Projecting Future Energy Production from Operating Wind Farms in North America. Part III: Variability

Abstract Daily expected wind power production from operating wind farms across North America are used to evaluate capacity factors (CF) computed using simulation output from the Weather Research and Forecasting (WRF) Model and to condition statistical models linking atmospheric conditions to electricity production. In Parts I and II of this work, we focus on making projections of annual energy production and the occurrence of electrical production drought. Here, we extend evaluation of the CF projections for sites in the Northeast, Midwest, southern Great Plains (SGP), and southwest U.S. coast (SWC) using statewide wind-generated electricity supply to the grid. We then quantify changes in the time scales of CF variability and the seasonality. Currently, wind-generated electricity is lowest in summer in each region except SWC, which causes a substantial mismatch with electricity demand. While electricity of residential heating may shift demand, research presented here suggests that summertime CF are likely to decline, potentially exacerbating the offset between seasonal peak power production and current load. The reduction in summertime CF is manifest for all regions except the SGP and appears to be linked to a reduction in synoptic-scale variability. Using fulfillment of 50% and 90% of annual energy production to quantify interannual variability, it is shown that wind power production exhibits higher (earlier fulfillment) or lower (later fulfillment) production for periods of over 10–30 years as a result of the action of internal climate modes. Significance Statement Electrical power system reassessment and redesign may be needed to aid efficient increased use of variable renewables in the generation of electricity. Currently wind-generated electricity in many regions of North America exhibits a minimum in summertime and hence is not well synchronized with electricity demand, which tends to be maximized in summer. Future projections indicate evidence of reductions in wind power during summer that would amplify this offset. However, electrification of heating may lead to increased wintertime demand, which would lead to greater synchronization.

Coburn, Jacob↗

Redesigning capacity market to include flexibility via ramp constraints in high-renewable penetrated system

Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing of Quaternary Pumped Storage Hydropower for Dynamic Studies

Quaternary pumped storage hydropower (Q-PSH) technology, as one of the new advanced-PSH technology, has been developed by taking advantage of Conventional-PSH (C-PSH) and Adjustable Speed-PSH (AS-PSH). By combining adjustable-speed pump unit and conventional hydropower turbine unit in the quaternary configuration, Q-PSH has the more competitive capability of providing fast power support in the future high renewable penetrated power system. Acting as energy storage (ES), Q-PSH provides promising power supply to deal with the uncertainty and variability from renewable energy generation. This paper focuses on the dynamic modeling of Q-PSH technology employing full-converter machine and the impact of Q-PSH on the frequency response in a system. The detailed model of Q-PSH is developed and implemented in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform, which captures the dynamic of multiple operation modes, especially hydraulic short-circuit (HSC) operation mode. Several cases are set up to reveal the advantages of Q-PSH technology when power electronic based renewable energy generation is deployed in the system. Sensitivity studies of the controller in pump governor show the impact of parameters in pump response performance. The comparison case illustrates the impact of frequency response provided by the Q-PSH in the system.

dynamic modeling↗

Development Support for NREL's System Advisor Model (SAM): Cooperative Research and Development, CRADA Number CRD-20-16998 (Final Report)

The variable nature of renewable generation, which depends on the sun shining and wind blowing for example, presents challenges for adequate and least-cost resource planning. The deployment of renewable generation assets is anticipated to increase due to various drivers, such as declining costs, favorable government policies, and increasing procurement by corporations and consumers. High levels of renewable penetration are anticipated to pose flexibility, reliability, and cost challenges to the electrical system. The development and implementation of new features into performance modeling software, such as the National Renewable Energy Laboratory's (NREL) System Advisor Model (SAM), is one way to help think through these challenges and develop appropriate strategies.

14 SOLAR ENERGY↗

Addressing technical challenges in 100% variable inverter-based renewable energy power systems

Rapidly increasing levels of variable inverter-based renewable energy sources are quickly changing electric power systems and prompting questions about how the systems will be operated when renewable generation becomes the dominant technologies. Here, we review the status of this shifting paradigm in power systems throughout the world. We then review the implications of this shift, focusing on the rising challenges, and we provide an overview and technology-readiness classifications of some proposed mitigation strategies. Finally, we highlight outstanding questions that will require solutions to reach these ultrahigh shares of variable inverter-based renewable energy sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Pathways to the Next-Generation Power System With Inverter-Based Resources: Challenges and recommendations

Managing the stability of today's electric power systems is based on decades of experience with the physical properties and control responses of large synchronous generators. Today's electric power systems are rapidly transitioning toward having an increasing proportion of generation from nontraditional sources, such as wind and solar (among others), as well as energy storage devices, such as batteries. In addition to the variable nature of many renewable generation sources (because of the weather-driven nature of their fuel supply), these newer sources vary in size - from residential-scale rooftop systems to utility-scale power plants - and they are interconnected throughout the electric grid, both from within the distribution system and directly to the high-voltage transmission system. Most important for our purposes, many of these new resources are connected to the power system through power electronic inverters. Collectively, we refer to these sources as inverter-based resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy, economic, and environmental tradeoffs at run-of-river hydropower facilities

Hydropower’s ability to quickly adapt to variability from wind and solar generation by fluctuation flow rates can allow the electricity grid to integrate more renewable capacity. However, these rapid flow fluctuations, required to meet variability needs, can negatively impact aquatic ecosystems. In this study, we quantified energy-economic-environment tradeoffs at five conventional hydropower facilities (i.e. hydropower produced ad a dam on a river channel) across the United States to identify a mix of operational regimes that can provide flexibility to support variable renewable energy integration and environmental protections. Model results show a range of ability to meet demand from 4.7% to 97.8% depending on which case study is considered. Additionally, when modeling the case study facilities on a range of RoR conditions, allowing a % of inflow as discharge, we found the range of 140–200% of inflow allowed as discharge lead to lowest environmental impact while meeting the highest amount of demand. Our sensitivity analysis results demonstrated the Richard-Baker Flashiness Index, used to measure flowrate changes, and Revenue, were negatively correlated with the percent of hydropower generation within the defined Regional Energy Deployment System balancing area (i.e. region in which energy demand and energy supply is balanced based on the Regional Energy Deployment System model) yet positively correlated to the variable renewable energy generation percentage in the defined balancing area. In conclusion, our results suggest hydropower operations can aid in increasing renewable energy generation while limiting environmental impacts when considering a holistic analysis of energy-economic-environment tradeoffs.

Economic impact↗

Electric Vehicle Managed Charging: Forward-Looking Estimates of Bulk Power System Value

When and where electric vehicle charging occurs has significant implications for power systems supporting widespread electric vehicle deployment with high shares of wind and solar generation. Numerous studies have estimated the value of scheduling or otherwise managing electric vehicle charging in such power systems. This study improves on those earlier works by leveraging detailed simulation models for electric vehicle adoption, electric vehicle use, electric vehicle charging, and bulk power system operations; and linking them with methods for describing charging flexibility at both the individual vehicle and aggregate levels. This study closely analyzes electric vehicle managed charging (EVMC) performance along the dimensions of flexibility type (within-charging session or within-week scheduling), dispatch mechanism (direct load control or one of several price-based mechanisms), and participation rate, under the assumptions of ubiquitous chargers and all trips completed on time. The study is located in a passenger light-duty vehicle adoption scenario with 100% electric vehicle sales by 2035, and in an envisioned 2038 New England power system for which within-region generation is 84% clean.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Siting Analysis of a Solar-Nuclear-Desalination Integrated Energy System

Nuclear power is typically deployed as a baseload generator. Increased penetration of variable renewables motivates combining nuclear and renewable technologies into Integrated Energy Systems (IES) to improve dispatchability, component synergies and, through cogeneration, address multiple markets. However, combining multiple energy resources heavily depends on the proper selection of each system’s location and design limitations. In this paper, co-siting options for IES that couple nuclear and concentrating solar power (CSP) with thermal desalination are investigated. A comprehensive siting analysis is performed that utilizes global information survey data to determine possible co-siting options for nuclear and solar thermal generation in the United States. Viable co-siting options are distributed across the Southwestern U.S., with the greatest concentration of siting options in the southern Great Plains, although siting with higher solar direct normal irradiance is possible in other states such as Arizona and New Mexico. Brackish water desalination is also attractive across the southwest U.S. due to high water stress, but for brackish water desalination reverse osmosis (an electricity driven process) is most cost- and energy-efficient, which does not require co-siting with the thermal generator. The most attractive state for nuclear and thermal desalination (which is more attractive when using seawater) is Texas, although other areas may become attractive as water stress increases over the coming decades. Co-siting of all CSP and thermal desalination is challenging as attractive CSP sites are not coastal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Big Data Analytic for Cascading Failure Analysis

With the challenges of increased grid dynamics and more variability of power generation from renewable energy sources, rapidly increasing complexity in the grid model, and abundant data from measurements and simulations, the requirements for computational analysis have also increased dramatically. Power system operators and engineers need to analyze more scenarios, extract meaningful information from a larger set of data, and respond more quickly when faced with these new challenges for large-scale applications, such as contingency analysis. This paper proposes a novel big data analysis approach for power system cascading analysis, prevention, and remediation. The developed techniques will be capable of cascading analysis, better assessment of the system’s vulnerability level, as well as proposing potential remediation. Case studies using IEEE 118-bus system and a 500-bus system, with a comparison against a commercial tool, validate the advantages of the developed big data approach: accurate prediction, and more importantly, faster and effective correction actions.The developed techniques could be further used for other power system applications.

big data, cascading analysis, corrective action, m↗

Role of Electric Vehicles in the U.S. Power Sector Transition: A System-Level Perspective

After over a century of petroleum dominance many anticipate that electrification could disrupt the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes: variable renewables are displacing conventional generation sources; distributed generation is disrupting utility business models; energy storage and other new technologies are emerging; and the traditional system based on the premise that generation is dispatched to match an inelastic demand is evolving to create a system with greater participation in power system planning and operations from traditionally passive consumers. In this context, it is important to understand how transportation electrification will impact electricity demand and in turn electricity supply, including changes in the load shapes that characterize the system and the opportunity to leverage flexible electric vehicle (EV) charging to better integrate demand and supply. Assessing the impacts of electrification on the energy system requires an understanding of how it might impact the amount and shape of electricity consumption, and how this electricity can be supplied. In particular, increased adoption of electric vehicles introduces a new source of demand altogether, potentially very flexible. Moreover, electrification could shift the consumption of natural gas between sectors, thereby affecting the economics for natural gas-fired generation relative to other electricity generation options. Several factors will impact the evolution of the power system under a widespread electrified future, which, in turn, could have far-reaching effects on future energy costs and emissions.

47 OTHER INSTRUMENTATION↗

Federated Architecture for Secure and Transactive Distributed Energy Resource Management Solutions

There are fewer conventional, dispatchable generation resources and more variable renewable energy (VRE) and distributed energy resources (DERs). There is more uncertainty from bulk-level VRE and net demand from distribution systems with high DER levels. FAST-DERMS aims to develop and demonstrate a scalable solution for managing uncertainties in supply and demand at the grid edge. We propose that distribution system operators (DSOs) provide firm net load forecasts to the bulk system operator's energy management system (EMS).

distributed energy resources↗

Projecting Electric Vehicle Electricity Demands and Charging Loads

After over a century of petroleum dominance, electric vehicles are rapidly disrupting the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes as variable renewables replace dispatchable fossil generators. It is critically important to understand how transportation electrification will impact electricity demand, including changes in the load shapes that characterize the system, and the value of flexible electric vehicle charging to better balance electricity demand and supply. This talk focuses on methods to project electricity demand for EV charging with high spatiotemporal fidelity to enable electricity system modeling and analysis and summarizes results from recent NREL studies in this area.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Stability-Constrained Learning for Frequency Regulation in Power Grids With Variable Inertia

The increasing penetration of converter-based renewable generation has resulted in faster frequency dynamics, and low and variable inertia. As a result, there is a need for frequency control methods that are able to stabilize a disturbance in the power system at timescales comparable to the fast converter dynamics. This paper proposes a combined linear and neural network controller for inverter-based primary frequency control that is stable at time-varying levels of inertia. We model the time-variance in inertia via a switched affine hybrid system model. We derive stability certificates for the proposed controller via a quadratic candidate Lyapunov function. We test the proposed control on a 12-bus 3-area test network, and compare its performance with a base case linear controller, optimized linear controller, and finite-horizon Linear Quadratic Regulator (LQR). Our proposed controller achieves faster mean settling time and over 50% reduction in average control cost across 100 inertia scenarios compared to the optimized linear controller. Unlike LQR which requires complete knowledge of the inertia trajectories and system dynamics over the entire control time horizon, our proposed controller is real-time tractable, and achieves comparable performance to LQR.

data-driven control↗

Energy innovation in the US buildings sector: Setting the stage and mapping the future

Jared Langevin is a staff scientist at Lawrence Berkeley National Laboratory, where he leads modeling of US buildings sector innovation and its implications for energy demand, consumer costs, and the power grid. Eric Wilson is a senior research engineer in the Building Technologies and Sciences Center at the National Renewable Energy Laboratory (NREL). Much of his 15-year career at NREL has revolved around modeling and analysis of the US building stock. Jared and Eric co-led the development of a National Blueprint for buildings sector innovation while serving as advisors to the US Department of Energy’s Deputy Assistant Secretary for Buildings and Industry.

Langevin, Jared↗

Hybrid-energy approach enabled by heat storage and oxy-combustion to generate electricity with near-zero or negative CO 2 emissions

We assess a hybrid-energy approach that modifies a steam-turbine power plant to use renewable energy sources (electricity, plus options for geothermal and solar heat), plus fossil fuel (natural gas and coal) and/or waste biomass (e.g., Douglas fir woodchips). Heat storage allows heat to be created during periods of excess energy supply and for that heat to be converted to electricity when demanded. Excess electricity, such as from variable renewable energy (VRE), is used to generate oxygen for oxy-combustion furnaces that create very-hot, high-purity CO 2 that heats granular rock beds in insulated vessels. Cool CO 2 leaving the beds is dried, sent to compressors powered by excess VRE electricity, before being sent by pipeline to geologic CO 2 storage. Very-hot CO 2 transfers high-grade heat from storage to the power plant in a closed loop that returns medium-grade heat back to storage, allowing low- and medium-grade renewable-heat sources to be stacked beneath combustion heat, with all heat sources being converted to electricity at the same (high) thermal efficiency. Reliable, on-demand power may be generated with near-zero CO 2 emissions with fossil fuel and with negative CO 2 emissions with waste biomass. Our analyses show that with fossil fuel, up to 35% of gross power can be derived from renewable sources, while for waste biomass, it can be entirely derived from renewable sources. Because our approach has the potential to ensure that grids have a continuous supply of clean energy and because electricity is only generated once, when demanded, it could serve as an efficient alternative to bulk energy storage.

30 DIRECT ENERGY CONVERSION↗

Evaluating the demand response potential of ammonia plants

Demand-side management/demand response (DSM/DR) are key strategies for mitigating the inherent variability in electricity generation rates by renewable sources. This article represents—to our knowledge—the first foray into assessing the DR potential of ammonia plants. Ammonia plants are interesting candidates for DR initiatives because of their significant electricity use (for operating compressors driving the synthesis loop) and the ability to store the ammonia product relatively easily and safely. Our approach is based on formulating and solving an optimal DR scheduling problem for an ammonia plant while accounting for the process dynamics. To this end, we introduce a new Hammerstein–Wiener-inspired modeling framework based on injecting linear dynamics in a first-principles static nonlinear model of the process. The results are encouraging; for the cases considered, peak-time power consumption decreases between 3.57% and 7.40%, coupled with 1.39% to 3.70% reductions in operating cost.