Development of Real-Time Quantitative Safety Evaluation Method for Nuclear Power Plants

Human operators involved with large process control systems such as nuclear power plants (NPPs) perform significant roles in the operation of systems. In this reason, deficiencies in human factors such as poor HSI (Human System Interface) design, procedure, and training, are significant contributing factors to NPPs incidents and accidents. In this regard, many kinds of studies including human reliability analysis (HRA), operation support system, automation, have been conducted in order to reduce human errors. Among these fields of studies, automation has its own specialty since it mainly focuses on eliminating the human error-inducing tasks to reduce human error, while other topics are primarily focusing on reducing human error by aiding human operators during operation. It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human errors. However, these beliefs are not always true in large and complex systems such as NPP, since excessive automation can generate new roles for human operators, change human operators' activities in unexpected ways, and inducing 'out-of-the-loop' (OOTL) problem. Especially, although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis, automation is not actively adopted since conventional machine learning techniques are neither capable nor reliable to handle overwhelmingly complex abnormal situations in NPP. Recently, newly developed 'deep learning' techniques have been actively applied to many fields, and some of these studies proved that the artificial intelligences (AI) based on deep learning techniques show better performance than that of human being. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, 'AlphaGo', which was developed by 'Google Deepmind' based on deep learning technique to play the game of Go, was defeated Se-dol Lee who is the World Go champion with score of 4:1. In the point of view that the game of Go is considered as one of the challenging area in machine learning field, it is verified that these new machine learning techniques can perform well, even better than the human being in high-complexity tasks. Previously, most of AI applications in nuclear field were focusing on supporting human operators' tasks such as diagnosis and decision making by rapid classification and prediction, based on fixed training data sets. However, it is expected that AI can be applied to solve more complicated problems (i.e. automation during abnormal states in NPP) by adopting advanced machine learning methodologies. In order to apply the automation system in NPP, firstly it is needed to evaluate the status of the plant quantitatively in real-time, since the information about which state is better (i.e. safe) or worse (i.e. unsafe) is essential for training properly working automation AI. Currently, there are several methodologies for NPP safety evaluation such as probabilistic safety assessment (PSA), safety performance indicator (SPI). However, existing methodologies are not feasible for development of automated system since they are not capable for the cases which are not included in the underlying model, not able to consider delicate changes in the NPP, and hard to evaluate in real-time. Therefore, development of new NPP safety evaluation methodology which can cover previously mentioned requirements is needed to conduct the study on NPP automation further. In this study, the concept of early warning score (EWS) in medical field was adopted to develop the methodology which can evaluate the safety level of the NPP quantitatively and in real-time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monte Carlo/CFD Coupling for Accurate Modeling of the Delayed Neutron Precursors and Compressibility Effects in Molten Salt Reactors

Multiphysics reactor analysis has become one of the leading activities of most nuclear engineering research groups. Coupled neutronics and thermal/hydraulics (T/H) simulations have traditionally been performed by adopting deterministic transport tools and reactor system T/H codes. The main reason for avoiding higher fidelity numerical methods like continuous-energy Monte Carlo analysis has been the high computational cost of coupled, full-scale simulations. Nowadays, high fidelity multiphysics simulations represent a hot research topic, with several applications involving advanced nuclear systems. Liquid fuel Molten Salt Reactors (MSRs) feature peculiar physical phenomena that are not present in solid fuel reactors. Some of these phenomena are not correctly resolved by legacy reactor physics tools, and require specific treatments. This work focuses in particular on the analysis of the effect of the delayed neutron precursors drift and the impact of liquid fluid thermal expansion and compressibility in postulated criticality excursion transients in fast-spectrum MSRs. A new modeling tool based on a Monte Carlo approach for neutronics (Serpent code) coupled to a Computational Fluid Dynamic (CFD) analysis (OpenFOAM) was developed to obtain accurate modeling and simulation of these phenomena. The development of the Serpent Monte Carlo code [1] at VTT in the past few years has made this code particularly attractive for performing multiphysics studies. The availability of a flexible multiphysics interface, on-the-fly Doppler broadening and density-based collision rejection, and Delta-tracking, proved of paramount importance for the computationally efficient performance of coupled Monte Carlo/CFD calculations [2]. OpenFOAM is a C++ multiphysics toolkit featured by automatic matrix construction and solution capabilities for scalar and vector partial differential equations (PDEs), adopting several possible differencing and interpolation schemes, based on the Finite-Volume method. The ease of implementing the constitutive equations of different physical phenomena makes OpenFOAM particularly suitable for the modeling of complex coupled phenomena. In the past, several research activities proposed the adoption of both Serpent and OpenFOAM for the modeling and simulation of MSRs and the associated fuel cycles. In this work, these tools have been internally coupled for the steady-state and transient analysis of fast-spectrum systems, accounting for the effect of delayed neutron precursors transport and the salt thermal expansion and compressibility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analyzing Residential Charging Demand for Light-Duty Electric Vehicles in Colorado: Preprint

The past decade has witnessed the rapid adoption of electric vehicles (EVs). The momentum is expected to continue with strong support from the government and industry. Rapid EV adoption brings significant charging demand to the power grid, causing additional stress and non-negligible risks to the already-aging power grid. To help power grid operators understand the impacts of EV home charging on the grid and identify risk factors, this study presents a data-driven residential charging demand analysis for light-duty vehicles. This study considers two real-world grid service regions in Colorado and merges multiple data sources and state-of-the-art tools that characterize EV adoption projections, vehicle travel patterns, seasonal variations, residential charging accessibility, ambient temperature impact, EV charging behaviors, grid utility customers, vehicle registration, and household-level EV charging demand distribution. We characterize potential residential charging demand in 2030 for two regions within the state of Colorado: Boulder and Aurora. We project that EVs will be 26% of the light-duty vehicle population in Boulder and 16% in Aurora. Charging demand is characterized for ten power grid feeders (five for each study region). Across the ten feeders, peak total EV charging powers during wintertime range from less than 1 MW to more than 4 MW.

ADVANCED PROPULSION SYSTEMS↗

Fine Temperature Grid Continuous Energy Cross Section Generation for Monte Carlo Analysis of Xe-100 Design

The standard “A Compact ENDF (ACE)” data libraries used by Monte Carlo based reactor physics codes calculations are provided by Los Alamos National Laboratory (LANL) with a temperature interval mostly of 300 K (e.g. 300 K, 600 K, 900 K) for the cross sections and between 100 K and 200 K for the thermal scattering libraries (TSL). However, some codes such as MCNP lack capability to perform on-the-fly temperature interpolation during simulation both for neutron and TSL cross-sections. To evaluate the impact related to Doppler broadening and spectrum shift associated with TSL changes, this paper explores the potential of adopting a temperature grid finer than the ones contained in the standard data libraries. A 50 K temperature grid was employed to quantify the error in neutronics calculations due to temperature grid resolution. This was achieved by comparing the results of this study (50 K temperature interval) against the results obtained with standard data libraries (>100 K temperature interval). While the adopted grid primarily relies on the ENDF/B-VII.1 library, for neutron cross-sections, it utilizes ENDF/B-VIII.0 library for TSL. The analyses confirmed that the accuracy of neutronics calculations is satisfactory when using a 50 K temperature grid. Notably, adopting a 50 K temperature grid, as opposed to standard libraries or coarser temperature grids, could lead to a difference of no more than a few hundred pcm in dk for both fresh fuel and burnt fuel. The most sensitive reaction type to the temperature grid was as expected identified as the capture cross-section of U-238.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Tool to Incorporate Non-Energy Impacts in Energy Efficiency Investment Decision Making for Firms

Energy efficiency is a key demand-side strategy for sustainability, recently identified by the United States Department of Energy as a pillar of industrial decarbonization. The increased focus on decarbonization and the requirement for efficiency to enable electrification, another decarbonization pillar, due to the spark spread between natural gas and electricity prices, make energy efficiency increasingly relevant. Still, industries face challenges in adopting energy efficiency measures. Researchers have long found a gap in adoption of even those measures with a profitable net present value, attributed to lack of strategic value among other barriers (see for rigorous exploration and taxonomy). One solution to facilitate energy efficiency projects is the inclusion of non-energy impacts, as this has been shown to double potential deployment of such projects at system level. Energy efficiency can provide valuable benefits outside of simple operating cost reductions, from decreased pollution to enhanced productivity. The inclusion of these benefits in decision making assessments faces hurdles due to inconsistency of ancillary benefits across projects, difficulties in quantifying impacts and the need for additional measurement to quantify them. The decision-making tools to support this have been designed primarily for the European context. We begin with a stakeholder engagement process to better characterize the U.S. decision making process surrounding adoption of energy efficiency investments. Characterization of non-energy impacts has developed substantially over recent decades. Cagno et al. provided a framework for studying the applicability of these impacts to energy efficiency projects, listing 120 key performance indicators focused mainly on reductions of costs/harms. Other researchers have included impacts on the strategic and revenue side that can be merged into this framework as well. We seek a tractable set of impacts that can be included in a decision-making tool in the US, and as such are well suited to US industry, management and decision making processes. We also seek to understand how to best quantify or characterize these impacts. This work will demonstrate the results of a survey conducted among US manufacturing industry decision makers to assess the decision making landscape of stakeholders as well as the most relevant performance indicators for energy efficiency projects.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Integrated Building Energy Systems Design Considering Storage Technologies

The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic, as well as environmental attraction of micro-generation systems (e.g., PV or fuel cells with or without CHP) and contribute to enhanced demand response. The interactions among PV, solar thermal, and storage systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of storage technologies on demand response and CO2 emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that can pursue two strategies as its objective function. These two strategies are minimization of its annual energy costs or of its CO2 emissions. The problem is solved for a given test year at representative customer sites, e.g., nursing homes, to obtain not only the optimal investment portfolio, but also the optimal hourly operating schedules for the selected technologies. This paper focuses on analysis of storage technologies in micro-generation optimization on a building level, with example applications in New York State and California. It shows results from a two-year research projectperformed for the U.S. Department of Energy and ongoing work. Contrary to established expectations, our results indicate that PV and electric storage adoption compete rather than supplement each other considering the tariff structure and costs of electricity supply. The work shows that high electricity tariffs during on-peak hours are a significant driver for the adoption of electric storage technologies. To satisfy the site's objective of minimizing energy costs, the batteries have to be charged by grid power during off-peak hours instead of PV during on-peak hours. In contrast, we also show a CO2 minimization strategy where the common assumption that batteries can be charged by PV can be fulfilled at extraordinarily high energy costs for the site.

25 ENERGY STORAGE↗

The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG&E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

03 NATURAL GAS↗

Simulation of the GHG Abatement Potentials in the U.S. Building Sector by 2050

Given the substantial contribution of the U.S. building sector to national carbon emissions, it is clear that to address properly the issue of climate change, one must first consider innovative approaches to understanding and encouraging the introduction of new, low-carbon technologies to both the commercial and residential building markets. This is the motivation behind the development of the Stochastic Lite Building Module (SLBM), a long range, open source model to forecast the impact of policy decisions and consumer behavior on the market penetration of both existing and emerging building technologies and the resulting carbon savings. The SLBM, developed at Lawrence Berkeley National Laboratory (LBNL), is part of the Stochastic Energy Deployment System (SEDS) project, a multi-laboratory effort undertaken in conjunction with the National Renewable Energy Laboratory (NREL), Pacific Northwest National Laboratory (PNNL), Argonne National Laboratory (ANL) and private companies. The primary purpose of SEDS is to track the performance of different U.S. Department of Energy (USDOE) Research and Development (R&D) activities on technology adoption, overall energy efficiency, and CO{sub 2} reductions throughout the whole of the U.S. economy. The tool is fundamentally an engineering-economic model with a number of characteristics to distinguish it from existing energy forecasting models. SEDS has been written explicitly to incorporate uncertainty in its inputs leading to uncertainty bounds on the subsequent forecasts. It considers also passive building systems and their interactions with other building service enduses, including the cost savings for heating, cooling, and lighting due to different building shell/window options. Such savings can be compared with investments costs in order to model real-world consumer behavior and forecast adoption rates. The core objective of this paper is to report on the new window and shell features of SLBM and to show the implications of various USDOE research funding scenarios on the adoption of these and other building energy technologies. The results demonstrate that passive technologies contain significant potential for carbon reductions - exceeding 1165 Mt cumulative savings between 2005 and 2050 (with 50% likelihood) and outperforming similar R&D funding programs for distributed photovoltaics and high efficiency solid-state lighting.

25 ENERGY STORAGE↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial process heat decarbonization: A user-centric perspective

Eliminating greenhouse gas emissions from industrial process heat (IPH) is considered a key element of decarbonizing the overall industrial sector. However, industrial users and the processes by which they may adopt and implement technologies for decarbonization have largely been overlooked in the United States by an emphasis on developing and commercializing new technologies. While recent deployment and demonstration programs are an indication that decarbonization policy is beginning to acknowledge industrial users, little research has been conducted to understand how users mediate technical and nontechnical requirements to decarbonize IPH. Our exploratory analysis uses interviews with industry representatives and document analysis to begin developing a user-centric perspective. Here, we find that successful adoption and implementation of decarbonized IPH technologies may require adaptation to diverse and potentially unique combinations of user requirements and local contexts. Instead of pursuing "crosscutting" IPH technologies, a more effective and expeditious approach may be to develop crosscutting decision-making that spans multiple technologies. This approach may offer unexplored opportunities to improve demonstration and deployment programs, but more user-centric research is needed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and Energy Cost Savings Analysis of the IECC for Commercial Buildings

The purpose of this analysis is to assess the relative energy and energy cost performance of commercial buildings designed to meet the requirements found in the commercial energy efficiency provisions of the International Energy Conservation Code (IECC). Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. As many states have historically adopted the IECC for both residential and commercial buildings, PNNL has evaluated the impacts of the commercial provisions of the 2006, 2009, and 2012 editions of the IECC. PNNL also compared energy performance with corresponding editions of ANSI/ASHRAE/IES Standard 90.1 to help states and local jurisdictions make informed decisions regarding model code adoption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distributed Generation Market Demand Model (dGen): Documentation

The Distributed Generation Market Demand model (dGen) is a geospatially rich, bottom-up, market-penetration model that simulates the potential adoption of distributed energy resources (DERs) for residential, commercial, and industrial entities in the continental United States through 2050. The National Renewable Energy Laboratory (NREL) developed dGen to analyze the key factors that will affect future market demand for distributed solar, wind, storage, and other DER technologies in the United States. The new model builds off, extends, and replaces NREL's SolarDS model (Denholm et al. 2009a), which simulates the market penetration of distributed PV only. Unlike the SolarDS model, dGen can model various DER technologies under one platform--it currently can simulate the adoption of distributed solar (the dSolar module) and distributed wind (the dWind module) and link with the ReEDS capacity expansion model (Appendix C). The underlying algorithms and datasets in dGen, which improve the representation of customer decision making as well as the spatial resolution of analyses (Figure ES-1), also are improvements over SolarDS.

17 WIND ENERGY↗

Compliance Verification Paths for Residential and Commercial Energy Codes

Conformity assessment is a term used to describe the processes followed to demonstrate that a product, service, management system, or body meets specified requirements, such as standards, codes, laws, regulations, or other criteria. With respect to energy codes, conformity assessment includes all activities and tasks undertaken by any number of entities to ensure that the provisions of an adopted energy code are achieved at a designated point in time. This report identifies and discusses conformity assessment activities and provides guidance for developing new or adjusting existing ways of verifying compliance. In addition, this report looks at different ways to ensure that the energy-efficiency goals of an adopted code or standard are achieved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Storage Futures Study: Distributed Solar and Storage Outlook: Methodology and Scenarios

This report is one in a series of NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. The research findings and supporting data will be published as a series of reports, with each report being released on its completion. The table below lists the specific research topics planned for examination under the SFS and the associated publication formats. This report, the fourth in the SFS series, provides a set of scenarios for cost-effectiveness and customer adoption for a range of scenarios that include future technology costs and valuation of backup power. The SFS series provides data and analysis in support of the U.S. Department of Energy’s Energy Storage Grand Challenge, a comprehensive program to accelerate the development, commercialization, and utilization of next-generation energy storage technologies and sustain American global leadership in energy storage. The Energy Storage Grand Challenge employs a use case framework to ensure storage technologies can cost-effectively meet specific needs, and it incorporates a broad range of technologies in several categories: electrochemical, electromechanical, thermal, flexible generation, flexible buildings, and power electronics. More information, any supporting data associated with this report, links to other reports in the series, and other information about the broader study are available at https://www.nrel.gov/analysis/storage-futures.html.

25 ENERGY STORAGE↗

Electric Vehicle Managed Charging: Forward-Looking Estimates of Bulk Power System Value

When and where electric vehicle charging occurs has significant implications for power systems supporting widespread electric vehicle deployment with high shares of wind and solar generation. Numerous studies have estimated the value of scheduling or otherwise managing electric vehicle charging in such power systems. This study improves on those earlier works by leveraging detailed simulation models for electric vehicle adoption, electric vehicle use, electric vehicle charging, and bulk power system operations; and linking them with methods for describing charging flexibility at both the individual vehicle and aggregate levels. This study closely analyzes electric vehicle managed charging (EVMC) performance along the dimensions of flexibility type (within-charging session or within-week scheduling), dispatch mechanism (direct load control or one of several price-based mechanisms), and participation rate, under the assumptions of ubiquitous chargers and all trips completed on time. The study is located in a passenger light-duty vehicle adoption scenario with 100% electric vehicle sales by 2035, and in an envisioned 2038 New England power system for which within-region generation is 84% clean.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Projecting California Light-Duty Vehicle Attributes (2019-2035)

In this report, we estimated a set of future vehicle attribute scenarios for new light-duty vehicles for the California market using the Automotive Deployment Options Projection Tool (ADOPT). ADOPT starts simulations with all existing vehicle makes and models and endogenously creates new vehicle models over time based on assumed technology improvements and market conditions. For this study, we simulated four scenarios with varied technology, policy, and electric vehicle infrastructure assumptions. We aggregated simulation results into up to 30 vehicle classes (covering size and price classifications) for each powertrain, for six powertrains. We simulated model years 2019 to 2035. We present results for four vehicle attributes: vehicle acceleration, fuel economy (including electric and gasoline for plug-in hybrid electric vehicles [PHEVs]), vehicle range, and vehicle purchase price. We also present results showing the estimated number of vehicle models available in each vehicle class over time. In the Mid scenario, which contains conditions between our most conservative and most optimistic assumptions for emerging electric and hydrogen technologies, we observe improvements in acceleration, range (for battery-electric vehicles [BEVs]), and vehicle purchase price for electric and hydrogen powertrains. In some cases, we project that consumer preferences lead to trade-offs between vehicle attributes, such as reduced fuel economy in exchange for improved acceleration. Conventional vehicles show modest improvements in fuel economy in these scenarios due to the high numbers of BEV and PHEV sales, which reduce the improvements required in conventional vehicles to meet fleet fuel economy standards. In scenarios with advanced technology assumptions (including reduced battery price and improved energy density), we observe further improvements in BEV range and price relative to the improvements in the Mid scenario.

33 ADVANCED PROPULSION SYSTEMS↗

National Cost-effectiveness of ANSI/ASHRAE/IES Standard 90.1-2016

The purpose of this analysis is to examine the cost-effectiveness of the 2016 edition of ANSI/ASHRAE/IES Standard 90.1 (ASHRAE 2016). Standard 90.1 is developed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard Standing Project Committee (SSPC) 90.1. It is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2013 to 90.1-2016, as applied in commercial buildings across the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of ASHRAE Standard Standing Project Committee (SSPC) 90.1. The ASHRAE process, however, does not include analysis of the cost-effectiveness of the entire package of addenda from one edition of the standard to the next, which is of particular interest to adopting State and local governments. Providing States with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1. To establish the cost-effectiveness of Standard 90.1-2016, three main tasks were addressed: (1) Identification of building elements impacted by the updated standard; (2) Allocation of associated installation, maintenance, and replacement costs; and (3) Cost-effectiveness analysis of required changes In addition to installation, maintenance, and replacement costs, energy cost differences were needed to determine cost-effectiveness. The energy costs for each edition of Standard 90.1 were determined previously under the development of Standard 90.1-2016, as described below. The current analysis builds on the previous PNNL analysis (as outlined in Section 5.2) of the energy use and energy cost saving impacts of Standard 90.1-2016 compared to previous editions. The overall energy savings analysis of Standard 90.1 utilized a suite of 16 prototype EnergyPlus building models in 15 climate locations representing all eight U.S. climate zones. Detailed methodology and overall energy saving results from Standard 90.1-2016 are documented in the DOE technical report titled Energy Savings Analysis: ANSI/ASHRAE/IES Standard 90.1-2016 (DOE. 2018b).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Codes Resource Guide: Commercial Buildings for Architects

The Commercial Buildings for Architects Resource Guide provides key energy code information tailored for architects, and was designed in partnership with the American Institute of Architects (AIA). It offers guidance on how architects can support adoption of new or updated energy codes, and resources needed to enable compliance with the adopted code. The guide includes information on the importance of architects in the development and compliance verification processes, the interface between codes and the design process, design and compliance tools, and building construction and commissioning. It also includes many other resources to help architects understand the important role that the design process of energy codes plays in addressing our energy, economic and environmental challenges.

Code development and adoption, high-performance bu↗