Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPETENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Runtime Scheduling Policies for Distributed Graph Algorithms

In this paper we explore scheduling and runtime system support for unordered distributed graph computations that rely on optimistic (speculative) execution. Performance of such algorithms is impacted by two competing trends: the higher degree of parallelism enabled by optimistic execution in turn requires substantial runtime support. To address the potentially high overhead and scheduling complexity introduced by the runtime, we investigate customizable scheduling policies that augment the scheduler of the underlying runtime to adapt it to a specific graph application. We present several implementations of Distributed Control (DC), a data-driven unordered approach with work prioritization and demonstrate that customizable scheduling policies result in the most efficient implementation, outperforming the well-known -stepping Single-Source Shortest Paths (SSSP) and Jones-Plassmann vertex-coloring algorithms. We apply two scheduling techniques, flow control and adaptive frequency of network progress, which allow application-level control over the balance of domain work and the runtime work. Experimental results show the benefit of such application-aware scheduling for irregular distributed graph algorithms.

Firoz, Jesun S.↗

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test: Preprint

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiplemechanisms. The extent of the voltage bias degradation is linked to the leakage current or coulombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstratemodule durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative biasapplied to the active layer.

14 SOLAR ENERGY↗

Rubis CO selection using the vigorously aerobic and metabolically versatile bacterium Ralstonia eutropha

Recapturing atmospheric CO 2 is key to reducing global warming and increasing biological carbon availability. Ralstonia eutropha is a biotechnologically useful aerobic bacterium that uses the Calvin–Benson–Bassham ( CBB ) cycle and the enzyme ribulose 1,5‐bisphosphate carboxylase/oxygenase (Rubis CO ) for CO 2 utilization, suggesting that it may be a useful host to bioselect Rubis CO molecules with improved CO 2 ‐capture capabilities. A host strain of R. eutropha was constructed for this purpose after deleting endogenous genes encoding two related Rubis CO s. This strain could be complemented for CO 2 ‐dependent growth by introducing native or heterologous Rubis CO genes. Mutagenesis and suppressor selection identified amino acid substitutions in a hydrophobic region that specifically influences Rubis CO 's interaction with its substrates, particularly O 2 , which competes with CO 2 at the active site. Unlike most Rubis CO s, the R. eutropha enzyme has evolved to retain optimal CO 2 ‐fixation rates in a fast‐growing host, despite the presence of high levels of competing O 2 . Yet its structure‐function properties resemble those of several commonly found Rubis CO s, including the higher plant enzymes, allowing strategies to engineer analogous enzymes. Because R. eutropha can be cultured rapidly under harsh environmental conditions (e.g., with toxic industrial flue gas), in the presence of near saturation levels of oxygen, artificial selection and directed evolution studies in this organism could potentially impact efforts toward improving Rubis CO ‐dependent biological CO 2 utilization in aerobic environments. Enzymes d ‐ribulose 1,5‐bisphosphate carboxylase/oxygenase, EC 4.1.1.39 ; phosphoribulokinase, EC 2.7.1.19

Satagopan, Sriram↗

Forecasting changes in water quality in rivers associated with growing biofuels in the Arkansas-White-Red river drainage, USA

We study that the mid-section of the Arkansas-White-Red (AWR) river basin near the 100 th parallel is particularly promising for sustainable biomass production using cellulosic perennial crops and residues. Along this longitudinal band, precipitation becomes limiting to competing crops that require irrigation from an increasingly depleted groundwater aquifer. In addition, the deep-rooted perennial, switchgrass, produces modest-to-high yields in this region with minimal inputs and could compete against alternative crops and land uses at relatively low cost. Previous studies have also suggested that switchgrass and other perennial feedstocks offer environmentally benign alternatives to corn and corn stover. However, water quality implications remain a significant concern for conversion of marginal lands to bioenergy production because excess nutrients produced by agriculture for food or for energy contribute to eutrophication in the dead-zone in the Gulf of Mexico. This study addresses water quality implications for the AWR river basin. We used the SWAT model to compare water quality in rivers draining a baseline, pre-cellulosic-bioenergy and post-cellulosic-bioenergy landscapes for 2022 and 2030. Simulated water quality responses varied across the region, but with a net tendency toward decreased amounts of nutrient and sediment, particularly in subbasins with large areas of bioenergy crops in 2030 future scenarios. We conclude that water quality is one aspect of sustainability for which cellulosic bioenergy production in this region holds promise.

09 BIOMASS FUELS↗

Stacking AsFMT overexpression with BdPMT loss of function enhances monolignol ferulate production in Brachypodium distachyon

To what degree can the lignin subunits in a monocot be derived from monolignol ferulate (ML-FA) conjugates? This simple question comes with a complex set of variables. Three potential requirements for optimizing ML-FA production are as follows: (1) The presence of an active FERULOYL-CoA MONOLIGNOL TRANSFERASE (FMT) enzyme throughout monolignol production; (2) Suppression or elimination of enzymatic pathways competing for monolignols and intermediates during lignin biosynthesis; and (3) Exclusion of alternative phenolic compounds that participate in lignification. A 16-fold increase in lignin-bound ML-FA incorporation was observed by introducing an AsFMT gene into Brachypodium distachyon. On its own, knocking out the native p-COUMAROYL-CoA MONOLIGNOL TRANSFERASE (BdPMT) pathway that competes for monolignols and the p-coumaroyl-CoA intermediate did not change ML-FA incorporation, nor did partial loss of CINNAMOYL-CoA REDUCTASE1 (CCR1) function, which reduced metabolic flux to monolignols. However, stacking AsFMT into the Bdpmt-1 mutant resulted in a 32-fold increase in ML-FA incorporation into lignin over the wild-type level.

59 BASIC BIOLOGICAL SCIENCES↗

Balancing Power Absorption and Fatigue Loads in Irregular Waves for an Oscillating Surge Wave Energy Converter

The aim of this paper is to describe how to control the power-to-load ratio of a novel wave energy converter (WEC) in irregular waves. The novel WEC that is being developed at the National Renewable Energy Laboratory combines an oscillating surge wave energy converter (OSWEC) with control surfaces as part of the structure; however, this work only considers one fixed geometric configuration. This work extends the optimal control problem so as to not solely maximize the time-averaged power, but to also consider the power-take-off (PTO) torque and foundation forces that arise because of WEC motion. The objective function of the controller will include competing terms that force the controller to balance power capture with structural loading. Separate penalty weights were placed on the surge-foundation force and PTO torque magnitude, which allows the controller to be tuned to emphasize either power absorption or load shedding. Results of this study found that, with proper selection of penalty weights, gains in time-averaged power would exceed the gains in structural loading while minimizing the reactive power requirement.

16 TIDAL AND WAVE POWER↗

Tuning of Nacelle Feedback Gains for Floating Wind Turbine Controllers Using a Two-DOF Model

Designing a collective blade pitch controller for floating offshore wind turbines (FOWTs) poses unique challenges due to the interaction of the controller with the dynamics of the platform. The controller must also handle the competing objectives of power production performance and fatigue load management. Existing solutions either detune the controller with the result of slowed response, make use of complicated tuning methods, or incorporate a nacelle velocity feedback gain. With the goal of developing a simple control tuning method for the general FOWT researcher that is easily extensible to a wide array of turbine and hull configurations, this last idea is built upon by proposing a simple tuning strategy for the feedback gain. This strategy uses a two degree-of-freedom (DoF) turbine model that considers tower-top fore-aft and rotor angular displacements. For evaluation, the nacelle velocity term is added to an existing gain scheduled proportional-integral controller as a proportional gain. The modified controller is then compared to baseline land-based and detuned controllers on an example system for several load cases. First-pass results are favorable, demonstrating how researchers can use the proposed tuning method to efficiently schedule gains for adequate controller performance as they investigate new FOWT configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Integrated Energy-Water Planning in the Western and Texas Interconnections

While long-term regional electricity transmission planning has traditionally focused on cost, infrastructure utilization, and reliability, issues concerning the availability of water represent an emerging issue. Thermoelectric expansion must be considered in the context of competing demands from other water use sectors balanced with fresh and non-fresh water supplies subject to climate variability. An integrated Energy-Water Decision Support System (DSS) is being developed that will enable planners in the Western and Texas Interconnections to analyze the potential implications of water availability and cost for long-range transmission planning. The project brings together electric transmission planners (Western Electricity Coordinating Council and Electric Reliability Council of Texas) with western water planners (Western Governors’ Association and the Western States Water Council). This paper lays out the basic framework for this integrated Energy-Water DSS.

electricity↗

Control of polymorphism during epitaxial growth of hyperferroelectric candidate LiZnSb on GaSb (111)B

A major challenge for ferroelectric devices is the depolarization field, which competes with and often destroys long-range polar order in the limit of ultrathin films. Recent theoretical predictions suggest a new class of materials, termed hyperferroelectics, that should be robust against the depolarization field and enable ferroelectricity down to the monolayer limit. Here, the authors demonstrate the epitaxial growth of hexagonal LiZnSb, one of the hyperferroelectric candidate materials, by molecular-beam epitaxy on GaSb (111)B substrates. Due to the high volatility of all three atomic species, they find that LiZnSb can be grown in an adsorption-controlled window, using an excess zinc flux. Within this window, the desired polar hexagonal phase is stabilized with respect to a competing cubic polymorph, as revealed by x-ray diffraction and transmission electron microscopy measurements. First-principles calculations show that for moderate amounts of epitaxial strain and moderate concentrations of Li vacancies, the cubic LiZnSb phase is lower in formation energy than the hexagonal phase, but only by a few millielectronvolts per formula unit. Therefore, they suggest that kinetics plays a role in stabilizing the desired hexagonal phase at low temperatures. Their results provide a path toward experimentally demonstrating ferroelectricity and hyperferroelectricity in a new class of ternary intermetallic compounds.

42 ENGINEERING↗

Integral dose conservation in radiotherapy

Treatment planners frequently modify beam arrangements and use IMRT to improve target dose coverage while satisfying dose constraints on normal tissues. The authors herein analyze the limitations of these strategies and quantitatively assess the extent to which dose can be redistributed within the patient volume. Specifically, the authors hypothesize that (1) the normalized integral dose is constant across concentric shells of normal tissue surrounding the target (normalized to the average integral shell dose), (2) the normalized integral shell dose is constant across plans with different numbers and orientations of beams, and (3) the normalized integral shell dose is constant across plans when reducing the dose to a critical structure. Using the images of seven patients previously irradiated for cancer of brain or prostate cancer and one idealized scenario, competing three-dimensional conformal and IMRT plans were generated using different beam configurations. Within a given plan and for competing plans with a constant mean target dose, the normalized integral doses within concentric ''shells'' of surrounding normal tissue were quantitatively compared. Within each patient, the normalized integral dose to shells of normal tissue surrounding the target was relatively constant (1). Similarly, for each clinical scenario, the normalized integral dose for a given shell was also relatively constant regardless of the number and orientation of beams (2) or degree of sparing of a critical structure (3). 3D and IMRT planning tools can redistribute, rather than eliminate dose to the surrounding normal tissues (intuitively known by planners). More specifically, dose cannot be moved between shells surrounding the target but only within a shell. This implies that there are limitations in the extent to which a critical structure can be spared based on the location and geometry of the critical structure relative to the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-B-19A-01: MOC: A How-To Guide

Medical physicists who were certified in 2002 or later, as well as those who become certified in the future, are enrolled in Maintenance of Certification. Many physicists with life-time certificates have voluntarily enrolled in MOC, as have physicists who volunteer their time to participate in the ABR exam development and administration processes. MOC consists of four components: Part 1, Professional standing; Part 2, Lifelong learning and self-assessment; Part 3, Cognitive expertise; and Part 4, Practice quality improvement. These four components together evaluate six competencies: Medical knowledge, patient care and procedural skills, interpersonal and communication skills, professionalism, practice-based learning and improvement, and systems-based practice. Parts 1, 2, and 3 of MOC are fairly straightforward, although many participants have questions about the process for attesting to professional standing, the opportunities for obtaining self-assessed continuing education, and the timing of the cognitive exam. MOC participants also have questions about Part 4, Practice Quality Improvement. PQI projects are powerful tools for improving the quality and safety of the environments in which we practice medical physics. In the current version of MOC known as “Continuous Certification” a medical physicist must have completed a PQI project within the previous three years, at the time of the ABR's annual look-back each March. For the first “full” annual look-back in March 2016, diplomates will be given an additional year, so that a PQI project completed in 2012, 2013, 2014, or 2015 will fulfill this requirement. Each component of MOC will be addressed, and the specifics of interest to medical physicists will be discussed. Learning Objectives: Understand the four components and six competencies evaluated by MOC. Become familiar with the annual requirements of Continuous Certification. Learn about opportunities for Practice Quality Improvement projects. Understand refinements occurring in the MOC program.

60 APPLIED LIFE SCIENCES↗

TU-C-17A-01: A Data-Based Development for Pratical Pareto Optimality Assessment and Identification

Purpose: To develop an efficient Pareto optimality assessment scheme to support plan comparison and practical determination of best-achievable practical treatment plan goals. Methods: Pareto efficiency reflects the tradeoffs among competing target coverage and normal tissue sparing in multi-criterion optimization (MCO) based treatment planning. Assessing and understanding Pareto optimality provides insightful guidance for future planning. However, current MCO-driven Pareto estimation makes relaxed assumptions about the Pareto structure and insufficiently account for practical limitations in beam complexity, leading to performance upper bounds that may be unachievable. This work proposed an alternative data-driven approach that implicitly incorporates the practical limitations, and identifies the Pareto frontier subset by eliminating dominated plans incrementally using the Edgeworth Pareto hull (EPH). The exactness of this elimination process also permits the development of a hierarchical procedure for speedup when the plan cohort size is large, by partitioning the cohort and performing elimination in each subset before a final aggregated elimination. The developed algorithm was first tested on 2D and 3D where accuracy can be reliably assessed. As a specific application, the algorithm was applied to compare systematic plan quality for lower head-and-neck, amongst 4 competing treatment modalities. Results: The algorithm agrees exactly with brute-force pairwise comparison and visual inspection in low dimensions. The hierarchical algorithm shows sqrt(k) folds speedup with k being the number of data points in the plan cohort, demonstrating good efficiency enhancement for heavy testing tasks. Application to plan performance comparison showed superiority of tomotherapy plans for the lower head-and-neck, and revealed a potential nonconvex Pareto frontier structure. Conclusion: An accurate and efficient scheme to identify Pareto frontier from a plan cohort has been developed. This implementation would guide generating good yet practically achievable plan quality goals for further planning. The observation of a systematic performance bias and a nonconvex Pareto frontier warrants further investigation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-72: A Retrospective Correlation Analysis On Dose-Volume Control Points and Treatment Outcomes

Purpose: To quantify correlation between dose-volume control points and treatment outcomes. Specifically, two outcomes are analyzed: occurrence of radiation induced dysphagia and target complications. The results inform the treatment planning process when competing dose-volume criteria requires relaxations. Methods: 32 patients, treated with whole-field sequential intensity modulated radiation therapy during 2009–2010 period, are considered for this study. Acute dysphagia that is categorized into 3 grades is observed on all patients. 3 patients are observed in grade 1, 17 patients in grade 2, and 12 patients in grade 3. Ordinal logistic regression is employed to establish correlations between grades of dysphagia and dose to cervico-thoracic esophagus. Particularly, minimum (Dmin), mean (Dmean), and maximum (Dmax) dose control points are analyzed. Additionally, target complication, which includes local-regional recurrence and/or distant metastasis, is observed on 4 patients. Binary logistic regression is used to quantify correlation between target complication and four dose control points. Namely, ICRU recommended dose control points, D2, D50, D95, and D98 are analyzed. Results: For correlation with dysphagia, Dmin on cervico-thoracic esophagus is statistically significant (p-value = 0.005). Additionally, Dmean on cervico-thoracic esophagus is also significant in association with dysphagia (p-value = 0.012). However, no correlation was observed between Dmax and dysphagia (p-value = 0.263). For target complications, D50 on the target is a statistically significant dose control point (p-value = 0.032). No correlations were observed between treatment complications and D2 (p-value = 0.866), D95 (p-value = 0.750), and D98 (p-value = 0.710) on the target. Conclusion: Significant correlations are observed between radiation induced dysphagia and Dmean (and Dmin) to cervico-thoracic esophagus. Additionally, correlation between target complications and median dose to target (D50) is observed. Quantification of these correlations can inform treatment planners when any competing objectives requires relaxation of target D50 or Dmean (or Dmin) to cervico-thoracic esophagus.

60 APPLIED LIFE SCIENCES↗

SU-E-T-531: Large--Scale DVH Quality Study: Correlated Aims Lead Relaxations

Purpose: Intensity modulated radiation therapy plans are designed to optimally target a tumor while sparing surrounding tissue. Desired dose distributions are iteratively approached via inverse planning. This leads to tradeoffs between clinical objectives for the planning target volume (PTV), organs at risk, and normal tissues. Dose volume histogram (DVHs) related aims are followed that are either institutional or internationally recommended. We analyze common goals and identify potential reasons that often lead to tradeoffs. Methods: 524 IMRT plans for various tumor sites were analyzed based on the main institutional DVH goal for PTV (D95) and the recommendations by ICRU-83 (D2, D50, and D98). Robust statistical tools are developed and applied to ensure that the results are immune to data uncertainties. The probability of violation was measured for each of the DVH goals based on the frequency of not meeting recommended doses. Conditional probabilities for satisfying and/or violating DVH aims were computed to test the hypothesized pair-wise relations between DVH aims. For example, for plans that satisfied D50, the probability of violating D98 was computed via P(D98 < 95% | 98% ≤ D50 ≤ 102%). The equality constraint D50 = 100% was relaxed to encompass the range [98,102]%. Results: A large majority of cases (88%) satisfied the institutional goal for PTV of D95 ≤ 95%. Similar consensus existed for D98. 51% of cases satisfied D2 ≥ 107%. However, only 18% of cases satisfied D50. The conditional probability showed correlations amongst the studied DVH goals. In fact, a negative correlation was revealed between D50 and D95 (and D98), suggesting that these competing goals cannot be satisfied concurrently. Conclusion: The majority of plans followed the institutional guidelines. The reason for their deviation from international recommendations seems to be that the latter goals are competing and cannot be satisfied concurrently in clinical practice.

60 APPLIED LIFE SCIENCES↗

WE-G-204-00: Post-Graduate Training of the Next Generation of Academic Medical Physicists

While many indicators for academic medical physics are distressing – jobs are tight, demands on clinical time are high (and getting worse) and national funding has been flat for several years (meaning less money in reality) the present is perhaps one of the most exciting times in cancer research history, and medical physicists have an opportunity to make a difference. Many of us predict the impact of medical physics on cancer research over the next decade to be more significant than ever. Why is that? First, medical imaging is used for every cancer patient in developed countries. Every improvement in the acquisition, processing or analysis of radiological images has the potential to impact patients. The use of radiation therapy is at an all-time high – and virtually cannot be performed without medical physics. Many of the advances in both biomedical imaging and radiation oncology are the result of the hard work of academic medical physicists who are thinking of the next generation of technologies that will be used against cancer or an even broader spectrum of diseases. A career in academic medical physics is demanding, particularly for those with clinical responsibilities. As the demands for justification of their clinical effort become increasingly metricized, the ability to do “unfunded research” will become even more difficult. This means that many will have to generate external salary support to justify their efforts in research and development. This comes at a time when funding for research is compressed and harder to obtain. Generally speaking, if you are not contributing 50% or more of your effort to research, you are competing at a disadvantage and it is very unlikely you will get an NIH/NCI/NIBIB grant. Furthermore, in the ongoing effort to improve patient care and safety, we have developed credentialing pathways that now require at least two-years of residency training. This full-time clinical training creates a gap in the research trajectory of graduate students who aspire to academic positions with an expectation for extramural funding. To address this, several residency programs have created hybrid programs where the two-years of clinical training is combined with one or two years of research effort to allow candidates to further establish an academic identity and to ensure adequate academic productivity to compete for a beginning faculty position. In conclusion, while the path to a successful career in academic medical physics is steep and sometimes hard to follow, reaching the apex is worth the journey. Different paths to a career in medical physics are available, you just have to decide which one is right for you. If improving cancer care is your goal as a physicist, then academic medical physics is the job for you!.

60 APPLIED LIFE SCIENCES↗

WE-G-204-01: Building a Career in Academic Medical Physics: The Hardest and Best Job You Will Ever Have!

While many indicators for academic medical physics are distressing – jobs are tight, demands on clinical time are high (and getting worse) and national funding has been flat for several years (meaning less money in reality) the present is perhaps one of the most exciting times in cancer research history, and medical physicists have an opportunity to make a difference. Many of us predict the impact of medical physics on cancer research over the next decade to be more significant than ever. Why is that? First, medical imaging is used for every cancer patient in developed countries. Every improvement in the acquisition, processing or analysis of radiological images has the potential to impact patients. The use of radiation therapy is at an all-time high – and virtually cannot be performed without medical physics. Many of the advances in both biomedical imaging and radiation oncology are the result of the hard work of academic medical physicists who are thinking of the next generation of technologies that will be used against cancer or an even broader spectrum of diseases. A career in academic medical physics is demanding, particularly for those with clinical responsibilities. As the demands for justification of their clinical effort become increasingly metricized, the ability to do “unfunded research” will become even more difficult. This means that many will have to generate external salary support to justify their efforts in research and development. This comes at a time when funding for research is compressed and harder to obtain. Generally speaking, if you are not contributing 50% or more of your effort to research, you are competing at a disadvantage and it is very unlikely you will get an NIH/NCI/NIBIB grant. Furthermore, in the ongoing effort to improve patient care and safety, we have developed credentialing pathways that now require at least two-years of residency training. This full-time clinical training creates a gap in the research trajectory of graduate students who aspire to academic positions with an expectation for extramural funding. To address this, several residency programs have created hybrid programs where the two-years of clinical training is combined with one or two years of research effort to allow candidates to further establish an academic identity and to ensure adequate academic productivity to compete for a beginning faculty position. In conclusion, while the path to a successful career in academic medical physics is steep and sometimes hard to follow, reaching the apex is worth the journey. Different paths to a career in medical physics are available, you just have to decide which one is right for you. If improving cancer care is your goal as a physicist, then academic medical physics is the job for you!.

60 APPLIED LIFE SCIENCES↗

WE-G-204-02: So You Want to Do Research: Two Approaches to Beginning a Career in Medical Physics Research

While many indicators for academic medical physics are distressing – jobs are tight, demands on clinical time are high (and getting worse) and national funding has been flat for several years (meaning less money in reality) the present is perhaps one of the most exciting times in cancer research history, and medical physicists have an opportunity to make a difference. Many of us predict the impact of medical physics on cancer research over the next decade to be more significant than ever. Why is that? First, medical imaging is used for every cancer patient in developed countries. Every improvement in the acquisition, processing or analysis of radiological images has the potential to impact patients. The use of radiation therapy is at an all-time high – and virtually cannot be performed without medical physics. Many of the advances in both biomedical imaging and radiation oncology are the result of the hard work of academic medical physicists who are thinking of the next generation of technologies that will be used against cancer or an even broader spectrum of diseases. A career in academic medical physics is demanding, particularly for those with clinical responsibilities. As the demands for justification of their clinical effort become increasingly metricized, the ability to do “unfunded research” will become even more difficult. This means that many will have to generate external salary support to justify their efforts in research and development. This comes at a time when funding for research is compressed and harder to obtain. Generally speaking, if you are not contributing 50% or more of your effort to research, you are competing at a disadvantage and it is very unlikely you will get an NIH/NCI/NIBIB grant. Furthermore, in the ongoing effort to improve patient care and safety, we have developed credentialing pathways that now require at least two-years of residency training. This full-time clinical training creates a gap in the research trajectory of graduate students who aspire to academic positions with an expectation for extramural funding. To address this, several residency programs have created hybrid programs where the two-years of clinical training is combined with one or two years of research effort to allow candidates to further establish an academic identity and to ensure adequate academic productivity to compete for a beginning faculty position. In conclusion, while the path to a successful career in academic medical physics is steep and sometimes hard to follow, reaching the apex is worth the journey. Different paths to a career in medical physics are available, you just have to decide which one is right for you. If improving cancer care is your goal as a physicist, then academic medical physics is the job for you!.

60 APPLIED LIFE SCIENCES↗