Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Visualization of Jet Impingement and Ignition in a Piston-Cylinder Chamber

The transportation sector accounts for almost a third of the United States' energy consumption. We are developing predictive simulations of the complex in-cylinder processes of internal combustion engines to improve performance and decrease pollutant emissions. We provide a first look at the jet impingement and ignition inside a piston-cylinder chamber using volume rendering. Through the visualization, we constructed a complete 3D picture of the jet impingement on the piston-bowl walls leading to the formation of pockets of auto-ignition of the fuel-air mixture. These auto-ignition pockets subsequently lead to flame stabilization, releasing the chemical energy for conversion to useful work. A detailed physical picture of flame stabilization, as provided by the visualization techniques presented in this study, help in the design of next-generation internal combustion engines.

91 SC - Advanced Scientific Computing Reseach (ASC↗

Volume-conserving trans-cis isomerization pathways in photoactive yellow protein visualized by picosecond X-ray crystallography

Trans-to-cis isomerization, the key reaction in photoactive proteins, usually cannot occur through the standard one-bond-flip mechanism. Owing to spatial constraints imposed by a protein environment, isomerization probably proceeds through a volume-conserving mechanism in which highly choreographed atomic motions are expected, the details of which have not yet been observed directly. Here we employ time-resolved X-ray crystallography to visualize structurally the isomerization of the p-coumaric acid chromophore in photoactive yellow protein with a time resolution of 100 ps and a spatial resolution of 1.6 Å. The structure of the earliest intermediate (I T ) resembles a highly strained transition state in which the torsion angle is located halfway between the trans- and cis-isomers. The reaction trajectory of IT bifurcates into two structurally distinct cis intermediates via hula-twist and bicycle-pedal pathways. The bifurcating reaction pathways can be controlled by weakening the hydrogen bond between the chromophore and an adjacent residue through E46Q mutation, which switches off the bicycle-pedal pathway.

Jung, Yang Ouk↗

SU-E-J-196: New Visualization Methods for Longitudinal MRI Registrations and Segmentations

Purpose: To develop visualization techniques to facilitate easy assessment of (a) registration and (b) tracking volumetric changes in structures during radiation therapy from MRI. Method: The frequently used method for visualizing registrations between scans is a multi-color overlay technique or deformation vector fields. However, the overlay technique is unintuitive and does not help to appreciate the quality of registration particularly when the registration mismatches are not very large. Similarly, the deformation fields give an indication of extent of deformation but do not help to assess the differences in registration. We present a mirroring and edge-augmented mirroring technique that places the fixed and moving image next to each other and allows the user to quickly assess the small differences in registration. Next, we present a volumetric intersection based 3D model to visualize the changes in diseased lymph node volumes in head and neck cancer. 3D model-based visualization provides more information about the location-specific changes in volume rather than the simplistic one dimensional information obtained from 2D plot of nodal volume changes. Result: We show results comparing our approach with the standard colorbased overlay method for comparing registrations of intra-patient registrations using T2-MRI. Upon comparing the mirroring technique with the color-overlay, one can more easily appreciate the differences in registration. Adding edge-based mirroring seems to further assist in evaluating the registration. Our approach for viewing registrations seems to be more intuitive and easy to use in order to help assess the quality of registration compared to color-based overlays. Similarly, the change volumetric model together with a 2D plot reveals more information including the locations undergoing changes and responding to treatment. Conclusions: Better approaches are necessary for assessing the quality of registrations and changes in diseased structures over time. Our approach presents some novel visualization solutions for registration and segmentation.

60 APPLIED LIFE SCIENCES↗

Fiber Uncertainty Visualization for Bivariate Data With Parametric and Nonparametric Noise Models

Visualization and analysis of multivariate data and their uncertainty are top research challenges in data visualization. Constructing fiber surfaces is a popular technique for multivariate data visualization that generalizes the idea of level-set visualization for univariate data to multivariate data. Here, in this paper, we present a statistical framework to quantify positional probabilities of fibers extracted from uncertain bivariate fields. Specifically, we extend the state-of-the-art Gaussian models of uncertainty for bivariate data to other parametric distributions (e.g., uniform and Epanechnikov) and more general nonparametric probability distributions (e.g., histograms and kernel density estimation) and derive corresponding spatial probabilities of fibers. In our proposed framework, we leverage Green's theorem for closed-form computation of fiber probabilities when bivariate data are assumed to have independent parametric and nonparametric noise. Additionally, we present a nonparametric approach combined with numerical integration to study the positional probability of fibers when bivariate data are assumed to have correlated noise. For uncertainty analysis, we visualize the derived probability volumes for fibers via volume rendering and extracting level sets based on probability thresholds. We present the utility of our proposed techniques via experiments on synthetic and simulation datasets.

97 MATHEMATICS AND COMPUTING↗

3D Stereoscopic Visualization of Fenestrated Stent Grafts

The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MPI-hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

This work studies the performance and scalability characteristics of"hybrid'" parallel programming and execution as applied to raycasting volume rendering -- a staple visualization algorithm -- on a large, multi-core platform. Historically, the Message Passing Interface (MPI) has become the de-facto standard for parallel programming and execution on modern parallel systems. As the computing industry trends towards multi-core processors, with four- and six-core chips common today and 128-core chips coming soon, we wish to better understand how algorithmic and parallel programming choices impact performance and scalability on large, distributed-memory multi-core systems. Our findings indicate that the hybrid-parallel implementation, at levels of concurrency ranging from 1,728 to 216,000, performs better, uses a smaller absolute memory footprint, and consumes less communication bandwidth than the traditional, MPI-only implementation.

97 MATHEMATICS AND COMPUTING↗

A 2.5d Yolo-Based Fusion Algorithm for 3d Localization Of Cells

Advances in microscopy techniques such as lattice-light-sheet, confocal, two-photon, and electron microscopy have enabled the visualization of 3D image volumes of tightly packed cells, extracellular structures in tissues, organelles, and subcellular components inside cells. These images sampled by 2D projections are often not accurately interpreted even by human experts. As a use case we focus on 3D image volumes of tightly packed nuclei in brain tissue. Due to out-of-plane excitation and low resolution in the z-axis, non-overlapping cells appear as overlapping 3D volumes and make detecting individual cells challenging. On the other hand, running 3D detection algorithms is computationally expensive and infeasible for large datasets. In addition, most existing 3D algorithms are designed to extract 3D objects by identifying the depth in the 2D images. In this work, we propose a YOLO-based 2.5D fusion algorithm for 3D localization of individual cells in densely packed volumes of nuclei. The proposed method fuses 2D detection of nuclei in sagittal, coronal, and axial planes and predicts six coordinates of the 3D bounding cubes around the detected 3D cells. Promising results were obtained on multiple examples of synthetic dense volumes of nuclei imitating confocal microscopy experimental datasets.

Ziabari, Amir↗

WE-A-BRD-00: MR Basics II

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-01: MR Imaging for Treatment Planning: What Every Physicist Should Know

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

Improving Scientific Data Analysis Through Multi-touch Enabled Interactive Data Visualization with Applications to Neutron Science

Scientific data analysis is an inherently exploratory process that requires flexible human interaction with data visualization and anal- ysis tools. In this paper, we describe challenges in neutron scattering data analysis and present our approach for allowing more effective human interaction. In addition to multi-touch enabled data visualiza- tion techniques, we describe color scale enhancements, layouts, and visual analytics approaches for 3D volume slicing. Since challenges in neutron science are echoed in most scientific fields, we generalize the project objective and present a case for bridging the gap between the latest advances in interactive data visualization and practical scientific scenarios where new critical knowledge is buried in large volumes of complex data.

Steed, Chad↗

Radiation Dose–Dependent Hippocampal Atrophy Detected With Longitudinal Volumetric Magnetic Resonance Imaging

Purpose: After radiation therapy (RT) to the brain, patients often experience memory impairment, which may be partially mediated by damage to the hippocampus. Hippocampal sparing in RT planning is the subject of recent and ongoing clinical trials. Calculating appropriate hippocampal dose constraints would be improved by efficient in vivo measurements of hippocampal damage. In this study we sought to determine whether brain RT was associated with dose-dependent hippocampal atrophy. Methods and Materials: Hippocampal volume was measured with magnetic resonance imaging (MRI) in 52 patients who underwent fractionated, partial brain RT for primary brain tumors. Study patients had high-resolution, 3-dimensional volumetric MRI before and 1 year after RT. Images were processed using software with clearance from the US Food and Drug Administration and Conformité Européene marking for automated measurement of hippocampal volume. Automated results were inspected visually for accuracy. Tumor and surgical changes were censored. Mean hippocampal dose was tested for correlation with hippocampal atrophy 1 year after RT. Average hippocampal volume change was also calculated for hippocampi receiving high (>40 Gy) or low (<10 Gy) mean RT dose. A multivariate analysis was conducted with linear mixed-effects modeling to evaluate other potential predictors of hippocampal volume change, including patient (random effect), age, hemisphere, sex, seizure history, and baseline volume. Statistical significance was evaluated at α = 0.05. Results: Mean hippocampal dose was significantly correlated with hippocampal volume loss (r=−0.24, P=.03). Mean hippocampal volume was significantly reduced 1 year after high-dose RT (mean −6%, P=.009) but not after low-dose RT. In multivariate analysis, both RT dose and patient age were significant predictors of hippocampal atrophy (P<.01). Conclusions: The hippocampus demonstrates radiation dose–dependent atrophy after treatment for brain tumors. Quantitative MRI is a noninvasive imaging technique capable of measuring radiation effects on intracranial structures. This technique could be investigated as a potential biomarker for development of reliable dose constraints for improved cognitive outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Multilinear Tensor Product Wavelets

Many foundational visualization techniques including isosurfacing, direct volume rendering and texture mapping rely on piecewise multilinear interpolation over the cells of a mesh. However, there has not been much focus within the visualization community on techniques that efficiently generate and encode globally continuous functions defined by the union of multilinear cells. Wavelets provide a rich context for analyzing and processing complicated datasets. In this paper, we exploit adaptive regular refinement as a means of representing and evaluating functions described by a subset of their nonzero wavelet coefficients. We analyze the dependencies involved in the wavelet transform and describe how to generate and represent the coarsest adaptive mesh with nodal function values such that the inverse wavelet transform is exactly reproduced via simple interpolation (subdivision) over the mesh elements. This allows for an adaptive, sparse representation of the function with on-demand evaluation at any point in the domain. In conclusion, we focus on the popular wavelets formed by tensor products of linear B-splines, resulting in an adaptive, nonconforming but crack-free quadtree (2D) or octree (3D) mesh that allows reproducing globally continuous functions via multilinear interpolation over its cells.

97 MATHEMATICS AND COMPUTING↗

A VR-based volumetric medical image segmentation and visualization system with natural human interaction

Volume rendering produces informative two-dimensional (2D) images from a 3-dimensional (3D) volume. It highlights the region of interest and facilitates a good comprehension of the entire data set. However, volume rendering faces a few challenges. First, a high-dimensional transfer function is usually required to differentiate the target from its neighboring objects with subtle variance. Unfortunately, designing such a transfer function is a strenuously trial-and-error process. Second, manipulating/visualizing a 3D volume with a traditional 2D input/output device suffers dimensional limitations. To address all the challenges, we design NUI-VR 2 , a natural user interface-enabled volume rendering system in the virtual reality space. NUI-VR 2 marries volume rendering and interactive image segmentation. It transforms the original volume into a probability map with image segmentation. A simple linear transfer function will highlight the target well in the probability map. More importantly, we set the entire image segmentation and volume rendering pipeline in an immersive virtual reality environment with a natural user interface. NUI-VR 2 eliminates the dimensional limitations in manipulating and perceiving 3D volumes and dramatically improves the user experience.

42 ENGINEERING↗

VISMASHUP: streamlining the creation of custom visualization applications

Visualization is essential for understanding the increasing volumes of digital data. However, the process required to create insightful visualizations is involved and time consuming. Although several visualization tools are available, including tools with sophisticated visual interfaces, they are out of reach for users who have little or no knowledge of visualization techniques and/or who do not have programming expertise. In this paper, we propose VISMASHUP, a new framework for streamlining the creation of customized visualization applications. Because these applications can be customized for very specific tasks, they can hide much of the complexity in a visualization specification and make it easier for users to explore visualizations by manipulating a small set of parameters. We describe the framework and how it supports the various tasks a designer needs to carry out to develop an application, from mining and exploring a set of visualization specifications (pipelines), to the creation of simplified views of the pipelines, and the automatic generation of the application and its interface. We also describe the implementation of the system and demonstrate its use in two real application scenarios.

97 MATHEMATICS AND COMPUTING↗

Visualization of electronic density

An atom’s volume depends on its electronic density. Although this density can only be evaluated exactly for hydrogen-like atoms, there are many excellent numerical algorithms and packages to calculate it for other materials. 3D visualization of charge density is challenging, especially when several molecular/atomic levels are intertwined in space. We explore several approaches to 3D charge density visualization, including the extension of an anaglyphic stereo visualization application based on the AViz package to larger structures such as nanotubes. We will describe motivations and potential applications of these tools for answering interesting questions about nanotube properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Prospective Randomized Double-Blind Pilot Study of Site-Specific Consensus Atlas Implementation for Rectal Cancer Target Volume Delineation in the Cooperative Group Setting

Purpose: Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. Methods and Materials: A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). Results: Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. Conclusion: Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Query and Visualization of extremely large network datasets over the web using Quadtree based KML Regional Network Links

Geographic data sets are often very large in size. Interactive visualization of such data at all scales is not easy because of the limited resolution of the monitors and inability of visualization applications to handle the volume of data. This is especially true for large vector datasets. The end user s experience is frequently unsatisfactory when exploring such data over the web using a naive application. Network bandwidth is another contributing factor to the low performance. In this paper, a Quadtree based technique to visualize extremely large spatial network datasets over the web is described. It involves using custom developed algorithms leveraging a PostGIS database as the data source and Google Earth as the visualization client. This methodology supports both point and range queries along with non-spatial queries. This methodology is demonstrated using a network dataset consisting of several million links. The methodology is based on using some of the powerful features of KML (Keyhole Markup Language). Keyhole Markup Language (KML) is an Open Geospatial Consortium (OGC) standard for displaying geospatial data on Earth browsers. One of the features of KML is the notion of Network Links. Using network links, a wide range of geospatial data sources such as geodatabases, static files and geospatial data services can be simultaneously accessed and visualized seamlessly. Using the network links combined with Level of Detail principle, view based rendering and intelligent server and client-side caching, scalability in visualizing extremely large spatial datasets can be achieved.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗