Search NASA⌕ Search

SEARCH · Search NASA

Results for “trapped”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electron trapping in neutron-irradiated silicon studied by space-charge-limited current.

The trapping and detrapping of electrons is studied through measurements of space-charge-limited current in the temperature range of 77 to 293 K in high-purity silicon after irradiation with 14-MeV neutrons. A model is developed which describes most of the results quantitatively and self-consistently, including dc characteristics. Two distinct trap levels exist: the fast levels lie at 0.14 (plus or minus 0.005) eV below the conduction band, and the slow levels lie at 0.47 (plus or minus 0.01) eV below the conduction band. At 77 K, injected free electrons are initially captured by the fast 0.14-eV traps and then sink into the deep 0.47-eV traps, predominantly without being reemitted into the band. Above approximately 110 K, the detrapping rate from the shallow traps becomes so fast that the deep traps dominate. The results also offer a direct verification of the simple model of space-charge-limited current dominated by shallow and deep traps.

Quat, V. T.↗

Characteristics of trapped proton anisotropy at Space Station Freedom altitudes

The ionizing radiation dose for spacecraft in low-Earth orbit (LEO) is produced mainly by protons trapped in the Earth's magnetic field. Current data bases describing this trapped radiation environment assume the protons to have an isotropic angular distribution, although the fluxes are actually highly anisotropic in LEO. The general nature of this directionality is understood theoretically and has been observed by several satellites. The anisotropy of the trapped proton exposure has not been an important practical consideration for most previous LEO missions because the random spacecraft orientation during passage through the radiation belt 'averages out' the anisotropy. Thus, in spite of the actual exposure anisotropy, cumulative radiation effects over many orbits can be predicted as if the environment were isotropic when the spacecraft orientation is variable during exposure. However, Space Station Freedom will be gravity gradient stabilized to reduce drag, and, due to this fixed orientation, the cumulative incident proton flux will remain anisotropic. The anisotropy could potentially influence several aspects of Space Station design and operation, such as the appropriate location for radiation sensitive components and experiments, location of workstations and sleeping quarters, and the design and placement of radiation monitors. Also, on-board mass could possible be utilized to counteract the anisotropy effects and reduce the dose exposure. Until recently only omnidirectional data bases for the trapped proton environment were available. However, a method to predict orbit-average, angular dependent ('vector') trapped proton flux spectra has been developed from the standard omnidirectional trapped proton data bases. This method was used to characterize the trapped proton anisotropy for the Space Station orbit (28.5 degree inclination, circular) in terms of its dependence on altitude, solar cycle modulation (solar minimum vs. solar maximum), shielding thickness, and radiation effect (silicon rad and rem dose).

Armstrong, T. W.↗

Linear ion trap for second-order Doppler shift reduction in frequency standard applications

The authors have designed and are presently testing a novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. This new trap should store about 20 times the number of ions as a conventional RF trap with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced. The authors have succeeded in trapping mercury ions and xenon ions in the presence of helium buffer gas. Trap times as long as 2000 s have been measured.

Prestage, John D.↗

Analytic potential in a linear radio-frequency quadrupole trap with cylindrical electrodes

An analytical expression is derived for a radio-frequency ion trap of novel configuration consisting of a four-sectored hollow cylinder enclosed between two end caps. The cylindrical geometry of the sectored trap provides shielding against the buildup of charge and also makes it possible to calculate the potential within the trap by solving Laplace's equation for given boundary conditions. Equations are presented for calculating the time-averaged potential generated by the RF fields, the end-cap potential, and the potential arising from the application of a dc bias on two of the four electrode sectors. It is shown that, near the ends of this trap, the effective potential arising from the RF fields acts to propel ions out of the trap and that the addition of a dc bias on two neighboring sectors generates an inhomogeneous field in the trap which produces a force on the ions along the trap's long axis in a direction dependent on the sign of the bias.

Melbourne, R. K.↗

Locating Electron Traps In A CCD

"Pocket pumping" is technique for mapping sizes of electron-trapping defects and picture elements within which traps located in charge-coupled device (CCD). Two kinds of traps: forward and reverse. Pocket pumping relies on fact that in terms of charges measurable by external circuitry, forward traps affect only forward, while reverse traps affect only reverse, transfer of charge along row or column of picture elements. Charges in picture elements shifted back and forth many times to amplify trapping effect by repetition. Traps smaller than 1 electron detected by this method.

Janesick, James↗

LET spectra of trapped anomalous cosmic rays in low-Earth orbit

Observations aboard Cosmos satelites discovered trapped anomalous cosmic rays (ACRs), tracked the variation in their intensity in 1986-1988, and measured their fluence, spectrum, and composition at solar minimum in the previous solar cycle. The MAST instrument aboard the SAMPEX satellite has observed trapped anomalous cosmic rays in the present solar cycle, confirmed the general features of the Cosmos data, and provided the first detailed observations of trapped ACRs. In this paper we apply theoretical modeling of trapped ACRs, which is shown to provide a reasonably good description of both the Cosmos and SAMPEX data, to calculate the integral linear-energy-transfer (LET) spectra due to trapped ACRs in typical low-Earth orbits. We compare these calculations with the LET spectra produced by galactic cosmic rays (GCRs) and non-trapped ACRs in order to assess the relative radiation hazard posed by trapped ACRs.

Tylka, A. J.↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axial, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions.

Pearson, J. B.↗

Recent Operational Experience with the Internal Thermal Control System Dual-Membrane Gas Trap

A dual-membrane gas trap is currently used to remove gas bubbles from the Internal Thermal Control System (ITCS) coolant on board the International Space Station. The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the gas bubbles. The inner hydrophobic fiber allows the trapped gas bubbles to pass through and vent to the ambient atmosphere in the cabin. The gas removal performance and operational lifetime of the gas trap have been affected by contamination in the ITCS coolant. However, the gas trap has performed flawlessly with regard to its purpose of preventing gas bubbles from causing depriming, overspeed, and shutdown of the ITCS pump. This paper discusses on-orbit events over the course of the last year related to the performance and functioning of the gas trap.

Leimkuehler, Thomas O.↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Pressure Fluctuations due to ‘Trapped Waves’ in Heated Jets

An experimental study was conducted to investigate the presence and characteristics of ‘trapped waves’ in the near field of a small axisymmetric jet at heated conditions. Trapped waves occur within the potential core of compressible jets and manifest as distinct peaks in the unsteady pressure spectra measured just outside the jet near the nozzle exit. The existence and properties of the trapped wave spectral peaks in round and rectangular jets of various sizes in subsonic and supersonic conditions were studied in our recent experiments, at cold conditions [7]. The current work extends the study to heated jets. Pressure fluctuation spectra near the nozzle exit are analyzed for a small (D = 6.35 mm) axisymmetric jet at stagnation temperature ratios up to 1.6. It is shown that trapped waves continue to persist in heated jets. At sufficiently high Mach numbers, one of the trapped wave harmonics emerges as screech tone, a behavior consistent with that observed in cold jets. For a given Mach number, the frequencies of both trapped waves and screech increase with jet temperature with no significant change occurring in their amplitudes. The Strouhal numbers based on jet diameter for the trapped waves and screech continue to follow similar scaling laws as observed previously with cold jets.

aeroacoustics↗

Ablation loading of barium ions into a surface-electrode trap

Trapped-ion quantum information processing may benefit from qubits encoded in isotopes that are practically available in only small quantities, e.g., due to low natural abundance or radioactivity. Laser ablation provides a method of controllably liberating neutral atoms or ions from low-volume targets, but energetic ablation products can be difficult to confine in the small ion-electrode distance, micron-scale microfabricated traps amenable to high-speed, high-fidelity manipulation of ion arrays. Here, we investigate ablation-based ion loading into surface-electrode traps of different sizes to test a model describing ion loading probability as a function of effective trap volume and other trap parameters. We characterize loading of ablated barium from a metallic source in two cryogenic surface-electrode traps with 730 and 50 μm ion-electrode distances. Furthermore, our loading rate agrees with a predictive analytical model, providing insight for the confinement of limited-quantity species of interest for quantum computing, simulation, and sensing.

74 ATOMIC AND MOLECULAR PHYSICS↗

Surface Trap Dynamics and Gamma‐Ray Detection Enhancement in Passivated FAPbBr 3 Perovskite Crystals

Perovskite‐based direct radiation detectors offer a compelling platform for room‐temperature gamma spectroscopy due to their high sensitivity, tunable optoelectronic properties, and compatibility with solution processing. While prior studies on formamidinium lead tribromide (FAPbBr 3 ) have shown that surface passivation mitigates deep trap state impact on the charge collection efficiency (CCE), the influence of surface‐based shallow traps on time‐resolved detector response remains largely unexplored. In this article, a digital signal processing (DSP) method is applied to analyze waveform rising edge dynamics in FAPbBr 3 single‐crystal detectors, identifying prompt and delayed charge collection components. Using the second derivative of the collected charge signal, the onset of shallow trap reemission is isolated, occurring 1.1 µs after carrier generation. Surface passivation suppressed deep trap states, shifting carrier occupancy toward shallower traps and extending the temporal window of delayed charge collection. This delayed contribution correlates with measurable changes in the temporal and amplitude distributions of detector events. By leveraging time‐domain filtering informed by these dynamics, a selective enhancement in signal quality and gamma peak‐to‐Compton ratio (PCR) is achieved, while preserving over 90% of photoelectric events. An improvement in the PCR to 1.80, from the original 1.09, is enabled by focusing on high collection efficiency events corresponding to reemitted carriers in the 1.1 to 3 µs range after the generation event. These results demonstrate a pathway for leveraging shallow trap dynamics to enhance spectral fidelity in time‐resolved perovskite detectors.

36 MATERIALS SCIENCE↗

Hole Trapping at Acceptor Impurities and Alloying Elements in AlN

Hole localization is a root cause of difficulties in p-type doping of aluminum nitride. Herein, the stability of localized holes in AlN and their susceptibility to self-trapping within bulk material or in the presence of isovalent elements and acceptor impurities are calculated. It is found that self-trapped holes are metastable in bulk AlN, and also exhibit a very low barrier to detrapping. However, holes become trapped in the presence of acceptor impurities as well as isovalent elements such as B, In, and Sc, and may contribute to the broad luminescence observed in AlN alloys. It is also found that hole trapping contributes to the large ionization energies for acceptors in AlN. Most acceptors can also trap a second hole, becoming positively charged and further exacerbating difficulties in doping aluminum nitride p type. Furthermore, the stability of trapped holes is found to scale with atomic size mismatch to Al.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing the lean hydrocarbon NO x trap: Sequential and dual-layer configurations

Vehicular emission control catalysts are ineffective in eliminating CO, hydrocarbons, and NO x during engine cold-start when exhaust temperatures are below 200 °C. In this study the performance of coupled low temperature NO x , n-C 12 H 26 (C 12 ), and C 3 H 6 trapping, release and conversion for a series of model Lean Hydrocarbon NO x Trap (LHCNT) catalysts are examined. Pd and Pt supported on small-pore (SSZ-13) and large-pore (BEA) zeolites are selected based on the performance during transient NO and C 12 uptake, release and conversion experiments. These catalysts are combined into sequential (Pt + Pd/BEA → Pd/SSZ-13; Pd/SSZ-13 → Pt + Pd/BEA) and dual-layer (Pt + Pd/BEA top, Pd/SSZ-13 bottom) configurations in an attempt to improve the trapping and conversion performance. While all three configurations trap between 75 and 100 μmolNO x /g-cat, the Pd/SSZ-13 → Pt + Pd/BEA sequential configuration is most effective in simultaneously trapping C 12 and NO in the presence of H 2 O, resulting in excellent NO and C 12 storage below 100 °C with release and/or conversion at or above 200 °C. For each configuration, C 12 oxidation lights-off below 300 °C and NO oxidation achieves ~35 % conversion in the absence of C 12 . Neither the presence of C 12 nor the order of the sequential configuration has a significant impact on NO uptake. C 12 significantly delays NO and NO 2 desorption to temperatures exceeding 300 °C. The more compact dual-layer catalyst is most effective in forming NO 2 as the release temperature lines up with the maximum NO conversion temperature but traps less C 12 than the sequential configurations. The addition of C 3 H 6 in the feed on the dual-layer catalyst leads to further delay in the NO x desorption as well as increased NO and C 12 conversion at high temperatures. Here, the overall findings provide guidance in the optimizing LHCNT configuration for realistic feeds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain-Induced Trapping of Indirect Excitons in MoSe 2 /WSe 2 Heterostructures

Understanding and control of excitons in transition metal dichalcogenide (TMD) materials are essential for the exploration of the rich many-body physics in TMDs and their applications in photonic and optoelectronic devices. Local strain modulation has been utilized as an effective approach for creating potential traps and localizing intralayer excitons in TMD monolayers. Here, we investigate the effect of strains on indirect excitons in TMD heterostructures. The emergence of narrow spectral peaks from the strained sites together with their drastically reduced lifetimes indicates the formation of potential traps in the heterostructures and the trapping of indirect excitons in them. The absence of photon-antibunching from these trapped indirect excitons further reveals their weak localization in the potential traps. Here, our study indicates that, compared to the case of intralayer excitons, narrower potential traps are required for obtaining highly localized indirect excitons due to their unique properties. These findings have important implications for creating long-wavelength quantum emitters in TMD heterostructures and the exploration of indirect exciton condensation and motion in TMDs.

36 MATERIALS SCIENCE↗

Performance of 3 cm 3 ion trap vacuum package sealed for 10 years

Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10 -13 $τ$ -1/2 integrating down to 1×10 -14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hybrid MEMS-CMOS ion traps for NISQ computing

Surging interest in engineering quantum computers has stimulated significant and focused research on technologies needed to make them manufacturable and scalable. In the ion trap realm this has led to a transition from bulk three-dimensional macro-scale traps to chip-based ion traps and included important demonstrations of passive and active electronics, waveguides, detectors, and other integrated components. At the same time as these technologies are being developed the system sizes are demanding more ions to run noisy intermediate scale quantum (NISQ) algorithms, growing from around ten ions today to potentially a hundred or more in the near future. To realize the size and features needed for this growth, the geometric and material design space of microfabricated ion traps must expand. In this paper we describe present limitations and the approaches needed to overcome them, including how geometric complexity drives the number of metal levels, why routing congestion affects the size and location of shunting capacitors, and how RF power dissipation can limit the size of the trap array. Finally, we also give recommendations for future research needed to accommodate the demands of NISQ scale ion traps that are integrated with additional technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomaly Detection in Liquid Sodium Cold Trap Operation with Multisensory Data Fusion Using Long Short-Term Memory Autoencoder

Sodium-cooled fast reactors (SFR), which use high temperature fluid near ambient pressure as coolant, are one of the most promising types of GEN IV reactors. One of the unique challenges of SFR operation is purification of high temperature liquid sodium with a cold trap to prevent corrosion and obstructing small orifices. We have developed a deep learning long short-term memory (LSTM) autoencoder for continuous monitoring of a cold trap and detection of operational anomaly. Transient data were obtained from the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The cold trap purification at METL is monitored with 31 variables, which are sensors measuring fluid temperatures, pressures and flow rates, and controller signals. Loss-of-coolant type anomaly in the cold trap operation was generated by temporarily choking one of the blowers, which resulted in temperature and flow rate spikes. The input layer of the autoencoder consisted of all the variables involved in monitoring the cold trap. The LSTM autoencoder was trained on the data corresponding to cold trap startup and normal operation regime, with the loss function calculated as the mean absolute error (MAE). The loss during training was determined to follow log-normal density distribution. During monitoring, we investigated a performance of the LSTM autoencoder for different loss threshold values, set at a progressively increasing number of standard deviations from the mean. The anomaly signal in the data was gradually attenuated, while preserving the noise of the original time series, so that the signal-to-noise ratio (SNR) averaged across all sensors decreased below unity. Results demonstrate detection of anomalies with sensor-averaged SNR < 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗