Refurbishment of a used in-vacuum undulator from the National Synchrotron Light Source for the National Synchrotron Light Source-II ring

The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring, the transition region was redesigned. The control system was also updated to NSLS-II specifications. As a result, this paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.

36 MATERIALS SCIENCE↗

Design, Construction, and Testing of 0.5-m, 18-mm Period Nb 3 Sn Superconducting Undulator Magnets

We report design and fabrication of a new Nb 3 Sn-based superconducting undulator (SCU) are underway at the Advanced Photon Source (APS) of Argonne National Laboratory in collaboration with Fermilab and Lawrence Berkeley National Laboratory. To develop a robust and reliable fabrication process, the magnet development consists of several steps. First, magnetic and mechanical simulations were performed to optimize the magnet design; then, the design matured further by fabricating and testing a series of very short prototypes, ~8 cm long with a period length of 18 mm. These short prototype studies were previously reported. Second, the design was scaled to an intermediate length of ~0.5 m. These two steps led to the final design of ~1.1–m-long magnets, which are currently being fabricated. The quench behavior of each 0.5-m-long undulator magnet, as well as undulator assemblies from these magnets, was studied. The first SCU magnet assembly did not meet the design specifications due to the breakdown of the insulation. With an improved design and fabrication process based on lessons learned, the second SCU assembly achieved the design undulator field of 1.2 T. The design was further optimized, and the third set of magnets was fabricated and successfully tested.

43 PARTICLE ACCELERATORS↗

Delta undulator model: Magnetic field and beam test results

A novel type of in-vacuum Elliptical Polarization Undulator (EPU) magnet optimized for linac beam (Delta undulator) was developed at the Laboratory for Elementary-Particle Physics (LEPP) at Cornell University as part of insertion device development for the future Cornell 5 GeV Energy Recovery Source of coherent hard X-rays [1,7]. To evaluate mechanical, vacuum and magnetic properties of the magnet, a short 30 cm model with a 5 mm diameter round gap and a 2.4 cm period was built and tested in LEPP. The beam test of the Delta undulator model was conducted at Accelerator Test Facility (ATF) in BNL with {approx}60 MeV linac beam. The beam testing results confirmed basic properties of the undulator magnet obtained through the magnetic field measurement. In the paper we describe the magnet design, techniques and setups used for the magnetic field measurement and the beam testing results.

43 PARTICLE ACCELERATORS↗

Generation of X-Ray Radiation in Free-Electron Lasers with Two-Frequency Undulators

The possibility of creating an x-ray laser with a two-frequency undulator with the help of the phenomenological model of a single-pass free-electron laser (FEL) that takes into account the beam characteristics and the undulator field is studied. The model is used to analyze the FEL dynamics, and the simulation results are compared with the experimental data. The advantages of using a two-frequency undulator in the single-pass FEL and the possibility of generating powerful x-ray radiation in it are demonstrated. The evolution of power of higher-harmonic generation in the FEL and the bunching coefficient at wavelengths of these harmonics are studied. The possibility of their further amplification until saturation in a cascade FEL matched to higher harmonics of the two-frequency undulator is demonstrated.

43 PARTICLE ACCELERATORS↗

Cryogenic Permanent Magnet Undulators

For an in-vacuum undulator operated at small gaps the permanent magnet material needs to be highly resistant to possible electron beam exposure. At room temperature, one generally uses Sm{sub 2}Co{sub 17} or high coercivity NdFeB magnets at the expense of a limited field performance. In a cryogenic permanent magnet undulator (CPMU), at a temperature of around 150 K, any NdFeB grade reveals a coercivity large enough to be radiation resistant. In particular, very high remanence NdFeB material can be used to build undulators with enhanced field and X-ray brilliance at high photon energy provided that the pre-baking of the undulator above 100 deg. C can be eliminated. The ESRF has developed a full scale 2 m long CPMU with a period of 18 mm. This prototype has been in operation on the ID6 test beamline since January 2008. A significant effort was put into the characterization of NdFeB material at low temperature, the development of dedicated magnetic measurement systems and cooling methods. The measured heat budget with beam is found to be larger than expected without compromising the smooth operation of the device. Leading on from this first experience, new CPMUs are currently being considered for the upgrade of the ESRF.

43 PARTICLE ACCELERATORS↗

Progress on the superconducting undulator for ANKA and on the instrumentation for R and D

Superconducting undulators show a larger magnetic field strength for the same gap and period length, as compared to permanent magnet devices, which allows to generate X-ray beams of higher brilliance and with harder spectrum. The worldwide first short period length superconducting undulator is in operation since 2005 at the synchrotron light source ANKA in Karlsruhe [1]. To further drive the development in this field a research and development program is being carried out. In this contribution we report on the last progress of the construction of a 1.5 m long superconducting undulator with a period length of 15 mm, planned to be installed in ANKA beginning 2010 to be the light source of the new beamline NANO for high resolution X-ray scattering. The key specifications of the system are an undulator parameter K higher than 2 (with a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. Cryocoolers will keep the coils at 4.2 K for a beam heat load of 4 W. The ongoing R and D includes improvements in understanding of the magnetic field properties and of the beam heat load mechanisms. The tools and instruments under development to fulfill these tasks are also discussed.

43 PARTICLE ACCELERATORS↗

A Far-infrared Undulator for Coherent Synchrotron Radiation and Free Electron Laser at Tohoku University

In order to develop an intense far-infrared radiation source, a high quality electron beam has been studied at Tohoku University, Sendai. The bunch length of the beam expected is very much shorter than terahertz (THz) wavelength, so that coherent spontaneous emission of synchrotron radiation will be a promising high brilliant far-infrared source. An undulator consisting of permanent magnets has been designed in which optional free electron laser (FEL) will be operated in free space mode. Consequently the minimum gap of the undulator is decided to be 54 mm for 0.36 mm radiation to avoid diffraction loss, and then the period length of 10 cm is employed. The undulator may cover a wavelength range from 0.18 to 0.36 mm with the beam energy of 17 MeV. Property of coherent THz radiation from the undulator and possibility of novel pre-bunched THz FEL is discussed.

43 PARTICLE ACCELERATORS↗

Proposal of a Bulk HTSC Staggered Array Undulator

We proposed a new type of undulator based on bulk high-T{sub c} superconductors (HTSC) which consists of a single solenoid and a stacked array of bulk HTSC. The main advantage of this configuration is that a mechanical structure is not required to produce and control the undulator field. In order to perform a proof of principle experiment, we have developed a prototype of bulk HTSC staggered array undulator using 11 pairs of DyBaCuO bulk superconductors and a normal conducting solenoid. Experimental results obtained by using the prototype undulator and numerical results obtained by a loop current model based on the Bean mode for a type-II superconductor were compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress on a Superconducting Planar Undulator in the UK

Superconducting (SC) undulators can potentially reach a higher field, for short period devices, than permanent magnet devices. The latest design work on a proposed superconducting planar undulator being designed in the UK by the STFC is presented. The initial layout of the undulator, including superconducting fill factor and the cryogenic system is presented. Calculations of the wakefield heating effects due to different vacuum vessels and electron beam configurations are also presented. Another important issue for superconducting planar undulators is the effect of engineering tolerances of the pole pieces: the computer simulated effects, for different size pole errors, on the electron beam trajectory and phase error through the device are also shown.

43 PARTICLE ACCELERATORS↗

Electron dynamics and transverse-kick elimination in a high-field short-period helical microwave undulator

Single electron dynamics for a circular polarized standing wave (CPSW) undulator synthesized from a corrugated cavity operating with a very low-loss HE{sub 11} mode are analyzed. The mechanism of the transverse drift of the CPSW undulator and its elimination are researched, and the tapered-field ends are found effectively to suppress the kick. A prototype of the CPSW undulator with the characters of short undulating-period 1.4 cm, high field K {approx} 1, large aperture {approx} 5 cm, and variable polarization is designed and modeled, whose 3-dimensional electromagnetic fields are used to research the suppression of the transverse kick.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practical method using superposition of individual magnetic fields for initial arrangement of undulator magnets

We have developed a practical method for determining an excellent initial arrangement of magnetic arrays for a pure-magnet Halbach-type undulator. In this method, the longitudinal magnetic field distribution of each magnet is measured using a moving Hall probe system along the beam axis with a high positional resolution. The initial arrangement of magnetic arrays is optimized and selected by analyzing the superposition of all distribution data in order to achieve adequate spectral quality for the undulator. We applied this method to two elliptically polarizing undulators (EPUs), called U#16-2 and U#02-2, at the Photon Factory storage ring (PF ring) in the High Energy Accelerator Research Organization (KEK). The measured field distribution of the undulator was demonstrated to be excellent for the initial arrangement of the magnet array, and this method saved a great deal of effort in adjusting the magnetic fields of EPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Analysis of a 27.5 mm Period Undulator for the MBA Lattice

The magnetic design of a 27.5 mm period undulator was performed for the APS MBA Lattice. One purpose of the magnetic design was to decrease the magnetic force in order to operate the undulator successfully at a smaller gap compared to the existing 27 mm undulator at the APS. As a result, the magnetic force is decreased by about 18% at a gap of 11 mm and the total volume of the magnet and the pole is decreased by approximately 22% with the new model. The calculated effective field with the new model was 172 G higher than the existing 27-mm period undulator with a gap of 11 mm. The calculated field roll-off with the new optimized model is within the requirements of the MBA, in the range of ± 5 mm.

Abliz, M.↗

Design of a magnetic circuit for a cryogenic undulator in Taiwan photon source

The plan for beamlines in Phase II at Taiwan Photon Source is to construct two new BioSAXS and nano-ARPES beamlines. A highly brilliant light source can be produced with a cryogenic undulator, and many synchrotron facilities have been developed and operated with these in their storage rings. The development of a cryogenic undulator became a target for a light source in TPS phase II. A cryogenic undulator with period of length 15 mm will be made in a hybrid magnetic structure, and use PrFeB permanent-magnet materials. A maximum magnetic field 1.31 T is estimated at gap 4 mm and temperature about 100 K. The spectral performance of a TPS cryogenic undulator is presented in this paper.

43 PARTICLE ACCELERATORS↗

Refurbishment of radiation-damaged undulators

Partial radiation damage has been observed over the previous five years of operation for a few of the PETRA III permanent magnet undulators at DESY. The degradation of the affected devices has been observed by a change in the energy tuning curves and the spectral properties of the undulator harmonics, and also by direct measurements of the peak field distribution of the magnet structure in the storage ring tunnel [1]. During the recent shutdown of the machine, two undulators were removed from the tunnel for repair. One of the devices (U29) has been retuned after flipping of all magnets of the hybrid structure. In addition to this temporary repair, one further magnet structure (U23) has been completely disassembled and refurbished by application of a rare earth diffusion process and a coating to the permanent magnets. We will report on the details of the refurbishment of these undulators which were both fully brought back to specifications and are meanwhile back in operation.

43 PARTICLE ACCELERATORS↗

High-temperature superconducting undulator magnets

Here, this paper presents test results on a prototype superconducting undulator magnet fabricated using 15% Zr-doped rare-earth barium copper oxide high temperature superconducting (HTS) tapes. On an 11-pole magnet we demonstrate an engineering current density, J e , of more than 2.1 kA mm -2 at 4.2 K, a value that is 40% higher than reached in comparable devices wound with NbTi-wire, which is used in all currently operating superconducting undulators. A novel winding scheme enabling the continuous winding of tape-shaped conductors into the intricate undulator magnets as well as a partial interlayer insulation procedure were essential in reaching this advance in performance. Currently, there are rapid advances in the performance of HTS; therefore, achieving even higher current densities in an undulator structure or/and operating it at temperatures higher than 4.2 K will be possible, which would substantially simplify the cryogenic design and reduce overall costs.

36 MATERIALS SCIENCE↗

Development of a Superconducting Adaptive Gap Undulator Prototype for NSLS-II

The photon flux and brightness of synchrotron radiation, crucial parameters for any light source, vary significantly depending on the type of source employed. Among the 23 Insertion Device (ID) sources at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL), the 12-year-old 3m-long In-Vacuum Undulator (IVU20) stands out for its superior performance, although it no longer represents the cutting edge of technology. Recently, there has been a shift in focus towards developing next-generation sources, particularly Superconducting Undulators (SCUs), characterized by smaller gaps, shorter periods, and maximum lengths. However, despite ongoing research and development efforts, SCUs have yet to surpass their predecessors, the Cryogenic Permanent Magnet Undulators (CPMUs), in terms of performance. This is largely attributed to the limitations posed by traditional superconducting wire, as well as challenges in the design of the magnetic structure and vacuum chamber. In this paper, we aim to overcome such limitations through the development of a unique prototype Superconducting Adaptive Gap Undulator (SC-AGU) magnet core and vacuum chamber design. This paper will outline a novel technical approach aimed at constructing a compact prototype magnet array utilizing state-of-the-art superconducting wire technology. This approach provides a more efficient magnetic structure, allowing for enhanced magnetic field strength and stability.

36 MATERIALS SCIENCE↗

Extreme radiation emission regime for electron beams in strong focusing ion channels and undulators

A fundamental comparison between a magnetic undulator and an ion channel, or betatron, radiation from relativistic electrons is presented. While conventional theories nominally range from the undulator (𝐾 <1) to the wiggler (𝐾 >1) regime, they are only applicable for sufficiently large Lorentz factors (𝛾 0 ≫𝐾). They therefore do not account for high 𝐾/𝛾 0 cases, for which we show that particle trajectories and radiation characteristics strongly deviate from the linear predictions in both magnetic undulators and ion channels. This problem arises from the fundamental differences between a magnetostatically and electrostatically induced oscillation. A reformulation of both the ion channel betatron wavelength and amplitude, as well as the same parameters in a magnetic undulator, permits us to compare cases with equivalent oscillation period and amplitude in the two different scenarios. The notable differences in spectral features of the two radiation mechanisms can then be addressed via numerical simulations of single particle as well as full beam dynamics. Additionally, we identify and quantify a novel transverse orbit precession effect in ion channels for particles with initial angular momentum relative to the device axis. This effect, which is significant in cases of strong transverse kinetic energy oscillations, alters both the radiation divergence and the beam emittance. In this paper, we present this new theoretical framework and compare its results with numerical simulation applied to realizable experimental tests of such radiation sources.

Frazzitta, Andrea [University of Rome “La Sapienza↗

Cryogenic System Preliminary Design for a 0.5m-Long, Conduction-Cooled Nb3Sn Undulator Magnet Prototype

There are several NbTi superconducting undulator (SCU) magnets currently in operation at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The development on Nb3Sn-based superconducting undulator magnets at APS is underway due to the potential to further enhance the performance of the SCUs. Superconducting undulator magnets need to keep temperature gradients minimized in order to retain thermal and operating current margin. We have designed the thermal links for efficient heat conduction using 3D finite element analysis (FEA) simulation in COMSOL Multiphysics software, which was later used for the calculation of the temperature distribution across a 0.5 m long, conduction-cooled, Nb3Sn undulator magnet prototype that includes both conductive heat transfer and radiative heating components. We have modelled the evolution of the thermal properties of the magnet winding as well as other cold parts during cool-down from ambient temperature with the operation of a SHI RDK-415D cryocooler to examine the estimated time that is needed for the cooldown as well as the baseline temperature we could achieve. A key result was that a maximum coil delta T = 0.11 K along the designed thermal links and a temperature range of 3.42 K-3.53 K for the winding were predicted at steady state. A pair of G10 support rods for carrying the magnet as well as a pair of current leads made of metals were also designed and optimized for the testing system, targeting for an operation temperature of 4 K and a coil current of 950 A DC.