Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software TEMA Motion is used to track the spot which marked the cage surface. Finally, by developing the MATLAB program, a Lissajous’ figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Three-Dimensional Imaging of Heterogeneous Materials by Thermal Tomography

Infrared thermal imaging based on active thermal excitations has been widely used for nondestructive evaluation ( NDE) of materials. While the experimental systems have remained essentially the same during the last few decades, development of advanced data-processing methods has significantly improved the capabilities of this technology. However, many limitations still exist. One fundamental limitation is the requirement, either explicitly or implicitly, of the tested material to be homogeneous such that detected thermal contrasts may be used to determine an average material property or attributed to flaws. In this paper, a new thermal tomography ( TT) method is introduced, which for the first time can evaluate heterogeneous materials by directly imaging their thermal-property variations with space. It utilizes one-sided flash thermal-imaging data to construct the three-dimensional ( 3D) distribution of thermal effusivity in the entire volume of a test sample. Theoretical analyses for single and multilayer material systems were conducted to validate its formulation and to demonstrate its performance. Experimental results for a ceramic composite plate and a thermal barrier coating ( TBC) sample are also presented. It was shown that thermal diffusion is the primary factor that degrades the spatial resolution with depth for TT; the spatial resolutions in the lateral and axial directions were quantitatively evaluated.

47 OTHER INSTRUMENTATION↗

Weathering the Storm: Unmanned Aircraft Systems in the Maritime, Atmospheric and Polar Environments

Remotely piloted aircraft (RPA) have the potential to revolutionize local to regional data collection for geophysicists as platform and payload size decrease while aircraft capabilities increase. In particular, data from RPAs combine high-resolution imagery available from low flight elevations with comprehensive areal coverage, unattainable from ground investigations and difficult to acquire from manned aircraft due to budgetary and logistical costs. Low flight elevations are particularly important for detecting signals that decay exponentially with distance, such as electromagnetic fields. Onboard data processing coupled with high-bandwidth telemetry open up opportunities for real-time and near real-time data processing, producing more efficient flight plans through the use of payload-directed flight, machine learning and autonomous systems. Such applications not only strive to enhance data collection, but also enable novel sensing modalities and temporal resolution. NASAs Airborne Science Program has been refining the capabilities and applications of RPA in support of satellite calibration and data product validation for several decades. In this paper, we describe current platforms, payloads, and onboard data systems available to the research community. Case studies include Fluid Lensing for littoral zone 3D mapping, structure from motion for terrestrial 3D multispectral imaging, and airborne magnetometry on medium and small RPAs.

data collection↗

Extensive 3D mapping of dislocation structures in bulk aluminum

Abstract Thermomechanical processing such as annealing is one of the main methods to tailor the mechanical properties of materials, however, much is unknown about the reorganization of dislocation structures deep inside macroscopic crystals that give rise to those changes. Here, we demonstrate the self-organization of dislocation structures upon high-temperature annealing in a mm-sized single crystal of aluminum. We map a large embedded 3D volume ( $$100\times 300\times 300$$ 100 × 300 × 300 $$\upmu$$ μ m $$^3$$ 3 ) of dislocation structures using dark field X-ray microscopy (DFXM), a diffraction-based imaging technique. Over the wide field of view, DFXM’s high angular resolution allows us to identify subgrains, separated by dislocation boundaries, which we identify and characterize down to the single-dislocation level using computer-vision methods. We demonstrate how even after long annealing times at high temperatures, the remaining low density of dislocations still pack into well-defined, straight dislocation boundaries (DBs) that lie on specific crystallographic planes. In contrast to conventional grain growth models, our results show that the dihedral angles at the triple junctions are not the predicted 120 $$^{\circ }$$ ∘ , suggesting additional complexities in the boundary stabilization mechanisms. Mapping the local misorientation and lattice strain around these boundaries shows that the observed strain is shear, imparting an average misorientation around the DB of $$\approx$$ ≈ 0.003 to 0.006 $$^{\circ }$$ ∘ .

36 MATERIALS SCIENCE↗

TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

60 APPLIED LIFE SCIENCES↗

Using Remotely Piloted Aircraft and Onboard Processing to Optimize and Expand Data Collection

Remotely piloted aircraft (RPA) have the potential to revolutionize local to regional data collection for geophysicists as platform and payload size decrease while aircraft capabilities increase. In particular, data from RPAs combine high-resolution imagery available from low flight elevations with comprehensive areal coverage, unattainable from ground investigations and difficult to acquire from manned aircraft due to budgetary and logistical costs. Low flight elevations are particularly important for detecting signals that decay exponentially with distance, such as electromagnetic fields. Onboard data processing coupled with high-bandwidth telemetry open up opportunities for real-time and near real-time data processing, producing more efficient flight plans through the use of payload-directed flight, machine learning and autonomous systems. Such applications not only strive to enhance data collection, but also enable novel sensing modalities and temporal resolution. NASA’s Airborne Science Program has been refining the capabilities and applications of RPA in support of satellite calibration and data product validation for several decades. In this paper, we describe current platforms, payloads, and onboard data systems available to the research community. Case studies include Fluid Lensing for littoral zone 3D mapping, structure from motion for terrestrial 3D multispectral imaging, and airborne magnetometry on medium and small RPAs.

Fladeland, Matthew M.↗

LiDAR-Based Map Relative Localization Performance Analysis for Landing on Europa

This paper presents preliminary simulations andanalyses done to assess the feasibility of performing Map RelativeLocalization (MRL) with the Europa Lander LiDAR beingdeveloped for the Europa Lander Pre-Phase A concept. MapRelative Localization is the process of determining the horizontalposition of a lander with respect to an onboard, a-priori map,by comparing the map to sensor observations of the terrain duringdeorbit, descent, and landing (DDL). Although kilometerscaleposition knowledge is commonly available during DDL,landing in hazard-rich environments requires position errors of100 m or less. Prior knowledge in the case of Europa Landerwill be visual and topographic maps collected by the upcomingEuropa Clipper mission. The Mars 2020 Lander Vision System(LVS) uses images from a camera to localize with respect tovisual maps. This technology, as well as a 3D imaging LiDAR indevelopment for hazard detection, is currently baselined for theEuropa Lander Pre-Phase A concept. This paper investigatesthe potential use of the hazard detection LiDAR to performMRL with respect to a 3D digital elevation model (DEM)provided by the Europa Clipper mission, as an alternative orbackup solution to passive optical MRL. Compared to passiveoptical MRL, one advantage of LiDAR-based localization isthat it is insensitive to lighting conditions, potentially relaxingrequirements on synchronizing map acquisition and landingtime of day. To analyze LiDAR based MRL performance,six representative terrains are synthetically up-sampled fromGalileo-derived maps of Europa to a resolution of 0.5 m/pxand covering an area of 4 km by 4 km. These maps are usedas ground-truth to generate simulated noisy a-priori onboardtopographic maps expected from Europa Clipper as well assimulated LiDAR DEMs generated at an altitude of 5 km duringEuropa Lander DDL. The simulated LiDAR DEM is matchedagainst the simulated map via 2D normalized cross-correlation,exploiting the accurately known spacecraft attitude to avoidthe need for more computationally intensive algorithms such asIterative Closest Point (ICP). Two sources of measurement errorare identified for analysis: 1) additive Gaussian noise in therange measurements from the Europa Lander LiDAR and theEuropa Clipper derived maps and 2) errors in the LiDAR DEMinduced by errors in the Europa Lander state estimate which isused to de-warp the LiDAR scan data into a DEM format. Weassess the effect of each of these types of errors independently onmatching performance as well as the overall performance whenall types of error are introduced. Additionally, we present theresult of a sensitivity study to terrain frequency content.

Trawny, Nikolas↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

3D Imaging of Nickel Oxidation States using Full Field X-ray Absorption Near Edge Structure Nanotomography

Reduction-oxidation (redox) cycling of the nickel electrocatalyst phase in the solid oxide fuel cell (SOFC) anode can lead to performance degradation and cell failure. A greater understanding of nickel redox mechanisms at the microstructural level is vital to future SOFC development. Transmission x-ray microscopy (TXM) provides several key techniques for exploring oxidation states within SOFC electrode microstructure. Specifically, x-ray nanotomography and x-ray absorption near edge structure (XANES) spectroscopy have been applied to study samples of varying nickel (Ni) and nickel oxide (NiO) compositions. The imaged samples are treated as mock SOFC anodes containing distinct regions of the materials in question. XANES spectra presented for the individual materials provide a basis for the further processing and analysis of mixed samples. Images of composite samples obtained are segmented, and the distinct nickel and nickel oxide phases are uniquely identified using full field XANES spectroscopy. Applications to SOFC analysis are discussed.

30 DIRECT ENERGY CONVERSION↗

Postmortem analysis of sand grain crushing from pile interface using X-ray tomography

Pile foundations of offshore platforms, wind and water turbines are typically subjected to a variety of cyclic loading paths due to their complex environment. While many studies focus on global pile behaviour, the soil-pile interface is explored here by a micromechanical study of the soil layer in contact with the pile surface. This work is devoted to the analysis of frozen post-mortem silica sand samples recovered at the pile interface following installation and cyclic loading tests in a calibration chamber using x-ray tomography. An experimental procedure developed for three dimensional (3D) snow imaging was adapted for the recovery of the in-situ sand samples to preserve their structure during tomography scans. 3D images at a pixel size of 7 {mu}m were then obtained using a cryogenic cell. Results confirm the presence of a shear band at the pile surface as well as void ratios changes in the direction of the pile's radius.

36 MATERIALS SCIENCE↗

SU-E-J-237: Real-Time 3D Anatomy Estimation From Undersampled MR Acquisitions

Recent developments made MRI guided radiotherapy feasible. Performing simultaneous imaging during fractions can provide information about changing anatomy by means of deformable image registration for either immediate plan adaptations or accurate dose accumulation on the changing anatomy. In 3D MRI, however, acquisition time is considerable and scales with resolution. Furthermore, intra-scan motion degrades image quality.In this work, we investigate the sensitivity of registration quality on imageresolution: potentially, by employing spatial undersampling, the acquisition timeof MR images for the purpose of deformable image registration can be reducedsignificantly.On a volunteer, 3D-MR imaging data was sampled in a navigator-gated manner, acquiring one axial volume (360×260×100mm{sup 3}) per 3s during exhale phase. A T1-weighted FFE sequence was used with an acquired voxel size of (2.5mm{sup 3}) for a duration of 17min. Deformation vector fields were evaluated for 100 imaging cycles with respect to the initial anatomy using deformable image registration based on optical flow. Subsequently, the imaging data was downsampled by a factor of 2, simulating a fourfold acquisition speed. Displacements of the downsampled volumes were then calculated by the same process.In kidneyliver boundaries and the region around stomach/duodenum, prominent organ drifts could be observed in both the original and the downsampled imaging data. An increasing displacement of approximately 2mm was observed for the kidney, while an area around the stomach showed sudden displacements of 4mm. Comparison of the motile points over time showed high reproducibility between the displacements of high-resolution and downsampled volumes: over a 17min acquisition, the componentwise RMS error was not more than 0.38mm.Based on the synthetic experiments, 3D nonrigid image registration shows little sensitivity to image resolution and the displacement information is preserved even when halving the resolution. This can be employed to greatly reduce image acquisition times for interventional applications in real-time. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

PFLOTRAN modeling data and scripts associated with “Refining the Hydrogeologic Framework of a Large River Corridor Model Using Waterborne Transient Electromagnetics”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the publication “Refining the Hydrogeologic Framework of a Large River Corridor Model Using Waterborne Transient Electromagnetics” submitted to Water Resources Research (Terry et al. 2025). The data package contains the groundwater modeling dataset from PFLOTRAN software. It includes the python script for mesh generation, boundary condition setting, PFLOTRAN input deck formation and postprocessing. It couples groundwater flow and species transport for Hanford Reach river corridor and pipelines the model generation and processing. This model can be used to easily generate the model and analysis for Hanford site. It can also be adjusted to other hydrologic area with ease. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. The data package consists of 6 folders: (1) “data” contains all necessary data as input and intermediate data for processing; (2) “mesh” contains all mesh related files to generate mesh in Hanford Reach river corridor; (3) “model_run” contains the generated script for PFLOTRAN modeling; (4) “notebooks” contains all the Python script to generate the model; (5) “output” contains all the output from the computation; (6) “postprocessing” contains the Python script to generate scientific figure for manuscript. All files are .csv (comma-separated values), .h5 (HDF5 format), .in (input files), .ipynb (Jupyter notebooks), .p (Python pickle), .png (images), .PNG (images), .py (Python scripts), .pyc (Python bytecode), .r (R scripts), .sh (shell scripts), .txt (text files), .vtu (3D mesh/visualization format), .xz (compressed archive), or .zip (compressed archive).

54 ENVIRONMENTAL SCIENCES↗

A Tool for the Automated Collection of Space Utilization Data: Three Dimensional Space Utilization Monitor

Space Human Factors and Habitability (SHFH) Element within the Human Research Program (HRP), in collaboration with the Behavioral Health and Performance (BHP) Element, is conducting research regarding Net Habitable Volume (NHV), the internal volume within a spacecraft or habitat that is available to crew for required activities, as well as layout and accommodations within that volume. NASA is looking for innovative methods to unobtrusively collect NHV data without impacting crew time. Data required includes metrics such as location and orientation of crew, volume used to complete tasks, internal translation paths, flow of work, and task completion times. In less constrained environments methods for collecting such data exist yet many are obtrusive and require significant post‐processing. Example technologies used in terrestrial settings include infrared (IR) retro‐reflective marker based motion capture, GPS sensor tracking, inertial tracking, and multiple camera filmography. However due to constraints of space operations many such methods are infeasible, such as inertial tracking systems which typically rely upon a gravity vector to normalize sensor readings, and traditional IR systems which are large and require extensive calibration. However multiple technologies have not yet been applied to space operations for these explicit purposes. Two of these include 3‐Dimensional Radio Frequency Identification Real‐Time Localization Systems (3D RFID‐RTLS) and depth imaging systems which allow for 3D motion capture and volumetric scanning (such as those using IR‐depth cameras like the Microsoft Kinect or Light Detection and Ranging / Light‐Radar systems, referred to as LIDAR).

Vos, Gordon A.↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Deblurring for nuclei: 3D characteristics of heavy-ion collisions

Observables from nuclear and high-energy experiments can be degraded by detector performance and/or methodology in extracting the observables, such as of the final-state characteristics of heavy-ion collisions in relation to a coarsely estimated reaction-plane direction. We propose the use of deblurring methods, such as in optics, to correct for observable degradation. Our main focus is the restoration of triple-differential particle distributions in heavy-ion collisions. We demonstrate that these could be extracted from collision measurements following the Richardson-Lucy deblurring method from optics. We illustrate basic features of the restoration methodology in a schematic model assuming either ideal or more realistic particle detection. Here, the inferred three-dimensional (3D) distributions for collisions may be easier to interpret in terms of collision dynamics and sought properties of bulk matter than the currently employed Fourier coefficients, that combine information from different azimuthal angles relative to the reaction plane.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-I-14: 3D Breast Digital Phantom for XACT Imaging

Purpose: The X-ray induced acoustic computed tomography (XACT) is a new imaging modality which combines X-ray contrast and high ultrasonic resolution in a single modality. Using XACT in breast imaging, a 3D breast volume can be imaged by only one pulsed X-ray radiation, which could dramatically reduce the imaging dose for patients undergoing breast cancer screening and diagnosis. A 3D digital phantom that contains both X-ray properties and acoustic properties of different tissue types is indeed needed for developing and optimizing the XACT system. The purpose of this study is to offer a realistic breast digital phantom as a valuable tool for improving breast XACT imaging techniques and potentially leading to better diagnostic outcomes. Methods: A series of breast CT images along the coronal plane from a patient who has breast calcifications are used as the source images. A HU value based segmentation algorithm is employed to identify breast tissues in five categories, namely the skin tissue, fat tissue, glandular tissue, chest bone and calcifications. For each pixel, the dose related parameters, such as material components and density, and acoustic related parameters, such as frequency-dependent acoustic attenuation coefficient and bandwidth, are assigned based on tissue types. Meanwhile, other parameters which are used in sound propagation, including the sound speed, thermal expansion coefficient, and heat capacity are also assigned to each tissue. Results: A series of 2D tissue type image is acquired first and the 3D digital breast phantom is obtained by using commercial 3D reconstruction software. When giving specific settings including dose depositions and ultrasound center frequency, the X-ray induced initial pressure rise can be calculated accordingly. Conclusion: The proposed 3D breast digital phantom represents a realistic breast anatomic structure and provides a valuable tool for developing and evaluating the system performance for XACT.

60 APPLIED LIFE SCIENCES↗

Computer-controlled multi-parameter mapping of 3D compressible flowfields using planar laser-induced iodine fluorescence

A computer-controlled technique, using planar laser-induced iodine fluorescence, for measuring complex compressible flowfields is presented. A new laser permits the use of a planar two-line temperature technique so that all parameters can be measured with the laser operated narrowband. Pressure and temperature measurements in a step flowfield show agreement within 10 percent of a CFD model except in regions close to walls. Deviation of near wall temperature measurements from the model was decreased from 21 percent to 12 percent compared to broadband planar temperature measurements. Computer-control of the experiment has been implemented, except for the frequency tuning of the laser. Image data storage and processing has been improved by integrating a workstation into the experimental setup reducing the data reduction time by a factor of 50.

Donohue, James M.↗

Preliminary hyperspectral neutron radiography of binder jet 3D printed and melt infiltrated Si–SiC

The preliminary results of hyperspectral neutron radiography of Si–SiC made with binder jet additive manufacturing, subsequent carbon addition, and silicon melt infiltration are presented. The samples were measured in the processing states before and after the melt infiltration to determine if neutrons would help characterize the microstructure to better understand the melt infiltration process. Theoretical Bragg edges were calculated for comparison with the radiographic results. The changes in the Bragg edges from pre- to post-infiltrated reaction-bonded SiC were evident, that could be used to address the differences in microstructures. In conclusion, the preliminary results presented in this study demonstrated that neutron Bragg-edge imaging is possible with Si–SiC reaction-bonded ceramics and can help determine the microstructure of melt infiltrated samples.

SiC↗