Search NASA⌕ Search

SEARCH · Search NASA

Results for “x-ray diffraction detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Short-Lived Intermediate in the N2O Generation by P450 NO Reductase Captured by Time-Resolved IR Spectroscopy and XFEL Crystallography

Diffraction images were collected using an MX300-HS CCD detector. For each cryoloop, 2D raster scan with 50 μm step in each direction was performed twice. In the second pass, the raster-scan grid was shifted 25 μm in each direction. In cheetah directory, - {puck_name}/{pin_id}_hits.h5 correspond to the first scan, and - {puck_name}/{pin_id}-2_hits.h5 correspond to the second scan.

BL3↗

A New Residual Strain Mapping Program Using Energy Dispersive X-Ray Diffraction at the Advanced Photon Source

Here, the ability to non-destructively map the residual strain field inside an engineering component is important for predicting its fatigue life or developing processing methods to prevent failure or enhance performance. In this paper, we describe a new residual strain mapping program at the Advanced Photon Source, Argonne National Laboratory. The new program is based on energy dispersive x-ray diffraction (EDXRD). It is capable of non-destructively penetrating a several- cm thick polycrystalline sample fabricated from engineering alloys using high-energy x-rays and measuring the residual strain field with mm or better spatial resolution and approximately ±1 x 10 -4 strain resolution. A multi-element detector array is employed to measure multiple strain components simultaneously. The residual strain mapping setup is augmented with a high-energy tomography capability, allowing precise alignment of the material volume of interest for residual strain mapping and providing a complementary view of the structure to understand the measured strain field. These measurement capabilities are demonstrated using several strain mapping examples ranging from polycrystalline structural alloys to biological materials. We also provide some guidance for the future users of the program for a successful residual strain mapping experiment. We are expanding the capabilities of the new setup with various in situ capabilities including thermo-mechanical loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Performance of Critical-angle Transmission Grating Prototypes for the Arcus Mission

Arcus is a proposed Explorer Class soft X-ray grating spectrometer. It aims to explore cosmic feedback by mapping hot gases within and between galaxies and galaxy clusters and characterizing jets and winds from supermassive black holes and to investigate the dynamics of protoplanetary disks and stellar accretion. Arcus features 12 m focal-length grazing-incidence silicon pore optics (SPO) developed for the Athena mission. Critical-angle transmission (CAT) gratings efficiently disperse high diffraction orders onto CCDs. We report new and improved X-ray performance results for Arcus-like CAT gratings, including a record resolving power for two coaligned CAT gratings. Multiple Arcus prototype grating facets were illuminated by an SPO at the PANTER facility. The facets consist of 32 × 32.5 mm 2 patterned silicon membranes, bonded to metal frames. The bonding angle is adjusted according to the measured average tilt angle of the grating bars in the membrane. Two simultaneously illuminated facets show a minor broadening of the Al-K α doublet in the 18th and 21st orders with the best-fit record effective resolving power of ${R}_{G}\approx {1.3}_{-0.5}^{+\infty }\times {10}^{4}$ (3σ), about three to four times the Arcus requirement. We measured the diffraction efficiency of quasi-fully illuminated gratings at O-K wavelengths in orders 4–7 in an Arcus-like configuration and compare results with synchrotron spot measurements. After corrections for geometrical effects and bremsstrahlung continuum, we find agreement between full and spot illumination at the two different facilities, as well as with the models used for Arcus effective area predictions. We find that these flight-like gratings meet the diffraction efficiency and greatly exceed the resolving power Arcus requires.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous ambient pressure x-ray photoelectron spectroscopy and grazing incidence x-ray scattering in gas environments

We have developed an experimental system to simultaneously measure surface structure, morphology, composition, chemical state, and chemical activity for samples in gas phase environments. This is accomplished by simultaneously measuring x-ray photoelectron spectroscopy (XPS) and grazing incidence x-ray scattering in gas pressures as high as the multi-Torr regime while also recording mass spectrometry. Scattering patterns reflect near-surface sample structures from the nano-scale to the meso-scale, and the grazing incidence geometry provides tunable depth sensitivity of structural measurements. Scattered x rays are detected across a broad range of angles using a newly designed pivoting-UHV-manipulator for detector positioning. At the same time, XPS and mass spectrometry can be measured, all from the same sample spot and under ambient conditions. To demonstrate the capabilities of this system, we measured the chemical state, composition, and structure of Ag-behenate on a Si(001) wafer in vacuum and in O 2 atmosphere at various temperatures. These simultaneous structural, chemical, and gas phase product probes enable detailed insights into the interplay between the structure and chemical state for samples in gas phase environments. The compact size of our pivoting-UHV-manipulator makes it possible to retrofit this technique into existing spectroscopic instruments installed at synchrotron beamlines. Because many synchrotron facilities are planning or undergoing upgrades to diffraction limited storage rings with transversely coherent beams, a newly emerging set of coherent x-ray scattering experiments can greatly benefit from the concepts we present here.

47 OTHER INSTRUMENTATION↗

Quantitative uranium elemental reconstruction using spectral x-ray radiography

X-ray radiography offers the ability to noninvasively inspect the internal structure and material composition of objects. Dual-energy radiography allows material discrimination but is limited in quantitative material measurements due to the broad nature of the interrogating x-ray spectrum. Spectral radiography detectors provide an observation of not just the number of x rays that are transmitted through a sample but also the spectrum. Here, experimental validations of a method to use spectral x-ray radiography to accurately quantify the uranium mass in a powder are presented. An accurate system response model was developed, which includes a model of the incident x-ray source spectrum and a pixel-wise detector response that describes how the transmitted x rays were observed. Further, a calibration to account for the effect of partial x-ray attenuation was developed. As a result, the method is demonstrated to be capable of estimating the uranium mass in a variety of uranium oxide powders to a bias of –0.01±0.62%.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High Harmonic Generation Seeding Echo-Enabled Harmonic Generation toward a Storage Ring-Based Tender and Hard X-ray-Free Electron Laser

To align with the global trend of integrating synchrotron light source (SLS) and free electron laser (FEL) facilities on one site, in line with examples such as SPring-8 and SACLA in Japan and ELETTRA and FERMI in Italy, we actively explore FEL options leveraging the ultralow-emittance electron beam of the NSLS-II upgrade. These options show promising potential for synergy with storage ring (SR) operations, thereby significantly enhancing our facility’s capabilities. Echo-enabled harmonic generation (EEHG) is well-suited to SR-based FELs, and has already been demonstrated with the capability of generating extremely narrow bandwidth as well as high brightness, realized using diffraction-limited short pulses in transverse planes and Fourier transform-limited bandwidth in the soft X-ray spectrum. However, regarding a conventional EEHG scheme, the combination of the shortest seed laser wavelength (256 nm) and highest harmonic (200) sets the short wavelength limit to λ = 1.28 nm. To further extend the short wavelength limit down to the tender and hard X-ray region, a vital option is to shorten the seed laser wavelength. Thanks to recent advances in high harmonic generation (HHG), packing 10 9 photons at one harmonic within a few-femtosecond pulse could turn such a novel HHG source into an ideal seeding for EEHG. Thus, compared to the cascaded EEHG, the HHG seeding option could not only lower the cost, but also free the SR space for accommodating more user beamlines. Moreover, to mitigate the SASE background noise on the sample and detector, we combine the HHG seeding EEHG with the crab cavity short pulse scheme for maximum benefit.

36 MATERIALS SCIENCE↗

Thermal Processing Conditions for the Synthesis of Near Theoretical Density Li 5 La 3 Ta 2 O 12 Ceramics for Ceramic Dual-Mode Detectors

A family of Li-containing garnet compounds, extensively investigated for Li-ion solid electrolyte applications, show great potential to be developed into transparent ceramic dual-mode scintillators. In particular, Li 5 La 3 Ta 2 O 12 (LLTaO) shows promise as an efficient dual-mode scintillator due to its high Li content, high density, non-hygroscopicity, and high effective-Z. Often the synthesis of LLTaO ceramics involves solid state processing techniques starting with oxide and carbonate powders, calcining, sintering for the removal of residual porosity, and post-processing. This study focuses on two objectives: (1) establishing thermal processing boundary conditions for a flexible alkoxide-based sol-gel method for synthesizing fine-grained powders; and (2), consolidating powders via hot-pressing to form high-density ceramics. In this study, near single-phase ceramics were achieved by hot-pressing sol-gel powders with varying amounts of excess Li. Rietveld refinements were used to analyze X-ray diffraction data and provide a quantitative evaluation of the phases present in the hot pressed ceramics. Some of the diffraction data showed large low angle peak asymmetry, suggesting the presence of two cubic Li 5 La 3 Ta 2 O 12 garnet phases with different lattice parameters. Depending on the synthesis and processing conditions, the refinement revealed ~ 90 wt% concentration of a phase with a ≈ 12.8 Å and ~ 10 wt% concentration of a phase with a ≈ 12.9 Å, indicating a remaining excess of Li in the hot pressed ceramics in the large lattice parameter phase. These synthesis experiments allowed for the determination of a baseline for Li loss during hot-pressing. X-ray excited radioluminescence and photoluminescence excitation and emission spectra were obtained from the hot pressed ceramics. In conclusion, the measured emission spectra featured broad tantalate emission and line emissions likely from a rare-earth impurity.

36 MATERIALS SCIENCE↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗

Phase transformation and growth mechanism of RF sputtered ferroelectric lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 ) films

Lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 , PST), an order/disorder ferroelectric, is a potential candidate for electrocaloric cooling and pyroelectric infrared (IR) detector. In this work, we report the phase transformation kinetics from two series of samples containing pure amorphous and mixture of amorphous and pyrochlore to desired perovskite phase using postdeposition rapid thermal processing (RTP) as well as growth mechanism of RF sputtered PST thin films using excess lead target on platinized silicon (Pt/Ti/SiO 2 /Si) substrates. We find that small changes in the temperature ramp have a large effect on the degree of perovskite conversion (ferroelectric phase), orientation (crystallographic texture), and long-range order parameter (< S 111 >). Through isothermal annealing, we obtained optimal perovskite phase at ≥700°C temperature. The phase transformation is characterized by spontaneous formation of center-type in-plane radial rosette-like structures revealed by scanning electron microscopy. The PST perovskite crystallites were found to coexist with pyrochlore in RTP annealed films. The volume fractions for perovskite and pyrochlore phase were obtained from the analysis of “rosettes” and respective X-ray diffraction intensities which helped to determine various parameters associated with phase kinetics (n, k, and activation energy, Ea) and accompanying growth. The effective activation energies of perovskite transition and growth were found to be 332 ± 11 kJ/mol (345 ± 11 kJ/mol) and 114 ± 10 kJ/mol (122 ± 10 kJ/mol), respectively, for pure amorphous only (and mixed amorphous and pyrochlore) phase following nucleation-growth controlled Avrami's equation. A linear growth rate (n~1) for the perovskite phase indicates predominant interface-controlled process and diffusion-limited phenomena thus inhibiting rosette size owing to reactant depletion and soft impingement at the grain boundary. However, the growth behavior is isotropic in two-dimension parallel to the plane of the substrates for both sample series. Furthermore, lead loss was severe for in-situ growth and RTP combined with conventional furnace annealing than those of RTP only films, which were closer to stoichiometric albeit with excess lead and marginal oxygen vacancies (V o ).

36 MATERIALS SCIENCE↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗

A machine learning photon detection algorithm for coherent x-ray ultrafast fluctuation analysis

X-ray free electron laser experiments have brought unique capabilities and opened new directions in research, such as creating new states of matter or directly measuring atomic motion. One such area is the ability to use finely spaced sets of coherent x-ray pulses to be compared after scattering from a dynamic system at different times. This enables the study of fluctuations in many-body quantum systems at the level of the ultrafast pulse durations, but this method has been limited to a select number of examples and required complex and advanced analytical tools. By applying a new methodology to this problem, we have made qualitative advances in three separate areas that will likely also find application to new fields. As compared to the “droplet-type” models, which typically are used to estimate the photon distributions on pixelated detectors to obtain the coherent x-ray speckle patterns, our algorithm achieves an order of magnitude speedup on CPU hardware and two orders of magnitude improvement on GPU hardware. We also find that it retains accuracy in low-contrast conditions, which is the typical regime for many experiments in structural dynamics. Finally, it can predict photon distributions in high average-intensity applications, a regime which up until now has not been accessible. Our artificial intelligence-assisted algorithm will enable a wider adoption of x-ray coherence spectroscopies, by both automating previously challenging analyses and enabling new experiments that were not otherwise feasible without the developments described in this work.

47 OTHER INSTRUMENTATION↗

Molecular beam epitaxy of superconducting zirconium nitride on GaN substrates

Epitaxial integration of metals and semiconductors can enable enhanced performance and novel functionality. Achieving such pristine interfaces with superconducting materials is of increasing interest for quantum devices and detectors, but the experimental demonstration remains challenging, given the very limited studies on single crystalline systems. To expand the potential materials for these systems, this work explores the deposition of zirconium nitride superconducting thin films on GaN substrates at various temperatures using molecular beam epitaxy. A general trend of decreasing superconducting critical temperature is observed as the deposition temperature is reduced. The optical properties reveal a transition from metallic to dielectric behavior with colder deposition. The plasma frequency of the metallic films is also observed to be a function of growth temperature. These results pave the way for the integration of a highly tunable metal nitride with a well-established semiconductor system.

36 MATERIALS SCIENCE↗

AUTOIGNITION DELAY TIMES FOR REFORMATE GAS MIXTURES FROM METHANE GAS ENGINES

Methane slip is a prominent issue in natural gas reciprocating engines that are used in transportation and marine applications. The incomplete combustion that results in methane slip can be resolved with the introduction of hydrogen within the combustion mixture to improve methane oxidation and further enable combustion within the engine crevices where methane has previously remained unreacted. Steam methane reforming (SMR) is a common method used to produce hydrogen and can be used to design an onboard device to reduce methane slip from reciprocating engines. The development of this reformer device requires the validation of high-fidelity chemical kinetic models at the low temperatures of the crevice volumes of these engines. In this work, auto-ignition data is obtained using a shock tube at lean (φ—0.714 or λ—1.4) and stoichiometric (φ, λ = 1) equivalence ratios spanning a temperature range of 1042–1234 K at the 80-bar operating pressure of the test engine. Blends of methane, hydrogen, and reformate products from the SMR reaction are shock-heated in synthetic air, with the ignition delay time measured using an OH* chemiluminescence detector at 310 nm and a CH* detector at 430 nm. The experimental results are compared to several state-of-the-art chemical kinetic mechanisms from the literature. In general, most of the mechanisms show very good agreement with experiments at higher temperatures, with simulation results showing little deviation from experiments at lower temperatures. A sensitivity analysis was conducted, and the results reveal that the reaction H2 + CH3O2 = H + CH3O2H has a very significant role in determining low-temperature ignition delay times (IDTs) of SMR mixtures. These findings provide valuable insights into the chemical kinetics governing methane reformate combustion and contribute to the optimization of onboard reformer designs aimed at mitigating methane slip in natural gas-fueled engines.

Fraze, Matthew↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗