Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

SNPP and N20 VIIRS Thermal Emissive Bands Calibration Comparison Using the GEO-LEO Double Difference Method

The VIIRS instruments onboard the SNPP and NOAA-20 satellites have identical spatial resolutions and the same spectral bands. Similar prelaunch tests and identical on-orbit calibration algorithms established the foundation for their consistent Earth measurements. Calibration assessment and consistency comparisons are useful to maintain their performance and measurement accuracy. Simultaneous nadir overpasses (SNO) between two satellites are commonly used for a direct calibration comparison between sensors. However, there are no SNO between SNPP and NOAA20. Hence, a reference sensor or Earth measurements are normally used to bridge the comparison. As a reference, we focus on the Advanced Baseline Imager (ABI) onboard the GOES-R series spacecraft and its application to the SNPP and NOAA-20 VIIRS comparison. GOES16 and GOES17are the first two satellites of the GOES-R series and were launched on November 19, 2016, and March 12, 2018, respectively. Their operational positions are on the equator with longitudes of 75.2° West over land and 137.2° West over ocean, respectively. The ABI is the primary imaging instrument of these spacecrafts for the Earth’s weather, oceans, and environment, with observations (every 10 minutes) that provide vast data for GEO-Low Earth orbit (LEO)and LEO-LEO comparisons utilizing it as an intermediate reference sensor. VIIRS and ABI have spectrally matched bands and can have simultaneous measurements over any selected site every day. The simultaneous measurements over the same site also have various scan angles. These features provide advantages for a VIIRS-to-ABI comparison. The spectral response function difference between instruments, sites selected, and view angles will have effects on the instrument measurements. Their impacts on the calibration comparison, including the use of double differences, will be discussed. By collecting VIIRS measurements over a large range of view angles, the view angle effect will also be investigated. The collection of an ample amount of data provides an advantage for statistical analyses and potential big data applications to sensor calibration assessments. This method can also be applied to other sensor calibration comparison and performance assessments, such as GOES16 and GOES17 ABI, and Terra and Aqua MODIS.

Tiejun Chang↗

The Impact of Pixel Size on the Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides the scientific community the observed TOA SW and LW fluxes for climate monitoring and climate model validation. CERES utilizes hourly geostationary imager derived broadband fluxes, which rely on the channel radiances and associated cloud retrievals, are used to estimate the broadband fluxes between CERES observations. This requires stable and consistent cross-platform imager visible channel calibration. The CERES project utilizes deep convective clouds (DCC) as an invariant Earth target to both monitor the stability of sensors and for radiometric scaling. GSICS, an international collaboration, is also evaluating and implementing the DCC invariant target calibration methodology to provide consistent calibration coefficients across geostationary imagers anchored to the AquaMODIS or the NOAA-20 VIIRS calibration reference. Tropical DCC are the brightest, coldest, most Lambertian, top of the atmosphere Earth targets. The DCC invariant target calibration methodology relies on a large ensemble of tropical D CC-identified pixel-level reflectances, which are aggregated as probability density functions (PDF). By assuming the monthly PDF shape is otherwise consistent in time excepting shifts in reflectance caused by changes in the sensor calibration, the imager stability is monitored. Radiometric scaling is accomplished by ratioing the sensor pair DCC PDF reflectance values. The success of the DCC methodology relies on consistent PDF distributions. The goal of this study is to determine the impact of pixel resolution on the DCC reflectance distribution. Single SNPP-VIIRS 750-m and Landsat 8 OLI 30-m granules are aggregated to degrade the pixel resolution from the native level. The DCC pixels are identified using a BT threshold. Most of the brightest DCC pixels are also the coldest, although there are exceptions. It was found that increasing the BT threshold exponentially increased the number of darker pixels. The pixel resolution did not seem to impact the DCC reflectance PDF distribution for pixel resolutions less than 3 km, which suggests that imagers of varying pixel resolutions may be radiometrically scaled to each other using DCC targets.

DCC↗

Mock Truss-Braced Wing Loads Calibration Research Utilizing Fiber-Optic Sensors

In support of the National Aeronautics and Space Administration Advanced Air Transonic Transport Truss-Braced Wing structural research, the Armstrong Flight Research Center Flight Loads Laboratory is performing pathfinder tests on a small, scaled test article (dubbed the mock Truss-Braced Wing) to study the application of a loads calibration on a truss-braced wing structure. The addition of a truss to the wing structure, as opposed to a purely cantilever beam setup, changes the strain-gage-based loads calibration techniques. In a truss-braced configuration, the internal shear and moments, inboard of the truss-wing connection, are not directly representative of the external aerodynamic loading as is the case for a traditional cantilever configuration. A 3-axis load cell was used at the wing-to-strut interface to estimate the load sharing between the two structural members. Crosstalk within the 3-axis load cell is added to the measurement uncertainties of the calibration effort, and the results, including crosstalk uncertainties, are presented. The calibration tests presented in this report are used as a pathfinder for developing an understanding how to perform loads calibration on a truss-braced wing structural configuration. The use of distributed fiber-optic strain sensors is leveraged to provide a near-full-span strain profile along the leading and trailing edge of the wing structure for strain-based loads calibration.

Francisco Peña↗

Overview of NASA's Ocean Color Instrument Solar Calibration Architecture, Pre-Launch Tests and Preliminary On-Orbit Results

Launched in February 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI will provide two day global coverage of TOA radiances. Unlike its predecessors, OCI will cover a spectral range from 340nm to 2260nm. Below 900nm, OCI will include two spectrometers that continuously span the ultraviolet to 600nm and 600nm to near-infrared spectral regions to provide hyperspectral radiances sampled every 2.5 nm, with a bandwidth of 5 nm for each channel. Wavelengths above 900nm are measured in seven discrete multispectral bands of varying bandwidths, six of which are at similar wavelengths to those on heritage missions to support both atmospheric and ocean color applications. Nominal spatial resolution is similar to the SeaWiFS instrument with 1050 m at nadir. As for SeaWiFS, the pixel size increases due to a ~20 degree tilt and as a function of scan angle. Variations in the radiometric sensitivity of each OCI channel over time will be monitored by solar diffuser measurements for short term instrument gain adjustments and independent lunar measurements for trend adjustments of long time periods, similar to the approach employed for the VIIRS instrument [4]. The OCI flight-unit was built at NASA’s Goddard Space Flight Center. At the time of this writing, OCI has completed on-orbit commissioning activities and normal science operations have begun. A key aspect of the OCI architecture is the capability to trend absolute and relative calibration changes over the course of mission life with solar calibration. Every 24 hours, the PACE spacecraft performs an inertial hold as the ground track nears the North Pole which orients a Quasi-Volume Diffuser (QVD) mounted on OCI towards the sun. By knowing the irradiance of the sun and the reflectivity of the target, the absolute radiance at the input to the OCI aperture can be computed as OCI scans the target. The allowable absolute uncertainty budget for each solar calibration measurement is 1.6% 1-sigma below 900nm at beginning of life (BOL) and the allowable relative uncertainty budget is ~0.26% 1-sigma. The Solar Calibration Assembly (SCA) consists of three targets selectable via a single mechanism which also opens a door. The targets consist of a Daily Bright Target (DBT), Monthly Bright Target (MBT), and Daily Dim Target (DDT). The bright targets are quartz QVDs with the monthly target being used to track the degradation of the daily target. The dim target is used to track CCD linearity using Progressive Time-Delay Integration (PTDI). A composite baffle is attached to the SCA housing aperture to block Earth shine and stray light from the spacecraft. The SCA assembly is mounted to a view port ~90° from OCI nadir. This paper provides an overview of driving solar calibration requirements, error-budgets and early trade studies which drove the solar calibration assembly (SCA) architecture and on-orbit maneuver. Measurements of the diffuser Bidirectional Reflectance Distribution Function (BRDF) at TNO, Netherlands and GSFC are briefly described. Optical modelling and test results at the sub-system and instrument level are included. Finally, preliminary measurements on-orbit are compared to pre-launch predictions.

Joseph J Knuble↗

Deep Convective Cloud Calibration Sensitivity Studies in Support of Radiometrically Scaling GEO Imagers With VIIRS

The NASA CERES SYN1deg product provides the scientific community regional hourly TOA and surface broadband fluxes and clouds. For consistent geostationary (GEO) derived fluxes and clouds the GEO imagers are radiometrically scaled to the Aqua-MODIS calibration reference. The CERES project utilizes GEO and MODIS or VIIRS analogous channel coincident, collocated, and co-angled radiance pairs as the primary method to inter-calibrate the GEO imagers. Tropical deep convective clouds (DCC) are bright, near Lambertian, top of atmosphere pseudo invariant Earth targets that do not rely on coincident ray-matched radiance pairs to radiometrically scale sensors to a common calibration reference. The DCC invariant target (DCC-IT) methodology collectively analyzes all tropical DCC identified pixel radiances by way of probability density function (PDF) distributions. Perfectly inter-calibrated sensor pairs should reveal nearly identical PDF distributions given the same DCC identification criterion. The PDF median, mean, mode, and inflection point statistics were tested as a function of DCC identification criterion using SNPP-VIIRS and Himawari-8 AHI 0.65μm channel radiances during January 2019. It was found that the PDF inflection point provided inter-calibration factors within 0.25% that were nearly independent of DCC identification criterion. The PDF median provided inter-calibration factors within 0.25% for the coldest BT and most stringent homogeneity factors. The PDF mean and mode statistics were inadequate under any DCC conditions. It is critical for the DCC pixel radiances to be anisotropically corrected. The DCC-IT methodology will also be tested for other visible and SWIR bands.

DCC↗

Inter-Calibrating CERES Instrument Fluxes Utilizing the CERES Instrument Geostationary Scan Mode Observations

The NASA Clouds and the Earth’s Radiant Energy System (CERES) project provides the scientific community observed top-of-atmosphere (TOA) fluxes to monitor the Earth’s energy imbalance and validate climate models. The CERES instruments onboard the Terra, Aqua, SNPP and NOAA-20 satellites need to be inter-calibrated to provide a continuous and consistent TOA flux record contained in the CERES Energy Balanced and Filled (EBAF) product. The SNPP and NOAA-20 satellites are positioned a half an orbit apart within the same sun-synchronous orbit (1:30 PM equatorial crossing time) thus preventing any direct time-matched observations. The CERES project designed the geostationary scan mode (GEOscan) to inter-calibrate the Geostationary Earth Radiation Budget (GERB) broadband measurement onboard the Meteosat 8-11 satellites. By rotating the orientation of the CERES instrument scan to match the angular configuration of the geostationary scan mode, the comparison of both angle and time matched observations suitable for inter-calibration is possible. To determine if the GEOscan mode is useful for inter-calibrating two CERES instruments placed in the same 16-day repeating orbit, the CERES project placed the Terra and Aqua CERES instruments in GEOscan mode once every 6 days over a rotation of five geostationary domains beginning in February 2023. The GEO imager narrowband to broadband derived radiances are used as transfer radiometers to compare the Terra and Aqua CERES observed radiances. Since both the Terra and Aqua CERES instruments are in GEOscan mode over the same GEO domain and day, the GEO imager calibration is expected to be consistent between the Terra and Aqua overpass times. Any GEO imager narrowband to broadband regional biases should be similar for the Terra and Aqua overpasses. The GEOscan mode Terra and Aqua CERES inter-calibration coefficients for both shortwave and longwave broadband radiances will be compared against the CERES instrument team’s coefficients to determine the viability of this approach. Improvements in the GEO imager narrowband to broadband approaches will also be investigated and verified within this framework.

Kyle Itterly↗

Inter-Calibrating the CERES SW Instrument Fluxes Using Deep Convective Clouds(DCC) Within the Same Sun-Synchronous Orbit

The NASA CERES EBAF product provides the scientific community observed TOA fluxes to monitor the Earth’s energy imbalance and to validate climate models. To provide a seamless EBAF 24-year record, the CERES instrument calibration must be stable and consistent across satellite records. Once the Terra and Aqua spacecraft are decommissioned at the end of 2025, the CERES project will rely on CERES instrument observations on the SNPP and NOAA-20 1:30 PM sun-synchronous orbits. The SNPP and NOAA-20 satellite orbit placement will prevent any time matched observations for inter-calibration efforts. The future Libera instrument, which will continue the CERES record and scheduled for launch in 2028 onboard the NOAA-22 satellite, will also need to be inter-calibrated without the aid of time-matched observations. Deep convective clouds (DCC) are the most Lambertian, brightest, tropical Earth invariant targets located at the tropopause making them ideal to radiometrically scale the CERES SW observed radiance to a common reference. The SNPP, NOAA-20 and future NOAA-22 satellites are in the same 16-day repeatable orbits, allowing the DCC targets to be observed with the same angular configuration. The empirically derived SNPP CERES SW channel Bidirectional Reflectance Distribution Function (BRDF) can be easily be applied to the NOAA-20 CERES SW channel radiances since they observe the nearly the same DCC systems. The DCC BRDF corrected radiances are analyzed collectively into radiance probability distribution functions (PDF). By comparing the PDF statistics, the SNPP and NOAA-20 CERES SW channel can be inter-calibrated. The inter-calibration coefficients are validated with the CERES instrument calibration team coefficients to optimize the methodology.

David Doelling↗

In-Flight Calibration of ESA Hera’s Hyperscout-H Imager

ESA’s Hera space mission is on its way to the mission target, the binary asteroid (65803) Didymos. HyperScout-H, one of the instruments onboard Hera, is a hyperspectral imager operating in the visible and near-infrared regions between 0.65 and 0.95 μm. HyperScout-H will enable a detailed assessment of the composition of both objects, Didymos and its satellite Dimorphos, the characterization of space weathering effects, and the possible presence of exogenous material on their surfaces. To monitor instrument functionality, calibration exposures are acquired regularly. This article describes the in-flight calibrations carried out for HyperScout-H during the commissioning and cruise phases. Bias and dark exposures, as well as stellar field observations, were acquired several times after launch. We update the calibration data and monitor instrument performance in the space environment. In addition, images of Earth and Moon were acquired from distances of 1.5 × 10 6 to 2.0 × 10 6 km, and Mars and its satellite were imaged during the flyby. In five images, the surface of Mars fills the entire field of view, enabling cross-validation of HyperScout-H results with those reported by other Mars missions. We characterize the detector under in-flight operational conditions. The calibration data indicate that the bias pattern is stable, the dark current remains negligible for short exposures, and the detector response is highly linear. We quantify the field-of-view alignment and geometric distortion, and evaluate the point spread function based on the stellar field observations. Stellar observations and Mars swing-by data provide updated radiometric calibration constants, suggesting that in-flight conditions have slightly modified the detector’s spectral response. In-flight calibrations are essential to ensure data quality and reliability.

Image Processing↗

Analysis of calibration materials to improve dual-energy CT scanning for petrophysical applications

Dual energy CT-scanning is a rapidly emerging imaging technique employed in non-destructive evaluation of various materials. Although CT (Computerized Tomography) has been used for characterizing rocks and visualizing and quantifying multiphase flow through rocks for over 25 years, most of the scanning is done at a voltage setting above 100 kV for taking advantage of the Compton scattering (CS) effect, which responds to density changes. Below 100 kV the photoelectric effect (PE) is dominant which responds to the effective atomic numbers (Zeff), which is directly related to the photo electric factor. Using the combination of the two effects helps in better characterization of reservoir rocks. The most common technique for dual energy CT-scanning relies on homogeneous calibration standards to produce the most accurate decoupled data. However, the use of calibration standards with impurities increases the probability of error in the reconstructed data and results in poor rock characterization. This work combines ICP-OES (inductively coupled plasma optical emission spectroscopy) and LIBS (laser induced breakdown spectroscopy) analytical techniques to quantify the type and level of impurities in a set of commercially purchased calibration standards used in dual-energy scanning. The Zeff data on the calibration standards with and without impurity data were calculated using the weighted linear combination of the various elements present and used in calculating Zeff using the dual energy technique. Results show 2 to 5% difference in predicted Zeff values which may affect the corresponding log calibrations. The effect that these techniques have on improving material identification data is discussed and analyzed. The workflow developed in this paper will translate to a more accurate material identification estimates for unknown samples and improve calibration of well logging tools.

42 ENGINEERING↗

Advancing earth system model calibration: a diffusion-based method

Understanding of climate impact on ecosystems globally requires site-specific model calibration. Here we introduce a novel diffusion-based uncertainty quantification (DBUQ) method for efficient model calibration. DBUQ is a score-based diffusion model that leverages Monte Carlo simulation to estimate the score function and evaluates a simple neural network to quickly generate samples for approximating parameter posterior distributions. DBUQ is stable, efficient, and can effectively calibrate the model given diverse observations, thereby enabling rapid and site-specific model calibration on a global scale. This capability significantly advances Earth system modeling and our understanding of climate impacts on Earth systems. We demonstrate DBUQ's capability in E3SM land model calibration at the Missouri Ozark AmeriFlux forest site. Both synthetic and real-data applications indicate that DBUQ produces accurate parameter posterior distributions similar to those generated by Markov Chain Monte Carlo sampling but with 30X less computing time. This efficiency marks a significant stride in model calibration, paving the way for more effective and timely climate impact analyses.

Liu, Yanfang↗

Stepwise Dynamic Calibration of a Hydromechanical Simulation Using Time-Lapse Vertical Seismic Profile

This study aims to develop a methodology for calibrating subsurface stress changes through time-lapse Vertical Seismic Profiling (VSP) integration. The selected study site is the 13-10A injector well within the ongoing CO2-EOR operation of the Farnsworth Field Unit. The Time-lapse VSP dataset carries the combined effects of fluid substitution and mean effective stress changes, thereby providing a dataset amenable for the calibration of production and injection-induced stress changes. The concept is similar to calibrating a reservoir simulation model in that the process honor real field data to set up an inverse problem. The solution optimizes the independent and impactful geomechanical parameters that replicate the observed time-lapse seismic velocity changes. This stress calibration is enabled by 4D geomechanical modeling and the VSP Integration workflow. This calibration benefits from extensive geological, geophysical and geomechanical characterization through 3D seismic data, geophysical well logs, and core assessed as part of the 1D MEM conducted on the 13-10A subject well. These data are used to develop a site-specific rock physics model. The Biot Gassmann workflow combines rock physics and reservoir simulation outputs to determine the fluid substitution contribution to seismic velocity change. Additionally, modeled seismic velocity attributed to mean effective stress are determined from the geomechanical simulation outputs, and the stress-velocity relationship developed from the ultrasonic seismic velocity measurements on the extracted Morrow B core. A penalty function is then formed between the modeled seismic velocities and the observed time-lapse VSP dataset. Four independent and impactful geomechanical parameters have been determined. These are the bulk modulus and shear modulus for zero porosity and the shear and compressional seismic velocity to mean effective stress derivatives. The dataset of numerous coupled hydromechanical- geomechanical simulation realizations is built by combining variations of the four stated geomechanical parameters. A machine learning-assisted workflow comprised of an artificial neural network and a particle swarm optimizer are used to converge on the optimal geomechanical parameters. The successful execution of this workflow has affirmed the suitability of acoustic time-lapse measurements for 4D-VSP geomechanical stress calibration pending measurable stress sensitivities within the anticipated effective stress changes and the availability of suitable and reliable datasets for petroelastic modeling.

02 PETROLEUM↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

A new time calibration method for switched-capacitor-array-based waveform samplers

Here we have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. Ultimately, the new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ABSOLUTE FLUX CALIBRATION OF THE IRAC INSTRUMENT ON THE SPITZER SPACE TELESCOPE USING HUBBLE SPACE TELESCOPE FLUX STANDARDS

The absolute flux calibration of the James Webb Space Telescope (JWST) will be based on a set of stars observed by the Hubble and Spitzer Space Telescopes. In order to cross-calibrate the two facilities, several A, G, and white dwarf stars are observed with both Spitzer and Hubble and are the prototypes for a set of JWST calibration standards. The flux calibration constants for the four Spitzer IRAC bands 1-4 are derived from these stars and are 2.3%, 1.9%, 2.0%, and 0.5% lower than the official cold-mission IRAC calibration of Reach et al., i.e., in agreement within their estimated errors of {approx}2%. The causes of these differences lie primarily in the IRAC data reduction and secondarily in the spectral energy distributions of our standard stars. The independent IRAC 8 {mu}m band-4 fluxes of Rieke et al. are about 1.5% {+-} 2% higher than those of Reach et al. and are also in agreement with our 8 {mu}m result.

79 ASTRONOMY AND ASTROPHYSICS↗

Online Sensor Calibration Assessment in Nuclear Power Systems

Safe, efficient, and economic operation of nuclear systems (nuclear power plants, fuel fabrication and storage, used fuel processing, etc.) relies on transmission of accurate and reliable measurements. During operation, sensors degrade due to age, environmental exposure, and maintenance interventions. Sensor degradation can affect the measured and transmitted signals, including sensor failure, signal drift, sensor response time, etc. Currently, periodic sensor recalibration is performed to avoid these problems. Sensor recalibration activities include both calibration assessment and adjustment (if necessary). In nuclear power plants, periodic recalibration of safety-related sensors is required by the plant technical specifications. Recalibration typically occurs during refueling outages (about every 18 to 24 months). Non-safety-related sensors also undergo recalibration, though not as frequently. However, this approach to maintaining sensor calibration and performance is time-consuming and expensive, leading to unnecessary maintenance, increased radiation exposure to maintenance personnel, and potential damage to sensors. Online monitoring (OLM) of sensor performance is a non-invasive approach to assess instrument calibration. OLM can mitigate many of the limitations of the current periodic recalibration practice by providing more frequent assessment of calibration and identifying those sensors that are operating outside of calibration tolerance limits without removing sensors or interrupting operation. This can support extended operating intervals for unfaulted sensors and target recalibration efforts to only degraded sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗