated. Uncertainty in the conventional CBCT-based setup procedure was eliminated with the new method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fixed-range optimum trajectories for short-haul aircraft

An algorithm, based on the energy-state method, is derived for calculating optimum trajectories with a range constraint. The basis of the algorithm is the assumption that optimum trajectories consist of, at most, three segments: an increasing energy segment (climb); a constant energy segment (cruise); and a decreasing energy segment (descent). This assumption allows energy to be used as the independent variable in the increasing and decreasing energy segments, thereby eliminating the integration of a separate adjoint differential equation and simplifying the calculus of variations problem to one requiring only pointwise extremization of algebraic functions. The algorithm is used to compute minimum fuel, minimum time, and minimum direct-operating-cost trajectories, with range as a parameter, for an in-service CTOL aircraft and for an advanced STOL aircraft. For the CTOL aircraft and the minimum-fuel performance function, the optimum controls, consisting of air-speed and engine power setting, are continuous functions of the energy in both climb and descent as well as near the maximum or cruise energy. This is also true for the STOL aircraft except in the descent where at one energy level a nearly constant energy dive segment occurs, yielding a discontinuity in the airspeed at that energy. The reason for this segment appears to be the relatively high fuel flow at idle power of the engines used by this STOL aircraft. Use of a simplified trajectory which eliminates the dive increases the fuel consumption of the total descent trajectory by about 10 percent and the time to fly the descent by about 19 percent compared to the optimum.

Erzberger, H.↗

Mesh-Based Entry Vehicle and Explosive Debris Re-Contact Probability Modeling

The risk to a crewed vehicle arising from potential re-contact with fragments from an explosive breakup of any jettisoned spacecraft segments during entry has long sought to be quantified. However, great difficulty lies in efficiently capturing the potential locations of each fragment and their collective threat to the vehicle. The method presented in this paper addresses this problem by using a stochastic approach that discretizes simulated debris pieces into volumetric cells, and then assesses strike probabilities accordingly. Combining spatial debris density and relative velocity between the debris and the entry vehicle, the strike probability can be calculated from the integral of the debris flux inside each cell over time. Using this technique it is possible to assess the risk to an entry vehicle along an entire trajectory as it separates from the jettisoned segment. By decoupling the fragment trajectories from that of the entry vehicle, multiple potential separation maneuvers can then be evaluated rapidly to provide an assessment of the best strategy to mitigate the re-contact risk.

McPherson, Mark A.↗

Autolanding Trajectory Design for the X-34

An Autolanding I-load Program (ALIP) is developed to design unpowered autolanding trajectories for the X-34 Mach 8 vehicle. The trajectory is comprised of geometric flight segments that are based on the shuttle approach and landing design (steep glideslope, circular flare, exponential flare to shallow glideslope). Enforcing physical constraints such as loads, vertical descent rate, continuity and smoothness reduces the design problem to a two point boundary value problem with conditions on the initial and final dynamic pressure. Finding a solution required the development of trajectory simulation techniques that constrained the flight profile to a prescribed geometry. The design methodology can be extended beyond the autolanding flight regime by repeating the series of geometric segments and solving multiple two-point boundary values problems (one for each series). The techniques described in this paper facilitate rapid design of reference trajectories.

Barton, Gregg H.↗

SU-D-207A-05: Investigating Sparse-Sampled MRI for Motion Management in Thoracic Radiotherapy

Purpose: Sparse sampling and reconstruction-based MRI techniques represent an attractive strategy to achieve sufficiently high image acquisition speed while maintaining image quality for the task of radiotherapy guidance. In this study, we examine rapid dynamic MRI using a sparse sampling sequence k-t BLAST in capturing motion-induced, cycle-to-cycle variations in tumor position. We investigate the utility of long-term MRI-based motion monitoring as a means of better characterizing respiration-induced tumor motion compared to a single-cycle 4DCT. Methods: An MRI-compatible, programmable, deformable lung motion phantom with eleven 1.5 ml water marker tubes was placed inside a 3.0 T whole-body MR scanner (Philips Ingenia). The phantom was programmed with 10 lung tumor motion traces previously recorded using the Synchrony system. 2D+t image sequences of a coronal slice were acquired using a balanced-SSFP sequence combined with k-t BLAST (accn=3, resolution=0.66×0.66×5 mm3; acquisition time = 110 ms/slice). kV fluoroscopic (ground truth) and 4DCT imaging was performed with the same phantom setup and motion trajectories. Marker positions in all three modalities were segmented and tracked using an opensource deformable image registration package, NiftyReg. Results: Marker trajectories obtained from rapid MRI exhibited <1 mm error compared to kv Fluoro trajectories in the presence of complex motion including baseline shifts and changes in respiratory amplitude, indicating the ability of MRI to monitor motion with adequate geometric fidelity for the purpose of radiotherapy guidance. In contrast, the trajectory derived from 4DCT exhibited significant errors up to 6 mm due to cycle-to-cycle variations and baseline shifts. Consequently, 4DCT was found to underestimate the range of marker motion by as much as 50%. Conclusion: Dynamic MRI is a promising tool for radiotherapy motion management as it permits for longterm, dose-free, soft-tissue-based monitoring of motion, yielding richer and more accurate information about tumor position and motion range compared to the current state-of-the-art, 4DCT. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

Orbit-determination performance of Doppler data for interplanetary cruise trajectories. Part 2: 8.4-GHz performance and data-weighting strategies

A consider error covariance analysis was performed in order to investigate the orbit-determination performance attainable using two-way (coherent) 8.4-GHz (X-band) Doppler data for two segments of the planned Mars Observer trajectory. The analysis includes the effects of the current level of calibration errors in tropospheric delay, ionospheric delay, and station locations, with particular emphasis placed on assessing the performance of several candidate elevation-dependent data-weighting functions. One weighting function was found that yields good performance for a variety of tracking geometries. This weighting function is simple and robust; it reduces the danger of error that might exist if an analyst had to select one of several different weighting functions that are highly sensitive to the exact choice of parameters and to the tracking geometry. Orbit-determination accuracy improvements that may be obtained through the use of calibration data derived from Global Positioning System (GPS) satellites also were investigated, and can be as much as a factor of three in some components of the spacecraft state vector. Assuming that both station-location errors and troposphere calibration errors are reduced simultaneously, the recommended data-weighting function need not be changed when GPS calibrations are incorporated in the orbit-determination process.

Ulvestad, J. S.↗

WE-AB-303-08: Direct Lung Tumor Tracking Using Short Imaging Arcs

Purpose: Most current tumor tracking technologies rely on implanted markers, which suffer from potential toxicity of marker placement and mis-targeting due to marker migration. Several markerless tracking methods have been proposed: these are either indirect methods or have difficulties tracking lung tumors in most clinical cases due to overlapping anatomies in 2D projection images. We propose a direct lung tumor tracking algorithm robust to overlapping anatomies using short imaging arcs. Methods: The proposed algorithm tracks the tumor based on kV projections acquired within the latest six-degree imaging arc. To account for respiratory motion, an external motion surrogate is used to select projections of the same phase within the latest arc. For each arc, the pre-treatment 4D cone-beam CT (CBCT) with tumor contours are used to estimate and remove the contribution to the integral attenuation from surrounding anatomies. The position of the tumor model extracted from 4D CBCT of the same phase is then optimized to match the processed projections using the conjugate gradient method. The algorithm was retrospectively validated on two kV scans of a lung cancer patient with implanted fiducial markers. This patient was selected as the tumor is attached to the mediastinum, representing a challenging case for markerless tracking methods. The tracking results were converted to expected marker positions and compared with marker trajectories obtained via direct marker segmentation (ground truth). Results: The root-mean-squared-errors of tracking were 0.8 mm and 0.9 mm in the superior-inferior direction for the two scans. Tracking error was found to be below 2 and 3 mm for 90% and 98% of the time, respectively. Conclusions: A direct lung tumor tracking algorithm robust to overlapping anatomies was proposed and validated on two scans of a lung cancer patient. Sub-millimeter tracking accuracy was observed, indicating the potential of this algorithm for real-time guidance applications.

60 APPLIED LIFE SCIENCES↗

Computer aided control of a mechanical arm

A method for computer-aided remote control of a six-degree-of-freedom manipulator arm involved in the on-orbit servicing of a spacecraft is presented. The control configuration features a supervisory type of control in which each of the segments of a module exchange trajectory is controlled automatically under human supervision, with manual commands to proceed to the next step and in the event of a failure or undesirable outcome. The implementation of the supervisory system is discussed in terms of necessary onboard and ground- or Orbiter-based hardware and software, and a one-g demonstration system built to allow further investigation of system operation is described. Possible applications of the system include the construction of satellite solar power systems, environmental testing and the control of heliostat solar power stations.

Derocher, W. L., Jr.↗

Rotorcraft Noise Abatement Flight Path Modeling

This report addresses development of a rotor state/trim modeling capability for noise modeling of decelerating rotorcraft approaches. The resulting technique employs discretization of the descent trajectory as multiple steady state segments for input to CAMRAD.Mod 1 to predict rotor states for acoustic analysis. Deceleration is included by modifying the CAMRAD.Mod 1 free flight trim options to allow trim to the specified acceleration/deceleration components.

Murty, Hema↗

Navigation/Prop Software Suite

Navigation (Nav)/Prop software is used to support shuttle mission analysis, production, and some operations tasks. The Nav/Prop suite containing configuration items (CIs) resides on IPS/Linux workstations. It features lifecycle documents, and data files used for shuttle navigation and propellant analysis for all flight segments. This suite also includes trajectory server, archive server, and RAT software residing on MCC/Linux workstations. Navigation/Prop represents tool versions established during or after IPS Equipment Rehost-3 or after the MCC Rehost.

Bruchmiller, Tomas↗

Vertical Navigation Control Laws and Logic for the Next Generation Air Transportation System

A vertical navigation (VNAV) outer-loop control system was developed to capture and track the vertical path segments of energy-efficient trajectories that are being developed for high-density operations in the evolving Next Generation Air Transportation System (NextGen). The VNAV control system has a speed-on-elevator control mode to pitch the aircraft for tracking a calibrated airspeed (CAS) or Mach number profile and a path control mode for tracking the VNAV altitude profile. Mode control logic was developed for engagement of either the speed or path control modes. The control system will level the aircraft to prevent it from flying through a constraint altitude. A stability analysis was performed that showed that the gain and phase margins of the VNAV control system significantly exceeded the design gain and phase margins. The system performance was assessed using a six-deg-of-freedom non-linear transport aircraft simulation and the performance is illustrated with time-history plots of recorded simulation data.

Hueschen, Richard M.↗

Elastic Model Transitions: a Hybrid Approach Utilizing Quadratic Inequality Constrained Least Squares (LSQI) and Direct Shape Mapping (DSM)

A method for transitioning linear time invariant (LTI) models in time varying simulation is proposed that utilizes both quadratically constrained least squares (LSQI) and Direct Shape Mapping (DSM) algorithms to determine physical displacements. This approach is applicable to the simulation of the elastic behavior of launch vehicles and other structures that utilize multiple LTI finite element model (FEM) derived mode sets that are propagated throughout time. The time invariant nature of the elastic data for discrete segments of the launch vehicle trajectory presents a problem of how to properly transition between models while preserving motion across the transition. In addition, energy may vary between flex models when using a truncated mode set. The LSQI-DSM algorithm can accommodate significant changes in energy between FEM models and carries elastic motion across FEM model transitions. Compared with previous approaches, the LSQI-DSM algorithm shows improvements ranging from a significant reduction to a complete removal of transients across FEM model transitions as well as maintaining elastic motion from the prior state.

Jurenko, Robert J.↗

Tracking Virtual Trajectories

Current models of smooth pursuit eye movements assume that it is largely driven by retinal image motion. We tested this hypothesis by measuring pursuit of elliptical motion (3.2s, 0.9 Hz, 1.4 deg x 1.6 deg, 4 randomly interleaved phases) of either a small spot ("real" motion) or of a line-figure diamond viewed through apertures such that only the motion of four isolated oblique line segments was visible ("virtual" motion). Each segment moved sinusoidally along a linear trajectory yet subjects perceived a diamond moving along an elliptical path behind the aperture. We found, as expected, that real motion produced accurate tracking (N = 2) with mean gain (over horizontal and vertical) of 0.9, mean phase of -6 deg (lag), mean relative phase (H vs V) of 90 +/- 8 deg (RMS error). Virtual motion behind an X-shaped aperture (N= 4 with one naive) yielded a mean gain of 0.7, mean phase of -11 deg, mean relative phase of 87 +/- 15 deg. We also measured pursuit with the X-shaped aperture using a higher segment luminance which prevents the segments from being grouped into a coherently moving diamond while keeping the motion otherwise identical. In this incoherent case, the same four subjects no longer showed consistent elliptical tracking (RMS error in relative phase rose to 60 deg) suggesting that perceptual coherence is critical. Furthermore, to rule out tracking of the centroid, we also used vertical apertures so that all segment motion was vertical (N = 3). This stimulus still produced elliptical tracking (mean relative phase of 84 +/- 19 deg), albeit with a lower gain (0.6). These data show that humans can track moving objects reasonably accurately even when the trajectory can only be derived by spatial integration of motion signals. Models that merely seek to minimize retinal or local stimulus motion cannot explain these results.

Stone, Leland S.↗

WE-AB-303-05: Breathing Motion of Liver Segments From Fiducial Tracking During Robotic Radiosurgery and Comparison with 4D-CT-Derived Fiducial Motion

Purpose: To quantify respiratory-induced motion of liver segments using the positions of implanted fiducials during robotic radiosurgery. This study also compared fiducial motion derived from four-dimensional computed tomography (4D-CT) maximum intensity projections (MIP) with motion derived from imaging during treatment. Methods: Forty-two consecutive liver patients treated with liver ablative radiotherapy were accrued to an ethics approved retrospective study. The liver segment in which each fiducial resided was identified. Fiducial positions throughout each treatment fraction were determined using orthogonal kilovoltage images. Any data due to patient repositioning or motion was removed. Mean fiducial positions were calculated. Fiducial positions beyond two standard deviations of the mean were discarded and remaining positions were fit to a line segment using least squares minimization (LSM). For eight patients, fiducial motion was derived from 4D-CT MIPs by calculating the CT number weighted mean position of the fiducial on each slice and fitting a line segment to these points using LSM. Treatment derived fiducial trajectories were corrected for patient rotation and compared to MIP derived trajectories. Results: The mean total magnitude of fiducial motion across all liver segments in left-right, anteroposterior, and superoinferior (SI) directions were 3.0 ± 0.2 mm, 9.3 ± 0.4 mm, and 20.5 ± 0.5 mm, respectively. Differences in per-segment mean fiducial motion were found with SI motion ranging from 12.6 ± 0.8 mm to 22.6 ± 0.9 mm for segments 3 and 8, respectively. Large, varied differences between treatment and MIP derived motion at simulation were found with the mean difference for SI motion being 2.6 mm (10.8 mm standard deviation). Conclusion: The magnitude of liver fiducial motion was found to differ by liver segment. MIP derived liver fiducial motion differed from motion observed during treatment, implying that 4D-CTs may not accurately capture the range of liver motion across fractions and during treatment. Author V. Nair was funded by the Cushing estate for a SABR clinical research fellowship.

60 APPLIED LIFE SCIENCES↗

The ASAC Flight Segment and Network Cost Models

To assist NASA in identifying research art, with the greatest potential for improving the air transportation system, two models were developed as part of its Aviation System Analysis Capability (ASAC). The ASAC Flight Segment Cost Model (FSCM) is used to predict aircraft trajectories, resource consumption, and variable operating costs for one or more flight segments. The Network Cost Model can either summarize the costs for a network of flight segments processed by the FSCM or can be used to independently estimate the variable operating costs of flying a fleet of equipment given the number of departures and average flight stage lengths.

Kaplan, Bruce J.↗

Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring

Purpose: Ultrashort echo time (UTE) MRI has been proposed as a way to produce segmented attenuation maps for PET, as it provides contrast between bone, air, and soft tissue. However, UTE sequences require samples to be acquired during rapidly changing gradient fields, which makes the resulting images prone to eddy current artifacts. In this work it is demonstrated that this can lead to misclassification of tissues in segmented attenuation maps (AC maps) and that these effects can be corrected for by measuring the true k-space trajectories using a magnetic field camera. Methods: The k-space trajectories during a dual echo UTE sequence were measured using a dynamic magnetic field camera. UTE images were reconstructed using nominal trajectories and again using the measured trajectories. A numerical phantom was used to demonstrate the effect of reconstructing with incorrect trajectories. Images of an ovine leg phantom were reconstructed and segmented and the resulting attenuation maps were compared to a segmented map derived from a CT scan of the same phantom, using the Dice similarity measure. The feasibility of the proposed method was demonstrated inin vivo cranial imaging in five healthy volunteers. Simulated PET data were generated for one volunteer to show the impact of misclassifications on the PET reconstruction. Results: Images of the numerical phantom exhibited blurring and edge artifacts on the bone–tissue and air–tissue interfaces when nominal k-space trajectories were used, leading to misclassification of soft tissue as bone and misclassification of bone as air. Images of the tissue phantom and thein vivo cranial images exhibited the same artifacts. The artifacts were greatly reduced when the measured trajectories were used. For the tissue phantom, the Dice coefficient for bone in MR relative to CT was 0.616 using the nominal trajectories and 0.814 using the measured trajectories. The Dice coefficients for soft tissue were 0.933 and 0.934 for the nominal and measured cases, respectively. For air the corresponding figures were 0.991 and 0.993. Compared to an unattenuated reference image, the mean error in simulated PET uptake in the brain was 9.16% when AC maps derived from nominal trajectories was used, with errors in the SUV{sub max} for simulated lesions in the range of 7.17%–12.19%. Corresponding figures when AC maps derived from measured trajectories were used were 0.34% (mean error) and −0.21% to +1.81% (lesions). Conclusions: Eddy current artifacts in UTE imaging can be corrected for by measuring the true k-space trajectories during a calibration scan and using them in subsequent image reconstructions. This improves the accuracy of segmented PET attenuation maps derived from UTE sequences and subsequent PET reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-Negative Matrix Factorization of Partial Track Data for Motion

This paper addresses the problem of segmenting low level partial feature point tracks belonging to multiple motions. We show that the local velocity vectors at each instant of the trajectory are an effective basis for motion segmentation. We decompose the velocity profiles of point tracks into different motion components and corresponding nonnegative weights using non-negative matrix factorization (NNMF). We then segment the different motions using spectral clustering on the derived weights. We test our algorithm on the Hopkins 155 benchmarking database and several new sequences, demonstrating that the proposed algorithm can accurately segment multiple motions at a speed of a few seconds per frame. We show that our algorithm is particularly successful on low-level tracks from real-world video that are fragmented, noisy and inaccurate

Computer Vision↗