Search NASA⌕ Search

SEARCH · Search NASA

Results for “ultraviolet fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Non-Radiative Shocks in the Cygnus Loop: H2 in HH2 Fluorescence or Collisions?

Far Ultraviolet Spectroscopic Explorer (FUSE) observations at four positions across a faint H-alpha filament in the northern Cygnus Loop were carried out successfully. The O(VI) profiles were measured in the four spectra, and we are in the process of fitting them. We have constructed models for a rippled sheet of emission seen almost edge-on based on non-radiative shock wave models for the time-dependent ionization state of the gas behind the shock. The function that describes the rippled sheet geometry predicts the line-of sight velocity component, and we add thermal broadening for various assumed values of ion-ion and ion-electron equilibration. We then compute the radiative transfer in each of the O(VI) lines along the line of sight. Finally, we multiply by the transmission of the ISM using average O(VI) column densities. So far, it appears that partial thermal equilibration is required. Neither full equilibration nor total lack of equilibration seems to provide a workable model. The HH2 observations have not yet been obtained. FUSE has many targets in this region of the sky. We are hoping to get the observations in the spring if FUSE pointing stability allows.

Raymond, John C.↗

Waveform-dependent air fluorescence from neutral and ionic nitrogen molecules

Laser-induced air fluorescence in the ultraviolet regime is primarily attributed to transitions between the C and B states in excited neutral N 2 molecules and between the B and X states in N$^+_2$ ions. However, the mechanism underlying the former remains contentious, as direct population to the C state by light fields is forbidden by electron spin constraints. In this work, we investigate the mechanism of air fluorescence from excited neutral N 2 molecules by carrier-envelope phase–stabilized sub–4 femtosecond pulses. Our results show that fluorescence from N$^+_2$ ions reaches a maximum with cosine-like pulses, while fluorescence from excited neutral N 2 molecules peaks with sine-like pulses. In addition, by scanning the chirp of the driving pulse, we find that ionic fluorescence is maximized with chirp-free pulses, whereas neutral fluorescence favors negatively chirped pulses. These observations, supported by classical trajectory Monte Carlo simulations, support the mechanism of intersystem crossing from excited spin-singlet states, which are populated via recollision-induced strong-field excitation.

Science & Technology - Other Topics↗

Lignin-based carbon quantum dots with high fluorescence performance prepared by supercritical catalysis and solvothermal treatment for tumor-targeted labeling

The poor fluorescence performance of lignin-based carbon quantum dots (L-CQDs) prepared using the bottom-up method has hindered their development. Here, in this study, a two-step strategy was proposed to efficiently enhance the fluorescence properties of L-CQDs. Lignin was first cracked using an ethanol supercritical/noble metal catalyst; then, the L-CQDs were prepared with the cracked lignin fragments as carbon precursors without adding any modified reagents. Compared with the OL-CQDs prepared by the traditional one-pot hydrothermal method, the L-CQDs-1 prepared from CL-1 containing much low molecular weight compounds, and have photoluminescence (increased from 63 to 975) and excellent up-conversion photoluminescence (enhanced by 16.3 to 963), which significantly enhanced by about 15 times and 60 times, respectively. They can emit bright blue fluorescence under both ultraviolet and near-infrared light irradiation owing to a large amount of surface defects caused by the rich compound composition. When L-CQDs-1 were combined with, and quenched by folic acid (FA), the prepared FA@L-CQDs-1 show the ability to target and label tumor cells. This study opens new avenues for the preparation of L-CQDs with high fluorescence performance using lignocellulosic material without heteroatom additives.

59 BASIC BIOLOGICAL SCIENCES↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

Penetrant-Indication-Measuring Compass

Modified drafting compass well suited to measurement of length of crack or width of area stained by penetrant-dye-inspection method. Equipped with any of variety of standard curved or straight pointed tips. Modification consists in coating tips with dye that fluoresces light pink under same ultraviolet inspection light causing penetrant dye to fluoresce yellow green. Used in locations inaccessible to conventional fluorescent comparator. Eliminates errors of optical distortion in comparator, also eliminates errors of interpolation.

Schaefer, Lloyd↗

Identification of the emission features near 3.5 microns in the pre main sequence star HD 97048

The spectrum of HD97048 was measured with a resolving power of 450 between 3.37 and 3.64 microns. The prominent feature near 3.5 microns is well resolved, with a peak at 3.53 microns and a wing extending to a shorter wavelength. The weaker feature near 3.4 microns is found to peak at 3.43 microns, in contrast to the 3.40 micron feature seen in other astronomical objects. The observed spectrum strongly resembles laboratory spectra of mixtures of monomeric and dimeric formaldehyde embedded in low temperature solids. Of various possible excitation mechanisms, ultraviolet pumped infrared fluorescence of formaldehyde in interstellar grains provides the best explanation for the observed spectrum of HD 97048.

Baas, F.↗

A survey of simulation and diagnostic techniques for hypersonic nonequilibrium flows

The possible means of simulating nonequilibrium reacting flows in hypersonic environments, and the required diagnostic techniques, are surveyed in two categories: bulk flow behavior and determination of chemical rate parameters. Flow visualization of shock shapes for validation of computational-fluid dynamic calculations is proposed. The facilities and the operating conditions necessary to produce the required nonequilibrium conditions, the suitable optical techniques, and their sensitivity requirements, are surveyed. Shock-tubes, shock-tunnels, and ballistic ranges in a wide range of sizes and strengths are found to be useful for this purpose, but severe sensitivity requirements are indicated for the optical instruments, which can be met only by using highly-collimated laser sources. Likewise, for the determination of chemical parameters, this paper summarizes the quantities that need to be determined, required facilities and their operating conditions, and the suitable diagnostic techniques and their performance requirements. Shock tubes of various strengths are found to be useful for this purpose. Vacuum ultraviolet absorption and fluorescence spectroscopy and coherent anti-Stokes Raman spectroscopy are found to be the techniques best suited for the measurements of the chemical data.

Sharma, Surendra P.↗

FT-IR spectroscopic studies of polycyclic aromatic hydrocarbons

Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared absorption coefficients instead of those at the temperature of interest because of the latter's unavailability. The present studies are designed to address the differences between the calculated and experimental thermal emission spectra and to provide information which will be useful in future ultraviolet induced infrared fluorescence studies. The emission spectra have been obtained for temperatures up to 825K using an emission cell designed to mount against an external port of an FT-IR spectrometer. These spectra provide information concerning relative band intensities and peak positions which is unavailable from previous calculations.

Salisbury, D. W.↗

Use of UV Sources for Detection and Identification of Explosives

Measurement of Raman and native fluorescence emission using ultraviolet (UV) sources (<400 nm) on targeted materials is suitable for both sensitive detection and accurate identification of explosive materials. When the UV emission data are analyzed using a combination of Principal Component Analysis (PCA) and cluster analysis, chemicals and biological samples can be differentiated based on the geometric arrangement of molecules, the number of repeating aromatic rings, associated functional groups (nitrogen, sulfur, hydroxyl, and methyl), microbial life cycles (spores vs. vegetative cells), and the number of conjugated bonds. Explosive materials can be separated from one another as well as from a range of possible background materials, which includes microbes, car doors, motor oil, and fingerprints on car doors, etc. Many explosives are comprised of similar atomic constituents found in potential background samples such as fingerprint oils/skin, motor oil, and soil. This technique is sensitive to chemical bonds between the elements that lead to the discriminating separability between backgrounds and explosive materials.

Hug, William↗

Mars 2020 Rover SHERLOC Calibration Target

The Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals (SHERLOC) instrument is a deep ultraviolet (UV) Raman Fluorescence instrument selected as part of the Mars 2020 rover instrument suite. SHERLOC will be mounted on the rover arm and its primary role is to identify carbonaceous species in martian samples. The SHERLOC instrument requires a calibration target which is being designed and fabricated at JSC as part of our continued science participation in Mars robotic missions. The SHERLOC calibration target will address a wide range of NASA goals to include basic science of interest to both the Science Mission Directorate and Human Exploration and Operations Mission Directorate.

Graff, Trevor↗

Characterization of dehydration-induced luminescence of kaolinite

The dehydration-induced luminescence of a colloidal kaolinite is investigated experimentally, with particular attention given to the effect of various treatments on the luminescence characteristics. It is found that the total photon count of the emitted light is linearly related to the film thickness up to a thickness of 30 microns; mechanical stress in the form of grinding increases the photon output and produces extensive changes in the emission kinetics. A direct check of the emission wavelength dependence (by using color filters) indicates that roughly 75 percent of the emission occurs in the wavelength range below 410 nm. It is also found that incorporation of fluorescent molecules into the kaolinite paste increases the photon output and may indicate the transfer of ultraviolet photons to the fluorescent probe.

Lahav, N.↗

Mars Immunoassay Life Detection Instrument (MILDI)

The direct detection of organic biomarkers for living or fossil microbes on Mars by an in situ instrument is a worthy goal for future lander missions. We have proposed an instrument based on immunological reactions to specific antibodies to cause activation of fluorescent stains. Antibodies are raised or acquired to a variety of general and specific substances that might be in Mars soil. These antibodies are then combined with various fluorescent stains and applied to small numbered spots on a small (two to three centimeters) test plate where they become firmly attached after drying. On Mars, a sample of soil from a trench or drill core is extracted with water and/or an organic solvent that is then applied to the test plate. Any substance, which has an antibody on the test plate, will react with its antibody and activate its fluorescent stain. A small ultraviolet light source will illuminate the test plate, which is observed with a small CCD camera. The numbered spots that fluoresce indicate the presence of the tested-for substance, and the intensity indicates relative amounts. The entire instrument can be quite small and light, on the order of ten cm in each dimension. A possible choice for light source may be small UV lasers at several wavelengths. Up to 1000 different sample spots can be placed on a plate 3 cm on a side, but a more practical number might be 100. Each antibody can have a redundant position for independent verification of reaction. Some of the wells or spots can contain simply standard fluorescent stains used to detect live cells, dead cells, DNA, etc. These the stains in these spots may be directly activated; no antibodies are necessary.

McKay, David↗

Fluorescence Imaging Reveals Surface Contamination

In technique to detect surface contamination, object inspected illuminated by ultraviolet light to make contaminants fluoresce; low-light-level video camera views fluorescence. Image-processing techniques quantify distribution of contaminants. If fluorescence of material expected to contaminate surface is not intense, tagged with low concentration of dye.

Schirato, Richard↗

Fluorescence imaging to quantify crop residue cover

Crop residues, the portion of the crop left in the field after harvest, can be an important management factor in controlling soil erosion. Methods to quantify residue cover are needed that are rapid, accurate, and objective. Scenes with known amounts of crop residue were illuminated with long wave ultraviolet (UV) radiation and fluorescence images were recorded with an intensified video camera fitted with a 453 to 488 nm band pass filter. A light colored soil and a dark colored soil were used as background for the weathered soybean stems. Residue cover was determined by counting the proportion of the pixels in the image with fluorescence values greater than a threshold. Soil pixels had the lowest gray levels in the images. The values of the soybean residue pixels spanned nearly the full range of the 8-bit video data. Classification accuracies typically were within 3(absolute units) of measured cover values. Video imaging can provide an intuitive understanding of the fraction of the soil covered by residue.

Daughtry, C. S. T.↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filter Enhances Fluorescent-Penetrant-Inspecting Borescope

Slip-on eyepiece for commercial ultraviolet-light borescope reduces both amount of short-wave ultraviolet light that reaches viewer's eye and apparent intensity of unwanted reflections of white light from surfaces undergoing inspection. Fits on stock eyepiece of borescope, which illuminates surface inspected with intense ultraviolet light. Surface, which is treated with fluorescent dye, emits bright-green visible light wherever dye penetrates - in cracks and voids. Eyepiece contains deep-yellow Wratten 15 (G) filter, which attenuates unwanted light strongly but passes yellow-green fluorescence so defects seen clearly.

Molina, Orlando G.↗