Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Understanding Evolution of Lithium Trivanadate Cathodes During Cycling via Reformulated Physics-Based Models and Experiments

Degradation of lithium trivanadate ( Li x V 3 O 8 ) cathodes has been widely reported in the literature, but studies have offered little insight towards developing a detailed understanding of the evolution of the active material, and have been inconclusive as to the root cause of degradation. Here, we refit a validated physics-based model to discharge curves over the course of cycling at C/5, and use the evolution of the model parameters to track evolution of the cathode. A regularization penalty for adjusting model parameters from the validated model is introduced as a framework to identify which model parameters can explain a significant portion of the observed change in the voltage profile over the course of cycling. SEM reveals that lithium trivandate particles fracture upon cycling at C/5, consistent with the results of the parameter estimation, deactivation of lithium trivanadate and faster diffusion of lithium within the active particles. The physics-based model is then used to design modified cycling protocols which identify the phase transformation during discharge of lithium trivanadate as the driver of the particle fracture and capacity fade.

25 ENERGY STORAGE↗

Tuning the Porous Structure in PMMA-Templated Mesoporous MoO 2 for Pseudocapacitive Li-Ion Electrodes

MoO 2 is an exciting candidate for next-generation energy storage. It can be used for fast-charging applications in nanoscale form, but its kinetic performance is often limited by insulating MoO 3 surface oxide layers. Here, we developed methods to produce polymer-templated porous MoO 2 powders where electrical conductivity was well-maintained throughout the structure, even in the presence of some surface oxidation. Porosity, pore size, and crystallite size were controlled by varying the amount and size of the colloidal templates and through calcination temperature. The electrochemical performance was correlated with nanoscale structure: samples with high porosity, medium pore sizes, and good crystallinity display optimal rate capabilities, with over 100 mAh g −1 delivered in 3 min and 93% capacity retention after 1000 cycles. Kinetic studies were performed on samples with the largest and smallest crystallite sizes to understand the charge storage mechanism. In the sample with the smallest crystallite size, 85% of the total stored charge was capacitive, compared to 60% for the largest crystallite size. Sloping voltage profiles in materials with smaller domain sizes further suggest suppression of intercalation-induced phase transitions. This work thus provides insights into the mechanisms of charge storage in nanoscale MoO 2 and design parameters for the production of fast charging materials.

25 ENERGY STORAGE↗

Capacity and Coulombic Efficiency Measurements Underestimate the Rate of SEI Growth in Silicon Anodes

Capacity measurements and related quantities are the first layer of information acquired during testing of Li-ion cells. It is generally considered that elevated values of coulombic efficiency and capacity retention are absolute indicators of the existence of a stable solid electrolyte interphase (SEI). Here, we challenge this notion by analyzing how the effect of side reactions on cell capacity depends on the choice of electrodes. More specifically, we demonstrate that the extent of measurable capacity fade due to SEI growth is modulated by the shape of the voltage profile of the cathode and anode at the end of charge and discharge half-cycles. This shape-dependency creates a mismatch between SEI growth and cell capacity loss, which is relatively small for graphite anodes but sizable for silicon-containing electrodes. We illustrate this point by showing that, at the same coulombic efficiency and capacity retention, cells containing silicon-based materials could actually exhibit rates of SEI growth that are as much as ≥ 40% higher than graphite cells. The main implication of this behavior is that, for certain systems, capacity measurements may be an unreliable source of information about the extent of reactions at the SEI, allowing other consequences of these side reactions (such as electrolyte depletion) to proceed unchecked while the cell appears to be stable.

25 ENERGY STORAGE↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Voltage Control Strategy for Energy Storage System in Sustainable Distribution System Operation

Due to the increasing penetration of distributed energy resources (DERs) required for the sustainable distribution system, new voltage control strategy is needed by utilities. Traditional voltage control strategy can not support the increasing number of DERs in a coordinated and scalable manner to meet the operational voltage regulation requirement. Supported by the power electronics converter, the energy storage system can provide fast, smooth, and flexible voltage control services. In this paper, an effective and easy to implement sensitivity-based voltage control strategy is developed for the energy storage system. The developed control strategy is validated using an industrial feeder data in Northwest Washington. The proposed strategy can mitigate the voltage unbalance issue, improve the voltage profile, and correct power factors while supporting sustainable distribution system operation.

Zhang, Yue (ORCID:0000000241469716)↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insights into Layered Oxide Cathodes for Rechargeable Batteries

Layered intercalation compounds are the dominant cathode materials for rechargeable Li-ion batteries. In this article we summarize in a pedagogical way our work in understanding how the structure’s topology, electronic structure, and chemistry interact to determine its electrochemical performance. We discuss how alkali–alkali interactions within the Li layer influence the voltage profile, the role of the transition metal electronic structure in dictating O3-structural stability, and the mechanism for alkali diffusion. We then briefly delve into emerging, next-generation Li-ion cathodes that move beyond layered intercalation hosts by discussing disordered rocksalt Li-excess structures, a class of materials which may be essential in circumventing impending resource limitations in our era of clean energy technology.

25 ENERGY STORAGE↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Synthetic, Realistic Transmission and Distribution Co-Simulation for Voltage Control Benchmarking: Preprint

As distributed energy resources play an increasing role in generation and grid services, control and market paradigms will need to be tested with models that incorporate transmission and distribution systems. The test systems will need to be realistic and accessible for researchers to form conclusions about realistic behaviors and maintain comparability and repeatability of results. These test systems also must have high resolution models of sufficient size for realistic distribution and transmission interaction. This paper demonstrates the tightly coupled co-simulation of realistic synthetic distribution and transmission models for the Austin metropolitan area and how this framework can be used to analyze resultant behaviors from distributed resources and their controls. The comparison of a distribution system run with fixed feed-in voltage is compared to the closely tied distribution-transmission co-simulation. It is determined that even without advanced voltage controls, the feed-in voltage response of the transmission system shows a lower level of voltage excursions. Therefore, control methods for voltage stability should be benchmarked on realistic transmission and distribution co-simulations for more accurate assessment of voltage profiles.

27 ARPA - Advanced Research Projects Agency-Energy↗

Coordinated Optimization and Control of Residential Solid State Power Substations in Electrical Distribution Network

This paper proposes a computationally efficient mixed integer linear programming (MILP) model for the coordinated optimization of solid-state power substations (SSPSs) in a feeder considering the full unbalanced three-phase structure of the distribution grid and its characteristics. The proposed model determines the optimal real and reactive power of each SSPS at the point of common coupling (PCC) that minimizes the operating cost and maximizes the system performance, e.g., voltage regulation and phase balancing. To improve the computational efficiency, an inscribed octagon is introduced to approximate the quadratic capacity constraints of components. Numerical simulation results show the effectiveness of the proposed model and significant improvements in voltage profiles and power imbalance between phases.

Liu, Guodong↗

Soft Actor Critic Based Volt-VAR Co-optimization in Active Distribution Grids

Modern distribution networks are undergoing several technical challenges, such as voltage fluctuations, because of high penetration of distributed energy resources (DERs). This paper proposes a deep reinforcement learning (DRL)-based Volt VAR co-optimization technique for reducing voltage fluctuations as well as power loss under high penetration of DERs. In addition, the proposed approach minimizes the operational cost of the grid. A stochastic policy optimization based soft actor critic (SAC) agent is proposed to configure the optimal set-points of the reactive power outputs of the inverters. The performance of the proposed model is verified on the modified IEEE 34- and 123-bus systems and compared with a base case scenario with no reactive supply by inverters, and a local droop control approach. The results demonstrate that the proposed framework outperforms the conventional droop control method in improving the voltage profile, minimizing the network power loss, and reducing grid operational cost.

—Distribution grids, deep reinforcement learning, ↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Record >10 MV/cm mesa breakdown fields in Al 0.85 Ga 0.15 N/Al 0.6 Ga 0.4 N high electron mobility transistors on native AlN substrates

The ultra-wide bandgap of Al-rich AlGaN is expected to support a significantly larger breakdown field compared to GaN, but the reported performance thus far has been limited by the use of foreign substrates. In this Letter, the material and electrical properties of Al 0.85 Ga 0.15 N/Al 0.6 Ga 0.4 N high electron mobility transistors (HEMT) grown on a 2-in. single crystal AlN substrate are investigated, and it is demonstrated that native AlN substrates unlock the potential for Al-rich AlGaN to sustain large fields in such devices. We further study how Ohmic contacts made directly to a Si-doped channel layer reduce the knee voltage and increase the output current density. High-quality AlGaN growth is confirmed via scanning transmission electron microscopy, which also reveals the absence of metal penetration at the Ohmic contact interface and is in contrast to established GaN HEMT technology. Two-terminal mesa breakdown characteristics with 1.3 μm separation possess a record-high breakdown field strength of ~11.5 MV/cm for an undoped Al 0.6 Ga 0.4 N-channel layer. The breakdown voltages for three-terminal devices measured with gate-drain distances of 4 and 9 μm are 850 and 1500 V, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A parametric analysis of oilfield design factors affecting the detectability and characterization of electrically conductive hydrofracks

Electrical responses in the vicinity of energized steel-cased well sources offer significant potential for monitoring induced fractures. However, the high complexity of well-fracture-host models spanning multiple length scales compels analysts to simplify their numerical models due to enormous computational costs. This consequently limits our understanding regarding monitoring capabilities and the limitations of electrical measurements on realistic hydraulically fracturing systems. In this paper, we use the hierarchical finite element approach to construct geoelectric models in which geometrically complex fractures and steel-cased wells are discretely represented in 3D conducting media without sacrificing the model realism and computation efficiency. We have discovered systematic numerical analyses of the electrical responses to evaluate the influences of borehole material conductivity and the source type as well as the effects of well geometry, conductivity contrast, source location, fracture growth, and fracture propagation. Furthermore, the numerical results indicate that the borehole material property has a strong control on the electrical potentials along the production and monitoring wells. The monopole source located at a steel-cased well results in a current density distribution that decays away from the source location throughout the well length, whereas the dipole source produces a current density that dominates mainly along the dipole length. Moreover, the conductivity contrast between the fractures and host does not change the overall pattern of the electrical potentials but varies its amplitude. The fracture models near different well systems indicate that the well geometry controls the entire distribution of potentials, while the characteristics of the voltage difference profiles along the wells before and after fracturing are insensitive to the well geometry and the well in which the source is located. Further, the hydraulic-fracturing models indicate that the voltage differences along the production well before and after fracturing have strong sensitivity to fracture growth and fracture set propagation.

58 GEOSCIENCES↗

Interactive multiscale modeling to bridge atomic properties and electrochemical performance in Li-CO 2 battery design

Li-CO 2 batteries are promising energy storage systems due to their high theoretical energy density and CO 2 fixation capability, relying on reversible Li 2 CO 3 /C formation during discharge/charge cycles. Here, we present a multiscale modeling framework integrating Density Functional Theory (DFT), Ab-Initio Molecular Dynamics (AIMD), classical Molecular Dynamics (MD), and Finite Element Analysis (FEA) to investigate atomic and cell-level properties. The considered Li-CO 2 battery consists of a lithium metal anode, an ionic liquid electrolyte, and a carbon cloth cathode with Sb 0.67 Bi 1.33 Te 3 catalyst. DFT and AIMD determined the electrical conductivities of Sb 0.67 Bi 1.33 Te 3 and Li 2 CO 3 using the Kubo–Greenwood formalism and studied the CO 2 reduction mechanism on the cathode catalyst. MD simulations calculated the CO 2 diffusion coefficient, Li + transference number, ionic conductivity, and Li + solvation structure. The FEA model, parameterized with atomistic simulation data, reproduced the available experimental voltage–capacity profile at 1 mA/cm 2 and revealed spatio-temporal variations in Li 2 CO 3 /C deposition, porosity, and CO 2 concentration dependence on discharge rates in the cathode. Accordingly, Li 2 CO 3 can form large and thin film deposits, leading to dispersed and local porosity changes at 0.1 mA/cm 2 and 1 mA/cm 2 , respectively. The capacity decreases exponentially from 81,570 mAh/g at 0.1 mA/cm 2 to 6200 mAh/g at 1 mA/cm 2 , due to pore clogging from excessive discharge product deposition that limits CO 2 transport to the cathode interior. Therefore, the performance of Li-CO 2 batteries can be improved by enhancing CO 2 transport, regulating Li 2 CO 3 deposition, and optimizing cathode architecture.

Battery performance↗

Thermal and radiation response of 4H–SiC Schottky diodes with direct-write electrical contacts

In this work, a high-sensitivity 4H–SiC temperature sensor and an alpha detector have been fabricated using additively printed metal contacts. The surface morphology and electrical conductivity of the printed electrodes were established prior to Schottky diode development. 4H–SiC Schottky diodes with direct-write printed silver contacts on the 5 μ m-thick epilayer on 4H–SiC were characterized electrically in terms of the forward and reverse current–voltage and high-frequency capacitance–voltage characteristics. Furthermore, the turn-on voltage of the Schottky diodes, as established from the forward current–voltage characteristics measured up to a temperature of 400 °C, showed a linear temperature dependence. Schottky diodes with direct-write printed Ag electrodes were able to measure alpha particles emitted from Americium-241. The high temperature and radiation response of the Schottky diodes show their suitability for multi-modal sensor fusion on the 4H–SiC platform for harsh environment applications.

42 ENGINEERING↗