Development of a Battery-Free Solar Refrigerator

Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.

Ewert, Michael K.↗

Engineered Nanoporous Frameworks for Adsorption Cooling Applications

The energy demand for traditional vapor-compressed technology for space cooling continues to soar year after year due to global warming and the increasing human population’s need to improve living and working conditions. Thus, there is a growing demand for eco-friendly technologies that use sustainable or waste energy resources. Here this review discusses the properties of various refrigerants used for adsorption cooling applications followed by a brief discussion on the thermodynamic cycle. Next, sorbents traditionally used for cooling are reviewed to emphasize the need for advanced capture materials with superior properties to improve refrigerant sorption. The remainder of the review focus on studies using engineered nanoporous frameworks (ENFs) with various refrigerants for adsorption cooling applications. The effects of the various factors that play a role in ENF–refrigerant pair selection, including pore structure/dimension/shape, morphology, open-metal sites, pore chemistry and possible presence of defects, are reviewed. Next, in-depth insights into the sorbent–refrigerant interaction, and pore filling mechanism gained through a combination of characterization techniques and computational modeling are discussed. Finally, we outline the challenges and opportunities related to using ENFs for adsorption cooling applications and provide our views on the future of this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From the Discovery of the Giant Magnetocaloric Effect to the Development of High‐Power‐Density Systems

Caloric cooling and heating promise an efficient and reliable alternative to ubiquitous vapor-compression technology. In 1976, the very first near-room-temperature caloric system is developed, but it took another 20 years for this technology to fully bloom and gain global attention. The discovery of the giant magnetocaloric effect in Gd 5 Si 2 Ge 2 and the advance of the first long-operating magnetic refrigerator, both in 1997, due to the Ames National Laboratory and Astronautics Corporation of America cooperation, are two milestones that sparked ongoing interest in caloric research, which continues to thrive to this day. This review presents a brief history of caloric heat pumping, from the discovery of the magnetocaloric effect to the most recent developments in materials and systems. The contributions of Ames National Laboratory of the U.S. Department of Energy are highlighted, celebrating its 30-year anniversary in caloric research and paying tribute to two outstanding scientists, Vitalij K. Pecharsky and Karl A. Gschneidner, Jr., who inspired the caloric community for decades. The paper concludes with insights into remaining research and development challenges that must be addressed to enable the market transition of caloric technology and its widespread adoption.

caloric materials↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Reduction of liquid hydrogen boiloff: Optimal reliquefaction system design and cost study

The refrigeration cycles investigated are referred to as Joule-Thomson cycles because they depend on the J-T effect to produce the low temperatures. Two basic competitive refrigeration cycles were evaluated. The first vents a portion of cold H2 gas to achieve the required precooling; the second uses LN2 for precooling. Both open loop and closed loop cycles were evaluated as well as combinations of venting to supplement the LN2 precooling. All cycles use a H2 compressor to achieve the desired high pressure (1325 psig). The heat compression was removed by cooling water. The high pressure H2 gas was cooled in counter flow heat exchangers by flowing cold H2 to the compressor. Further cooling was achieved for cycles using LN2 by passing H2 vapors through a LN2 heat exchanger. Finally, the high pressure H2 gas was expanded through a J-T valve where a portion of H2 was liquefied. The low pressure H2 gas flow back through the heat exchangers to the compressor is that portion not liquefied and makes up hydrogen gas from the dewar.

Source record↗

Development of Two-Phase Dense Fluid Expander for Advanced Cryogenic Air Separation and Low-Grade Heat Recovery

Cryogenic air separation represents the state-of-the-art technology to produce oxygen to feed coal gasification units. Given the maturity of this technology, it is difficult to identify opportunities to improve process efficiency and reduce the cost of the oxygen produced. However, Air Products conducted research and a feasibility investigation into the use of a two-phase (liquid-vapor) dense fluid expander (DFE) to improve the overall efficiency of cryogenic air separation. Demonstration of this novel concept was intended to allow two important process improvements: 1) elimination of the need for the DFE discharge to be single phase 2) expansion of the operating region of expanders in ASU service. Expanding the scope of turboexpander application beyond current application limits and traditional device designs would allow an increase in power recovery, and application of refrigeration and power recovery at new locations in process cycles would also enable the implementation of new process concepts. These new process concepts include power recovery from compression waste heat and refrigeration extraction and power recovery by replacing let-down valves with two-phase DFEs. Considering the maturity of cryogenic air separation, these new process options could represent a step change in power reduction and provide significant savings in operating costs. These new concepts would be particularly well-suited to large-scale oxygen production by cryogenic air separation and would enhance the economics of producing oxygen for use in coal gasification processes. Rotoflow, an Air Products business unit, manufactures dense fluid expanders in Pennsylvania for sites around the world. This project was executed in two phases, which are illustrated in Figure 1 below. Phase 1 consisted of a feasibility investigation of multiple applications of two-phase DFEs. In Phase 2, devices were identified, designed, fabricated and tested to explore the feasibility of commercial applications of DFEs operating in two-phase service. Engineering and testing were performed by personnel in Air Products’ Rotoflow business unit, with coordination with other Air Products business units.

01 COAL, LIGNITE, AND PEAT↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safety considerations in the design of Spacelab refrigerator/freezer

A vapor compression refrigerator/freezer has been designed for Spacelab to conduct life sciences experiments. It is equipped with different safety features to eliminate all probable types of failures. The whole Freon loop is enclosed in a second containment so that any leakage of Freon can be contained. The unit is provided with an 'Emergency On' switch to actuate during backup mode which provides the spacecraft power directly to the compressor and the cooling fans while removing the power supply and all normal control elements from the circuit. During this mode, the compressor runs continuously when operating as a freezer (-22 C) and is controlled by a thermostat to cycle when operating as a refrigerator (4 C). It has a push button switch at the front panel to momentarily power the thermometer by a battery to monitor the inside temperature during an emergency. It has a door switch which shuts off the internal cooling fans when the door is opened. All the important critical performance data will be downlinked through a data connector to monitor during mission.

Hye, A.↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Manipulating Pore Topology and Functionality to Promote Fluorocarbon-Based Adsorption Cooling

With the worldwide demand for refrigeration and cooling expected to triple, it is increasingly important to search for alternative energy resources to drive the refrigeration cycles with reduced electricity consumption. Recently, adsorption cooling has gained increased attention since energy reallocation in such systems is based on gas adsorption/desorption, which can be driven by waste/natural heat sources. Eco-friendly sorption-based cooling relies on the cyclic transfer of refrigerant gas from a high to low energy state by the pseudo-compression effect resulting from adsorption and desorption. The driving force for energy transfer relies on heat rather than electricity. The performance of a sorption chiller is primarily influenced by this cyclic sorption behavior, which is characterized as the working capacity of the porous sorbent. Thus increases in this working capacity directly translate to a more compact and efficient cooling system. How-ever, a lack of highly effective sorbent/refrigerant pairs lowers cooling performance, and therefore has limited applicability. To this end, synthetic metal-organic frameworks (MOFs) and covalent organic polymers (COPs) possess higher porosity and greater tunability leading to more substantial potential benefits for adsorption, compared to traditional sorbent materials. Similarly, hydrofluorocarbon refrigerants have more favorable applicability given ease of operation above atmospheric pressures due to suitable saturated vapor pressures and boiling points. For these reasons, our work focuses on an ongoing strategy to promote sorption cooling via improvements in the sorbent/refrigerant pair. Specifically, we target the interaction of hydrofluorocarbon refrigerants with MOF/COP materials at a molecular level by interpreting the host-guest chemistry and the role of framework pore topology. These molecular level differences translate to cooling performance, which is described herein. These strategies include engineering framework porosity (i.e., pore size, pore volume) by using elongated organic linkers and stereochemistry control during synthesis; manipulating the sorb-ate/sorbent interaction by introducing functional moieties or unsaturated metal centers to enhance working capacities in narrow pressure ranges; varying pore topology/morphology to impact adsorption isotherm behavior; and leveraging defective sites within the frameworks to further enhance adsorption capability. Here this atomic level understanding of sorb-ate-sorbent interactions is conducted using various in situ experimental techniques such as synchrotron-based X-ray diffraction, X-ray absorption spectroscopy, in situ Fourier transform infrared spectroscopy, and direct sorption energies determinization with calorimetry. Moreover, the experimentally studied interactions and the corresponding adsorption mechanism are corroborated by computational studies using density functional theory (DFT) and grand canonical Monte Carlo (GCMC) simulations. Using this approach, we envision the capability to engineer designed frameworks with precise molecular control to target refrigerant molecules and thereby enhance the performance of desired working pairs for sorption-based cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemical Ammonia Compression

An electrochemical (EC) compressor is a solid-state compression device. For decades, researchers have been studying EC compressors for applications for a variety of energy systems. As the world transitions away from fossil fuel energy sources, EC compression emerges as a promising technique for energy storage, specifically energy stored in the form of pressurized ammonia. Ammonia is also a commonly used refrigerant. The present studies examine the viability of EC compression for ammonia storage and refrigeration. EC ammonia compression increases the concentration of an ammonia-hydrogen mixture via the input of electrical energy and a series of chemical reactions. A polymer electrolyte membrane separates the low-concentration side from the high-concentration side of the device. On the low-pressure (anode) side hydrogen atoms oxidize and react with ammonia molecules, forming positively charge ammonium ions. The ions traverse the membrane electrolytically. The ammonium ions are reduced and revert back to hydrogen and ammonia upon reaching the high-pressure (cathode). An external circuit provides the current needed to sustain the reactions. In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm2 of active area. We demonstrated the operation of larger cells with 100 cm2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state. We analyzed the effects of pressure and current on the EC compressor performance. We measured the flow rates of gas leaving the compressors and analyzed the composition using gas chromatography. We tested methods of separating ammonia from the effluent vapor, which contained hydrogen and water vapor. We found that back diffusion adversely affected the performance, especially when we maintained high pressure lifts.

25 ENERGY STORAGE↗

A hierarchical gray-box dynamic modeling methodology for direct-expansion cooling systems to support control stability analysis; Méthodologie de modélisation dynamique hiérarchique de type boîte grise pour les systèmes de refroidissement à détente directe afin de soutenir l'analyse de stabilité de la commande

In this paper, a gray-box dynamic modeling approach for direct-expansion cooling systems is presented. The overall approach incorporates a multi-stage training procedure that consists of 1) identification of component sub-models from quasi-steady-state performance data, 2) system model integration with estimation of refrigerant charge and 3) fine tuning of thermal capacitances of the evaporator and condenser to capture the system dynamic responses. Compared to traditional physics-based models, the proposed modeling approach has advantages including reduced engineering efforts in the model development phase, improved computational efficiency and enhanced prediction accuracy. The modeling method was validated using a 3-ton variable-speed heat pump and proved to be capable of accurately predicting the system transient behaviors over a wide range of operating conditions. The established dynamic model was then applied for control stability analysis, with a specific goal of determining a proper control execution time step. The case study results showed that the stable control execution time step could change significantly, from 3 sec to 19 sec, as the operating conditions and control settings vary, and a proper selection of the execution time step is critical to ensure stable and reliable operations.

42 ENGINEERING↗