At least 91 records · Page 5

Exploiting Multi-Domain Features for Detection of Unclassified Electromagnetic Signals

Deep Learning based classification techniques have shown excellent performance in static environments, where the training and testing samples are drawn from the same distribution. However, real world scenarios often present samples that do not belong to the known set of classes chosen during training. This is quite common for electromagnetic signals, where it is impractical to assume that all possible waveforms are known a-priori, specially in scenarios like warfare. To address this problem, we propose a deep learning based adversarial model where the generator learns to generate waveform features that can deceive the discriminator model as true samples. We introduce domain knowledge of wireless signals by decomposing the signal into a lower dimensional unique feature set, which is used for classifying known versus unknown signals. We further introduce multiple domain representations of the signal to extract features and combine them together to accurately classify new waveforms as an unknown class. Our results show that combined features from multiple domains outperform any single domain representation, especially at low SNR regimes with fewer number of samples to classify.

99 - GENERAL AND MISCELLANEOUS↗

Exploiting Multi-Domain Features for Detection of Unclassified Electromagnetic Signals (Presentation)

Deep Learning based classification techniques have shown excellent performance in static environments, where the training and testing samples are drawn from the same distribution. However, real world scenarios often present samples that do not belong to the known set of classes chosen during training. This is quite common for electromagnetic signals, where it is impractical to assume that all possible waveforms are known a-priori, specially in scenarios like warfare. To address this problem, we propose a deep learning based adversarial model where the generator learns to generate waveform features that can deceive the discriminator model as true samples. We introduce domain knowledge of wireless signals by decomposing the signal into a lower dimensional unique feature set, which is used for classifying known versus unknown signals. We further introduce multiple domain representations of the signal to extract features and combine them together to accurately classify new waveforms as an unknown class. Our results show that combined features from multiple domains outperform any single domain representation, especially at low SNR regimes with fewer number of samples to classify.

99 - GENERAL AND MISCELLANEOUS↗

Semiselective Optoelectronic Sensors for Monitoring Microbes

Sensor systems are under development for use in real-time detection and quantitation of microbes in water without need for sampling. These systems include arrays of optical sensors; miniature, portable electronic data-acquisition circuits; and optoelectronic interfaces between the sensor arrays and data-acquisition circuits. These systems are intended for original use in long-term, inline monitoring of waterborne micro-organisms in water-reclamation systems aboard future spacecraft. They could also be adapted to similar terrestrial uses with respect to municipal water supplies, stored drinking water, and swimming water; for detecting low-level biological contamination in biotechnological, semiconductor, and pharmaceutical process streams; and in verifying the safety of foods and beverages. In addition, they could be adapted to monitoring of airborne microbes and of surfaces (e.g., to detect and/or quantitate biofilms). The designs of the sensors in these systems are based partly on those of sensors developed previously for monitoring airborne biological materials. The designs exploit molecular- recognition and fluorescence-spectroscopy techniques, such that in the presence of micro-organisms of interest, fluorescence signals change and the changes can be measured. These systems are characterized as semiselective because they respond to classes of micro-organisms and can be used to discriminate among the classes. This semiselectivity is a major aspect of the design: It is important to distinguish between (1) the principle of detection and quantitation of classes of micro-organisms by use of these sensors and (2) the principle of detection and quantitation of individual microbiological species by means of prior immuno-diagnostic and/or molecular-biology techniques. Detection of classes (in contradistinction to species) is particularly valuable when the exact nature of a contaminant is unknown.

Tabacco, Mary Beth↗

Neural mechanisms of kinesthesia

Our primary interest is in where the signals for position and movement of the limbs originate and how the information is encoded. Humans can independently sense the positions and movements of their limbs in the absence of vision, and their senses are derived from mechanoreceptors located in the limbs. Receptors in muscles, skin and joints are potential sources of position and movement signals, but how (and whether) each of these groups contributes to kinesthesia remains uncertain. Recent evidence indicates that a sense of static-position derives from length receptors in muscle, whereas receptors in the skin, and possibly though not likely the joints, can signal movement of a limb but not its static position. At present, we are examining the consequences of not having a static-position sense at the fingers apart from an inability to detect very slow displacements. Using a more demanding test, we have found no substantial difference in the accuracy of reproducing target positions passively imposed on the MCP joint and the proximal interphalangeal (PIP) joint of the index finger. Our working hypothesis is that subjects normally use movement sense mechanisms to detect displacements, probably because they are faster, but how (or whether) subjects manage to obtain an absolute position reference with only a movement sense available remains unknown and is an issue under investigation.

Clark, Francis J.↗

Threat Agnostic Virulence Assessment of Pathogens

Virulence assessment of new, emerging, and engineered pathogens is critical to mounting an appropriate response to a biothreat agent. The capacity of the pathogen to colonize human and harm tissues must be characterized to understand pathogenicity pathways and optimize diagnosis and treatment of resulting disease. Respiratory pathogens are of interest because they can have high transmissibility rates, as observed with the SARS-CoV-2 virus, the causative agent of Covid-19. Current technologies are insufficient to assess threats due to their reliance on systems with only one cell type and on sequencing the pathogen. However, it is known that sequence is not an accurate predictor of function, and sequencing can be unreliable for newly emerged or engineered pathogens. An ideal system would consist of relevant epithelial cell types and an assay sensitive enough to detect changes in host responses that do not rely on DNA sequencing. We chose a system consisting of host lung epithelial cells that can be used to assess the virulence of unknown respiratory pathogens. We interrogated pathogens using this model and assess features of pathogenicity. Our objective is to leverage PNNLs strengths in tissue engineering and proteomics capabilities to build a multiple reaction monitoring (MRM) or parallel reaction monitoring (PRM) liquid chromatography-tandem mass spectrometry assay for human host cell proteins whose abundance is influenced by infection. These responses can were then assessed for relative virulence using pathogen agnostic signatures. When confronted with a pathogen, cells activate dedicated signaling pathways, typically through phosphorylation of regulatory proteins and downstream activation of host cell networks.

59 BASIC BIOLOGICAL SCIENCES↗

A search for Heavy Neutral Leptons with masses up to 150 MeV and studies on scintillation light detection in SBND

Introduction Neutrino physics is one of today’s most promising fields in particle physics. The discovery of neutrino oscillations is an evidence of their mass not being null. However, the Standard Model of elementary particles (SM) does not contain a mechanism that generates them, so we have to search beyond the SM to find answers. Other unknowns remain open, such as the amount of CP symmetry violated in the lepton sector that could help explain the differences between matter and antimatter that formed the present universe. Nor is it understood why these particles are so light, more than six orders of magnitude below the next fermion, the electron. A possible explanation is the existence of heavier neutrino mass states usually referred as heavy neutral leptons (HNLs). One of the most advanced technologies for detecting neutrino interactions is the liquid argon time projection chamber (LArTPC). LArTPC detectors form a 3D image of the ionized electrons in the interaction, producing a detailed description of each neutrino event. Argon is also a prolific scintillator (40k photons/MeV) with light signals indicating the interaction time. The Short-Baseline Near Detector (SBND), a 112-active mass LArTPC at Fermilab, will measure millions of neutrino interactions from the Booster Neutrino Beam (BNB). As the near (L=110 m) detector of the Short-Baseline neutrino program, SBND will search for a fourth light neutrino (∼ eV) in the coming years. This hypothesis could explain the anomalous data observed in the LSND and MiniBooNE experiments.

Álvarez Garrote, Rodrigo [Madrid U.] (ORCID:000000↗

Single Bimodular Sensor for Differentiated Detection of Multiple Oxidative Gases

Semiconductive metal-oxide sensors suffer from cross-sensitivities under mixed chemical condition, specifically upon mixture of multiple oxidative or reductive gases. Herein, a single bimodular sensor is demonstrated for smart differentiation of multiple oxidative analytes by relating the resistance-metric mode to impedance-metric mode. The sensor construct based on ZnO nanorods readily outputs three response datasets upon exposure of oxidative-gas mixture including O 2 , SO 2 , and NO 2 , the resistance, real part impedance, and imaginary part impedance. The differentiative and correlated nature between these response signals allows such a single sensor platform to differentiate these oxidative gases accurately and robustly. Linear and non-linear decision boundaries are established over a large gas-concentration range from 2 ppm to 3% through a combination of principal component analysis and artificial neural network training. A facile user interface is demonstrated for recognition and measurement of unknown gas analytes, with the error of the predicted analyte-concentration as low as 2%.

36 MATERIALS SCIENCE↗

Utilizing the MODIS 1.38 micrometer Channel for Cirrus Cloud Optical Thickness Retrievals: Algorithm and Retrieval Uncertainties

The cloud products from the Moderate Resolution Imaging Spectroradiometers (MODIS) on Terra and Aqua have been widely used within the atmospheric research community. The retrieval algorithms, however, oftentimes have difficulty detecting and retrieving thin cirrus, due to sensitivities to surface reflectance. Conversely, the 1.38 micron channel, located within a strong water vapor absorption band, is quite useful for detecting thin cirrus clouds since the signal from the surface can be blocked or substantially attenuated by the absorption of atmospheric water vapor below cirrus. This channel, however, suffers from nonnegligible attenuation due to the water vapor located above and within the cloud layer. Here we provide details of a new technique pairing the 1.38 micron and 1.24 micron channels to estimate the above/in-cloud water vapor attenuation and to subsequently retrieve thin cirrus optical thickness (tau) from attenuation-corrected 1.38 p.m reflectance measurements. In selected oceanic cases, this approach is found to increase cirrus retrievals by up to 38% over MOD06. For these cases, baseline 1.38 micron retrieval uncertainties are estimated to be between 15 and 20% for moderately thick cirrus (tau > 1), with the largest error source being the unknown cloud effective particle radius, which is not retrieved with the described technique. Uncertainties increase to around 90% for the thinnest clouds (tau < 0.5) where instrument and surface uncertainties dominate.

Meyer, Kerry↗

Direct Adaptive Control of Systems with Actuator Failures: State of the Art and Continuing Challenges

In this paper, the problem of controlling systems with failures and faults is introduced, and an overview of recent work on direct adaptive control for compensation of uncertain actuator failures is presented. Actuator failures may be characterized by some unknown system inputs being stuck at some unknown (fixed or varying) values at unknown time instants, that cannot be influenced by the control signals. The key task of adaptive compensation is to design the control signals in such a manner that the remaining actuators can automatically and seamlessly take over for the failed ones, and achieve desired stability and asymptotic tracking. A certain degree of redundancy is necessary to accomplish failure compensation. The objective of adaptive control design is to effectively use the available actuation redundancy to handle failures without the knowledge of the failure patterns, parameters, and time of occurrence. This is a challenging problem because failures introduce large uncertainties in the dynamic structure of the system, in addition to parametric uncertainties and unknown disturbances. The paper addresses some theoretical issues in adaptive actuator failure compensation: actuator failure modeling, redundant actuation requirements, plant-model matching, error system dynamics, adaptation laws, and stability, tracking, and performance analysis. Adaptive control designs can be shown to effectively handle uncertain actuator failures without explicit failure detection. Some open technical challenges and research problems in this important research area are discussed.

Tao, Gang↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lensing without borders – I. A blind comparison of the amplitude of galaxy–galaxy lensing between independent imaging surveys

ABSTRACT Lensing without borders is a cross-survey collaboration created to assess the consistency of galaxy–galaxy lensing signals (ΔΣ) across different data sets and to carry out end-to-end tests of systematic errors. We perform a blind comparison of the amplitude of ΔΣ using lens samples from BOSS and six independent lensing surveys. We find good agreement between empirically estimated and reported systematic errors which agree to better than 2.3σ in four lens bins and three radial ranges. For lenses with zL > 0.43 and considering statistical errors, we detect a 3–4σ correlation between lensing amplitude and survey depth. This correlation could arise from the increasing impact at higher redshift of unrecognized galaxy blends on shear calibration and imperfections in photometric redshift calibration. At zL > 0.54, amplitudes may additionally correlate with foreground stellar density. The amplitude of these trends is within survey-defined systematic error budgets that are designed to include known shear and redshift calibration uncertainty. Using a fully empirical and conservative method, we do not find evidence for large unknown systematics. Systematic errors greater than 15 per cent (25 per cent) ruled out in three lens bins at 68 per cent (95 per cent) confidence at z < 0.54. Differences with respect to predictions based on clustering are observed to be at the 20–30 per cent level. Our results therefore suggest that lensing systematics alone are unlikely to fully explain the ‘lensing is low’ effect at z < 0.54. This analysis demonstrates the power of cross-survey comparisons and provides a promising path for identifying and reducing systematics in future lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Flight-Tested Prototype of BEAM Software

Researchers at JPL have completed a software prototype of BEAM (Beacon-based Exception Analysis for Multi-missions) and successfully tested its operation in flight onboard a NASA research aircraft. BEAM (see NASA Tech Briefs, Vol. 26, No. 9; and Vol. 27, No. 3) is an ISHM (Integrated Systems Health Management) technology that automatically analyzes sensor data and classifies system behavior as either nominal or anomalous, and further characterizes anomalies according to strength, duration, and affected signals. BEAM (see figure) can be used to monitor a wide variety of physical systems and sensor types in real time. In this series of tests, BEAM monitored the engines of a Dryden Flight Research Center F-18 aircraft, and performed onboard, unattended analysis of 26 engine sensors from engine startup to shutdown. The BEAM algorithm can detect anomalies based solely on the sensor data, which includes but is not limited to sensor failure, performance degradation, incorrect operation such as unplanned engine shutdown or flameout in this example, and major system faults. BEAM was tested on an F-18 simulator, static engine tests, and 25 individual flights totaling approximately 60 hours of flight time. During these tests, BEAM successfully identified planned anomalies (in-flight shutdowns of one engine) as well as minor unplanned anomalies (e.g., transient oil- and fuel-pressure drops), with no false alarms or suspected false-negative results for the period tested. BEAM also detected previously unknown behavior in the F- 18 compressor section during several flights. This result, confirmed by direct analysis of the raw data, serves as a significant test of BEAM's capability.

Mackey, Ryan↗

Surface-Enhanced Raman Spectroscopy (SERS) for Venus Atmospheric Characterization and Trace Organics Identification

The chemical composition of Venus’ clouds has attracted considerable attention since the first atmospheric probes entered the planet in the early 1980s. We know from these early studies that cloud aerosols consist of micron and submicron droplets of sulfuric acid (~85%) and water (~15%), but outstanding questions still exist regarding their trace chemical composition, especially the identity of the unknown UV absorber(s) and the possible presence of organic material (Spacek & Benner, 2021). Veritas and DaVinci will launch at the end of the decade to advance our understanding of Venus’ surface and atmosphere, however these missions are not designed to sample and analyze cloud aerosols at trace levels. Raman spectroscopy is an ideal candidate for characterizing aerosols and has a track record in studies of Earth’s atmosphere. Raman provides broad chemical screening of organic and inorganic molecules within seconds, and Raman instrumentation can be miniaturized to meet the stringent size, weight, and power (SWaP) constraints of an atmospheric probe while retaining sensitivity and specificity that allow spectral fingerprinting of compounds and functional groups. Raman alone is insufficient to characterize trace constituents however, as limits of detection are typically in the 10s to 100s of ppm at best for planetary Raman spectrometers. Surface-Enhanced Raman Spectroscopy (SERS), a method that utilizes nanoscale materials interacting with a sample to enhance weak Raman signals by orders of magnitude when probed by a laser, has the potential to drastically improve the sensitivity of a Raman instrument while adding little-to-no SWaP nor complexity to a scientific payload. We aim to de-risk SERS technology for rapid infusion in future planetary science missions by developing custom SERS substrates tailored towards Venus atmospheric exploration. We have developed SERS substrates consisting of nanotextured silver films and tested them on potential Venus-relevant organic compounds, with preliminary results indicating sub-ppm sensitivity. Additionally, we have planned tests to investigate durability, longevity, and other key characteristics that impact SERS substrate performance to prepare SERS technology for flight.

Venus↗

Object and Gas Source Detection with Robotic Platforms in Perceptually-Degraded Environments

In exploration-oriented robotic missions for disaster relief in unknown subterranean environments, it is of prime importance for a human supervisor to rapidly gain situational awareness of salient objects within the environment. In this paper we present an automated object detection pipeline that is adaptable to heterogeneous robots with arbitrary sensor configurations. It has been deployed in time-critical scenarios with multiple collaborative robots in a variety of demanding underground environments. For visually observable objects, detections are made in both the visible and thermal spectra using a state-of-the-art machine learning framework for object detection and classification. Our pipeline can be rapidly adapted to a specific task by using a small, structured dataset to fine-tune a pre-trained convolutional neural network (CNN). Relative localization is separated from the CNN for speed of operation. A robust architecture for localization is used with outlier rejection and a hierarchy of fall-back distance measurement methods. Point-source objects such as gas and WiFi hotspots can also be detected, by tracking signal strength over time and presenting an intuitive visualization on a map. Observations of each object types are presented to the operator in ranked confidence order for final evaluation.

Agha-mohammadi, Ali-akbar↗

In situ detection of ferric reductase activity in the intestinal lumen of an insect

The rise of atmospheric oxygen as a result of photosynthesis in cyanobacteria and chloroplasts has transformed most environmental iron into the ferric state. In contrast, cells within organisms maintain a reducing internal milieu and utilize predominantly ferrous iron. Ferric reductases are enzymes that transfer electrons to ferric ions, either extracellularly or within endocytic vesicles, enabling cellular ferrous iron uptake through Divalent Metal Transporter 1. In mammals, duodenal cytochrome b is a ferric reductase of the intestinal epithelium, but how insects reduce and absorb dietary iron remains unknown. Here we provide indirect evidence of extracellular ferric reductase activity in a small subset of Drosophila melanogaster intestinal epithelial cells, positioned at the neck of the midgut’s anterior region. Dietary-supplemented bathophenanthroline sulphate (BPS) captures locally generated ferrous iron and precipitates into pink granules, whose chemical identity was probed combining in situ X-ray absorption near edge structure and electron paramagnetic resonance spectroscopies. An increased presence of manganese ions upon BPS feeding was also found. Control animals were fed with ferric ammonium citrate, which is accumulated into ferritin iron in distinct intestinal subregions suggesting iron trafficking between different cells inside the animal. Spectroscopic signals from the biological samples were compared to purified Drosophila and horse spleen ferritin and to chemically synthesized BPS-iron and BPS-manganese complexes. The results corroborated the presence of BPS-iron in a newly identified ferric iron reductase region of the intestine, which we propose constitutes the major site of iron absorption in this organism.

EPR↗

Oxidation States of Grim Glasses in EET79001 Based on Vanadium Valence

Gas-rich impact-melt (GRIM) glasses in SNC meteorites are very rich in Martian atmospheric noble gases and sulfur suggesting a possible occurrence of regolith-derived secondary mineral assemblages in these samples. Previously, we have studied two GRIM glasses, 506 and 507, from EET79001 Lith A and Lith B, respectively, for elemental abundances and spatial distribution of sulfur using EMPA (WDS) and FE-SEM (EDS) techniques and for sulfur-speciation using K-edge XANES techniques. These elemental and FE-SEM micro-graph data at several locations in the GRIM glasses from Shergotty (DBS), Zagami 994 and EET79001, Lith B showed that FeO and SO3 are positively correlated (SO3 represents a mixture of sulfide and sulfate). FE-SEM (EDS) study revealed that the sulfur-rich pockets in these glasses contain numerous micron-sized iron-sulfide (Fe-S) globules sequestered throughout the volume. However, in some areas (though less frequently), we detected significant Fe-S-O signals suggesting the occurrence of iron sulfate. These GRIM glasses were studied by K-edge microXANES techniques for sulfur speciation in association with iron in sulfur-rich areas. In both samples, we found the sulfur speciation dominated by sulfide with minor oxidized sulfur mixed in with various proportions. The abundance of oxidized sulfur was greater in 506 than in 507. Based on these results, we hypothesize that sulfur initially existed as sulfate in the glass precursor materials and, on shock-impact melting of the precursor materials producing these glasses, the oxidized sulfur was reduced to predominately sulfide. In order to further test this hypothesis, we have used microXANES to measure the valence states of vanadium in GRIM glasses from Lith A and Lith B to complement and compare with previous analogous measurements on Lith C (note: 506 and 507 contain the largest amounts of martian atmospheric gases but the gas-contents in Lith C measured by are unknown). Vanadium is ideal for addressing this re-dox issue because it has multiple valence states and is a well-studied element. Ferrous-dominated iron valences determined by microXANES on the Lith A and Lith B glasses provide little redox sensitivity. Vanadium valence measurements for impact glass in Lith C at three different locations yielded valence values of 3.1, 3.2 and 3.4 with inferred fO2 values of IW-0.7, IW-0.1 and IW+0.7, respectively. This range of oxygen-fugacity values is understandable because the glasses are shock-molten impact glasses which are heterogeneous in nature. Oxygen fugacity values obtained from the analysis of Fe-Ti oxides and Eu partitioning in pyroxenes from EET79001 Lith A and Lith B (host lithologies) were in the range of IW+0.3 to IW+1.9 suggesting that V in the Lith C impact glass was reduced in the impact process. Here, we examine whether the 506 from Lith A and 507 from Lith B GRIM glasses yield similar or different fO2 values from those of Lith C using the vanadium K-edge microXANES technique.

Sutton, S. R.↗

The origin of broad emission lines in the extragalactic giant H II region NGC 2363

High signal-to-noise long-slit spectra have been obtained of the giant H II region NGC 2363 located in the dwarf SBm galaxy NGC 2366. A discovery of low-intensity broad spectral components (FWHM is approximately equal to 40 A or 2400 km/s) in the bright nebular lines H-alpha, H-beta, and forbidden O III is reported. The broad spectral components are detected over a large spatial extent (not less than 500 pc) centered on the nebula. Several mechanisms for broadening nebular lines are explored: stellar winds, Thomson scattering by hot gas, supernova remnants, and superbubble blowout. All mechanisms have problems. Superbubble blowout, which is the only known mechanism capable of accelerating interstellar gas over such a volume of space, does not appear consistent with the physical properties of the H II region NGC 2363 or with the nature of the host galaxy. It is concluded that the broad nebular lines are probably due to very high velocity gas whose origin is, at present, unknown.

Roy, Jean-Rene↗

Prospects for distinguishing supernova models using a future neutrino signal

The next Galactic core-collapse supernova (SN) should yield a large number of observed neutrinos. Here, using Bayesian techniques, we show that with a SN at a known distance up to 25 kpc, the neutrino events in a water Cherenkov detector similar to Super-Kamiokande (SK) could be used to distinguish between seven one-dimensional neutrino emission models assuming no flavor oscillations or the standard Mikheyev-Smirnov-Wolfenstein effect. Some of these models could still be differentiated with a SN at a known distance of 50 kpc. We also consider just the relative distributions of neutrino energy and arrival time predicted by the models and find that a detector like SK meets the requirement to distinguish between these distributions with a SN at an unknown distance up to $\mathrm{\sim 10 kpc.}$