FC-PLACER (Fuel Cell Plant Layout and Cost Estimation Resource) [SWR-26-027]

The Fuel Cell Plant Layout and Cost Estimation Resource (FC-PLACER) is a tool to perform a footprint and cost analysis for hydrogen fuel cell based power plants. This analysis tool provides a comprehensive design and cost assessment for a 100-MW stationary PEM fuel cell power plant, utilizing specifications from commercially available PEM fuel cell modules originally designed for heavy-duty vehicle applications. Additionally, the tool offers flexibility, enabling adaptation to various capacity requirements or plant configurations and facilitating the evaluation of system layout and overnight costs. In particular, it includes a detailed accounting of balance of plant material and labor costs and enables a precise estimate of plant spatial footprint.

Reznicek, Evan [National Laboratory of the Rockies↗

Quantifying pH buffering capacity in acidic, organic-rich Arctic soils: Measurable proxies and implications for soil carbon degradation

Dynamic pH change promoted by biogeochemical reactions in Arctic tundra soils can be a major control on the production and release of CO 2 and CH 4 , which contribute to rising global temperatures. Large quantities of soil organic matter (SOM) in these soils are susceptible to microbial decomposition, leading to pH changes during permafrost thaw. Soil pH buffering capacity (β) modulates the extent of pH change but has not been thoroughly studied and represented in predictive ecosystem scale biogeochemical models in Arctic tundra soils. In this study, we generated titration curves for 21 acidic tundra soils from three Arctic sites across northern Alaska, United States of America. Geochemical and hydrological soil properties were evaluated, and correlations with β were developed. Strong correlations between β and both gravimetric water content (Θ g ) (R 2 = 0.847, p < 0.001) and soil water retention (SWR) (R 2 = 0.849, p = 0.001) indicate that the ability of soil to retain water could be associated with its buffering properties. Correlations between β and soil organic carbon (SOC) and cation exchange capacity (CEC) were also explored, and relationships to SWR are discussed. These correlations were then used with existing soil databases reporting SOC, CEC, and SWR to estimate β across Alaska soils. We further demonstrated the quantitative relationships between β and the simulated rates of biogeochemical reactions and show that lower β leads to higher soil pH and more CH 4 production. Overall, our study provides simple proxies for β in Arctic soils and highlights the importance and implications of representing soil buffering in predictive models, thereby enabling quantitative coupling between pH dynamics associated with biogeochemical reactions. Integrating β into predictive models of Arctic biogeochemical cycling may reduce model uncertainty and further our understanding of permafrost SOM degradation accelerated by warming.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Static and dynamic properties of the frustrated spin-$\frac{1}{2}$ depleted-kagome antiferromagnet Cu 7 (TeO 3 ) 2 (SO 4 ) 2 (OH) 6

The structural and magnetic properties of the two-dimensional spin-$\frac{1}{2}$ depleted-kagome compound Cu 7 (TeO 3 ) 2 (SO 4 ) 2 (OH) 6 are investigated using x-ray diffraction, magnetization, heat capacity, and 1 H Nuclear Magnetic Resonance (NMR) measurements. From the analysis of magnetic susceptibility, we found a large Curie-Weiss temperature [𝜃 CW = −50⁢(2)⁢K] and the coexistence of antiferromagnetic and ferromagnetic interactions. The value of 𝜃 CW gives an estimate of the average nearest-neighbor antiferromagnetic interaction of 𝐽/𝑘 B ≃ 66K. The NMR relaxation rates (1/𝑇 1 and 1/𝑇 2 ) exhibit a peak, providing evidence for a magnetic long-range order at 𝑇* ≃ 4K which appears to be canted antiferromagnetic type. Heat capacity also features a broad maximum at 𝑇* that moves towards higher temperatures with increasing magnetic field, reflecting defect induced Schottky anomaly. The frustration parameter 𝑓 𝑟 = |𝜃 CW |/𝑇* ≃ 12.5 renders the compound a highly frustrated low-dimensional magnet.

Akshay, K. U. [Indian Institute of Science Educati↗

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

Cost estimation of balance of plant equipment scale up for proton exchange membrane water electrolyzer systems

Water electrolyzers that use electricity to split water into hydrogen and oxygen could be a key technology for increasing hydrogen supply to meet expanded and emerging market applications, although currently the capital costs of these electrolyzers are high. Here we examine cost reductions that might be achieved by scaling up proton exchange membrane (PEM) electrolyzer systems and leveraging economies of scale through balance of plant (BOP) components for system sizes between 1 MW and 1 GW. We estimate BOP equipment capital costs of about $\$$848/kW at 1 MW, potentially decreasing to $\$$87/kW at 1 GW (2022-dollar year basis) with most of the cost reduction happening as systems scale from 1 MW to 100 MW. We find that BOP subsystems hydrogen drying and water knockout benefited the most from economies-of-scale cost reductions, and piping, instrumentation, and housing and power electronics were less impacted. These cost reductions from economies of scale could be more significant than estimated cost reductions from manufacturing scale-up reported in literature. These results add to the knowledge base that could guide optimal system designs that balance process scale-up with plant modularization and numbering-up. We also estimate that scaling up BOP could potentially lower the levelized cost of hydrogen (LCOH) by $\$$1.7-$\$$4.6/kg, depending on the scale-up magnitude and the plant capacity factor.

08 HYDROGEN↗

A multi-agent approach to distribution system fault section estimation in smart grid environment

We report that Multi-Agent Systems (MAS) are seen from different areas as one of the paramount trends for the next generation of power systems. Numerous published studies about MAS discuss its utilization in power distribution networks but none focuses on the prior step to restoration and self-healing that is fault section estimation. This paper aims to show how MAS can improve the utilities’ reliability indexes and consumer satisfaction by overcoming the multiple fault section estimation problem. In order to do this, the authors considered using MAS as a means of communication between smart meters. The purpose of smart meters usage is to employ devices that are already present in smart grids, mainly because of their reading and saving data capacity. The proposed method was tested on a radial feeder generated by the authors. The network was built on HYPERSIM, a software platform of OPAL-RT Technologies. The simulation results show that this MAS provides speed, efficiency, and automation for the process of fault section estimation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Magnetism of single crystalline breathing pyrochlore spinel AgInCr 4 ⁢S 8

Single crystals of Ag⁢In⁢Cr 4⁢ S 8 are grown by chemical vapor transport and crystallographic ordering of Ag/In that results in a breathing pyrochlore motif of Cr 3+ is verified by x-ray and neutron diffraction. Long-range antiferromagnetic order is observed below a Néel temperature of 𝑇 N ≈ 9.6 K. The magnetic properties are characterized using ac and dc magnetization, specific heat capacity, and single crystal neutron diffraction measurements. The specific heat data are characterized by a small lambda anomaly near 9.5 K and the estimated magnetic entropy reaches ≈ $\frac{1}{3}$ of the expected value by 3⁢𝑇 N , suggesting significant short-range order in the paramagnetic phase. Single crystal neutron diffraction evidences an incommensurate spin structure with propagation vector 𝒌 = (0,0,𝛿) and 𝛿 = 0.343 at 5 K. The minimal model that accounts for the data consists of ferromagnetic layers of Cr atoms, with magnetic moments lying in the plane of the layers and modulating in the perpendicular direction to form a helical structure propagating along 𝒌. Furthermore, this study represents a rare investigation of single crystals within the family of breathing pyrochlore materials.

Frustrated magnetism↗

Soil Moisture Drought Monitoring and Forecasting Using Satellite and Climate Model Data over Southwestern China

In this paper, an experimental soil moisture drought monitoring and seasonal forecasting framework based on the Variable Infiltration Capacity model (VIC) over southwestern China (SW) is presented. Satellite precipitation data are used to force VIC for a near-real-time estimate of land surface hydrologic conditions. Initialized with satellite-aided monitoring (MONIT), the climate model (CFSv2)-based forecast (MONIT+CFSv2) and ensemble streamflow prediction (ESP)-based forecast (MONIT+ESP) are both performed. One dry season drought and one wet season drought are employed to test the ability of this framework in terms of real-time tracking and predicting the evolution of soil moisture (SM) drought, respectively. The results show that the skillful CFSv2 climate forecasts (CFs) are only found at the first month. The satellite-aided monitoring is able to provide a reasonable estimate of forecast initial conditions (ICs) in real-time mode. In the presented cases, MONIT+CFSv2 forecast exhibits comparable performance against the observation-based estimates for the first month, whereas the predictive skill largely drops beyond 1 month. Compared to MONIT+ESP, MONIT+CFSv2 ensembles give more skillful SM drought forecast during the dry season, as indicated by a smaller ensemble range, while the added value of MONIT+CFSv2 is marginal during the wet season. Furthermore, a quantitative attribution analysis of SM forecast uncertainty demonstrates that SM forecast skill is mostly controlled by ICs at the first month and that uncertainties in CFs have the largest contribution to SM forecast errors at longer lead times. This study highlights a value of this framework in generating near-real-time ICs and providing a reliable SM drought prediction with 1 month ahead, which may greatly benefit drought diagnosis, assessment, and early warning.

54 ENVIRONMENTAL SCIENCES↗

FY-2016 Methyl Iodide Higher NOx Adsorption Test Report

Deep-bed methyl iodide adsorption testing has continued in Fiscal Year 2016 under the Department of Energy (DOE) Fuel Cycle Technology (FCT) Program Offgas Sigma Team to further research and advance the technical maturity of solid sorbents for capturing iodine-129 in off-gas streams during used nuclear fuel reprocessing. Adsorption testing with higher levels of NO (approximately 3,300 ppm) and NO2 (up to about 10,000 ppm) indicate that high efficiency iodine capture by silver aerogel remains possible. Maximum iodine decontamination factors (DFs, or the ratio of iodine flowrate in the sorbent bed inlet gas compared to the iodine flowrate in the outlet gas) exceeded 3,000 until bed breakthrough rapidly decreased the DF levels to as low as about 2, when the adsorption capability was near depletion. After breakthrough, nearly all of the uncaptured iodine that remains in the bed outlet gas stream is no longer in the form of the original methyl iodide. The methyl iodide molecules are cleaved in the sorbent bed, even after iodine adsorption is no longer efficient, so that uncaptured iodine is in the form of iodine species soluble in caustic scrubber solutions, and detected and reported here as diatomic I2. The mass transfer zone depths were estimated at 8 inches, somewhat deeper than the 2-5 inch range estimated for both silver aerogels and silver zeolites in prior deep-bed tests, which had lower NOx levels. The maximum iodine adsorption capacity and silver utilization for these higher NOx tests, at about 5-15% of the original sorbent mass, and about 12-35% of the total silver, respectively, were lower than for trends from prior silver aerogel and silver zeolite tests with lower NOx levels. Additional deep-bed testing and analyses are recommended to expand the database for organic iodide adsorption and increase the technical maturity if iodine adsorption processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ION Engineering Commercial Carbon Capture Design & Costing (C3DC) (Final Report)

ION Engineering LLC (ION) has coupled its proven, solvent-based CO 2 capture technology with an exceptionally qualified design and engineering team to complete a pre FEED for a 300-megawatt equivalent commercial-scale CO 2 capture plant for Gerald Gentleman Station’s (GGS) Generation Unit 2 (GGS2). The remarkable team was comprised of ION, Nebraska Public Power District (NPPD), Sargent & Lundy (S&L) with continued support from Koch Modular Process Systems (KMPS), and Siemens. The overall objective of the project was to provide the engineering design and cost estimate at an American Association of Cost Engineers (AACE) Class 3 estimate, resulting in accuracy ranges of -20 to +30% for the capital cost estimate. The project team was successful in completing this objective and was able to overcome the challenges that were presented during the process. A conservative interest rate of 7.0% with a financing term of 20 years was used based on interest rates utilized by S&L for this level of study. The resulting annualization factor is multiplied by the total EPC cost to calculate an annualized capital expenditure. It is estimated that the carbon capture facility treating a 300 MWe slipstream will capture 1.9 million tonnes per year of CO 2 at a capacity factor of 85%. The resulting cost of capture for the CO 2 island was determined to be $\$$36.55/tonne. Utilizing an interest rate of 4.5%, supported by historical rates for previous large capital projects in the power industry, reduces the cost of capture to $32.52/tonne. These cost of capture numbers continue to further ION’s case for commercial deployment of ION’s solvent technology.

20 FOSSIL-FUELED POWER PLANTS↗

Atmospheric helium and geomagnetic field reversals.

The problem of the earth's helium budget is examined in the light of recent work on the interaction of the solar wind with nonmagnetic planets. It is proposed that the dominant mode of helium (He4) loss is ion pumping by the solar wind during geomagnetic field reversals, when the earth's magnetic field is very small. The interaction of the solar wind with the earth's upper atmosphere during such a period is found to involve the formation of a bow shock. The penetration altitude of the shock-heated solar plasma is calculated to be about 700 km, and ionization rates above this level are estimated for a cascade ionization (electron avalanche) process to average 10 to the 9th power ions/sq cm/sec. The calculated ionization rates and the capacity of the solar wind to remove ionized helium (He4) from the upper atmosphere during geomagnetic dipole reversals are sufficient to yield a secular equilibrium over geologic time scales. The upward transport of helium from the lower atmosphere under these conditions is found to be adequate to sustain the proposed loss rate.

Sheldon, W. R.↗

The Dynairship

A feasibility analysis for the construction and use of a combination airplane-airship named 'Dynairship' is undertaken. Payload capacities, fuel consumption, and the structural design of the craft are discussed and compared to a conventional commercial aircraft (a Boeing 747). Cost estimates of construction and operation of the craft are also discussed. The various uses of the craft are examined (i.e, in police work, materials handling, and ocean surveillance), and aerodynamic configurations and photographs are shown.

Miller, W. M., Jr.↗

An integrated study of earth resources in the state of California using remote sensing techniques

The author has identified the following significant results. The effects on estimates of monthly volume runoff were determined separately for each of the following parameters: precipitation, evapotranspiration, lower zone and upper zone tension water capacity, imperviousness of the watershed, and percent of the watershed occupied by riparian vegetation, streams, and lakes. The most sensitive and critical parameters were found to be precipitation during the entire year and springtime evapotranspiration.

Colwell, R. N.↗

Design and calculated performance and cost of the ECAS Phase II open cycle MHD power generation system

A 2000 MWe MHD/steam plant for central station applications has been designed and costed as part of the Energy Conversion Alternatives Study (ECAS). This plant is fueled by Illinois No. 6 coal, rejects heat through mechanical draft wet cooling towers, and includes coal processing equipment, seed reprocessing, electrical inversion of the MHD generator output and emission controls to current EPA standards. It yields an estimated overall efficiency of 0.483 (7066 Btu/kWe-hr), a capital cost of $718 per kWe (1975 dollars), and a cost of electricity at 65% capacity factor of 32 mills per kWe-hr. If the assumed life and reliability could be achieved with these performance parameters, the MHD system should prove attractive.

Harris, L. P.↗

Changes of instability thresholds of rotor due to bearing misalignments

The influence of bearing misalignment upon the dynamic characteristics of statistically indeterminant rotor bearing systems is investigated. Both bearing loads and stability speed limits of a rotor may be changed significantly by magnitude and direction of bearing misalignment. The useful theory of short journal bearings is introduced and simple analytical expressions, governing the misalignment problem, are carried out. Polar plots for the bearing load capacities and stability maps, describing the speed limit in terms of misalignment, are presented. These plots can be used by the designer to estimate deviations between calculation and experimental data due to misalignment effects.

Springer, H.↗

DS-2 Mars Microprobe Battery

In January of 1999 the NM DS-2 Mars microprobe will be launched to impact on Mars in December. The technical objectives of the missions are to demonstrate: key technologies, a passive atmospheric entry, highly integrated microelectronics which can withstand both low temperatures and high decelerations, and the capability to conduct in-situ, surface and subsurface science data acquisition. The scientific objectives are to determine if ice is present below the Martian surface, measure the local atmospheric pressure, characterize the thermal properties of the martian subsurface soil, and to estimate the vertical temperature gradient of the Martian soil. The battery requirements are 2-4 cell batteries, with voltage of 6-14 volts, capacity of 550 mAh at 80C, and 2Ah at 25C, shelf life of 2.5 years, an operating temperature of 60C and below, and the ability to withstand shock impact of 80,000 g's. The technical challenges and the approach is reviewed. The Li-SOCL2 system is reviewed, and graphs showing the current and voltage is displayed, along with the voltage over discharge time. The problems encountered during the testing were: (1) impact sensitivity, (2) cracking of the seals, and (3) delay in voltage. A new design resulted in no problems in the impact testing phase. The corrective actions for the seal problems involved: (1) pre weld fill tube, (2) an improved heat sink during case to cover weld and (3) change the seal dimensions to reduce stress. To correct the voltage delay problem the solutions involved: (1) drying the electrodes to reduce contamination by water, (2) assemblage of the cells within a week of electrode manufacture, (3) ensure electrolyte purity, and (4) provide second depassivation pulse after landing. The conclusions on further testing were that the battery can: (1) withstand anticipated shock of up to 80,000 g, (2) meet the discharge profile post shock at Mars temperatures, (3) meet the required self discharge rate and (4) meet environmental requirements.

Frank, H.↗

Two-Phase Cryogenic Heat Exchanger for the Thermodynamic Vent System

A two-phase cryogenic heat exchanger for a thermodynamic vent system was designed and analyzed, and the predicted performance was compared with test results. A method for determining the required size of the Joule-Thomson device was also developed. Numerous sensitivity studies were performed to show that the design was robust and possessed a comfortable capacity margin. The comparison with the test results showed very similar heat extraction performance for similar inlet conditions. It was also shown that estimates for Joule- Thomson device flow rates and exit quality can vary significantly and these need to be accommodated for with a robust system design.

Christie, Robert J.↗

Satellite estimation of the surface energy balance, moisture availability and thermal inertia

A method for inferring the distribution of surface heat and evaporative fluxes and the ground moisture availability and thermal inertia (ground conductive capacity) is used to analyze two urbanized areas, Los Angeles and St. Louis. The technique employs infrared satellite temperature measurements in conjunction with a one-dimensional boundary-layer model. Results show that there is a marked reduction of evaporation and moisture availability and a corresponding elevation of sensible heat flux over urbanized areas and over cropped areas with low vegetative cover. Conversely, low heat flux and high evaporation characterize vegetated and, especially, forested areas. Warm urban centers appear directly related to a reduction in vegetation, which normally allows for a greater fraction of available radiant energy to be converted into latent heat flux. The distribution of thermal inertia was surprisingly ill-defined and its variation between urban and rural areas was quite small. Thus, the increased heat storage within the urban fabric, which has been proposed as the underlying cause of the nocturnal heat island, may be caused mainly by enhanced daytime surface heating which occurs because of surface dryness, rather than by large spatial variations in the conductivity of the surface.

Carlson, T. N.↗