Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABERRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Design of collection optics and polychromators for a JT-60SA Thomson scattering system

This paper presents designs of collection optics for a JT-60SA Thomson scattering system. By using tangential (to the toroidal direction) YAG laser injection, three collection optics without strong chromatic aberration generated by the wide viewing angle and small design volume were found to measure almost all the radial space. For edge plasma measurements, the authors optimized the channel number and wavelength ranges of band-pass filters in a polychromator to reduce the relative error in T{sub e} by considering all spatial channels and a double-pass laser system with different geometric parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnifying lens for 800 MeV proton radiography

This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion optics of RHIC electron beam ion source

RHIC electron beam ion source has been commissioned to operate as a versatile ion source on RHIC injection facility supplying ion species from He to Au for Booster. Except for light gaseous elements RHIC EBIS employs ion injection from several external primary ion sources. With electrostatic optics fast switching from one ion species to another can be done on a pulse to pulse mode. The design of an ion optical structure and the results of simulations for different ion species are presented. In the choice of optical elements special attention was paid to spherical aberrations for high-current space charge dominated ion beams. The combination of a gridded lens and a magnet lens in LEBT provides flexibility of optical control for a wide range of ion species to satisfy acceptance parameters of RFQ. The results of ion transmission measurements are presented.

43 PARTICLE ACCELERATORS↗

An electron energy loss spectrometer designed for studies of electronic energy losses and spin waves in the large momentum regime

Based on 143 deg. electrostatic deflectors we have realized a new spectrometer for electron energy loss spectroscopy which is particularly suitable for studies on surface spin waves and other low energy electronic energy losses. Contrary to previous designs high resolution is maintained even for diffuse inelastic scattering due to a specific management of the angular aberrations in combination with an angle aperture. The performance of the instrument is demonstrated with high resolution energy loss spectra of surface spin waves on a cobalt film deposited on the Cu(100) surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration method for nanosecond-resolved, time-streaked, fiber optic light collection, spectroscopy systems

This paper describes a convenient and accurate method to calibrate fast (<1 ns resolution) streaked, fiber optic light collection, spectroscopy systems. Such systems are inherently difficult to calibrate due to the lack of sufficiently intense, calibrated light sources. Such a system is used to collect spectral data on plasmas generated in electron beam diodes fielded on the RITS-6 accelerator (8-12MV, 140-200kA) at Sandia National Laboratories. On RITS, plasma light is collected through a small diameter (200 {mu}m) optical fiber and recorded on a fast streak camera at the output of a 1 meter Czerny-Turner monochromator. For this paper, a 300 W xenon short arc lamp (Oriel Model 6258) was used as the calibration source. Since the radiance of the xenon arc varies from cathode to anode, just the area around the tip of the cathode ('hotspot') was imaged onto the fiber, to produce the highest intensity output. To compensate for chromatic aberrations, the signal was optimized at each wavelength measured. Output power was measured using 10 nm bandpass interference filters and a calibrated photodetector. These measurements give power at discrete wavelengths across the spectrum, and when linearly interpolated, provide a calibration curve for the lamp. The shape of the spectrum is determined by the collective response of the optics, monochromator, and streak tube across the spectral region of interest. The ratio of the spectral curve to the measured bandpass filter curve at each wavelength produces a correction factor (Q) curve. This curve is then applied to the experimental data and the resultant spectra are given in absolute intensity units (photons/sec/cm{sup 2}/steradian/nm). Error analysis shows this method to be accurate to within +/- 20%, which represents a high level of accuracy for this type of measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Asymmetric twins in rhombohedral boron carbide

Superhard materials consisting of light elements have recently received considerable attention because of their ultrahigh specific strength for a wide range of applications as structural and functional materials. However, the failure mechanisms of these materials subjected to high stresses and dynamic loading remain to be poorly known. We report asymmetric twins in a complex compound, boron carbide (B{sub 4}C), characterized by spherical-aberration-corrected transmission electron microscopy. The atomic structure of boron-rich icosahedra at rhombohedral vertices and cross-linked carbon-rich atomic chains can be clearly visualized, which reveals unusual asymmetric twins with detectable strains along the twin interfaces. This study offers atomic insights into the structure of twins in a complex material and has important implications in understanding the planar defect-related failure of superhard materials under high stresses and shock loading.

36 MATERIALS SCIENCE↗

Revealing the atomic and electronic structure of a SrTiO{sub 3}/LaNiO{sub 3}/SrTiO{sub 3} heterostructure interface

The atomic structures of SrTiO{sub 3} (STO)/LaNiO{sub 3} (LNO)/STO heterostructure interfaces were investigated by spherical aberration-corrected (C{sub S}) (scanning) transmission electron microscopy. Atomic displacement and lattice distortion measurements and electron energy loss spectroscopy (EELS) were used to quantitatively analyze the distortion of the interfacial octahedra and the bond length at the interfaces. Combined with high-resolution transmission electron microscopy (HRTEM) and scanning transmission electron microscopy analyses, two distinct interfacial atomic terminating layers are unambiguously determined. Ensuing quantitative HRTEM measurements revealed that the Ni-O bond length in the interfacial octahedral is elongated at the bottom interface (–NiO{sub 2}-SrO–). Atomic displacement shows structural relaxation effects when crossing the interfaces and lattice distortions across the interface is more pronounced in LNO than in STO. The Ti/O atomic ratio, La and Ti relative atomic ratio as derived by EELS quantification indicate non-stoichiometric composition at the interfaces. Distinct fine structures of Ti-L{sub 2,3} edge and O-K edge at the bottom and top interfaces are observed. By comparison, we are able to estimate Ti valency at both interfaces. Combining the structural distortions and Ti valency, the polar discontinuity and charge transfer at the interfaces are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding glass-forming ability through sluggish crystallization of atomically thin metallic glassy films

The glass-forming ability (GFA) of an alloy, closely related to its ability to resist crystallization, is a crucial issue in condensed matter physics. So far, the studies on GFA are mostly statistical and empirical guides. Benefiting from the ultrahigh thermal stability of ultrathin metallic glassy film and high resolution spherical aberration-corrected transmission electron microscope, the crystallization of atomically thin ZrCu and its microalloyed ZrCuAl glasses with markedly different GFA was investigated at the atomic scale. We find the Zr diffusivity estimated from the density of nuclei is dramatically decreased by adding of Al, which is the major reason for the much better GFA of the ZrCuAl metallic glass.

36 MATERIALS SCIENCE↗

Direct observation of interlocked domain walls and topological four-state vortex-like domain patterns in multiferroic YMnO{sub 3} single crystal

Using the advanced spherical aberration-corrected high angle annular dark field scanning transmission electron microscope imaging techniques, we investigated atomic-scale structural features of domain walls and domain patterns in YMnO{sub 3} single crystal. Three different types of interlocked ferroelectric-antiphase domain walls and two abnormal topological four-state vortex-like domain patterns are identified. Each ferroelectric domain wall is accompanied by a translation vector, i.e., 1/6[210] or −1/6[210], demonstrating its interlocked nature. Different from the four-state vortex domain patterns caused by a partial edge dislocation, two four-state vortex-like domain configurations have been obtained at atomic level. These observed phenomena can further extend our understanding of the fascinating vortex domain patterns in multiferroic hexagonal rare-earth manganites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TPK Sarimukti, Cipatat, West Bandung compost toxicity test using Allium test

TPK Sarimukti, Cipatat, West Bandung produced 2 kinds of compost from traditional market waste, liquid and solid compost. The aim of this research is to evaluate toxicity of compost produced in TPK Sarimukti using shallots (Allium cepa). Tests carried out by treated shallots with liquid compost (2,5%, 5%, 10% and 12,5% (w/v)) or solid compost (25%, 50%, 75% and 100% (w/v)) for 48 hours. Results showed reduced root growth rate and mitotic index (MI) in accordance with increased concentrations of compost. Sub lethal concentrations are liquid compost 5% and 10% and solid compost 75%. Lethal concentrations are liquid compost 12,5 % and solid compost 100%. Micronuclei (MN) increased with increase in liquid compost concentration. MN found at very high frequencies in highest solid compost concentration (100%), but very low at lower concentrations. Cells with binuclei and cell necrosis increased with increasing concentrations of given compost. Nuclear anomalies (NA) found in high frequency in 75% and 100% solid compost. Based on research, we can conclude that liquid compost is more toxic because it can reduce MI and root growth rate at lower concentrations than solid compost. Both types of compost have genotoxic properties because it can induce chromosome aberration (CA), MN, binuclei and NA formation.

60 APPLIED LIFE SCIENCES↗

Analysis of the beam halo in negative ion sources by using 3D3V PIC code

The physical mechanism of the formation of the negative ion beam halo and the heat loads of the multi-stage acceleration grids are investigated with the 3D PIC (particle in cell) simulation. The following physical mechanism of the beam halo formation is verified: The beam core and the halo consist of the negative ions extracted from the center and the periphery of the meniscus, respectively. This difference of negative ion extraction location results in a geometrical aberration. Furthermore, it is shown that the heat loads on the first acceleration grid and the second acceleration grid are quantitatively improved compared with those for the 2D PIC simulation result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A modified time-of-flight method for precise determination of high speed ratios in molecular beams

Time-of-flight (TOF) is a standard experimental technique for determining, among others, the speed ratio S (velocity spread) of a molecular beam. The speed ratio is a measure for the monochromaticity of the beam and an accurate determination of S is crucial for various applications, for example, for characterising chromatic aberrations in focussing experiments related to helium microscopy or for precise measurements of surface phonons and surface structures in molecular beam scattering experiments. For both of these applications, it is desirable to have as high a speed ratio as possible. Molecular beam TOF measurements are typically performed by chopping the beam using a rotating chopper with one or more slit openings. The TOF spectra are evaluated using a standard deconvolution method. However, for higher speed ratios, this method is very sensitive to errors related to the determination of the slit width and the beam diameter. The exact sensitivity depends on the beam diameter, the number of slits, the chopper radius, and the chopper rotation frequency. We present a modified method suitable for the evaluation of TOF measurements of high speed ratio beams. The modified method is based on a systematic variation of the chopper convolution parameters so that a set of independent measurements that can be fitted with an appropriate function are obtained. We show that with this modified method, it is possible to reduce the error by typically one order of magnitude compared to the standard method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the soft x-ray tomography beamline at Taiwan photon source

The optical design of the varied-line-spacing plane-grating monochromator for transmission full-field imaging of frozen-hydrated biological samples at NSRRC is presented. This monochromator consists of a plane mirror and three interchangeable gratings with groove densities 600, 1200 and 2400 l/mm to cover the energy range 260 – 2600 eV. The groove parameters of the varied-line-spacing plane gratings are designed to minimize the effect of coma and spherical aberration to maintain the exit slit in focus for any value of incident angle. All parameters of optical components at the beamline are verified with a ray-tracing method. In the beamline design, the calculated results from the ray-tracing codes and the expected performances are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent resistance switching in SrTiO{sub 3}

Resistance switching phenomena were studied by varying temperature in SrTiO{sub 3} single crystal. The resistance hysteresis loops appear at a certain temperature ranging from 340 K to 520 K. With the assistance of 375 nm ultraviolet continuous laser, the sample resistance is greatly reduced, leading to a stable effect than that in dark. These resistance switching phenomena only exist in samples with enough oxygen vacancies, which is confirmed by spherical aberration-corrected scanning transmission electron microscopy measurements, demonstrating an important role played by oxygen vacancies. At temperatures above 340 K, positively charged oxygen vacancies become mobile triggered by external electric field, and the resistance switching effect emerges. Our theoretical results based on drift-diffusion model reveal that the built-in field caused by oxygen vacancies can be altered under external electric field. Therefore, two resistance states are produced under the cooperative effect of built-in field and external field. However, the increasing mobility of oxygen vacancies caused by higher temperature promotes internal electric field to reach equilibrium states quickly, and suppresses the hysteresis loops above 420 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-spectroscopic composition measurements of SrTiO 3 -La 0.7 Sr 0.3 MnO 3 multilayers using scanning convergent beam electron diffraction

The local atomic structure of a crystalline sample aligned along a zone axis can be probed with a focused electron probe, which produces a convergent beam electron diffraction pattern. The introduction of high speed direct electron detectors has allowed for experiments that can record a full diffraction pattern image at thousands of probe positions on a sample. By incoherently summing these patterns over crystalline unit cells, we demonstrate in this paper that in addition to crystal structure and thickness, we can also estimate the local composition of a perovskite superlattice sample. This is achieved by matching the summed patterns to a library of simulated diffraction patterns. Finally, this technique allows for atomic-scale chemical measurements without requiring a spectrometer or hardware aberration correction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Femtosecond lasers for microsurgery of cornea

The review of femtosecond laser installations for medical applications is given and a new femtosecond ophthalmologic system for creation of a flap of corneal tissue during the LASIK operation is described. An all-fibre femtosecond laser emitting {approx}400-fs pulses at 1067 nm is used. The pulse repetition rate can vary from 200 kHz up to 1 MHz. The output energy of the femtosecond system does not exceed 1 {mu}J. A specially developed objective with small spherical and chromatic aberrations is applied to focus laser radiation to an area of an eye cornea. The size of the focusing spot does not exceed 3 {mu}m. To process the required area, scanning by a laser beam is applied with a speed no less than 5 m s{sup -1}. At a stage of preliminary tests of the system, the {Kappa}8 glass, organic PMMA glass and specially prepared agarose gels are used as a phantom of an eye. The femtosecond system is successfully clinically tested on a plenty of eyes of a pig and on several human eyes. The duration of the procedure of creation of a corneal flap does not exceed 20 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma channels during filamentation of a femtosecond laser pulse with wavefront astigmatism in air

We have demonstrated experimentally and numerically the possibility of controlling parameters of plasma channels formed during filamentation of a femtosecond laser pulse by introducing astigmatism in the laser beam wavefront. It is found that weak astigmatism increases the length of the plasma channel in comparison with the case of aberration-free focusing and that strong astigmatism can cause splitting of the plasma channel into two channels located one after another on the filament axis. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗