Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analyst”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Enabling coordinated, distributed development of scientific software: A research agenda for adapting a team of teams approach

The “team of teams” concept is a strategy for coordinating activities within and across organizations, developed by General Stanley McChrystal and his colleagues based on their experiences leading the Joint Special Operations Task Force in Iraq from 2003-2008. These experiences, and the lessons learned from them, are recounted in the books Team of Teams (McChrystal 2015) and One Mission (Fussell 2017) (the authors and contributors to these books will hereafter be jointly referred to as McChrystal et al.). Essentially, their story is one of rapidly adapting a rigid, siloed organization to defeat the flexible, resilient, and fast-moving network of Al Qaeda in Iraq. As described in the books, when McChrystal took over the Task Force, he found a collection of highly competent, efficient teams of analysts and warfighters which nonetheless had difficulty operating in a unified manner due to close internal ties, distrust of outsiders, bureaucratic stove pipes, and cultural differences stemming from the diverse organizations Task Force teams were affiliated with, including Army Special Forces, CIA, and NSA.

97 MATHEMATICS AND COMPUTING↗

RETRO RX

RETRO Rx is an R&D 100 Gold Award-winning suite of tools that provides a new class of analytics in the space between traditional epidemiological models and unanalyzed spreadsheets of data. Unlike traditional models, these tools provide analysts, scientists, practitioners, and decision makers a way to easily and effectively do sophisticated analyses using a simple user interface. AIDO guides users at the early stages of a disease outbreak by comparing the current parameters to historic outbreaks. RED Alert constructs a broad historical picture of disease incidence (recent outbreak included) to detect disease reemergence at its earliest stages, locally and globally. RETRO Rx compiles data and presents analysis in a clear, concise visual format to support disease mitigation and prevention planning. Both are available currently as web-based apps. A prototype of the RED Alert mobile app with enhanced functionality is available for beta testing and AIDO mobile app development is planned.

59 BASIC BIOLOGICAL SCIENCES↗

Efficient Binary Static Code Data Flow Analysis Using Unsupervised Learning

The ever increasing need to ensure that code is reliably, efficiently and safely constructed has fueled the evolution of popular static binary code analysis tools. In identifying potential coding flaws in binaries, tools such as IDA Pro are used to disassemble the binaries into an opcode/assembly language format in support of manual static code analysis. Because of the highly manual and resource intensive nature involved with analyzing large binaries, the probability of overlooking potential coding irregularities and inefficiencies is quite high. In this paper, a light-weight data, unsupervised data flow methodology is described which uses highly-correlated data flow graph (CDFGs) to identify coding irregularities such that analysis time and required computing resources are minimized. Such analysis accuracy and efficiency gains are achieved by using a combination of graph analysis and unsupervised machine learning techniques which allows an analyst to focus on the most statistically significant flow patterns while performing binary static code analysis.

97 MATHEMATICS AND COMPUTING↗

Demand Driven Cycamore Archetypes

Future nuclear fuel cycle options may present advantages over today’s once-through fuel cycle. Nuclear fuel cycle simulation tools assess the performance of those fuel cycles as well as the dynamics of long-term technology transitions. In many nuclear fuel cycle simulation tools, it has historically been the responsibility of the user to manually define facility deployment schemes and all facility parameters. While this is straightforward in simple fuel cycles, transitions from one fuel cycle to another can be more complex. In particular, deployment schemes for supportive fuel cycle facilities beyond the reactor become complex if the analyst desires to avoid gaps in the nuclear fuel and power supply chain during those transition scenarios. As nuclear fuel cycle analysis approaches questions regarding the feasibility and performance of the deployment schemes and technology choices during technology transition, automation of this historically manual process is necessary. The main objective of this work was to develop and demonstrate Cyclus automation capabilities toward key nuclear fuel cycle transition scenarios. While deploying reactors to meet power demand is trivial, and existed in the earliest versions of CYCLUS, automated, predictive deployment and decommissioning of other facilities is more complex. These include mining, milling, enrichment, fuel fabrication, reprocessing, and others. For example, a balanced closed fuel cycle may require ensuring that there is enough fast reactor fuel for their operation and may drive deployment of a fleet of light water reactors. This concern comprises the main challenge that drove the project effort. The Demand-Driven Cycamore Archetype project (NEUP-FY16-10512) aimed to develop CYCAMORE demand-driven deployment capabilities and thereby automate transition scenario definition. The developed software package, d3ploy, in the form of a CYCLUS Institution agent, deploys Facilities to meet the front-end and back-end demands of the fuel cycle. The University of South Carolina and the University of Illinois applied multiple algorithmic approaches to this challenge. This project developed an in situ demand-driven development schedule calculation through non-optimizing, deterministic-optimizing, and stochastic-optimizing algorithms as CYCLUS archetypes and demonstrated these new archetypes in program-supporting fuel cycle transition scenarios. Both objectives were achieved. This report documents the results and deliverables obtained toward these achievements in detail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Adaptive Self-Tuning of Signal Detection Parameters

The quality of automatic detections from sensor networks depends on a large number of data processing parameters that interact in complex ways. The largely manual process of identifying effective parameters is painstaking and does not guarantee that the resulting controls are the optimal configuration settings, yet achieving superior automatic detection of events is closely related to these parameters. We present an automated sensor tuning (AST) system that tunes effective parameter settings for each sensor detector to the current state of the environment by leveraging cooperation within a neighborhood of sensors. After a stabilization period, the AST algorithm can adapt in near real-time to changing conditions and automatically self-tune a signal detector to identify (detect) only signals from events of interest. The overall goal is to reduce the number of missed legitimate event detections and the number of false event detections. Our current work focuses on reducing false signal detections early in the seismic signal processing pipeline, which leads to fewer false events and has a significant impact on reducing analyst time and effort. Applicable both for existing sensor performance boosting and new sensor deployment, this system provides an important new method to automatically tune complex remote sensing systems. Systems tuned in this way will achieve better performance than is currently possible by manual tuning, and with much less time and effort devoted to the tuning process. With ground truth on detections from a seismic sensor network monitoring the Mount Erebus Volcano in Antarctica, we show that AST increases the probability of detection while decreasing false alarms.

58 GEOSCIENCES↗

New Predictive Capabilities for Nuclear Weapons in Composite Fires

The prevalence of flammable carbon-based composite airframe materials and their use in high-temperature nuclear weapon re-entry systems requires analysts to address the abnormal thermal environment hazards associated with composite material fires. These fires tend to burn very differently than conventional fuel fires, usually burning less intensely, but much longer. This could lead to challenges in understanding margins in classic safety themes. The technical challenges in modeling the phenomena associated with these new types of fires are considerable, but new models have been developed. Their predictions have been compared with well-documented measurements of a vertical porous burner fire, known as a "wall fire" (a "wall-fire" validation simulation is reflected in the figures below). These measurements were conducted at FMGlobal, a mutual insurance company with a strong fire risk management program, as part of an ongoing collaboration between Sandia and FMGlobal. To date, the "wall-fire" scenario has been set up and initial model assessments with grid refinement studies have been conducted focusing on mesh resolutions suitable for full weapon system simulations. This work will continue with further verification and validation tasks assessing the predictions of the new model. Future work will address specific aspects of the wall models that are lacking in their predictive ability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Extent-of-Condition Review of Electrical Events Fiscal Year 2019

Sandia National Laboratories has experienced a number of electrical events in recent years. A careful examination of data shows that for the third year in a row, two of the three most frequently categorized Occurrence Reporting and Processing System (ORPS)-reportable event types were unexpected or unintended personal contact with a hazardous energy source and a failure to follow a prescribed hazardous energy control process, as defined in the occurrence reporting criteria of DOE Order 232.2A, Occurrence Reporting and Processing of Operations Information, 2D(1) and 2D(2). Sandia policy CA001.2, Identify and Manage Issues, requires an extent-of-condition review for any high-level reportable occurrence, and the analysts were tasked to perform this EOC in light of high-level reportable occurrence NA-SS-SNL-1000-2019- 0007, Contact with Electrical Energy During Marx Capacitor Troubleshooting. This extent of condition not only evaluated the 10 reportable electrical occurrences for Fiscal Year 2019, but also looked at 11 other related events: those involving control of hazardous energy and electrical events associated with less than hazardous energy.1 This Extent-of-Condition report makes several observations, conclusions, and recommendations for improvement.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SIERRA Code Coupling Module: Arpeggio User Manual - Version 4.56

The SNL Sierra Mechanics code suite is designed to enable simulation of complex multiphysics scenarios. The code suite is composed of several specialized applications which can operate either in standalone mode or coupled with each other. Arpeggio is a supported utility that enables loose coupling of the various Sierra Mechanics applications by providing access to Framework services that facilitate the coupling. More importantly Arpeggio orchestrates the execution of applications that participate in the coupling. This document describes the various components of Arpeggio and their operability. The intent of the document is to provide a fast path for analysts interested in coupled applications via simple examples of its usage.

97 MATHEMATICS AND COMPUTING↗

Operationally-Relevant Cyber Situational Awareness Tool Development.

Research was undertaken to gain an understanding of the interplay between cyber security professionals and the software tools utilized in performing their jobs. Substantial investments are devoted to purchasing and developing software tools targeting cyber security operations. However, development is largely based on anecdotal knowledge concerning the work processes, cognitive demands, and the needs and requirements of cyber security analysts. The current study first characterized the workflow of a Cyber Security Incidence Response (CSIRT) team, including their use of software tools, and instantiated this workflow within a simulation model. Next, data was collected during cyber security training exercises reflecting the use of software tools. It was discovered that while cyber security professionals rely heavily on specialized software tools, their jobs require that they effectively integrate the use of specialized software tools with the use of general- purpose software tools.

97 MATHEMATICS AND COMPUTING↗

Benchmarking Utility-Scale PV Operational Expenses and Project Lifetimes: Results from a Survey of U.S. Solar Industry Professionals

This paper draws on a survey of solar industry professionals and other sources to clarify trends in the expected useful life and operational expenditure (OpEx) of utility-scale photovoltaic (PV) plants in the United States. Solar project developers, sponsors, long-term owners, and consultants have increased project-life assumptions over time, from an average of ~21.5 years in 2007 to ~32.5 years in 2019. Current assumptions range from 25 years to more than 35 years depending on the organization; 17 out of 19 organizations surveyed or reviewed use 30 years or more. Levelized, lifetime OpEx estimates have declined from an average of ~$\$$35/kW DC -yr for projects built in 2007 to an average of ~$\$$17/kW DC -yr in 2019. Across 13 sources, the range in average lifetime OpEx for projects built in 2019 is broad, from $\$$13 to $\$$25/kW DC -yr. Operations and maintenance (O&M) costs—one component of OpEx—have declined precipitously in recent years, to $\$$5-8/kW DC -yr in many cases. Property taxes and land lease costs are highly variable across sites, but on average are—together—of similar magnitude. Other OpEx line items include security, insurance, and asset management. Given 2007-2009 values for not only project life and OpEx but also other drivers of the levelized cost of energy (LCOE, excluding the investment tax credit), the LCOE for utility-scale PV projects built from 2007 through 2009 averaged $\$$305 /MWh. Using 2019 values for all parameters yields an average LCOE of $\$$51 /MWh. The decline in LCOE from $\$$305 /MWh to $\$$51 /MWh was predominantly caused by reductions in up-front expenditures (and, to a much lesser extent, by changes in capacity factors, financing costs, and tax rates), but 9% ($\$$22 /MWh) of the overall decline is due to improvements in project life and OpEx. Project life extensions and OpEx reductions have had similarly sized impacts on LCOE over this period, at $\$$11 /MWh each. Had project life and OpEx not improved over the last decade, LCOE in 2019 would have instead been $\$$73 /MWh—43% higher. Given the limited quantity and comparability of previously available data on these cost drivers, the data and trends presented here may inform assumptions used by electric system planners, modelers, and analysts. The results may also provide useful benchmarks to the solar industry, helping developers and assets owners compare their expectations for project life and OpEx with those of their peers.

14 SOLAR ENERGY↗

3D Crustal Tomography Model of Utah

The ability to accurately locate seismic events is necessary for treaty monitoring. When using techniques that rely on the comparison of observed and predicted travel times to obtain these locations, it is important that the estimated travel times and their estimated uncertainties are also accurate. The methodology of Ballard et al. (2016a) has been used in the past to generate an accurate 3D tomographic global model of compressional wave slowness (the SAndia LoS Alamos 3D tomography model, i.e. SALSA3D). To re-establish functionality and to broaden the capabilities of the method to local distances, we have applied the methodology of Ballard et al. (2016a) to local data in Utah. This report details the results of the initial model generated, including relocations performed using analyst picked mining events at West Ridge Mine and three ground-truth events at Bingham Mine. We were successfully able to generate a feasible tomography model that resulted in reasonable relocations of the mining events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A User’s Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.3 is a program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of codes originally used for plate temperatures, hence “PLTEMP”, developed at Argonne National Laboratory over several decades. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. Depending upon the heat transfer method selected, the temperature solution is effectively 2-dimensional or 3-dimensional (Appendix XV). It begins with a solution across all coolant channels and fuel plates or tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available to determine safety margins such as onset-of-nucleate boiling ratio(ONBR), departure from nucleate boiling ratio (DNBR), and onset of flow instability ratio (OFIR). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

The document compiles in a single volume the verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. The verification of sixteen capabilities of the PLTEMP/ANL Version 4.3 code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis are described and documented. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL verification works that are available in the open literature are simply referenced and not included in the document. PLTEMP/ANL has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Side Channel Considerations for SHA-512

We consider a theoretical side-channel attack on SHA-512; the attack should easily generalize to other algorithms in the SHA-2 family. Rather than looking at a side-channel attack on an HMAC, which has been done in various papers, we assume that the targeted device is applying the hash function as a pseudo-random function (prf) in order to generate a secret key from a secret seed, as recommended by NIST. The analyst uses side-channel information to try to recover the secret seed. We use entropy/information theory to show how one might judge whether or not a side-channel attack might be possible and/or feasible, and we show how the design of the implementation can affect the feasibility of an attack.

97 MATHEMATICS AND COMPUTING↗

Ultra High Performance Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry and Fisher Ratio Analysis for Discovery-Based Analysis

The ability to discover minute differences between samples or sample classes for ultrahigh performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) can be a challenging endeavor especially when these differences are not known a priori. Indeed a typical UHPLC-QTOF analysis time of ~15 minutes can generate over 4 gigabytes of information for a single sample. Implementation of chemometrics such as Fisher ratio (F-ratio) analysis will allow the analyst to quickly and precise probe the chemical differences between different samples or sample classes. F-ratio analysis can be used to find sample or sample class distinguishing compounds reducing the 5 gigabytes of information into a simple, yet informative hit list. Moreover through combinatorial rearrangement, it is possible to determine a F-ratio threshold to separate the real and non-real hits. The F-ratio software presented herein is a semi-automated algorithm that processes the raw, exported .csv files from the SCIEX 500R QTOF in as little as 30 seconds. While further research is needed to modify and perfect the software to deal with high resolution mass spectra precise to 0.0001 Daltons, the current software, precise to 0.1 Da, is able to find significant chemical differences despite some of them being at extremely low concentrations nearing the limit of detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗