Search NASA⌕ Search

SEARCH · Search NASA

Results for “water vapor continuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

85 records · Page 5

Airborne photometric observations between 1.25 and 3.25 microns of late-type stars

The stars Alpha Aur (G5 III + G0 III), Alpha Boo (K2 IIIp), Alpha Ori (M1-M2 Ia-Ib), Alpha Sco (M1.5 Iab), Mu Gem (M3 III), and Alpha Her (M5 Ib-II) have been observed using interference filters in five photometric bands between 1.25 and 3.25 microns during seven flights with NASA's Lear Jet Infrared Observatory. The filters were designed to measure molecular features, primarily from CN and CO, and continuum fluxes. By calibrating the photometer in the laboratory against a stabilized blackbody source, relative flux curves have been derived. The energy distributions and the strength of molecular features are discussed. The most interesting result obtained is that the fluxes from Mu Gem and Alpha Her in the filter centered at 3.25 microns seem to be depressed by at least some tenths of a magnitude. Tentatively this depression is proposed to be due to the wings of the two vibration-rotation bands (about 2.7 microns) of hot water vapor. Since water vapor is an important opacity source and its abundance is a sensitive C/O indicator, the proposed interpretation makes renewed efforts to detect water bands in early M stars highly desirable.

Nordh, H. L.↗

Water vapor absorption coefficients in the 8-13-micron spectral region - A critical review

Measurements of water vapor absorption coefficients in the thermal IR atmospheric window (8-13 microns) during the past 20 years obtained by a variety of techniques are reviewed for consistency and compared with computed values based on the AFGL spectral data tapes. The methods of data collection considered were atmospheric long path absorption with a CO2 laser or a broadband source and filters, a White cell and a CO2 laser or a broadband source and a spectrometer, and a spectrophone with a CO2 laser. Advantages and disadvantages of each measurement approach are given as a guide to further research. Continuum absorption has apparently been measured accurately to about the 5-10 percent level in five of the measurements reported.

Grant, William B.↗

Infrared Signature Masking by Air Plasma Radiation

This report describes progress during the second year of our research program on Infrared Signature Masking by Air Plasmas at Stanford University. This program is intended to investigate the masking of infrared signatures by the air plasma formed behind the bow shock of high velocity missiles. Our previous annual report described spectral measurements and modeling of the radiation emitted between 3.2 and 5.5 microns by an atmospheric pressure air plasma in chemical and thermal equilibrium at a temperature of approximately 3100 K. One of our goals was to examine the spectral emission of secondary species such as water vapor or carbon dioxide. The cold air stream injected in the plasma torch contained approximately 330 parts per million Of CO2, which is the natural CO2 concentration in atmospheric air at room temperature, and a small amount of water vapor with an estimated mole fraction of 3.8 x 10(exp -4). As can be seen from Figure 1, it was found that the measured spectrum exhibited intense spectral features due to the fundamental rovibrational bands of NO at 4.9 - 5.5 microns and the V(3) band of CO2 (antisymmetric stretch) at 4.2-4.8 microns. These observations confirmed the well-known fact that infrared signatures between 4.15 - 5.5 microns can be masked by radiative emission in the interceptor's bow-shock. Figure I also suggested that the range 3.2 - 4.15 microns did not contain any significant emission features (lines or continuum) that could mask IR signatures. However, the signal-to-noise level, close to one in that range, precluded definite conclusions. Thus, in an effort to further investigate the spectral emission in the range of interest to signature masking problem, new measurements were made with a higher signal-to-noise ratio and an extended wavelength range.

Kruger, C. H.↗

High-Fidelity Arc-Discharge Model for Hydrogen-Plasma-Smelting-Reduction of Iron Ore

Electrification and use of renewable hydrogen is currently a necessity for decarbonizing the iron-and-steel industry. In this regard, hydrogen plasma smelting reduction (HPSR) is a novel pathway that is being explored for reduction of iron ore. HPSR provides several decarbonization merits compared to conventional blast furnaces. Firstly, the use of renewable hydrogen drastically reduces the CO2 emissions compared to the use of coke. Secondly, renewable electricity in the form of a thermal plasma for making reactive hydrogen species (radicals, ions) are more efficient at reducing iron ore compared to neutral H2. Thirdly, a molten product compatible with downstream processes is obtained from the intense heat transfer from the plasma. However, the scale-up of this technology requires fundamental exploration of hydrogen plasma dynamics and its interaction with complex solid material that include phase changing iron-ore and slag. In this work, we present a first principles continuum scale model for thermal plasmas in Ar/H2 gas mixtures typically used for HPSR. The thermal plasma governing equations for mass, momentum and energy with Lorentz force and Joule heating source terms are solved along with electromagnetic equations for electrostatic and magnetic vector potential. Our solver will be based on Pele, a suite of reacting flow solvers designed for advanced scientific computing architectures (Henry De Frahan et al., Proceedings of SIAM Parallel Processing, 13-25, 2024), and will utilize adaptive mesh generation for enhanced resolutions at locations of intense physicochemical interactions. This study will present the impact of Ar to H2 ratios on excited/dissociated hydrogen species concentrations, plasma temperature and conductivity along with the impact of outgassed species (water, metal vapor, O, OH radicals) from ore surface on gas phase chemistry. Furthermore, the heat and species flux to the surface will be quantified as a function of applied voltages in a transferred arc configuration.

hydrogen plasma↗

Dynamic changes in evapotranspiration, canopy photosynthesis and expansive growth in open field under rapid fluctuating radiation

Abstract In open fields, plants experience dynamic changes in environment, particularly radiation, temperature, wind, and humidity but their short-term responses have not been adequately characterized under natural conditions. In this study, we assessed causal effects of rapid radiation fluctuation on seven plant parameters in open fields of cotton and sweet corn canopies. The parameters are evapotranspiration ( ET ), canopy photosynthesis indicated by CO2 flux from air to canopy ( FCO2 ), sensible heat energy flux ( H ), canopy conductance for water vapor ( gcw ), canopy surface temperature ( Ts ), shoot and leaf elongation rate, and stem diameter change. The energy and CO2 fluxes were measured with Bowen ratio/energy balance/CO2 gradient (BREB+) technique, using averaging time of 5 min. Shoot + leaf elongation and stem diameter change were monitored with position transducers using averaging time of 1 min. All parameters were all found to respond to change in radiation and transpiration within minutes or sooner. While radiation effects on canopy gas exchanges are expected, illuminating are the indirect but immediate effects on shoot + leaf growth and stem diameter change through radiation effects on transpiration and plant water status. A novel finding is that gcw also responded within minutes or sooner to radiation fluctuations and that FCO2 was related almost linearly to gcw . Results are discussed in terms of soil-plant-atmosphere continuum, and interpreted in terms of dynamic interactions between transpiration and plant water status. The clear inverse relationship between ET and elongation rate or stem diameter changes provides additional evidence supporting the validity of 5-min averaging for the BREB + technique.

Hsiao, Theodore C.↗

Intense cavitation-assisted electric discharge as a promising tool for water treatment

This study investigates interrelations between one-electrode Cavitation-Assisted Electric Discharge (CAED), two-electrode CAED, and recently discovered Intense CAED (I-CAED). The one-electrode CAED is a self-triggered nanosecond discharge with pulse energy in the micro-Joule range, which can be generated even by a DC voltage. I-CAED consists of a non-equilibrium part within a low-pressure cavitating region and a micro-spark traversing a liquid film. We hypothesize that CAED propagates from the high-voltage electrode as an ionization wave through bubbles of saturated vapor. Subsequently, the streamer-like discharges in the bubbles may form a continuous plasma channel. Inside the cavitating region, the plasma is strongly non-equilibrium, providing an ideal environment for generating chemically unstable species such as hydrogen peroxide (H 2 O 2 ). Plasma of I-CAED spark is characterized by high electron density and near-thermal equilibrium, emitting a continuous ultraviolet spectrum. The combination of these different discharge parts makes I-CAED in water a highly effective tool for the Advanced Oxidation Process, particularly in water disinfection. Experimentally demonstrated Electric Energy per Order value for disinfection of E. coli-contaminated water is as low as 0.135 ± 0.035 kWh/m 3 /order. Estimates show that the implementation of “dry electrodes” configuration reduces the erosion rate of the electrode material by at least one order of magnitude. Spectral analysis reveals that the continuum emission generated by I-CAED in proximity to metal electrodes deviates from the spectra of discharges spatially decoupled from the electrodes. We assume that this spectral divergence is attributable to blackbody-like emission originating from metallic nanoparticles form during the electrode's erosion process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Impact Crater Origin for the InSight Landing Site at Homestead Hollow, Mars: Implications for Near Surface Stratigraphy, Surface Processes, and Erosion Rates

The InSight mission to Mars landed within Homestead hollow on an Early Amazonian lavaplain. The hollow is a 27‐m‐diameter, 0.3‐m‐deep quasi‐circular depression that shares morphologic and sedimentologic characteristics to degraded impact craters. Unlike the intercrater plains outside of the hollow, the interior lacks cobbles and is dominated by loose sand, granules, and pebbles. Fresher craters near the landing site exhibit meter‐scale bedforms in their ejecta and on their floors due to sediment trapping.The sedimentology of the interior fill of Homestead hollow suggests similar trapping. The hollow falls along amorphologic continuum that requires low rates of rim degradation and fill. Crater degradation rates (rim erosion plus filling) in the landing site decline nonlinearly through time from 10−2to 10−4m/Myr as craters evolve to a hollow‐like form. Rim erosion rates are lower initially, at 10−3m/Myr, but converge with degradation rates to 10−4m/Myr. This implies that while filling plays an important role soon after crater formation, it is limited in later stages. Crater statistics indicate that the bulk of the fill occurred in the first~50 Myr for Homestead hollow. The estimated maximum age of the hollow is ~400 to 700 Myr. This requires near‐zero fill aggradation and long‐term soil stability for the bulk of the crater's history. Fill stability manifests in Homestead hollow as a ~5‐to 10‐cm‐thick duricrust, formed by exchanges of atmospheric water vapor with soil. The estimated degradation in the hollow requires ~2 to 3 m of sedimentary fill beneath the lander.

Maria Elaine Banks↗

Linking Synoptic Patterns to Cloud Properties and Local Circulations Over Southeastern Texas

This report classifies meteorological regimes in the southeastern Texas region to identify environmental conditions that favor sea-breeze induced convection. The classification is accomplished using a Self-Organizing Map (SOM) approach. We applied SOM to 10 years of 700-hPa geopotential height anomalies during the summer months from reanalysis data to distinguish three dominant synoptic regimes, with a continuum of transitional states between those. The primary regimes include: (a) a pre-trough regime associated with a synoptic trough, (b) a post-trough regime with upper-level northerly flow, and (c) an anticyclonic regime within the westward extent of the Bermuda High. We project the data from the Geostationary Operational Environmental Satellite and the Next Generation Weather Radar system onto each SOM node to investigate the characteristics of cloud and precipitation properties in different regimes. When southeastern Texas is positioned to the southwest quadrant of a maritime high pressure system, an increased cloud frequency is observed over the region during the afternoon hours due to significant moisture advection. A confluence of synoptic southerly flow and sea-breeze circulation commonly occurs in this regime. When a high pressure system is over southeastern Texas, the area is dominated by large-scale subsidence with weak pressure gradients and moderate precipitable water vapor. This weak synoptic forcing is favorable for the formation of a sea-breeze circulation. This is confirmed by an enhanced onshore flow and a decreased temperature at the surface in the early afternoon, as well as a sharp increase in radar echo top height.

54 ENVIRONMENTAL SCIENCES↗

Heterodyne detection of the 752.033-GHz H2O rotational absorption line

A tunable high resolution two stage heterodyne radiometer was developed for the purpose of investigating the intensity and lineshape of the 752.033 GHz rotational transition of water vapor. Single-sideband system noise temperatures of approximately 45,000 K were obtained using a sensitive GaAs Schottky diode as the first stage mixer. First local oscillator power was supplied by a CO2 laser pumped formic acid laser (761.61 GHz), generating an X-band IF signal with theoretical line center at 9.5744 GHz. Second local oscillator power was provided by means of a 3 GHz waveguide cavity filter with only 9 dB insertion loss. In absorption measurements of the H2O taken from a laboratory simulation of a high altitude rocket plume, the center frequency of the 752 GHz line was determined to within 1 MHz of the reported value. A rotational temperature 75 K, a linewidth 5 MHz and a Doppler shift 3 MHz were measured with the line-of-sight intersecting the simulated-plume axis at a distance downstream of 30 nozzle diameters. These absorption data were obtained against continuum background radiation sources at temperatures of 1175 and 300 K.

Dionne, G. F.↗

An Intercomparison of Radiation Codes for Retrieving Upper Tropospheric Humidity in the 6.3-micron Band: A Report from the 1st GVaP Workshop

An intercomparison of radiation codes used in retrieving upper tropospheric humidity (UTH) from observations in the v2 (6.3 microns) water vapor absorption band was performed. This intercomparison is one part of a coordinated effort within the GEWEX Water Vapor Project (GVaP) to assess our ability to monitor the distribution and variations of upper tropospheric moisture from space-borne sensors. A total of 23 different codes, ranging from detailed line-by-line (LBL) models, to coarser resolution narrow-band (NB) models, to highly-parameterized single-band (SB) models participated in the study. Forward calculations were performed using a carefully selected set of temperature and moisture profiles chosen to be representative of a wide range of atmospheric conditions. The LBL model calculations exhibited the greatest consistency with each other, typically agreeing to within 0.5 K in terms of the equivalent blackbody brightness temperature (T(sub b)). The majority of NB and SB models agreed to within +/- 1 K of the LBL models, although a few older models exhibited systematic T(sub b) biases in excess of 2 K. A discussion of the discrepancies between various models, their association with differences in model physics (e.g. continuum absorption), and their implications for UTH retrieval and radiance assimilation is presented.

Soden, B.↗

Viewpoint 9--molecular structure of aqueous interfaces

In this review we summarize recent progress in our understanding of the structure of aqueous interfaces emerging from molecular level computer simulations. It is emphasized that the presence of the interface induces specific structural effects which, in turn, influence a wide variety of phenomena occurring near the phase boundaries. At the liquid-vapor interface, the most probable orientations of a water molecule is such that its dipole moment lies parallel to the interface, one O-H bond points toward the vapor and the other O-H bond is directed toward the liquid. The orientational distributions are broad and slightly asymmetric, resulting in an excess dipole moment pointing toward the liquid. These structural preferences persist at interfaces between water and nonpolar liquids, indicating that the interactions between the two liquids in contact are weak. It was found that liquid-liquid interfaces are locally sharp but broadened by capillary waves. One consequence of anisotropic orientations of interfacial water molecules is asymmetric interactions, with respect to the sign of the charge, of ions with the water surface. It was found that even very close to the surface ions retain their hydration shells. New features of aqueous interfaces have been revealed in studies of water-membrane and water-monolayer systems. In particular, water molecules are strongly oriented by the polar head groups of the amphiphilic phase, and they penetrate the hydrophilic head-group region, but not the hydrophobic core. At infinite dilution near interfaces, amphiphilic molecules exhibit behavior different from that in the gas phase or in bulk water. This result sheds new light on the nature of hydrophobic effect in the interfacial regions. The presence of interfaces was also shown to affect both equilibrium and dynamic components of rates of chemical reactions. Applications of continuum models to interfacial problems have been, so far, unsuccessful. This, again, underscores the importance of molecular-level information about interfaces.

Review, Tutorial↗

A Multi-Scale Sampling Strategy for Detecting Physiologically Significant Signals in AVIRIS Imagery

Models of photosynthetic production at ecosystem and global scales require multiple input parameters specifying physical and physiological surface features. While certain physical parameters (e.g., absorbed photosynthetically active radiation) can be derived from current satellite sensors, other physiologically relevant measures (e.g., vegetation type, water status, carboxylation capacity, or photosynthetic light-use efficiency), are not generally directly available from current satellite sensors at the appropriate geographic scale. Consequently, many model parameters must be assumed or derived from independent sources, often at an inappropriate scale. An abundance of ecophysiological studies at the leaf and canopy scales suggests strong physiological control of vegetation-atmosphere CO2 and water vapor fluxes, particularly in evergreen vegetation subjected to diurnal or seasonal stresses. For example hot, dry conditions can lead to stomatal closure, and associated "downregulation" of photosynthetic biochemical processes, a phenomenon often manifested as a "midday photosynthetic depression". A recent study with the revised simple biosphere (SiB2) model demonstrated that photosynthetic downregulation can significantly impact global climate. However, at the global scale, the exact significance of downregulation remains unclear, largely because appropriate physiological measures are generally unavailable at this scale. Clearly, there is a need to develop reliable ways of extracting physiologically relevant information from remote sensing. Narrow-band spectrometers offer many opportunities for deriving physiological parameters needed for ecosystem and global scale photosynthetic models. Experimental studies on the ground at the leaf- to stand-scale have indicated that several narrow-band features can be used to detect plant physiological status. One physiological signal is caused by xanthophyll cycle pigment activity, and is often expressed as the Photochemical Reflectance Index (PRI). Because the xanthophyll cycle pigments are photoregulatory pigments closely linked to photosynthetic function, this index can be used to derive relative photosynthetic rates. An additional signal with physiological significance is the 970 nm water absorption band, which provides a measure of liquid water content. This feature has been quantified both using a simple 2-band ratio (900/970 nm, here referred to as the "Water Band Index" or WBI;), and using the "continuum removal" method. Current atmospheric correction methods for AVIRIS imagery also obtain quantitative expressions of surface liquid water absorption based on the 970 nm water band and may be comparable to ground-based estimates of water content using this feature. However, physiological interpretations of both the PRI and the WBI are best understood at the leaf and canopy scales, where complications of atmospheric interference and complex stand and landscape features can be minimized, and where experimental manipulations can be readily applied. Currently it is not known whether these physiological indices can be used to derive meaningful physiological information from AVIRIS imagery. In addition to the problem of atmospheric interference, another challenge is that any simple physiological index can be confounded by multiple factors unrelated to physiology, and this problem can become more severe at progressively larger spatial scales. For example, previous work has suggested that both the PRI and the WBI, are strongly correlated with other optical measures of canopy structure (e.g., the Normalized Difference Vegetation Index or green vegetation fraction), indicating a confounding effect of structure on physiological signals at the larger, landscape scale. Furthermore, the normal operating mode of most imaging spectrometers does not allow simultaneous, ground truthing at a level of detail needed for physiological sampling. Additionally, manipulative experiments of physiology are difficult to apply at a geographic scale suitable for comparison with remote imagery, which often works at spatial scales that are several orders of magnitude larger than those typically used for physiological studies. These limitations require the consideration of alternative approaches to validating physiological information derived from AVIRIS data. In this report, we present a multi-scale sampling approach to detecting physiologically significant signals in narrow-band spectra. This approach explores the multi-dimensional data space provided by narrow-band spectrometry, and combines AVIRIS imagery at a large scale, with ground spectral sampling at an intermediate scale, and detailed ecophysiological measurements at a fine scale, to examine seasonally and spatially changing relationships between multiple structural and physiological variables. Examples of this approach are provided by simultaneous sampling of the Normalized Difference Vegetation Index (NDVI), an index of fractional PAR interception and green vegetation cover, the Water Band Index (WBI, an index of liquid water absorption, and the Photochemical Reflectance Index (PRI, an index of xanthophyll cycle pigment activity and photosynthetic light-use efficiency. By directly linking changing optical properties sampled on the ground with measurable physiological states, we hope to develop a basis for interpreting similar signals in AVIRIS imagery.

Gamon, John A.↗

Motion of Drops on Surfaces with Wettability Gradients

A liquid drop present on a solid surface can move because of a gradient in wettability along the surface, as manifested by a gradient in the contact angle. The contact angle at a given point on the contact line between a solid and a liquid in a gaseous medium is the angle between the tangent planes to the liquid and the solid surfaces at that point and is measured within the liquid side, by convention. The motion of the drop occurs in the direction of increasing wettability. The cause of the motion is the net force exerted on the drop by the solid surface because of the variation of the contact angle around the periphery. This force causes acceleration of an initially stationary drop, and leads to its motion in the direction of decreasing contact angle. The nature of the motion is determined by the balance between the motivating force and the resisting hydrodynamic force from the solid surface and the surrounding gaseous medium. A wettability gradient can be chemically induced as shown by Chaudhury and Whitesides who provided unambiguous experimental evidence that drops can move in such gradients. The phenomenon can be important in heat transfer applications in low gravity, such as when condensation occurs on a surface. Daniel et al have demonstrated that the velocity of a drop on a surface due to a wettability gradient in the presence of condensation can be more than two orders of magnitude larger than that observed in the absence of condensation. In the present research program, we have begun to study the motion of a drop in a wettability gradient systematically using a model system. Our initial efforts will be restricted to a system in which no condensation occurs. The experiments are performed as follows. First, a rectangular strip of approximate dimensions 10 x 20 mm is cut out of a silicon wafer. The strip is cleaned thoroughly and its surface is exposed to the vapor from an alkylchlorosilane for a period lasting between one and two minutes inside a desiccator. This is done using an approximate line source of the vapor in the form of a string soaked in the alkylchlorosilane. Ordinarily, many fluids, including water, wet the surface of silicon quite well. This means that the contact angle is small. But the silanized surface resists wetting, with contact angles that are as large as 100 degs. Therefore, a gradient of wettability is formed on the silicon surface. The region near the string is highly hydrophobic, and the contact angle decreases gradually toward a small value at the hydrophilic end away from this region. The change in wettability occurs over a distance of several mm. The strip is placed on a platform within a Plexiglas cell. Drops of a suitable liquid are introduced on top of the strip near the hydrophobic end. An optical system attached to a video camera is trained on the drop so that images of the moving drop can be captured on videotape for subsequent analysis. We have performed preliminary experiments with water as well as ethylene glycol drops. Results from these experiments will be presented in the poster. Future plans include the refinement of the experimental system so as to permit images to be recorded from the side as well as the top, and the conduct of a systematic study in which the drop size is varied over a good range. Experiments will be conducted with different fluids so as to obtain the largest possible range of suitably defined Reynolds and Capillary numbers. Also, an effort will be initiated on theoretical modeling of this motion. The challenges in the development of the theoretical description lie in the proper analysis of the region in the vicinity of the contact line, as well as in the free boundary nature of the problem. It is known that continuum models assuming the no slip condition all the way to the contact line fail by predicting that the stress on the solid surface becomes singular as the contact line is approached. One approach for dealing with this issue has been to relax the no-slip boundary condition using the Navier model. Molecular dynamics simulations of the contact line region show that for a non-polar liquid on a solid surface, the no-slip boundary condition is in fact incorrect near the contact line. Furthermore, the same simulations also show that the usual relationship between stress and the rate of deformation breaks down in the vicinity of the contact line. In developing continuum theoretical models of the system, we shall accommodate this knowledge to the extent possible.

Subramanian, R. Shankar↗