Predicting Monte Carlo Tally Variance and Calculation Time when using Forced-flight Variance Reduction—Verification
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Over the past few decades, hybrid Monte-Carlo-Deterministic (MC-DT) techniques have been mostly focusing on the development of techniques primarily with shielding applications in mind, i.e. problems featuring a limited number of responses. This paper focuses on the application of a new hybrid MC-DT technique: the SUBSPACE method, for reactor analysis calculation. The SUBSPACE method is designed to overcome the lack of efficiency that hampers the application of MC methods in routine analysis calculations on the assembly level where typically one needs to execute the flux solver in the order of 10{sup 3}-10{sup 5} times. It places high premium on attaining high computational efficiency for reactor analysis application by identifying and capitalizing on the existing correlations between responses of interest. This paper places particular emphasis on using the SUBSPACE method for preparing homogenized few-group cross section sets on the assembly level for subsequent use in full-core diffusion calculations. A BWR assembly model is employed to calculate homogenized few-group cross sections for different burn-up steps. It is found that using the SUBSPACE method significant speedup can be achieved over the state of the art FW-CADIS method. While the presented speed-up alone is not sufficient to render the MC method competitive with the DT method, we believe this work will become a major step on the way of leveraging the accuracy of MC calculations for assembly calculations. (authors)
In order to avoid unnecessary radiation exposure and to minimize the radioactive waste and respectively cost by the decommissioning of nuclear facilities, the radiological characteristics and the activity atlases are required. Therefore, a significant step is the accurate determination of the neutron fluence distribution resulting from the operation of a reactor. For this purpose, computer codes based on the Monte-Carlo method are employed because of the flexibility in the modelling of the complex structures and physical processes. In the scope of the research project founded by the German Federal Ministry of Education and Research (BMBF), and implemented by the Institute of Nuclear Engineering and Technology Transfer (NET) -RWTH Aachen, sophisticated simulation tools are developed, which have the capability to cover the range of demands for activity and dose rate distribution using the example of the German research reactor FRJ-2. Due to the complex geometry of FRJ-2, which consists of different structures and configuration, the MCNP5 Monte Carlo Code is the optimal method for a precise neutron transport simulation. This work presents a method to achieve a precise N-Flux distribution for the FRJ-2 research reactor using hybrid deterministic Monte Carlo method. (authors)
The MTINV toolkit (2002-present) is a collection of computer codes and applications written to invert for the moment tensor of a seismic source given the three components of ground motion recorded at regional seismic stations (e.g., Ichinose et al., 2003). The computer codes and workflow are organized to generate moment tensor solutions for a range of source depths and origin times because of the trade-off between these two quantities. The metric used is the variance reduction and variance reduction modulated by the percent double-couple to determine the best-fit moment-tensor solution. We can solve for a deviatoric moment tensor with a constraint added for no isotropic component although this constraint can be lifted for estimating the full moment tensor like mining collapses or explosion sources.
Detailed spatial distributions of the biological dose rate due to a variety of sources are required for the design of the ITER tokamak facility to ensure that all radiological zoning limits are met. During operation, water in the Integrated loop of Blanket, Edge-localized mode and vertical stabilization coils, and Divertor (IBED) cooling system will be activated by plasma neutrons and will flow out of the bioshield through a complex system of pipes and heat exchangers. This paper discusses the methods used to characterize the biological dose rate outside the tokamak complex due to 16 N gamma radiation emitted by the activated coolant in the Neutral Beam Injection (NBI) cell of the tokamak building. Activated coolant will enter the NBI cell through the IBED Primary Heat Transfer System (PHTS), and the NBI PHTS will also become activated due to radiation streaming through the NBI system. To properly characterize these gamma sources, the production of 16 N, the decay of 16 N, and the flow of activated water through the coolant loops were modeled. The impact of conservative approximations on the solution was also examined. Once the source due to activated coolant was calculated, the resulting biological dose rate outside the north wall of the NBI cell was determined through the use of sophisticated variance reduction techniques. The AutomateD VAriaNce reducTion Generator (ADVANTG) software implements methods developed specifically to provide highly effective variance reduction for complex radiation transport simulations such as those encountered with ITER. Using ADVANTG with the Monte Carlo N-particle (MCNP) radiation transport code, radiation responses were calculated on a fine spatial mesh with a high degree of statistical accuracy. In conclusion, advanced visualization tools were also developed and used to determine pipe cell connectivity, to facilitate model checking, and to post-process the transport simulation results.
The recent growth in multifidelity uncertainty quantification has given rise to a large set of variance reduction techniques that leverage information from model ensembles to provide variance reduction for estimates of the statistics of a high-fidelity model. In this paper we provide two contributions: (1) we utilize an ensemble estimator to account for uncertainties in the optimal weights of approximate control variate (ACV) approaches and derive lower bounds on the number of samples required to guarantee variance reduction; and (2) we extend an existing multifidelity importance sampling (MFIS) scheme to leverage control variates. Our approach directly addresses a limitation of many multifidelity sampling strategies that require the usage of pilot samples to estimate covariances. As such we make significant progress towards both increasing the practicality of approximate control variates—for instance, by accounting for the effect of pilot samples—and using multifidelity approaches more effectively for estimating low-probability events. The numerical results indicate our hybrid MFIS-ACV estimator achieves up to 50% improvement in variance reduction over the existing state-of-the-art MFIS estimator, which had already shown an outstanding convergence rate compared to the Monte Carlo method, on several problems of computational mechanics.
Here, this paper presents a comparative study of dose rate calculations for the ES-3100 package with highly enriched uranium (HEU) content for different source configurations using computer codes: (1) MCNP; (2) Automated Variance Reduction Generator (ADVANTG)/MCNP; (3) Monaco; and (4) Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC). The Model ES-3100 package was developed at the Y-12 National Security Complex for domestic and international transportation of Type B fissile radioactive material. In this study, six different source configurations (i.e., solid cylinder, cylindrical hemi-shell, cylindrical shell, rectangular plate, cylindrical rod, or cylindrical segment form) having 36 kg of HEU metal inside the package containment vessel (based on configurations in the ES-3100/HEU safety analysis report for packaging) are evaluated. Dose rates at the package surfaces and 1 m from the package surfaces are calculated for these different source configurations. MCNP and Monaco cases are run without any biasing options to accelerate the convergence. Consistent Adjoint Driven Importance Sampling (CADIS) and Forward-Weighted CADIS (FW-CADIS) methods developed at the Oak Ridge National Laboratory are implemented in ADVANTG/MCNP and MAVRIC codes to accelerate the convergence. ADVANTG generates variance reduction parameters using Denovo code, and MCNP is used with the variance reduction parameters to accelerate the convergence. MAVRIC uses Denovo code to construct an importance map and a biased source distribution that are supplied to Monaco to accelerate the Monte Carlo simulation. The FW-CADIS option in ADVANTG and MAVRIC is used to accelerate the convergence in this study. The accelerated convergence cases (ADVANTG/MCNP and MAVRIC) are about 100 times faster with 100 times less particle simulation than those cases run without biasing options (analog MCNP and analog Monaco). Lastly, the MCNP, ADVANTG/MCNP, Monaco, and MAVRIC calculated dose rates at the package surfaces and at 1 m from the package surfaces for the different source configurations are compared and are found to be in general agreement.
This paper presents a comparative study of dose rate calculations for the ES-3100 package with highly enriched uranium (HEU) content for different source configurations using computer codes: (1) MCNP; (2) Automated Variance Reduction Generator (ADVANTG)/MCNP; (3) Monaco; and (4) Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC). The Model ES-3100 package was developed at the Y-12 National Security Complex for domestic and international transportation of Type B fissile radioactive material. In this study, six different source configurations (i.e., solid cylinder, cylindrical hemi-shell, cylindrical shell, rectangular plate, cylindrical rod, or cylindrical segment form) having 36 kg of HEU metal inside the package containment vessel (based on configurations in the ES-3100/HEU safety analysis report for packaging) are evaluated. Dose rates at the package surfaces and 1 m from the package surfaces are calculated for these different source configurations. MCNP and Monaco cases are run without any biasing options to accelerate the convergence. Consistent Adjoint Driven Importance Sampling (CADIS) and Forward-Weighted CADIS (FW-CADIS) methods developed at the Oak Ridge National Laboratory are implemented in ADVANTG/MCNP and MAVRIC codes to accelerate the convergence. ADVANTG generates variance reduction parameters using Denovo code, and MCNP is used with the variance reduction parameters to accelerate the convergence. MAVRIC uses Denovo code to construct an importance map and a biased source distribution that are supplied to Monaco to accelerate the Monte Carlo simulation. The FW-CADIS option in ADVANTG and MAVRIC is used to accelerate the convergence in this study. The accelerated convergence cases (ADVANTG/MCNP and MAVRIC) are about 100 times faster with 100 times less particle simulation than those cases run without biasing options (analog MCNP and analog Monaco). The MCNP, ADVANTG/MCNP, Monaco, and MAVRIC calculated dose rates at the package surfaces and at 1 m from the package surfaces for the different source configurations are compared and are found to be in general agreement.
Monte Carlo (MC) radiation transport simulations, like those performed using Monte Carlo N-Particle (MCNP), can be highly accurate but require time to reduce the statistical uncertainties in the calculated detector response(s). Many different 'variance reduction' techniques devised over the years increase the efficiency of MC calculations, but these methods can be more art than science. Many of these methods are problem specific or require careful tuning of parameters for good performance. One of the best variance reduction methods, in terms of both reliable performance increases and ease of use, is the use of weight windows. Weight windows are derived from an importance map in space and energy that allows the transport code to focus more simulation time on particles that have a higher likelihood of being important to the final detector response. Less time is spent simulating particles that have little chance of making a contribution to the detector response. MCNP already includes the abilities to generate and use weight windows. Unfortunately, generating weight windows can take a very long time, perhaps longer than the original problem. Oak Ridge National Laboratory has led the development of hybrid methods using a discrete ordinates adjoint calculation to quickly develop an importance map (weight windows) for use in a Monte Carlo code. The Consistent Adjoint Driven Importance Sampling (CADIS) method uses an adjoint calculation to develop both an importance map and a biased source distribution that work together. This method is reasonably automatic, is easy to use, and has been implemented in the Automated Variance reduction Generator (ADVANTG) package that works with MCNP5. ADVANTG reads an MCNP input file and a small amount of extra user information and then runs an adjoint deterministic calculation using Denovo. The importance map and biased source distribution derived from the CADIS method can then be incorporated back into the original MCNP input file to enhance the figure-of-merit (FOM) of the calculation. The FOM is a measure of the efficiency of the calculation using the amount of run time and corresponding level of statistical uncertainty in the detector result. ADVANTG-enhanced MCNP input files have been shown to increase the FOM of many types of problems, obtaining the same level of statistical uncertainty in a shorter time compared to standard MCNP. ADVANTG can also generate variance reduction parameters (importance map and biased source) using the Forward-Weighted CADIS (FW-CADIS) method for optimizing mesh tallies. The CADIS method creates variance reduction parameters that optimize a tally's total quantity (flux, dose rate, interaction rate, etc.) and will not generally increase performance for all parts of a segmented tally. To optimize a segmented tally, the FW-CADIS method uses two discrete ordinates calculations to make variance reduction parameters that help compute a segmented tally with uniform relative uncertainties in each bin. This report will demonstrate that using ADVANTG for neutron and photon radiation shielding problems will (1) preserve the standard MCNP results and (2) obtain those results either with less statistical uncertainty or in shorter times than the standard MCNP calculation. The four demonstration problems in this report are based on simple neutron or photon transmission measurements through different materials. All of the problems here used the CADIS method and still saw improvement across the flux tallies segmented by particle energy. (authors)
We describe and analyze a variance reduction approach for Monte Carlo (MC) sampling that accelerates the estimation of statistics of computationally expensive simulation models using an ensemble of models with lower cost. These lower cost models — which are typically lower fidelity with unknown statistics — are used to reduce the variance in statistical estimators relative to a MC estimator with equivalent cost. We derive the conditions under which our proposed approximate control variate framework recovers existing multifidelity variance reduction schemes as special cases. We demonstrate that existing recursive/nested strategies are suboptimal because they use the additional low-fidelity models only to efficiently estimate the unknown mean of the first low-fidelity model. As a result, they cannot achieve variance reduction beyond that of a control variate estimator that uses a single low-fidelity model with known mean. However, there often exists about an order-of-magnitude gap between the maximum achievable variance reduction using all low-fidelity models and that achieved by a single low-fidelity model with known mean. We show that our proposed approach can exploit this gap to achieve greater variance reduction by using non-recursive sampling schemes. The proposed strategy reduces the total cost of accurately estimating statistics, especially in cases where only low-fidelity simulation models are accessible for additional evaluations. Several analytic examples and an example with a hyperbolic PDE describing elastic wave propagation in heterogeneous media are used to illustrate the main features of the methodology.
Here, a key challenge for current and upcoming cosmic microwave background lensing measurements is their sensitivity to biases from extragalactic foregrounds, such as Sunyaev-Zel'dovich signals or cosmic infrared background emission. Several methods have been developed to mitigate these lensing foreground biases, dividing broadly into multifrequency cleaning approaches and modifications to the estimator geometry, but how to optimally combine these methods has not yet been explored in detail. In this paper, we examine which combination of lensing foreground mitigation strategies is best able to reduce the impact of foreground contamination for a Simons Observatory-like experiment while preserving maximal signal-to-noise. Although the optimal combination obtained depends on whether bias reduction or variance reduction is prioritized and on whether polarization data is used, generally, we find that combinations involving both geometric (profile hardening, source hardening, or shear) and multifrequency (symmetric cleaning) methods perform best. For lensing power spectrum measurements from temperature (polarization and temperature), our combined estimator methods are able to reduce the bias below σ/4 or 0.3% (0.1%), a factor of 16 (30) lower than the standard quadratic estimator bias, at a modest signal-to-noise cost of only 18% (12%). In contrast, single-method foreground-mitigation approaches struggle to reduce the bias to a negligible level below σ/2 without incurring a large noise penalty. For upcoming and current experiments, our combined methods therefore represent a promising approach for making lensing measurements with negligible foreground bias.
The Robbins-Monro stochastic approximation algorithm is a foundation of many algorithmic frameworks for reinforcement learning and often an efficient approach to solving (or approximating the solution to) complex optimal control problems. In many cases, however, practitioners are unable to apply these techniques because of an inherent high variance. This paper aims to provide a general foundation for 'quasi-stochastic approximation,' in which all of the processes under consideration are deterministic, much like quasi-Monte Carlo for variance reduction in simulation. The variance reduction can be substantial, subject to tuning of pertinent parameters in the algorithm. This paper introduces a new coupling argument to establish the optimal rate of convergence provided the gain is sufficiently large. These results are established for linear models and tested also in nonideal settings. A major application of these general results is a new class of reinforcement learning algorithms for deterministic state space models. In this setting, the main contribution is a class of algorithms for approximating the value function for a given policy, using a different policy designed to introduce exploration.
This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)
Here, we prove a theorem relating the variance of path length estimators for single-collision Monte Carlo source iteration to a parameter that becomes infinitesimally small in an important physical regime arising in radiative transfer. In our usage, “single-collision Monte Carlo source iteration” refers to Monte Carlo Boltzmann transport methods in which each Monte Carlo particle history includes no more than a single collision, and the physics of multiple scattering is modeled by lagging the scattering source term and iterating until this term converges. Our theorem can be used to construct variance reduction techniques which improve the order of the estimator variance. This enables calculations that would otherwise require impractically large sample sizes to achieve practical estimator uncertainties. We believe this is the first postulation of a theorem relating estimator variance to a limiting case parameter for single-collision Monte Carlo source iteration, and the first proof of such a theorem. We illustrate the theorem’s value with an example in which the authors of a transport method used the theorem to design a variance reduction technique that improved the uncertainty of their solution by a factor of about 500 for a proxy problem from radiative transfer that contains both optically-thick and optically-thin material.
The High Flux Isotope Reactor (HFIR) Controller (HFIRCON) code is a collection of python routines and C plugins that automate the workflow for fuel and single- or multicycle target depletion analyses for HFIR at Oak Ridge National Laboratory (ORNL). This code calls the LAVAMINT (LAVA Model Interrogator) parallel (MCNP) Monte Carlo N-Particle model interrogator to stochastically calculate cell volumes and bounding boxes, the ADVANTG (Automatic Variance Reduction Generation) code package for all variance reduction and source biasing calculations, the ORNL-Transformative Neutronics/MCNP5 transport solver for all transport solutions, and the MSX_DEPLETE module to perform all depletion calculations via the ORIGEN (Oak Ridge Isotope Generation) application programming interface. It also performs a robust set of postprocessing functions to automatically provide summaries of several key metrics that are common to a wide variety of typical HFIR design and safety-basis analyses.
This study presents a detailed comparison of the dose rate distributions of a dry TN–32 fuel cask with two geometry models and two cross-sectional datasets. The accuracies of radiation dose rate estimation and computational efficiencies of each geometry model with two cross-sectional data-sets are compared. The use of automated variance reduction techniques can significantly improve the computational efficiency of such a realistic, deep penetration problem that involves radiation transport from different volumetric sources, thereby eliciting only a small statistical error. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is a computational sequence within the SCALE 6.2 code package based on consistent adjoint driven importance sampling (CADIS), a type of automated variance reduction technique. Homogenous and full fuel assembly models are built herein, and two nuclear cross-section libraries (V7–200N47G and continuous energy) are applied in this work. Based on the detailed comparisons, we found that neutron dose rate estimation is more dependent on geometry modeling than on cross-section data. For neutron-induced gamma rays, the dose rate distribution depends on both the spatial self-shielding effect and the cross-section library. The primary gamma rays respectively contribute to the total dose rate by ~91% and ~ 99% on side and top surfaces, and the dose rate accuracy is more dependent on the cross-section library than on geometry modeling. In terms of the computation efficiency and efforts spent on geometry modeling, the homogenous fuel assembly model with the MG library can produce an acceptable dose rate distribution, but the detailed fuel assembly model with the continuous-energy library is required for more precise dose rate estimation.